| Key | Internal Dimensions (D×W×H): 400×1250×700 mm |
|---|---|
| External Dimensions (D×W×H) | 450×1350×1700 mm |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | 65–95% RH |
| Sample-to-Lamp Distance | 240 mm |
| Spectral Range | 295–330 nm |
| Irradiance | 1000 µW/cm² @ 340 nm |
| Lamp Configuration | 8 × 40 W, 1200 mm linear xenon arc lamps |
| Condensation Method | Gravity-fed water condensation |
| Inner Chamber Material | SUS304 stainless steel |
| Control System | Digital temperature & timer controller |
| Water Consumption | ~8 L/day (deionized or distilled water recommended) |
| Key | Brand – Other Brands |
|---|---|
| Construction – Interior | SUS304 stainless steel |
| Exterior | Powder-coated steel |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 121 °C, 132 °C (143 °C optional) |
| Humidity | 100 % RH (saturated steam) |
| Operating Pressure | 0–2.0 kg/cm² (gauge), up to 3.0 kg/cm² (custom) |
| Internal Dimensions (Φ × D) | 30×45 cm to 60×65 cm |
| External Dimensions (W × H × D) | 65×100×65 cm to 85×120×90 cm |
| Temperature Uniformity | ≤ ±2 °C |
| Pressure & Temperature Safety Interlocks | Yes |
| Water Level Auto-Replenishment | Yes |
| Power Supply | AC 220 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-500 |
| Xenon Lamp Power Options | 1.8 kW / 2.5 kW / 6 kW |
| Spectral Irradiance Range | 300–800 nm, calibrated at 550 W/m² ±10% |
| Light Exposure Cycle | 1–999 h/min/sec (programmable) |
| Humidity Range (Light Cycle) | 20–75% RH |
| Cooling Method | Air-cooled or optional water-cooled lamp system |
| Filter Configurations | Daylight Filter (ISO 4892-2), Window Glass Filter (ISO 16474-2) |
| Black Standard Temperature Control | Ambient to 120°C |
| Sample Rotation | Motor-driven drum rotation for uniform irradiation |
| Compliance | ISO 4892-2, ISO 16474-2, ASTM G155, ASTM D7869, SAE J2527/J2412, GB/T 16422.2, GB/T 1865 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (Reference Only) |
| Humidity Range | 20–95% RH |
| Chamber Temperature Range | 20–65°C |
| Black Panel Temperature Range | 20–100°C |
| Irradiance Control | 0–1120 W/m² (300–800 nm) |
| Total Exposure Area | 6500 cm² |
| Light Source | Water-Cooled Xenon Arc Lamp |
| Construction | Cold-Rolled Steel Exterior with Powder Coating |
| Interior | SUS304 Stainless Steel |
| Sealing | High-Temperature Silicone Gasket |
| Humidification | Precision Spray System (Specimen Wetting) |
| Air Circulation | Long-Shaft Motor-Driven Forced Convection |
| Control System | TEMI850 Touchscreen Controller (South Korea) |
| Radiation Monitoring | “F-ZA” Full-Spectrum Radiometer |
| Temperature Sensors | Black Panel Thermometer (BPT) and/or Black Standard Thermometer (BST) |
| Optical Filtering | Standard Daylight & Extended UV Filters |
| Sample Mounting | Rotating Stainless Steel Rack with Tempered Glass View Window |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Internal Dimensions (mm) | 500×500×400 to 1000×1000×1000 |
| Temperature Range | 0–100°C (optional up to 150°C) |
| Black Panel Temperature | 40–85°C |
| Humidity Range (Light Cycle) | 20–75% RH |
| (Dark Cycle) | 20–98% RH |
| Temperature Uniformity | ±2.0°C |
| Temperature Stability | ±0.5°C |
| Humidity Uniformity | ±3.0% RH |
| Humidity Stability | ±2.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1120 W/m² ±10% (300–1200 nm or 300–3000 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – 1.2 mm SUS304 stainless steel |
| Safety Protections | Over-temperature, compressor high/low pressure, short-circuit, overload, oil-pressure, travel limit, and leakage current protection |
| Optional Accessories | Ø50 mm cable port, SUS316 sample trays, liquid nitrogen inlet |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Lamp Life | ~1,600 h at standard irradiance |
