- All
- Favorite
- Popular
- Most rated
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Max. Heating Rate | 5°C/s |
| Temperature Accuracy | ≤ ±0.15°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.2°C |
| Display | 10.4″ TFT-LCD capacitive touch screen |
| Cooling Technology | Custom Ferrotec thermoelectric modules |
| Optional Block Surface | Gold-plated (Au) thermal block with TAS (Thermal Alignment System) |
| Connectivity | USB 2.0, RJ45 LAN, Bluetooth 4.0 (with PC wireless control adapter) |
| Temperature Range | 4–105°C |
| Gradient Function | 6 independent zones, adjustable gradient span 0.1–5.0°C per zone |
| Max. Cycle Number | 99 cycles with nested 2-level programming (suitable for nested PCR) |
| Time Increment/Decrement | 0–9 min 59 sec (enables Long PCR protocols) |
| Temp Increment/Decrement | 0–9.9°C (supports Touchdown PCR) |
| Power Input | AC 100–240 V, 50/60 Hz, 800 W |
| Dimensions (L×W×H) | 457 × 316 × 309 mm |
| Net Weight | 14 kg |
| Compatible Consumables | 0.2 mL 96-well PCR plates (full-skirt, half-skirt, unskirted), 0.2 mL single tubes, 0.2 mL 8-tube strips |
| On-board Memory | ≥1,000 protocols |
| Data Export | USB flash drive support |
| Power Failure Recovery | Auto-resume function with full protocol state retention |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-48A |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48-well |
| Maximum Heating Rate | 5°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.3°C |
| Excitation Source | High-Intensity LED |
| Detection Method | Bottom-Optical Fluorescence Detection |
| Thermal Control Architecture | Triple-Zone Independent Peltier Control with Dual-Side Ferrotec Modules |
| Thermal Lid | Motorized Auto-Lift Lid with SOAK Function |
| Compatible Consumables | 0.2 mL Single Tubes (Flat/Capless & Dome/Capped), 0.2 mL 8-Tube Strips (Flat/Capless & Dome/Capped) |
| Interfaces | RS232, USB 2.0, Bluetooth 4.0 |
| Operating System Support | Windows 7/8.1/10 (64-bit) |
| Dimensions (L×W×H) | 410 × 386 × 352 mm |
| Net Weight | 28 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | ≥3.0 °C/s |
| Temperature Accuracy | ≤±0.3 °C |
| Well-to-Well Temperature Uniformity | ≤±0.4 °C at 95 °C |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96C |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well |
| Heating Rate | 6.5°C/s |
| Temperature Accuracy | ±0.1°C |
| Well-to-Well Temperature Uniformity | ±0.2°C |
| Detection Channels | 6 |
| Excitation Source | Arrayed Planar LED Light Source |
| Optical Detection | Top-reading, calibration-free, bundled high-end imported optical fiber bundle |
| Thermal Control Architecture | 6-zone independent Peltier-based temperature control |
| Input Power | AC 100–240 V, 50/60 Hz, 1000 W |
| Dimensions (L×W×H) | 490 × 290 × 391 mm |
| Net Weight | 28 kg |
| Compatible Consumables | 0.2 mL 96-well plates, 0.2 mL single tubes, 0.2 mL 8-tube strips (transparent, white, frosted) |
| Brand | BIOER |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | FQD-16B |
| Sample Throughput | 16 wells |
| Maximum Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.1 °C |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GeneExplorer |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well plate |
| Maximum Heating Rate | 6°C/sec |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.2°C |
| Gradient Function | 12-column linear gradient (1–30°C) |
| Dimensions (L×W×H) | 420 × 269 × 254 mm |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)B |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Uniformity | ≤±0.2 °C |
| Gradient Range | 1–30 °C |
| Temperature Range | 4–105 °C |
| Max Cycles | 99 with nested 2-level programming |
| Ramp Rate Adjustment | Yes |
| Touchdown PCR Support | 0.1–9.9 °C increment/decrement |
| Long PCR Support | Time increment/decrement up to 9 min 59 sec |
| Display | 6.5-inch color LCD touchscreen |
| Connectivity | USB port + Ethernet (LAN) |
| Dimensions (L×W×H) | 345 × 250 × 270 mm |
| Weight | 10 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TC-96/G/H(b)B1 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | ≥5.5 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.2 °C |
| Gradient Range | Up to 30 °C across block |
| Thermal Lid Temperature & Pressure | Adjustable |
| Control Interface | USB-based multi-unit networking (up to 30 units per PC) |
