- All
- Favorite
- Popular
- Most rated
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SL-6040A |
| Pricing | Available Upon Request |
| Minimum Installation Space | 6.0 × 4.5 × 3.0 m (L×W×H) |
| Floor Levelness Requirement | ≤5 mm per 2 m |
| Layout Zones | Reagent Preparation Area, Specimen Processing Area, PCR Amplification Area |
| Construction Materials | Sandwich Panels (Color-Coated Steel), Aluminum Alloy Structural Framing, Tempered Glass |
| Air Pressure Control | Negative-to-Neutral Gradient Across Zones |
| UV Disinfection | Fixed Ceiling-Mounted UV Lamps in All Zones & Transfer Window |
| Air Handling | Dedicated Exhaust Ducts with Adjustable Return Air Grilles on Exterior Walls and Doors |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Max. Heating Rate | 5°C/s |
| Temperature Accuracy | ≤ ±0.15°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.2°C |
| Display | 10.4″ TFT-LCD capacitive touch screen |
| Cooling Technology | Custom Ferrotec thermoelectric modules |
| Optional Block Surface | Gold-plated (Au) thermal block with TAS (Thermal Alignment System) |
| Connectivity | USB 2.0, RJ45 LAN, Bluetooth 4.0 (with PC wireless control adapter) |
| Temperature Range | 4–105°C |
| Gradient Function | 6 independent zones, adjustable gradient span 0.1–5.0°C per zone |
| Max. Cycle Number | 99 cycles with nested 2-level programming (suitable for nested PCR) |
| Time Increment/Decrement | 0–9 min 59 sec (enables Long PCR protocols) |
| Temp Increment/Decrement | 0–9.9°C (supports Touchdown PCR) |
| Power Input | AC 100–240 V, 50/60 Hz, 800 W |
| Dimensions (L×W×H) | 457 × 316 × 309 mm |
| Net Weight | 14 kg |
| Compatible Consumables | 0.2 mL 96-well PCR plates (full-skirt, half-skirt, unskirted), 0.2 mL single tubes, 0.2 mL 8-tube strips |
| On-board Memory | ≥1,000 protocols |
| Data Export | USB flash drive support |
| Power Failure Recovery | Auto-resume function with full protocol state retention |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-EA-B-96GA |
| Temperature Range | 4–99 °C |
| Communication Interfaces | USB, RJ45 |
| Input Power | 100–240 V AC, 50–60 Hz (1000 W) |
| Module Dimensions | 156.5 × 253 × 125.8 mm |
| Host Dimensions | 256.5 × 414.5 × 65 mm |
| Compliance | CE-marked for laboratory use in EU |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-48A |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48-well |
| Maximum Heating Rate | 5°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.3°C |
| Excitation Source | High-Intensity LED |
| Detection Method | Bottom-Optical Fluorescence Detection |
| Thermal Control Architecture | Triple-Zone Independent Peltier Control with Dual-Side Ferrotec Modules |
| Thermal Lid | Motorized Auto-Lift Lid with SOAK Function |
| Compatible Consumables | 0.2 mL Single Tubes (Flat/Capless & Dome/Capped), 0.2 mL 8-Tube Strips (Flat/Capless & Dome/Capped) |
| Interfaces | RS232, USB 2.0, Bluetooth 4.0 |
| Operating System Support | Windows 7/8.1/10 (64-bit) |
| Dimensions (L×W×H) | 410 × 386 × 352 mm |
| Net Weight | 28 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | ≥3.0 °C/s |
| Temperature Accuracy | ≤±0.3 °C |
| Well-to-Well Temperature Uniformity | ≤±0.4 °C at 95 °C |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Magnetic Bead-Based Extraction System |
| Automation Level | Dedicated Fully Automatic Platform |
| Sample Throughput per Run | 1–32 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | 15–45 minutes |
| Compatible Consumables | 2.2 mL 96-well Deep-Well Plates |
| Interface | RS232 |
