| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OK-HC-900 |
| Sand Composition | 97–99% SiO₂ (silicon dioxide) |
| Sand Blowing Concentration | 1.1 g/m³ ± 0.25 g/m³ to 2.2 g/m³ ± 0.5 g/m³ |
| Sand Blowing Velocity | 0–29 m/s |
| Dust Blowing Concentration | 0.1–10.6 g/m³ ± 7 g/m³ |
| Dust Blowing Velocity | 8.9 m/s ± 1.2 m/s |
| Internal Chamber Dimensions | 90 × 90 × 90 cm |
| Temperature Range | 20 °C ± 15 °C (ambient) |
| Relative Humidity | 45–90 % RH |
| Test Duration | 0–99 h |
| Dust Type | Talcum powder or standardized test dust (particle size ≤ 75 µm |
| nominal wire diameter of sieve mesh | 50 µm) |
| Air Pressure Control | Bottom-mounted pneumatic dust dispersion with adjustable pressure and free-fall sedimentation |
| Power Supply | AC 220 V ± 5 % / 50 Hz ± 0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000 (FOB) |
| Temperature Transition Time (Hot-to-Cold / Cold-to-Hot) | ≤10 s |
| Temperature Recovery Time in Test Zone | ≤5 s |
| Control Interface | 302×240-dot Color Touch LCD with Bilingual (EN/CN) Microprocessor Controller |
| Program Storage Capacity | 100 Programs, up to 9999 Cycles, Max Segment Duration: 999 h 59 min |
| Communication Interfaces | RS-232C, RS-485 (optional), Ethernet (optional) |
| Refrigeration System | Dual-stage HFC-based Cryogenic System |
| Compliance Standards | MIL-STD-810H, IEC 60068-2-14, JIS Z 8702 |
| Brand | OK |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -10 °C to 80 °C (standard), optional down to -20 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Rainfall Intensity | 25 mm/h |
| Nozzle Orifice Diameter | φ0.4 mm |
| Droplet Diameter | 1.0–1.5 mm |
| Ice Accumulation Thickness Options | 6 mm, 13 mm, 37 mm, 75 mm |
| Ice Density Range | 0.2–0.9 g/cm³ |
| Water Temperature Control | 0–5 °C |
| Inner Chamber Material | SUS304 Stainless Steel |
| Outer Chamber Material | Galvanized Steel with Powder Coating or Optional SUS304 |
| Refrigeration System | Hermetic Scroll Compressor (French/Tecumseh) |
| Controller | 5.7″ TFT Color LCD Touchscreen (Bilingual English/Chinese) |
| Power Supply | AC 220 V ±5%, 50 Hz ±0.5 Hz, Single-Phase Three-Wire |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,500 (FOB) |
| Internal Dimensions (mm) | KS-TH-100: 450×450×500 |
| KS-TH-225 | 500×600×750 |
| KS-TH-500 | 700×800×900 |
| KS-TH-800 | 800×1000×1000 |
| KS-TH-1000 | 1000×1000×1000 |
| Temperature Range | −70 °C to +150 °C |
| Ramp Rate | Up to 10 °C/min (typical, load-dependent) |
| Uniformity | ±0.5 °C (at steady state, per IEC 60068-3-5) |
| Stability | ±0.3 °C |
| Control System | Fuzzy PID programmable controller with RS232 interface |
| Refrigerant | R-404A (ozone-friendly, non-CFC) |
| Air Circulation | Forced convection via high-efficiency EBM centrifugal blower and annular airflow duct |
| Safety Features | Independent overtemperature limiter, leakage current protection, door-open alarm, power-failure recovery, sensor fault detection |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range (optional) | 20–98% RH |
| Rapid TC Range | -45°C to +85°C |
| Rapid TC Accuracy | ±3.0°C |
| Ramp Rates | 5–30°C/min (selectable A–F types) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.5% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Temp. Resolution | 0.1°C |
| Humidity Resolution | 0.1% RH |
| Construction | SUS304 inner chamber, stainless steel or SECC cold-rolled steel with powder coating outer shell |
| Insulation | High-density polyurethane foam |
| Cooling | Water-cooled |
| Compressor Options | Tecumseh (France), Bitzer (Germany) |
| Power Supply | AC380V, 3-phase 5-wire, 50/60 Hz |
| Weight Range | 950–2300 kg |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.5, GJB 360.7, IEC 60068-2-14 (Test N), QC/T 17, EIA-364-32 |
| Safety Protections | High/low pressure cut-off, over-temperature/over-humidity protection, compressor overload protection, fuse, water shortage alarm, fault warning system |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-HC-900.0200 |
| Test Dust Composition | 97–99% crystalline silica (SiO₂) |
| Dust Concentration (Blowing) | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Air Velocity (Blowing) | 0–29 m/s |
| Dust Concentration (Dust Suspension) | 0.1–10.6 g/m³ ±7 g/m³ |
