| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom V1 |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GAP TW |
| Price | Upon Request |
| Detection Gases | O₂ (0–30.0 %vol), Combustible Gas (CH₄, 0–100 %LEL) |
| Detection Principles | Electrochemical (O₂), Catalytic Bead (Combustible) |
| Sampling Method | Natural Diffusion |
| Measurement Accuracy | ±3% FS (O₂), ±5% FS (Combustible) |
| Display Resolution | 0.1 %vol (O₂), 1 %LEL (Combustible) |
| Alarm Thresholds (Configurable) | O₂ Low: 19.5 %vol, O₂ High: 23.5 %vol |
| Combustible | 25 %LEL |
| Response Time | ≤60 s (both gases) |
| Alarms | Visual (LED), Audible (≥75 dB @ 30 cm), Vibration, Voice Prompt |
| Power | ICR18500 Li-ion Battery, 3.7 V / 2000 mAh |
| Operating Time | ≥10 h (continuous) |
| Operating Temperature | −10 to +55 °C |
| Operating Humidity | 0–95 %RH (non-condensing) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | PR-GDS-100 |
| Pricing | Upon Request |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | A.21/O2 |
| Pressure Measurement Range | 690–2070 kPa (0–500 psi) |
| Response Time | ≤5 ms |
| Pressure Sensor Accuracy | ±0.2 ms timing resolution |
| Ignition Wire | NiCr, 25 cm length, Ø0.6 mm, 3.85 Ω/m |
| Burst Disc | Aluminum, 0.2 mm thickness, nominal burst pressure ≈ 320 psi |
| Ignition Power Supply | 10 A / 16 V constant current |
| Data Acquisition | Digital storage oscilloscope with PC interface and printer output |
| Remote Ignition Distance | ≥2 m (separate control box) |
| Compliance | UN Manual of Tests and Criteria, Rev. 7, Test 2(c)(i).2 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Beckmann-Junk Method |
| Price Range | USD 27,000 – 68,000 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HST100 |
| Price Range | USD 27,000 – 68,000 |
| Heating Method | Electrically Heated Aluminum Block |
| Sample Capacity | 21 Positions |
| Sample Tube Dimensions | Ø30 ±0.3 mm × 230 ±2 mm (Cylindrical, Round-Bottom, Glass Stopper) |
| Temperature Range | Ambient to 110 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Sensor | PT100 Probe |
| Over-Temperature Safety Cut-off | 120 °C |
| Controller | Dedicated PID Temperature Program Controller |
| Power Supply | 230 V / 50 Hz, 2400 VA |
| Illumination System | Specialized Fluorescent Lamp (Non-Glare, Optimized for NO₂ Vapor Detection) |
| Viewing Assembly | Rigid Adjustable Lamp Mount with UV-Enhanced Visible Spectrum Output |
| Display | Dual Digital Readout (Setpoint & Actual Temperature) |
| Sample Holder Depth | 170 mm |
| Sample Holder Diameter | 31 mm |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | Methyl Violet Method |
| Temperature Range | 60–140 °C |
| Control Accuracy | ±0.1 °C |
| Sample Capacity | 24 positions (20.5 mm diameter × 280 mm depth) |
| Heating Block | Anodized aluminum with PID controller |
| Temperature Sensor | PT100 probe |
| Safety Features | Over-temperature cut-off, ISO-insulated housing |
| Power Supply | 230 V / 50 Hz, 1500 VA |
| Compliance | MIL-STD-286C (Sections 120 & 134.5), ISO 8765:2017 (Nitrocellulose stability testing) |
| Accessories | 24× cylindrical tubes (OD 20 mm, ID 17 mm, L 290 mm), vented cork stoppers, stainless steel hooks, methyl violet indicator paper (200 sheets/pack) |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AB140 |
| Price Range | USD 27,000 – 68,000 |
| Heating Block Material | Aluminum |
| Sample Capacity | 5 positions |
| Sample Tube Dimensions | Ø17.5 ± 0.1 mm × 70 mm depth (tube body) |
| Temperature Sensor | PT100 probe |
| Temperature Control | PID controller with independent control cabinet |
| Max Setpoint | 140 °C |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | 230 V / 50 Hz, 300 VA |
| Safety Features | Over-temperature cut-off protection |
| Accessories Included | 5 calibrated cylindrical sample tubes (with three annular bands), perforated rubber stoppers, platinum-tipped glass rods, KI-starch test paper support fixture |
| Brand | RAE Systems |
|---|---|
| Origin | USA |
| Model | FGM-1200S |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Sensor Type | Smart Digital NDIR |