| Operating System | Microsoft Windows 7 / 8.1 / 10 |
| Dimensions (L×W×H) | 440 × 380 × 450 mm |
| Net Weight | 20 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, 450 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96C |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well |
| Heating Rate | 6.5°C/s |
| Temperature Accuracy | ±0.1°C |
| Well-to-Well Temperature Uniformity | ±0.2°C |
| Detection Channels | 6 |
| Excitation Source | Arrayed Planar LED Light Source |
| Optical Detection | Top-reading, calibration-free, bundled high-end imported optical fiber bundle |
| Thermal Control Architecture | 6-zone independent Peltier-based temperature control |
| Input Power | AC 100–240 V, 50/60 Hz, 1000 W |
| Dimensions (L×W×H) | 490 × 290 × 391 mm |
| Net Weight | 28 kg |
| Compatible Consumables | 0.2 mL 96-well plates, 0.2 mL single tubes, 0.2 mL 8-tube strips (transparent, white, frosted) |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPAs-9600 |
| Instrument Type | Magnetic Bead-Based Automation |
| Throughput | 96 samples per run |
| Sample Volume Range | 20–1000 µL |
| Processing Time (96 samples) | ≤30 min |
| Power Supply | AC 220 V, 50 Hz, 1500 VA |
| Dimensions (L×W×H) | 1400 × 700 × 1980 mm |
| Sample Compatibility | Whole blood, swabs, urine, animal/plant tissues |
| Input Vessel Types | Cryovials, microcentrifuge tubes, collection tubes |
| Integrated Functions | Sample aliquoting, magnetic bead-based nucleic acid purification, and PCR master mix dispensing |
| Contamination Control | UV sterilization, HEPA-filtered laminar airflow, droplet capture technology |
| Human-Machine Interface | Full-color capacitive touchscreen with intuitive GUI |
| Brand | BIOER |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | FQD-16B |
| Sample Throughput | 16 wells |
| Maximum Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.1 °C |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-32E |
| Principle | Magnetic bead-based separation |
| Automation Level | Dedicated fully automated platform |
| Sample Throughput | 1–32 samples per run |
| Processing Time | As fast as 8 minutes per batch |
| Heating Capacity | Deep-well heating block with programmable lysis/elution temperature control (ambient to 95 °C) |
| Magnet Type | Permanent magnet rod array with dynamically adjustable oscillation amplitude |
| Sample Plate Compatibility | 2.2 mL 96-well deep-well plates |
| Interface | USB port for protocol transfer and system update |
| Oscillation Mode | Vertical reciprocating motion |
| Dimensions (L×W×H) | 430 × 395 × 435 mm |
| Net Weight | 28.5 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 350 W |
| Safety Features | Interlocked door sensor, built-in UV-C germicidal lamp (254 nm), aerosol-resistant sealing design |
| Modular Expandability | Optional 48-well adapter module available |
| Brand | Bioer |
|---|---|
| Model | HB-202 |
| Temperature Range | (Ambient + 5°C) to 105°C |
| Temperature Accuracy | ≤ ±0.5°C |
| Heating Time | ≤ 12 min (20°C to 100°C) |
| Dimensions (L×W×H) | 300 × 200 × 160 mm |
| Net Weight | 2.8–3.2 kg |
| Power Supply | 220 V~, 50 Hz, 120 W |
| Control System | 32-bit microprocessor |
| Drive Mechanism | Brushless DC motor |
| Heating Element | PTC heater |
| Optional Modules | A (40 × 1.5 mL), B (54 × 0.5 mL), C (96 × 0.2 mL), D (24 × φ15 mm), G (26 × 0.5 mL + 24 × 1.5 mL), H (40 × 2.0 mL), J (96-well microplate), E (115 × 73 × 38 mm water bath insert) |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-96 |
| Instrument Type | Magnetic Bead-Based Automation |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–96 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | 8–15 minutes |