| Data Storage | Internal memory + USB flash drive support |
| Safety Features | Power-loss recovery, file encryption, Ferrotec Peltier modules |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TC-EA |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 48-well (dual-format), 4-slide in situ hybridization module |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.2 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Range | 4–105 °C |
| Dimensions (L×W×H) | 368 × 250 × 285 mm |
| Net Weight | 10.5 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (TC-XP-E), 48×2 dual-block (TC-XP-D), 384-well (TC-XP-F), or 4-slide in situ hybridization platform (TC-XP-H) |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ±0.3 °C |
| Well-to-Well Uniformity | ±0.4 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Control Range | 4–99.9 °C |
| Dimensions (L×W×H) | 470 × 340 × 260 mm |
| Net Weight | 10 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)C |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well |
| Max Heating Rate | ≥4 °C/sec |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Uniformity | ≤±0.3 °C |
| Temperature Range | 4–105 °C |
| Gradient Range | 1–30 °C |
| Max Cycles | 99 with nested 2-level programming |
| Ramp Rate Adjustment | 0.1–9.9 °C per step (Touchdown PCR) |
| Time Increment/Decrement | 0–9 min 59 sec (Long PCR support) |
| Control Modes | Block mode and simulated tube mode |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Dimensions (L×W×H) | 345 × 250 × 270 mm |
| Net Weight | 8 kg |
| Interface | USB port |
| Data Protection | Power-fail resume function |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | B-48DA |
| Instrument Type | Dual-Block Gradient PCR Thermal Cycler |
| Sample Capacity | 2 × 48-well (0.2 mL tubes or 8-tube strips) |
| Heating Rate | >4 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Block Uniformity | ≤ ±0.2 °C across wells |
| Temperature Range | 4–105 °C |
| Gradient Range | 1–30 °C |
| Max Cycles | 99 with 2-level nesting |
| Time Increment/Decrement | 0–9 min 59 sec |
| Temp Increment/Decrement | 0.1–9.9 °C |
| Control Modes | Block mode and simulated tube mode |
| Interface | RS232, USB, LAN, Bluetooth |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Dimensions | 457 × 316 × 309 mm (L×W×H) |
| Safety & Compliance | Supports power-fail recovery, intelligent hot lid control, TAS thermal uniformity technology |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | FQD-A1600 |
| Instrument Type | Real-Time Quantitative PCR System with Integrated Sample-to-Answer Automation |
| Sample Throughput | 16 samples per run |
| Maximum Heating Rate | ≥10 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Inter-well Temperature Uniformity | ≤±0.3 °C |
| Dimensions (L×W×H) | 1850 × 730 × 1530 mm |
| Power Supply | AC 220 V, 50 Hz, 2800 VA |
| Sample Input Format | Compatible with standard cryovials, centrifuge tubes, and clinical collection tubes (e.g., 1.5–2.0 mL) |
| Sample Types | Whole blood, nasopharyngeal/oropharyngeal swabs, urine, animal/plant tissues for DNA/RNA extraction |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-16A (Mini) |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 16-well (single tubes or 8-tube strips) |
| Max Heating Rate | 5.0 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Detection Channels | 4 |
| Detection Sensitivity | 1 copy |
| Compatible Consumables | 0.2 mL transparent/white/frosted PCR tubes and 8-tube strips |
| Optical Design | Top-scanning fluorescence detection with optimized light path to minimize stray light |
| Thermal Module | Custom Peltier-based system |
| Power Input | DC 24 V, 180 W |
| Dimensions (L×W×H) | 280 × 240 × 220 mm |
| Net Weight | 6.5 kg |
| Interface | RS232 |
| Operating System | Windows 7 / 8.1 / 10 |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96A |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well |
| Max Heating Rate | 5.0°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.3°C |
| Excitation Source | Long-Life LED |
| Detection Mode | Bottom-Reading Optical System (Patented) |
| Thermal Control | Multi-Point PID with Peltier-based Semiconductor Modules (Ferrotec Custom) |
| Power Input | AC 100–240 V, 50/60 Hz, 650 W |
| Dimensions (L×W×H) | 410 × 386 × 352 mm |
| Net Weight | 28 kg |
| Interfaces | RS232, USB, Bluetooth |
| OS Compatibility | Windows 7 / 8.1 / 10 |
Show next