Empowering Scientific Discovery

Guangdong Oak Detection Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOther Brands
OriginImported
Manufacturer TypeGeneral Distributor
PriceUSD 6,300 (approx.)
Temperature Range25–40 °C
Humidity Range30–65 %RH
Ozone Concentration Range50–1500 pphm
Temp. Uniformity±0.5 °C
Sample Rack360° continuous rotation at 1 rpm
Gas Flow Velocity8–16 mm/s
Control SystemWeilun color touchscreen + Siemens PLC
Ozone GenerationSilent discharge tube
Ozone DetectionNondispersive UV absorption sensor (≥5 yr lifespan)
ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Other Brands
OriginImported
Manufacturer TypeGeneral Distributor
Ozone Concentration Range50–1500 ppm (pphm)
Temperature Range25–40 °C
Humidity Range30–65 % RH
Temp. Uniformity±0.5 °C
Sample MountingDynamic (360° rotation at 1 rpm) & Static options
Gas Flow Velocity8–16 mm/s
Control SystemSiemens PLC + Weintek Color Touchscreen
Ozone DetectionNon-dispersive UV Sensor (≥5 yr lifespan)
ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOEM
OriginImported
Manufacturer TypeAuthorized Distributor
PriceUSD 6,300 (FOB)
Temperature Range25–40 °C
Humidity Range30–65 %RH
Ozone Concentration Range50–1500 pphm
Temp. Uniformity±0.5 °C
Sample Rack360° continuous rotation at 1 rpm
Gas Flow Velocity8–16 mm/s
Control SystemWeilun color touchscreen + Siemens S7-1200 PLC
Ozone SensorNon-dispersive UV absorption type, ≥5-year service life
ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOEM
OriginImported
Manufacturer TypeAuthorized Distributor
PriceUSD 6,200 (FOB Shanghai, ex-works reference only)
ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Chamber Volume Options80 L / 225 L / 500 L / 1000 L
Temperature Range25–40 °C
Temp. Uniformity±0.5 °C
Humidity Range30–65 % RH
Ozone Concentration Range50–1500 pphm
Ozone Generation MethodSilent Discharge Tube
Ozone MonitoringNon-Dispersive UV Absorption Analyzer (Lifespan ≥5 years)
Sample Rotation360° motorized turntable, 1 rpm (static/dynamic test modes optional)
Gas Flow Velocity8–16 mm/s
Control SystemWeilun color touchscreen + Siemens S7-1200 PLC
Communication InterfaceRS232, 4–20 mA analog output
Safety ProtectionsLeakage current, short-circuit, overtemperature, motor overheat, overcurrent
Power SupplyAC 380 V ±5 %, 50 Hz ±0.5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
Key FeaturesStainless steel sealed test chamber
Ozone concentration range50–1500 ppm (pphm)
Temperature range25–40 °C
Humidity range30–65 %RH
Temp. uniformity±0.5 °C
Sample rotation360°, 1 rpm
Gas flow velocity8–16 mm/s
Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-12004
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOther Brands
OriginImported
Manufacturer TypeAuthorized Distributor
Ozone Concentration Range50–1500 ppm (pphm)
Temperature Range25–40 °C
Humidity Range30–65 % RH
Temp. Uniformity±0.5 °C
Sample Rack360° Rotational (1 rpm), Static or Dynamic Mode Optional
Ozone GenerationSilent Discharge Tube
Ozone DetectionNondispersive UV Absorption Analyzer (≥5 yr lifespan)
Control SystemWeilun Color Touchscreen + Siemens PLC
Output/Interface4–20 mA analog output, RS232 communication port
Safety ProtectionLeakage current, short-circuit, overtemperature, motor overheat, and overcurrent protection
Power SupplyAC 380 V ±5 %, 50 Hz ±0.5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
Key FeaturesStainless steel test chamber
Humidity control30–65% RH
Rotating sample rack1 rpm, 360° continuous rotation
Gas flow velocity8–16 mm/s
Compliant with GB/T 7762-2003, GB/T 2951.21-2008, GB/T 11206-2009, ISO 1431-12004
Electrical supplyAC 380 V ±5%, 50 Hz ±0.5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOther Brands
OriginImported
Manufacturer TypeAuthorized Distributor
Ozone Concentration Range50–1500 ppm (pphm)
Temperature Range25–40 °C
Humidity Range30–65% RH
Temperature Uniformity±0.5 °C
Sample Rotation Speed1 rpm (360° continuous rotation)
Gas Flow Velocity8–16 mm/s
Compliance StandardsGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Control SystemSiemens PLC + Weintek Color Touchscreen HMI
Ozone GenerationSilent Discharge Tube
Ozone DetectionNon-Dispersive UV Absorption Analyzer (≥5 yr service life)
Safety FeaturesLeakage protection, short-circuit cutoff, overtemperature shutdown, motor thermal overload protection
Power SupplyAC 380 V ±5%, 50 Hz ±0.5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOther Brands
OriginImported
Manufacturer TypeGeneral Distributor
PriceUSD 6,200 (approx.)