| Compatible Plate Format | 96-well deep-well plates (2.2 mL) |
| Interface | USB, LAN |
| Operating System Support | Windows 7 / 8.1 / 10 |
| Dimensions (L×W×H) | 907 × 495 × 571 mm |
| Net Weight | 81.5 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 1000 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GeneExplorer |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well plate |
| Maximum Heating Rate | 6°C/sec |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.2°C |
| Gradient Function | 12-column linear gradient (1–30°C) |
| Dimensions (L×W×H) | 420 × 269 × 254 mm |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)B |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Uniformity | ≤±0.2 °C |
| Gradient Range | 1–30 °C |
| Temperature Range | 4–105 °C |
| Max Cycles | 99 with nested 2-level programming |
| Ramp Rate Adjustment | Yes |
| Touchdown PCR Support | 0.1–9.9 °C increment/decrement |
| Long PCR Support | Time increment/decrement up to 9 min 59 sec |
| Display | 6.5-inch color LCD touchscreen |
| Connectivity | USB port + Ethernet (LAN) |
| Dimensions (L×W×H) | 345 × 250 × 270 mm |
| Weight | 10 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TC-96/G/H(b)B1 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | ≥5.5 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.2 °C |
| Gradient Range | Up to 30 °C across block |
| Thermal Lid Temperature & Pressure | Adjustable |
| Control Interface | USB-based multi-unit networking (up to 30 units per PC) |
| Data Storage | Internal memory + USB flash drive support |
| Safety Features | Power-loss recovery, file encryption, Ferrotec Peltier modules |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | MB-202 |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Heating Time | ≤ 12 min (varies by block) |
| Oscillation Frequency | 300–3000 rpm |
| Oscillation Amplitude | 3 mm |
| Timer Range | 1 s – 99 h 59 min |
| Power Input | AC 100–240 V, 50/60 Hz, 180 W |
| Dimensions (L×W×H) | 310 × 210 × 145 mm |
| Net Weight | 5.9 kg |
| Block Recognition | Auto-detect (9 standard blocks included) |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TC-EA |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 48-well (dual-format), 4-slide in situ hybridization module |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.2 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Range | 4–105 °C |
| Dimensions (L×W×H) | 368 × 250 × 285 mm |
| Net Weight | 10.5 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (TC-XP-E), 48×2 dual-block (TC-XP-D), 384-well (TC-XP-F), or 4-slide in situ hybridization platform (TC-XP-H) |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ±0.3 °C |
| Well-to-Well Uniformity | ±0.4 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Control Range | 4–99.9 °C |
| Dimensions (L×W×H) | 470 × 340 × 260 mm |
| Net Weight | 10 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)C |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well |
| Max Heating Rate | ≥4 °C/sec |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Uniformity | ≤±0.3 °C |
| Temperature Range | 4–105 °C |
| Gradient Range | 1–30 °C |
| Max Cycles | 99 with nested 2-level programming |
| Ramp Rate Adjustment | 0.1–9.9 °C per step (Touchdown PCR) |
| Time Increment/Decrement | 0–9 min 59 sec (Long PCR support) |
| Control Modes | Block mode and simulated tube mode |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Dimensions (L×W×H) | 345 × 250 × 270 mm |
| Net Weight | 8 kg |