| Installation | Fixed Wall/Mast Mount |
| Enclosure Material | Stainless Steel |
| Protection Rating | IP65 |
| Explosion Protection | ATEX II 2G EEx d II CT6, UL/CSA Certified |
| Operating Temperature | CH₄: −40 °C to +70 °C |
| CO₂ | −20 °C to +60 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Pressure Range | 90–110 kPa |
| Power Supply | DC 9–36 V, 60 mA (170 mA @ 24 VDC) |
| Output Signals | 4–20 mA (adjustable, 600 Ω load), RS485 Modbus RTU, Two Programmable Dry Contact Relays (30 VDC, 2 A) |
| Response Time (T90) | ≤30 s |
| Accuracy | ±2% FS |
| Sampling Method | Diffusion |
| Display | Backlit LCD with Four-Color Status LEDs |
| Dimensions (H×W×D) | 168 × 150 × 109 mm |
| Weight | 3.5 kg |
| Brand | RAE Systems |
|---|---|
| Origin | USA |
| Model | PGM-1600 |
| Dimensions | 21 × 8.5 × 6.5 cm |
| Weight | 700 g (with Li-ion battery) |
| Sampling Method | Pump-assisted |
| Enclosure Material | Engineering plastic with rubber overmold |
| Ingress Protection | IP65 |
| EMC Compliance | EMC Directive 89/336/EEC |
| Operating Temperature | −20 °C to +50 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Hazardous Area Certification | Ex ia(d) IIC T4 |
| Display | Graphic LCD with auto-backlight |
| Languages | Chinese, English + icons |
| Alarm | 95 dB @ 30 cm audible alarm, dual-color LED flash |
| Alarm Types | High/Low gas concentration, low battery, sensor fault, pump blockage |
| Data Storage | SD card (Excel-compatible format) |
| Sampling Interval | 1–3600 s adjustable |
| Pump Flow Rate | 450–550 cc/min |
| Battery | 3.7 V rechargeable Li-ion |
| Runtime | Up to 16 h (typical field use) |
| Charge Time | 8 h |
| Calibration | Zero and span calibration |
| Sensor Options | LEL or LEL/VOL catalytic bead sensor |
| Sensor Specifications | O₂ (0–30% vol, 0.1% res., T90 ≤15 s) |
| LEL/VOL (dual-range | 0–100% LEL / 0–100% vol, 1% res., T90 ≤15 s) |
| Brand | RIKEN KEIKI |
|---|---|
| Origin | Japan |
| Model | SD-2500 |
| Detection Principle | Catalytic Bead (Pellistor) Combustion |
| Explosion Protection Rating | Ex d IIB T4 Gb |
| Operating Temperature Range | 0–250 °C |
| Display | Integrated LED Concentration Indicator |
| Input Power | 24 V DC (loop-powered) |
| Output Signal | 4–20 mA analog output with HART protocol support |
| Certifications | JIS ATEX, IECEx, UL/cUL Class I Div 1, FM Approved |
| Enclosure Rating | IP66/IP67 |
| Sensor Life Expectancy | ≥3 years typical in clean air environments |
| Brand | ROOKO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | FT-401 |
| Pricing | Upon Request |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SH706B |
| Price | Upon Request |
| Temperature Control Range | Ambient to 800 °C |
| Temperature Accuracy | ±1 °C |
| Timing Accuracy | 1 s |
| Sample Volume | 50 µL |
| Repeatability | ≤10 °C |
| Reproducibility | ≤20 °C |
| Compliance | DL/T 706–2017, SH/T 0642–1997, GB/T 21860–2008 |
| Display | Color LCD Touchscreen |
| Data Export | USB flash drive (CSV/Excel) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2.5 Hz |
| Max. Power Consumption | <1500 W |
| Operating Environment | 5–35 °C, RH ≤85% |
| Dimensions (W×D×H) | 450×380×550 mm |
| Net Weight | 35 kg |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HWP15-10S |
| Quotation | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Timing Range | 0–30 min |
| Timing Accuracy | ±0.01 s |
| Time Display Resolution | 1 s |
| Sample Volume | 2 mL |
| Drop Height | 1 m |
| Flame Detection Response Time | ≤6 ms |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1064Defender™ Handheld Raman Analyzer |
| Pricing | Available Upon Request |
| Brand | THT |
|---|---|
| Origin | United Kingdom |
| Model | ES-ARC |
| Compliance | ASTM E698, ISO 22517, UN Test Series 3 (H.2, H.3), IEC 60079-10-1 |
| Temperature Range | Ambient to 500 °C |
| Pressure Rating | Up to 200 bar |
| Sample Mass Capacity | 0.1–10 g |
| Heat Flow Resolution | <0.1 mW |
| Adiabatic Tracking Accuracy | ±0.02 °C/min |
| Data Acquisition Rate | 1 Hz |