| Spectral Range | 300–1200 nm |
| Rated Power | 1.8–6 kW |
| Irradiance Control | 550 W/m² (300–800 nm) ±10% |
| Cooling | Forced-air |
| Filter System | Long-life optical filters for solar-spectrum fidelity |
| Brand | OK |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (FOB) |
| Chamber Capacity | 100–1000 L |
| Light Source | Long-Arc Air-Cooled Xenon Lamp |
| Spectral Range | 300–1200 nm |
| Irradiance Control | 300–800 nm @ 550 W/m² ±10% |
| Black Panel Temperature | 40–85 °C |
| Cabinet Temperature | 0–150 °C |
| Humidity Range (Light Cycle) | 20–75 %RH |
| Humidity Range (Dark Cycle) | 20–98 %RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 %RH |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 %RH |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500-mm-diameter rotating turntable (0–3 rpm) |
| Internal Construction | SUS304 stainless steel |
| External Construction | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Lamp Life | ≈1,500 h at nominal irradiance |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (FOB, indicative only |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +85 °C |
| Humidity Range | 10–98% RH |
| Temperature Uniformity | ±3 °C |
| Humidity Uniformity | ±3% RH |
| Temperature Fluctuation | ±3 °C |
| Humidity Fluctuation | ±3% RH |
| Rainfall Duration | 0–9999 min (continuous) |
| Rainfall Cycle | 0–240 min (intermittent) |
| Xenon Lamp Power | 6 kW |
| Spectral Range | 290–400 nm |
| Irradiance Control | 315 nm band (±5%) |
| Sample Rack Rotation | 1 rpm, 360° |
| Sample-to-Lamp Distance | 300–375 mm |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (D×W×H) |
| Refrigerant | R404A |
| Compressor | Hermetic French Tecumseh Unit |
| Cooling Method | Air-Cooled, Single-Stage |
| Compliance | GB/T 16422.2–1999, GB/T 1865–2007, GB/T 2423.24–1995, ASTM G155, ISO 105-B02/B04, SAE J2527, SAE J2412 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +100 °C |
| Humidity Range | 10–98% RH |
| Humidity Uniformity | ±3% RH |
| Temperature Uniformity | ±2 °C |
| Rainfall Duration | 0–9999 min (continuous) |
| Rainfall Cycle | 0–240 min (intermittent) |
| Xenon Lamp Power | 6 kW ±5% |
| Spectral Range | 290–400 nm |
| Irradiance Control | 0.35–0.65 W/m²/nm @ 340 nm |
| Sample Rack Rotation | 1 rpm, 360° |
| Lamp-to-Sample Distance | 300–375 mm |
| Refrigerant | R404A |
| Cooling System | Air-cooled, hermetic French Tecumseh compressor |
| Humidity Control | Direct steam injection + dew-point contact dehumidification |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, SAE J2412, GB/T 16422.2, GB/T 1865, IEC 60068-2-5 |
| Brand | OK |
|---|---|
| Model | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Chamber Type | Benchtop to Floor-Standing Xenon Arc Exposure System |
| Light Source | Long-Arc Air-Cooled Xenon Lamp (Full-Spectrum Solar Simulation) |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Black Panel Temperature Range | 40–85°C |
| Chamber Temperature Range | 0–150°C |
| Humidity Control | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Humidity Accuracy | ±2.0% RH |
| Temperature Accuracy | ±0.5°C |
| Uniformity | ±2.0°C (temp), ±3.0% RH (humidity) |
| Irradiance Control | Closed-loop digital feedback with calibrated broadband sensor |
| Water Spray | Programmable intermittent/continuous mode (1–999 min), pressure 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Lamp Life | ~1500 h at rated irradiance |
| Filter System | Precision daylight-filtered quartz envelope for stable CIE standard solar spectrum replication |
| Compliance | ASTM G155, ISO 4892-2, GB/T 16422.2, GB/T 8427, GB/T 8430, GB/T 14576, GB/T 15102–2006, GB/T 15104–2006, AATCC TM16, JIS D 0205 |