| Air Velocity (Dust Suspension) | 8.9 m/s ±1.2 m/s |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | OK-HC-900.00 |
| Silica Content of Test Dust | 97–99% SiO₂ |
| Sand Blowing Concentration | 1.1 g/m³ ± 0.25 g/m³ to 2.2 g/m³ ± 0.5 g/m³ |
| Sand Blowing Velocity | 0–29 m/s |
| Dust Blowing Concentration | 0.1–10.6 g/m³ ± 7 g/m³ |
| Dust Blowing Velocity | 8.9 m/s ± 1.2 m/s |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Model | OK-LY-500C |
| Price | USD 3,650 (approx.) |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-HC-900.0 |
| Silica Content of Test Dust | 97–99% SiO₂ |
| Sand Blowing Concentration | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Sand Blowing Air Velocity | 0–29 m/s |
| Dust Blowing Concentration | 0.1–10.6 g/m³ ±7 g/m³ |
| Dust Blowing Air Velocity | 8.9 m/s ±1.2 m/s |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 12,500 (FOB) |
| Chamber Interior Dimensions (D×W×H) | 900 × 600 × 500 mm |
| External Dimensions (D×W×H) | 1410 × 880 × 1280 mm |
| Heating Power | 1.3–1.8 kW |
| Temperature Range | +5°C to 55°C |
| Humidity Range | 85–95% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Continuous or Cyclic Programmable |
| Timer Range | 1 sec to 999 hours |
| Heating System | U-shaped Titanium Alloy Immersion Heater |
| Temperature Controller | High-Precision Digital PID Microcomputer Controller (±0.1°C Accuracy) |
| Sensor | PT100 Platinum Resistance Thermometer |
| Viewing Window | Full-Transparent Impact-Resistant Acrylic Lid with Water-Sealed Joint |
| Actuation | Pneumatic Lid Support Mechanism |
| Interior & Exterior Construction | Reinforced PVC Rigid Plastic Panels (UV-stabilized, corrosion-resistant, aging-resistant) |
| Included Accessories | One SO₂ Gas Cylinder (with Regulator) |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-HC-1000.02 |
| Silica Content | 97–99% SiO₂ |
| Dust Concentration (IP5X) | 0.1–10.6 ±7 g/m³ |
| Dust Velocity | 8.9 ±1.2 m/s |
| Sand Concentration (IP6X) | 1.1 ±0.25 to 2.2 ±0.5 g/m³ |
| Sand Velocity | 0–29 m/s |
| Chamber Construction | SUS 304 Stainless Steel Interior |
| Compliance | IEC 60529, GB/T 4208, ISO 20653, MIL-STD-810G/H Method 510.5, GJB 150.12A |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-HC-1000 |
| Sand Composition | 97–99% SiO₂ (silicon dioxide) |
| Sand Blowing Concentration | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Sand Blowing Velocity | 0–29 m/s |
| Dust Blowing Concentration | 0.1–10.6 g/m³ ±7 g/m³ |
| Dust Blowing Velocity | 8.9 m/s ±1.2 m/s |
| Brand | OK |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Import Status | Domestic Production with International Compliance Design |
| Price | USD 14,000 (FOB China) |
| Internal Dimensions (W×H×D) | 50×75×60 cm to 100×100×100 cm |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20–98 %RH (optional: 5–98 %RH) |
| Rapid TC Range | −45 °C to +85 °C or −20 °C to +85 °C |
| Ramp Rates | 5–25 °C/min (user-selectable) |
| Temp. Uniformity | ±2 °C |
| Humidity Uniformity | ±3.0 %RH (≥75 %RH) |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2.5 %RH |
| Construction Material | SUS304 Stainless Steel |
| Refrigeration System | Hermetic Dual-Stage Compressor with R404A/R23 Eco-Friendly Refrigerants |
| Controller | Touchscreen LCD with English/Chinese Interface |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Brand | OK |
|---|---|
| Model | HC-900 |
| Type | Ingress Protection (IP) Sand and Dust Test Chamber |
| Internal Dimensions | 900 × 900 × 900 mm (W×H×D) |
| External Dimensions | 1550 × 1800 × 1300 mm (W×H×D) |
| Weight | 320 kg |
| Temperature Range | 20 °C ±15 °C |
| Humidity Range | 45–85 %RH |
| Dust Concentration Options | F1: 60,000 mg/m³ |
| F2 | 3,000 mg/m³ |
| F3 | 100 mg/m³ |
| C1 (Flowing Dust) | 5,000 mg/m³ at 5 m/s |
| C2 (Flowing Dust) | 100 mg/m³ at 5 m/s |
| Test Duration | 0–99 hr (time control), 0–999 sec (cycle control) |
| Power Supply | 220 V AC, single-phase, 5 kW |
| Brand | OK |
|---|---|
| Origin | China (Manufactured in Huzhou) |
| Manufacturer Type | OEM/ODM Manufacturer |
| Compliance | GB/T 2423, GJB 150, GB 10589, GB 11158, GB 10592 |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20–98 %RH (optional: 5–98 %RH) |