Chamber Volume Options80 L / 225 L / 500 L / 1000 L
Temperature Range25–40 °C
Humidity Range30–65 % RH
Ozone Concentration Range50–1500 pphm
Ozone Generation MethodSilent Discharge Tube
Ozone MonitoringNon-Dispersive UV Sensor (≥5 yr lifespan)
Control SystemSiemens PLC + Weintek Color Touchscreen
Temperature Stability±0.5 °C
Sample Rotation360° motorized rack, 1 rpm
Gas Flow Velocity8–16 mm/s
Compliance StandardsGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
Key SpecificationsBrand: OEM / Industrial Grade
OriginImported
Temperature Range25–40 °C
Humidity Range30–65 %RH
Ozone Concentration Range50–1500 pphm
Temp. Uniformity±0.5 °C
Sample Rotation Speed1 rpm (360° continuous)
Gas Flow Velocity8–16 mm/s
Ozone GenerationSilent Discharge Tube
Ozone DetectionNondispersive UV Absorption Analyzer (≥5 yr service life)
Control SystemWeilun Color Touchscreen + Siemens PLC
ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
SafetyFully Enclosed Ozone Loop, Leakage Protection, Over-Temp/Over-Current/Motor Thermal Cut-off
Interface4–20 mA analog output, RS232 communication port
Power SupplyAC 380 V ±5 %, 50 Hz ±0.5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOther Brands
OriginImported
Manufacturer TypeGeneral Distributor
PriceUSD 6,300 (approx.)
Chamber Volume Options80 L / 225 L / 500 L / 1000 L
Temperature Range25–40 °C
Humidity Range30–65 % RH
Ozone Concentration Range50–1500 pphm
Temp. Uniformity±0.5 °C
Sample Rack360° continuous rotation at 1 rpm
Gas Flow Velocity8–16 mm/s
Ozone GenerationSilent Discharge Tube
Ozone DetectionNon-Dispersive UV Absorption Analyzer (≥5 yr lifespan)
Control SystemWeilun Color Touchscreen + Siemens PLC
Compliance StandardsGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOEM
OriginImported
Manufacturer TypeAuthorized Distributor
PriceUSD 6,300 (FOB)
Standards ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Chamber Volume Options80 L / 225 L / 500 L / 1000 L
Temperature Range25–40 °C
Humidity Range30–65 %RH
Ozone Concentration Range50–1500 ppm (pphm)
Temp. Uniformity±0.5 °C
Sample Rotation360° continuous, 1 rpm
Gas Flow Velocity8–16 mm/s
Ozone GenerationSilent Discharge Tube
Detection MethodNon-Dispersive UV Absorption
Sensor Lifetime≥5 years
Control SystemWeilun Color Touchscreen + Siemens S7-1200 PLC
Output Interface4–20 mA analog, RS232 serial
Safety ProtectionsLeakage current, short-circuit, overtemperature, motor overheat, overcurrent
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOther Brands
OriginImported
Manufacturer TypeGeneral Distributor
PriceUSD 6,300 (approx.)
Temperature Range25–40 °C
Humidity Range30–65 %RH
Ozone Concentration50–1500 pphm
Temp. Uniformity±0.5 °C
Sample Rack360° rotation at 1 rpm
Gas Flow Velocity8–16 mm/s
Control SystemWeilun color touchscreen + Siemens PLC
Ozone SensorNondispersive UV absorption type, ≥5-year service life
ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOEM
OriginImported
Manufacturer TypeAuthorized Distributor
PriceUSD 6,300 (FOB)
Standards ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Chamber Volume Options80 L / 225 L / 500 L / 1000 L
Temperature Range25–40 °C
Humidity Range30–65 %RH
Ozone Concentration Range50–1500 pphm
Temp. Uniformity±0.5 °C
Ozone GenerationSilent Discharge Tube
Ozone DetectionNon-Dispersive UV Absorption Analyzer (Lifespan ≥5 yr)
Sample Rotation360° motorized rack, 1 rpm
Gas Flow Velocity8–16 mm/s
Control SystemWeilun color touchscreen + Siemens S7-1200 PLC
Safety ProtectionsLeakage, short-circuit, over-temperature, motor overheat, over-current
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: OEM
OriginImported
Manufacturer TypeAuthorized Distributor
PriceUSD 6,300 (FOB ex-works
Chamber Volume Options80 L / 225 L / 500 L / 1000 L
Temperature Range25–40 °C ±0.5 °C
Humidity Range30–65 % RH
Ozone Concentration Range50–1500 pphm (parts per hundred million)
Ozone Generation MethodSilent Discharge Tube
Ozone MonitoringNon-Dispersive UV Absorption Analyzer (≥5 yr service life)
Control SystemWeilun Color Touchscreen + Siemens PLC
Sample MotionStatic or Dynamic (360° rotation at 1 rpm, cycloidal trajectory compliant)
Gas Flow Velocity8–16 mm/s
Compliance StandardsGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Safety FeaturesLeak-proof closed-loop ozone circulation, over-temperature, over-current, motor thermal, and short-circuit protection