| Brand | OK Instruments |
|---|---|
| Model | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Type | Benchtop Xenon Arc Environmental Test Chamber |
| Light Source | Long-Arc Air-Cooled Xenon Lamp (1.8–6 kW) |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Black Panel Temperature Range | 40–85°C |
| Chamber Temperature Range | 0–150°C |
| Humidity Control | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Humidity Accuracy | ±2.0% RH |
| Temperature Accuracy | ±0.5°C |
| Uniformity | ±2.0°C (temp), ±3.0% RH (humidity) |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Lamp Life | ~1500–1600 hours |
| Filter System | Precision broadband optical filters for solar-spectrum simulation |
| Compliance | Designed to support ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, and GB/T 16422.2 test protocols |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,950 (FOB) |
| Temperature Range | 105–135 °C (up to 143 °C optional) |
| Humidity Range | 70–100 % RH |
| Pressure Range | 0.0–2.0 kg/cm² (gauge), relative to ambient atmospheric pressure |
| Internal Dimensions (Φ×H, mm) | Φ250×300 / Φ300×450 / Φ450×500 / Φ650×600 |
| External Dimensions (W×H×D, mm) | 500×500×700 / 580×850×650 / 800×750×900 / 950×900×1100 |
| Safety Systems | Low-water cutoff, overpressure relief, interlocked door safety switch, automatic venting |
| Power Supply | AC 220 V / 380 V, 50/60 Hz |
| Standard Accessories | Two stainless-steel adjustable shelves |
| Compliance | Designed per JEDEC JESD22-A108, JESD22-A110, and IEC 60068-2-66 test methodologies |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (Reference Only) |
| Internal Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| Sample Tray Size | 530 × 730 mm |
| Temperature Range | 40–80 °C (adjustable) |
| Humidity Range | 40–95 %RH (adjustable) |
| Black Panel Temperature | 40–100 °C ±3 °C |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Xenon Lamp | 2 kW single-lamp configuration |
| Lamp Life | 1000 h |
| Irradiance Spectrum | 290–800 nm |
| Sample-to-Lamp Distance | 230–280 mm |
| Rain Cycle Time | 0–9999 min (continuous) |
| Intermittent Rain Interval | 0–240 min |
| Water Spray Cycle | 18 min ON / 102 min OFF or 12 min ON / 48 min OFF |
| Spray Pressure | 0.12–0.15 MPa |
| Nozzle Orifice | Ø0.8 mm |
| Heating Power | 2 kW |
| Humidification Power | 1.2 kW |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,950 (FOB) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Safety Protections | Leakage, Short-Circuit, Overtemperature, Motor Overheat, Overcurrent |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (FOB, ex-works reference only |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | 0K-XD-1000 |
| Xenon Lamp Power | 6 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Exposure Cycle | 1–999 h/min/sec (programmable) |
| Humidity Range (Light Cycle) | 20–75% RH |
| Compliance | ISO 4892-2, ASTM G155, SAE J2527, GB/T 16422.2 |
| Control System | Programmable Logic Controller (PLC) with real-time irradiance feedback |
| Cooling | Forced-air + water-cooled xenon lamp assembly |
| Filter Options | Daylight-Q, Window Glass-Q, Extended UV-Q |
| Sample Rotation | 360° motorized turntable |
| Black Panel Temperature Range | 30–110°C |
| Air Temperature Range | 10–80°C |
| Spray Function | Deionized water spray with adjustable frequency/duration |
| Data Logging | Time-stamped parameter history (irradiance, temp, RH, spray status) |
| Brand | OK Instruments |
|---|---|
| Model | OK-XD-400 |
| Interior Dimensions (W×H×D) | 470 × 750 × 460 mm |
| Inner Liner Material | SUS304 Stainless Steel |
| Outer Casing | Powder-Coated A3 Steel |