| Rapid TC Range Options | −45 °C to +85 °C or −20 °C to +85 °C |
| Ramp Rates | 5–25 °C/min (user-selectable) |
| Temp. Uniformity | ±2 °C |
| Humidity Uniformity | ±3.0 %RH (at ≥75 %RH) |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2.5 %RH |
| Interior Material | SUS#304 Stainless Steel |
| Refrigeration System | Hermetic Dual-Stage Compressor (R404A/R23) |
| Controller | Touchscreen LCD with English/Chinese UI |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | OK-HC-800 |
| Sand Composition | 97–99% SiO₂ (quartz silica) |
| Dust Concentration Range | 0.1–10.6 ±7 g/m³ |
| Dust Velocity | 8.9 ±1.2 m/s |
| Sand Concentration Range | 1.1 ±0.25 g/m³ to 2.2 ±0.5 g/m³ |
| Sand Velocity | 0–29 m/s |
| Compliance | GB/T 4208 (IP5X, IP6X), IEC 60529 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-HC-900.0000 |
| Silica Content | 97–99% SiO₂ |
| Sand Blowing Concentration | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Sand Blowing Velocity | 0–29 m/s |
| Dust Blowing Concentration | 0.1–10.6 g/m³ ±7 g/m³ |
| Dust Blowing Velocity | 8.9 m/s ±1.2 m/s |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-HC-800.00 |
| Silica Content | 97–99% SiO₂ |
| Dust Concentration Range | 0.1–10.6 ± 7 g/m³ |
| Dust Velocity | 8.9 ± 1.2 m/s |
| Sand Concentration Range | 1.1 ± 0.25 to 2.2 ± 0.5 g/m³ |
| Sand Velocity | 0–29 m/s |
| Compliance | IP5X/IP6X, ISO 20653, MIL-STD-810G/H, GJB 150.12A |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-SC-500C |
| Silica Content | 97–99% SiO₂ |
| Blowing Sand Concentration | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Sand Blowing Velocity | 0–29 m/s |
| Blowing Dust Concentration | 0.1–10.6 g/m³ ±7% |
| Dust Blowing Velocity | 8.9 m/s ±1.2 m/s |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-HC-900.02 |
| Silica Content | 97–99% SiO₂ |
| Sand Blowing Concentration | 1.1 g/m³ ± 0.25 g/m³ to 2.2 g/m³ ± 0.5 g/m³ |
| Sand Blowing Velocity | 0–29 m/s |
| Dust Blowing Concentration | 0.1–10.6 g/m³ ± 7 g/m³ |
| Dust Blowing Velocity | 8.9 m/s ± 1.2 m/s |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 5,200 (Reference Only |
| Xenon Lamp Power | 6 kW |
| Lamp Life | ~1,600 hours |
| Irradiance Range | 550–1,200 W/m² |
| Spectral Range | 290–800 nm |
| Irradiated Area | ~0.75 m² |
| Sample-to-Arc Distance | 350–380 mm |
| Sample Rotation Speed | ≥1 rpm (Infinitely Variable) |
| Rainfall Duration | 1–9,999 min (Adjustable) |
| Rainfall Cycle Interval | 1–240 min (Adjustable) |
| Heating Power | ~3.6 kW |
| Humidification Power | ~3 kW |
| Refrigeration Compressor | 1× Hermetic Tecumseh (France) |
| Refrigerant | R404A |
| Cooling Method | Forced Air |
| Humidity Control | Relative Humidity (RH) Regulation |
| Heating Element | Stainless Steel Finned-Tube Heater with SSR Output Control |
| Lamp Type | Imported Water-Cooled Full-Spectrum Long-Arc Xenon Lamp |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-HC-900.123 |
| Silica Content | 97–99% SiO₂ |
| Dust Concentration (Blowing) | 0.1–10.6 ±7 g/m³ |
| Dust Velocity | 8.9 ±1.2 m/s |
| Sand Concentration | 1.1 ±0.25 g/m³ to 2.2 ±0.5 g/m³ |
| Sand Velocity | 0–29 m/s |
| Compliance | IEC 60529, GB/T 4208, ISO 20653, MIL-STD-810G/H Method 510.5, GJB 150.12A |
| Key | Internal Chamber Dimensions: 40 × 35 × 30 cm |
|---|---|
| High-Temperature Zone Range | RT to +100 °C |
| Low-Temperature Zone Range | −40 °C to −10 °C |
| Thermal Shock Range | +100 °C / −40 °C |
| Ramp Rate (Heating) | ~15 min from RT to +100 °C |
| Ramp Rate (Cooling) | ~60 min from RT to −40 °C |
| Dwell Time per Cycle | 0.1–999.9 h |
| Cycle Count Programmable | 1–9999 |
| Recovery Time after Shock | ≤5 min |
| Max. Sample Mass | 1.5 kg |
| Construction | Exterior & Interior – SUS304 brushed stainless steel (interior mirror finish) |
| Refrigeration System | Dual-stage cascade refrigeration, water-cooled, hermetic or semi-hermetic compressors (EU/US origin) |
| Controller | Full-color LED touchscreen HMI with PID auto-tuning |
| Safety Protections | Overcurrent fuses, compressor overheat/overpressure/overcurrent protection, dry-heater alarm, chamber overtemperature alarm |
| Standard Accessories | One φ50 mm test port, two sample racks |
| Refrigerants | R404A / R23 (zero ODP, low GWP HFC blends) |
Show next