| Interface | USB port |
| Data Protection | Power-fail resume function |
| Brand | BIOER |
|---|---|
| Model | MB-102 |
| Temperature Range | 0°C to 100°C (with cooling down to 14°C below ambient, min. setpoint 0°C) |
| Temperature Accuracy | ≤ ±0.5°C |
| Heating Time | ≤12 min (20°C → 100°C) |
| Oscillation Speed | 300–1500 rpm |
| Oscillation Amplitude | 3 mm |
| Timer Range | 1 s – 99 h 59 min |
| Dimensions (L×W×H) | 328 × 166 × 249 mm |
| Net Weight | 8.5 kg |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz, 150 W |
| Standard Blocks | A (40 × 1.5 mL), B (54 × 0.5 mL), C (96 × 0.2 mL), D (24 × φ15 mm), H (40 × 2.0 mL), G (26 × 0.5 mL + 24 × 1.5 mL), J (96-well microplate) |
| Display | Full-color VFD screen |
| Control System | 32-bit microcontroller with PID temperature regulation |
| Cooling Method | Thermoelectric (Peltier) |
| Motor Type | Brushless DC motor |
| Calibration Function | Built-in temperature calibration |
| Momentary Oscillation Mode | Yes |
| Brand | Bioer |
|---|---|
| Model Series | HB-T1, HB-T2, CHB-T1, CHB-T2 |
| Temperature Range | 0°C to 100°C (model-dependent) |
| Temperature Accuracy | ≤ ±0.2°C |
| Heating Time | ≤ 8 min (20°C → 100°C) |
| Dimensions | 150 × 170 × 145 mm (L × W × H) |
| Net Weight | ≤ 2.0 kg |
| Power Input | HB/CHB-T1 & T2: AC 100–240 V, 50/60 Hz |
| Timer Range | 0–99 h 59 min |
| Max Program Steps | 9 |
| Max Cycles per Program | 99 |
| Standard Block Modules | A (20 × 0.5 mL), B (35 × 1.5 mL), C (54 × 0.5 mL), D (96 × 0.2 mL), E (35 × 2.0 mL) |
| Brand | Bioer |
|---|---|
| Model | N3-8 |
| Type | Non-Circulating Heating Water Bath |
| Capacity | 8 L |
| Temperature Range | Ambient ±5°C to 99.9°C |
| Temperature Stability | ±0.2°C at 37°C |
| Display | LED Digital |
| Power Supply | AC 220–240 V, 50/60 Hz, 600 W |
| Internal Chamber Dimensions | 325 × 265 × 150 mm (L×W×H) |
| External Dimensions | 445 × 285 × 316 mm (L×W×H) |
| Safety Features | Low-Water-Level Protection, Over-Temperature Cut-Off, Compressor Overload Protection (for models with optional cooling), Current Overload Protection |
| Brand | Bioer |
|---|---|
| Model | CHB-202 |
| Temperature Range | −10 °C to 105 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Heating Time to 100 °C | ≤ 35 min |
| Dimensions (L×W×H) | 300 × 200 × 160 mm |
| Net Weight | 3.2 kg |
| Power Supply | AC 220 V, 50 Hz, 120 W |
| Display | Full-color VFD |
| Programmable Setpoints | 5 independent temperature points with multi-segment continuous cycling capability |
| Standard Block Compatibility | A (40 × 1.5 mL), B (54 × 0.5 mL), C (96 × 0.2 mL), D (24 × φ15 mm), H (40 × 2.0 mL), G (26 × 0.5 mL + 24 × 1.5 mL), J (96-well microplate), E (water bath insert: 115 × 73 × 38 mm) |
| Timer Range | 1 min – 99 h 59 min |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | B-48DA |
| Instrument Type | Dual-Block Gradient PCR Thermal Cycler |
| Sample Capacity | 2 × 48-well (0.2 mL tubes or 8-tube strips) |
| Heating Rate | >4 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Block Uniformity | ≤ ±0.2 °C across wells |
| Temperature Range | 4–105 °C |
| Gradient Range | 1–30 °C |
| Max Cycles | 99 with 2-level nesting |
| Time Increment/Decrement | 0–9 min 59 sec |
| Temp Increment/Decrement | 0.1–9.9 °C |
| Control Modes | Block mode and simulated tube mode |
| Interface | RS232, USB, LAN, Bluetooth |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Dimensions | 457 × 316 × 309 mm (L×W×H) |
| Safety & Compliance | Supports power-fail recovery, intelligent hot lid control, TAS thermal uniformity technology |
Show next