| Temperature Range | RT+10°C to 90°C (±2°C) |
| Black Panel Temperature Range | RT+10°C to 120°C |
| Humidity Range | 45–98% RH (±5% RH) |
| Rainfall Duration | 0–9999 min (continuously adjustable) |
| Light Source | Air-Cooled Xenon Arc Lamp |
| Lamp Power | 5.4 kW |
| Spectral Output | 290–850 nm |
| Sample Holder Capacity | 26 positions, each 200 × 60 mm |
| Compliance | GB/T 16422.2, GB/T 8430, GB/T 1865, GB/T 16259, GB/T 5137.3, GB/T 2423.24, ASTM D4459 |
| Key | Temperature Uniformity: ±2°C |
|---|---|
| Temperature Fluctuation | ±0.5°C |
| Operating Temperature Range | RT+10°C to 70°C |
| Humidity Range | 90–98% RH |
| Internal Chamber Dimensions (W×H×D) | 450 × 1170 × 500 mm |
| Effective Irradiation Area | 900 × 210 mm |
| Black Panel Temperature Range | 40–65°C |
| UV Spectrum | UV-A (315–400 nm), UV-B (280–315 nm) |
| Sample-to-Lamp Distance | 50 mm |
| Lamp Center Spacing | 70 mm |
| Standard Specimen Size | 75 × 150 mm or 75 × 300 mm |
| Exposure Time Range | 0–999 h |
| Condensation Cycle Control | Adjustable |
| Control Method | PID Auto-Tuning |
| Water Tray Depth | 25 mm (Auto-Maintained) |
| Power Supply | AC 380 V ±10%, 50 ±0.5 Hz, 3-phase 5-wire |
| Ambient Operating Conditions | 5–30°C, ≤85% RH |
| Construction | Exterior – Powder-Coated Carbon Steel or SUS304 Brushed Stainless Steel |
| Safety Protections | Overtemperature, Leakage Current, Short Circuit, Motor Overheat, Overcurrent, Low-Water Level Detection |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300–12,800 (FOB, model-dependent) |
| Internal Chamber Dimensions (L×W×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 hours |
| Spray Cycle Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer wire mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (FOB Reference) |
| Chamber Volume | 225 L |
| Internal Dimensions (H×W×D) | 500 × 750 × 600 mm |
| External Dimensions (W×H×D) | 1260 × 1500 × 1100 mm |
| Temperature Range | RT+10°C to 80°C (adjustable) |
| Black Panel Temperature | 63°C or 100°C ±3°C |
| Humidity Range | 45–90% RH (adjustable) |
| Temperature Uniformity | ±0.5°C |
| Irradiance Control | 550 W/m² (290–800 nm) |
| Spectral Filter | <255 nm blocked |
| Lamp Type | 2.5 kW DC air-cooled xenon arc lamp (single tube) |
| Lamp Lifetime | 800–1000 h |
| Sample Tray Size | 450 × 720 mm |
| Rain Cycle Timer | 0–9999 min (continuous) / 0–240 min (interval) |
| Nozzle Orifice | Ø0.8 mm |
| Total Power Consumption | ~9.0 kW |
| Compliance | GB/T 16422.2, ASTM D529, ISO 4892-2 |
| Brand | OK |
|---|---|
| Model | OK-XD-200 |
| Chamber Type | Xenon Arc Environmental Aging Chamber |
| Effective Irradiation Area | 900 × 210 mm (W × H) |
| Standard Specimen Size | 75 × 150 mm or 75 × 300 mm |
| UV Irradiance | UVB-313: 0.55 W/m², UVA-340: 0.68 W/m² |
| Temperature Resolution | 0.1 °C |
| Light Cycle Temperature Range | 50–70 °C (±3 °C tolerance) |
| Condensation Temperature Range | 40–60 °C (±3 °C tolerance) |
| Black Panel Temperature Range | 30–80 °C (±1 °C tolerance) |
| Humidity Range (Light Cycle) | 30–80 %RH |
| (Dark Cycle) | up to 90 %RH |
| Relative Humidity During Exposure | 85–98 %RH |
| Wavelength Range | UV-A: 315–400 nm |
| Lamp Center-to-Center Spacing | 70 mm |
| Specimen-to-Lamp Distance | ~50 mm |
| Chamber Dimensions (H×W×D) | ~1550 × 1350 × 510 mm |
| Construction Material | AISI 304 Stainless Steel (Interior & Exterior) |
| Humidity System | Steam-based, SUS304 stainless steel humidifier and reservoir with auto water-level control |
| Heating Element | Stainless steel electric heating tubes |
| Humidity Sensor | Dry-wet bulb type |
| Sample Rack | Stainless steel and aluminum mesh frame |
| Compliance Standards | ASTM D4329, D4587, D5208, G154, G53 |
Show next