InterfaceRS232 communication port, 4–20 mA analog output, metrology calibration port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOEM
OriginImported
Manufacturer TypeAuthorized Distributor
ModelOK-CY-100
Temperature Range25–80 °C
Humidity Range30–65 %RH
Ozone Concentration Range50–1500 pphm
Temperature Uniformity±0.5 °C
Sample Rack360° continuous rotation at 1 rpm
Gas Flow Velocity8–16 mm/s
Control System7-inch color touchscreen + Siemens PLC
Ozone GenerationSilent discharge tube
Ozone DetectionNon-dispersive UV absorption sensor (≥5 yr lifespan)
ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandOEM
OriginImported
Manufacturer TypeAuthorized Distributor
Ozone Concentration Range50–1500 ppmv (pphm)
Temperature Range25–40 °C
Humidity Range30–65% RH
Temp. Uniformity±0.5 °C
Chamber Volumes80 L / 225 L / 500 L / 1000 L
Sample RotationStatic or Optional 360° Rotating Rack (1 rpm)
Ozone GenerationSilent Discharge Tube
Ozone DetectionNondispersive UV Absorption Analyzer (≥5 yr service life)
Control SystemSiemens PLC + Weintek HMI Touchscreen
ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOEM / Custom Brand
OriginImported
Manufacturer TypeAuthorized Distributor
Temperature Range25–40 °C
Humidity Range30–65 % RH
Ozone Concentration Range50–1500 pphm
Temperature Uniformity±0.5 °C
Sample Rack360° continuous rotation at 1 rpm
Gas Flow Velocity8–16 mm/s
Control SystemSiemens PLC + Weintek color touchscreen HMI
Ozone GenerationSilent discharge tube
Ozone DetectionNon-dispersive UV absorption analyzer (≥5-year service life)
Compliance StandardsGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Other Brands
OriginImported
Manufacturer TypeAuthorized Distributor
Ozone Concentration Range50–1500 ppm (pphm)
Temperature Range25–40 °C
Humidity Range30–65 % RH
Temp. Uniformity±0.5 °C
Sample Rotation Speed1 rpm (360° continuous rotation)
Gas Flow Velocity8–16 mm/s
Control SystemSiemens PLC + Weintek Color Touchscreen HMI
Ozone GenerationSilent Discharge Tube
Ozone DetectionNon-Dispersive UV Absorption Analyzer (≥5 yr service life)
ComplianceGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Safety FeaturesLeakage/short-circuit/overheat/motor-overcurrent protection
Interface4–20 mA analog output, RS232 communication port
Calibration PortIntegrated metrology interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOther Brands
OriginImported
Manufacturer TypeGeneral Distributor
PriceUSD 6,300 (FOB)
Chamber Volume Options80 L / 225 L / 500 L / 1000 L
Temperature Range25–40 °C
Humidity Range30–65 % RH
Ozone Concentration Range50–1500 pphm
Ozone Control Accuracy±10 pphm
Temperature Uniformity±0.5 °C
Sample Rotation360° continuous, 1 rpm
Gas Flow Velocity8–16 mm/s
Ozone GenerationSilent Discharge Tube
Ozone DetectionNon-Dispersive UV Absorption Analyzer (Lifespan ≥5 years)
Control SystemWeilun Color Touchscreen + Siemens PLC
Compliance StandardsGB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: OEM / Custom-Built
OriginImported
Manufacturer TypeAuthorized Distributor
PriceUSD 6,300 (FOB)
Chamber Volume80 L / 225 L / 500 L / 1000 L
Internal Dimensions (W×H×D, cm)40×50×40
External Dimensions (W×H×D, cm)100×170×90
Temperature Range25–40 °C
Temp. Uniformity±0.5 °C
Humidity Range30–65 % RH
Ozone Concentration Range50–1500 pphm
Ozone Generation MethodSilent Discharge Tube
Ozone MonitoringImported UV Absorption Analyzer with 4–20 mA Output & RS232 Interface
Sample RackMotor-Driven, 360° Continuous Rotation (1 rpm), Cycloidal Trajectory Compliance
Gas Flow Velocity8–16 mm/s
Control SystemWeintek Color Touchscreen + Siemens S7-1200 PLC
Safety ProtectionsLeakage Current, Short-Circuit, Over-Temperature, Motor Overheat, Over-Current
Power SupplyAC 380 V ±5 %, 50 Hz ±0.5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOK Instruments
OriginGuangdong, China
Manufacturer TypeDirect Manufacturer
ModelOK-CY-100
PriceUSD 4,950 (FOB Guangdong)
Ozone Concentration Range0.01–100 ppm
Control Accuracy±5% of setpoint (closed-loop PID)
Temperature Range20–60 °C (±1 °C stability)
Humidity Range30–80% RH (±3% RH stability)
Static Stretch Range5–40%
Dynamic Stretch Frequency0–0.5 Hz
Chamber Volume100 L
Exhaust TreatmentActivated Carbon + UV Photolysis
ComplianceGB/T 7762-2014, ISO 1431-1:2004, ASTM D1149-19, SAE J1201-2018
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0