| Brand | Yanei |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DG07-D |
| Pricing | Upon Request |
| Operating Environment | −5°C to 45°C, <95% RH |
| Cylindrical Chamber Rotation Angle | 0–90° |
| Chamber Volume | 200 dm³ (Ø600 mm × L720 mm) |
| Nozzle-to-Chamber Distance | Adjustable 20–35 mm |
| Ignition Source | Adjustable-height candle flame |
| Compatible Can Height | 100–400 mm |
| Compatible Can Diameter | 20–80 mm |
| Detection Methods | Near-infrared (NIR) + Pressure Sensing |
| Pressure Range | 0–400 kPa, Accuracy: ±0.5% F.S. |
| Spectral Response | UV 185–260 nm, NIR 760–1100 nm |
| Spectral Sampling Rate | 5000 Hz |
| Timing Resolution | ±0.01 s |
| Instrument Dimensions (L×W×H) | 1200 × 660 × 780 mm |
| Brand | Yanei |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DG09-D |
| Pricing | Available Upon Request |
| Operating Environment | −5°C to 45°C, <95% RH |
| Atmospheric Pressure Range | 0–110 kPa (±0.25% FS) |
| Temperature Control Range | Ambient +5°C to 100°C (±0.5°C accuracy) |
| Standard Test Temperatures | 60.5°C and 75°C |
| Sample Volume | 1–5 mL (≤0.03 mL dispensing accuracy) |
| Timing Range | 0–999 s (±0.01 s accuracy) |
| Flame Detection Method | Near-Infrared (NIR) Array Spectroscopy |
| Ignition Method | Electronic Spark Ignition |
| Ignition Source Positioning | Motorized Rotational Alignment |
| Dimensions (L×W×H) | 570 mm × 350 mm × 350 mm |
| Sample Holder Options | Stainless Steel or Anodized Aluminum Crucibles |
| Integrated Control System | Embedded Industrial PC with 10.1″ Capacitive Touchscreen |
| Connectivity | Wi-Fi-enabled for multi-unit remote operation and centralized data management |
| Brand | Yanei |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DG10-D Plus |
| Pricing | Available Upon Request |
| Brand | Yanei |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | DG13-D |
| Pricing | Upon Request |
| Operating Environment | −5°C to 45°C, <95% RH |
| Gas Volume Measurement Accuracy | ±1.5 mL, Resolution: 0.01 mL |
| Gas Evolution Rate Range | 0–36 L/min |
| Gas Collection Capacity | 0–1.5 L |
| Water Injection Volume | 0–100 mL, Accuracy: ≤±1 mL |
| Pressure Measurement Range | 0–120 kPa, Accuracy: ±0.05% F.S. |
| Mass Measurement Range | 0–3100 g, Accuracy: ±0.01 g |
| Timing Range | 0–200 h, Accuracy: ±0.01 s |
| Reaction Vessel Temperature Control | 20 ± 0.5 °C |
| Dimensions (L×W×H) | Main Unit: 620 × 520 × 485 mm |
| Gas Collection Module | 320 × 210 × 480 mm |
| Brand | Yanei |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | DG21-D |
| Pricing | Upon Request |
| Temperature Range | −50 °C to 400 °C |
| Temperature Accuracy | ±0.2 °C (−50 °C to 150 °C), ±0.3 °C (150 °C to 400 °C) |
| Dewar Thermal Loss Rate | ≤10 mW |
| Constant Power Range | 0.1–2 W |
| Constant Power Accuracy | ≤0.01 W |
| Furnace Temperature Control Range | Ambient +5 °C to 220 °C |
| Furnace Temperature Stability | ±0.5 °C |
| Heating Rate Range | 0–2 °C/min |
| Coolant Circulation Flow | 3 L/min |
| Dewar Material | 316L Stainless Steel |
| Dewar Volume | 1000 mL |
| Dimensions (L×W×H) | 720 mm × 520 mm × 520 mm |
| Brand | Yanei |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DG23-D |
| Pricing | Available Upon Request |
| Operating Environment | −5°C to 40°C, <95% RH |
| Test Chamber Dimensions | 30 cm × 30 cm |
| Camera Resolution | 300 K pixels |
| Wireless Camera Transmission Range | 100 m (line-of-sight) |
| Fire Suppression Cover Dimensions | 32 cm × 32 cm × 5 cm |
| Ignition Method | Electric Fuse |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ECB-2002A |
| Price | Upon Request |
| Test Vessel Temp. Range | Ambient to 200 °C |
| Max. Design Pressure | ≥2.0 MPa |
| Explosion Pressure Sensor Range | ≥5.0 MPa, Linearity: ±1.0% FS |
| Pressure Sampling Rate | ≥5 kHz |
| Data Points per Test | ≥10,000 |
| Gas Inlet Channels | 3 |
| Max. Stirring Speed | 400 rpm (adjustable) |
| Operating Environment | −5–45 °C, <95% RH |
| Gas Pressure Control Accuracy | ±0.1% FS |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP01-20S |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±1 °C |
