- All
- Favorite
- Popular
- Most rated
| Brand | Bioer |
|---|---|
| Model | HB-202 |
| Temperature Range | (Ambient + 5°C) to 105°C |
| Temperature Accuracy | ≤ ±0.5°C |
| Heating Time | ≤ 12 min (20°C to 100°C) |
| Dimensions (L×W×H) | 300 × 200 × 160 mm |
| Net Weight | 2.8–3.2 kg |
| Power Supply | 220 V~, 50 Hz, 120 W |
| Control System | 32-bit microprocessor |
| Drive Mechanism | Brushless DC motor |
| Heating Element | PTC heater |
| Optional Modules | A (40 × 1.5 mL), B (54 × 0.5 mL), C (96 × 0.2 mL), D (24 × φ15 mm), G (26 × 0.5 mL + 24 × 1.5 mL), H (40 × 2.0 mL), J (96-well microplate), E (115 × 73 × 38 mm water bath insert) |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | MB-202 |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Heating Time | ≤ 12 min (varies by block) |
| Oscillation Frequency | 300–3000 rpm |
| Oscillation Amplitude | 3 mm |
| Timer Range | 1 s – 99 h 59 min |
| Power Input | AC 100–240 V, 50/60 Hz, 180 W |
| Dimensions (L×W×H) | 310 × 210 × 145 mm |
| Net Weight | 5.9 kg |
| Block Recognition | Auto-detect (9 standard blocks included) |
| Brand | BIOER |
|---|---|
| Model | MB-102 |
| Temperature Range | 0°C to 100°C (with cooling down to 14°C below ambient, min. setpoint 0°C) |
| Temperature Accuracy | ≤ ±0.5°C |
| Heating Time | ≤12 min (20°C → 100°C) |
| Oscillation Speed | 300–1500 rpm |
| Oscillation Amplitude | 3 mm |
| Timer Range | 1 s – 99 h 59 min |
| Dimensions (L×W×H) | 328 × 166 × 249 mm |
| Net Weight | 8.5 kg |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz, 150 W |
| Standard Blocks | A (40 × 1.5 mL), B (54 × 0.5 mL), C (96 × 0.2 mL), D (24 × φ15 mm), H (40 × 2.0 mL), G (26 × 0.5 mL + 24 × 1.5 mL), J (96-well microplate) |
| Display | Full-color VFD screen |
| Control System | 32-bit microcontroller with PID temperature regulation |
| Cooling Method | Thermoelectric (Peltier) |
| Motor Type | Brushless DC motor |
| Calibration Function | Built-in temperature calibration |
| Momentary Oscillation Mode | Yes |
| Brand | Bioer |
|---|---|
| Model Series | HB-T1, HB-T2, CHB-T1, CHB-T2 |
| Temperature Range | 0°C to 100°C (model-dependent) |
| Temperature Accuracy | ≤ ±0.2°C |
| Heating Time | ≤ 8 min (20°C → 100°C) |
| Dimensions | 150 × 170 × 145 mm (L × W × H) |
| Net Weight | ≤ 2.0 kg |
| Power Input | HB/CHB-T1 & T2: AC 100–240 V, 50/60 Hz |
| Timer Range | 0–99 h 59 min |
| Max Program Steps | 9 |
| Max Cycles per Program | 99 |
| Standard Block Modules | A (20 × 0.5 mL), B (35 × 1.5 mL), C (54 × 0.5 mL), D (96 × 0.2 mL), E (35 × 2.0 mL) |
| Brand | Bioer |
|---|---|
| Model | N3-8 |
| Type | Non-Circulating Heating Water Bath |
| Capacity | 8 L |
| Temperature Range | Ambient ±5°C to 99.9°C |
| Temperature Stability | ±0.2°C at 37°C |
| Display | LED Digital |
| Power Supply | AC 220–240 V, 50/60 Hz, 600 W |
| Internal Chamber Dimensions | 325 × 265 × 150 mm (L×W×H) |
| External Dimensions | 445 × 285 × 316 mm (L×W×H) |
| Safety Features | Low-Water-Level Protection, Over-Temperature Cut-Off, Compressor Overload Protection (for models with optional cooling), Current Overload Protection |
| Brand | Bioer |
|---|---|
| Model | CHB-202 |
| Temperature Range | −10 °C to 105 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Heating Time to 100 °C | ≤ 35 min |
| Dimensions (L×W×H) | 300 × 200 × 160 mm |
| Net Weight | 3.2 kg |
| Power Supply | AC 220 V, 50 Hz, 120 W |
| Display | Full-color VFD |
| Programmable Setpoints | 5 independent temperature points with multi-segment continuous cycling capability |
| Standard Block Compatibility | A (40 × 1.5 mL), B (54 × 0.5 mL), C (96 × 0.2 mL), D (24 × φ15 mm), H (40 × 2.0 mL), G (26 × 0.5 mL + 24 × 1.5 mL), J (96-well microplate), E (water bath insert: 115 × 73 × 38 mm) |
| Timer Range | 1 min – 99 h 59 min |
Show next