| Uniformity in Test Zone | ±1.0 °C (≤140 °C), ±1.5 °C (140–180 °C), ±2.0 °C (180–200 °C) |
| Thermocouple Range | −40 to 1000 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Measurement Accuracy | ±1.5 °C or ≤±0.004 |
| Response Time | 0.5 s |
| Standard Timer Range | 0–240 h |
| Custom Timer Range | 0–480 h |
| Timer Accuracy | ±0.01 s |
| Timer Display Resolution | 1 s |
| Chamber Volume | ≥27 L |
| Self-Heating Test Mesh Cage Sizes | 25 mm × 25 mm × 25 mm and 100 mm × 100 mm × 100 mm |
| 75 °C Stability Vessel Dimensions | Φ(50.5 ± 0.5) mm × 150 mm |
| Interior Chamber Dimensions | 350 mm × 350 mm × 400 mm |
| Safety Valve Activation Pressure | 60 kPa |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HWP01-20S |
| Pricing | Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP02-20S |
| Quotation | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Ignition Source Temperature | ≥1000 °C |
| Ignition Methods | Gas igniter and silicon nitride rod |
| Combustion Detection Method | Near-infrared (NIR) spectroscopy |
| Combustion Travel Range | 0–250 mm |
| Burning Distance Measurement Accuracy | ±0.5 mm |
| Maximum Combustion Velocity Detection | 250 mm/s |
| Timing Range | 5 min (non-metallic samples) |
| Time Display Resolution | 0.1 s |
| Stacking Mold Dimensions | 260 mm (L) × 20 mm (W), triangular cross-section with internal height of 10 mm |
| Combustion Plate Material | Alumina-mullite ceramic — non-porous, non-combustible, low thermal conductivity |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HWP04-10S |
| Pricing | Upon Request |
| Operating Environment | (-5–45)°C, <95% RH |
| Channel Capacity | Standard 2 channels, customizable up to 8 |
| Temperature Control Range | Ambient to 98°C |
| Temperature Control Accuracy | ≤±0.5°C |
| Temperature Fluctuation | ≤±0.3°C |
| Temperature Uniformity | ±0.5°C |
| Heating Tube Material | SUS316 stainless steel |
| Bath Tank Material | Stainless steel |
| Timing Range | 0–35 days |
| Timing Accuracy | ±0.01 s |
| Time Display Resolution | 1 minute |
| Sample Vessel Volume | 3000 mL (effective volume: 2000 mL) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Model | HWP05-20S |
| Operating Temperature | (-5–45) °C, <95% RH |
| Optical Detection Range | 760–1100 nm (IR), Sampling Frequency: 5000 Hz |
| Mass Measurement Range | 0–3100 g, Resolution: ≤±0.01 g |
| Mass Data Acquisition Rate | ≤5 Hz |
| Heating Element | Inert metal wire (standard geometry), Power: 150 W ±2 W |
| Detection Modes | IR sensor array or analytical balance |
| Balance Accuracy | ±0.1 g |
| Ambient Temp. Range | -10–+60 °C, Accuracy: ±0.5 °C |
| Ambient Humidity Range | 5–95% RH, Accuracy: ±5.0% RH |
| Timer Range | 0–24 h, Resolution: ±0.01 s, Accuracy: ±7 ms/min |
| Test Plate | Alumina ceramic, 150 mm × 150 mm × 6 mm |
| Sample Mold | PTFE, conical (70 mm ID, 60° apex angle) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HWP06-20S |
| Price | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Pressure Vessel Dimensions | Ø60 mm × 89 mm (cylindrical stainless steel, side-mounted pressure sensor) |
| Pressure Sensor Response Time | ≤5 ms (0–3 MPa step change) |
| Pressure Measurement Range | 0–5 MPa |
| Pressure Accuracy | ±0.1% FS |
| Ignition Method | Electronic spark ignition |
| Burst Disc Rated Pressure | 2.5 MPa ±5% |
| Timing Range | 0–60 s |
| Timing Accuracy | ±0.001 ms |
| Timing Resolution | 0.01 ms |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HWP08-10S |
| Pricing | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Standard Test Temperatures | 60.5 °C / 75 °C |
| Temperature Control Range | Customizable |
| Temperature Control Accuracy | ±0.5 °C |
| Ambient Atmospheric Pressure Measurement Range | (0–110) kPa |
| Ambient Atmospheric Pressure Measurement Accuracy | ±0.25 kPa |
| Ignition Timing Options | 30 s / 60 s |
| Sample Volume | (1–3) mL |
| Sample Delivery Accuracy | ±0.05 mL |
| Timing Range | (0–999) s |
| Timing Resolution | 0.1 s |
| Timing Accuracy | ±0.01 s |
| Ignition Method | Spark Plug |
| Sample Vial Capacity | 20 mL |