| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | Domestic (China) |
| Model | HWP09-10S |
| Quotation | Upon Request |
| Operating Environment | (-5–45) °C, <95% RH |
| Detection Method | Near-Infrared (NIR) |
| Spectral Response Range | 760–1100 nm |
| Spectral Response Frequency | 5000 Hz |
| Ambient Temperature Range | (-10–+60) °C |
| Ambient Temperature Accuracy | ±0.5 °C |
| Ambient Humidity Range | (5–95)% RH |
| Ambient Humidity Accuracy | ±5.0% RH |
| Combustion Detection Response Time | ≤6 ms |
| Ignition Distance Measurement Range | 15–90 cm |
| Burner Positioning Accuracy | ±1 mm |
| Timing Resolution | ±0.01 s |
| Minimum Actuation Duration | 5 s |
| Ignition Source | Gas-fired igniter |
| Aerosol Can Orientation | Motorized vertical/inverted repositioning |
| Compatible Can Dimensions | Height 120–400 mm, Diameter 30–80 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP10-10S |
| Pricing | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Ambient Temperature Range | -10 to +60 °C |
| Ambient Temperature Accuracy | ±0.5 °C |
| Ambient Humidity Range | 5–95% RH |
| Ambient Humidity Accuracy | ±5.0% RH |
| Flame Detection Response Time | ≤6 ms |
| Differential Pressure Range | -5 to +5 kPa |
| Pressure Measurement Accuracy | ±0.1% FS |
| Spectral Response Range | 760–1100 nm (Near-Infrared) |
| Spectral Response Frequency | 5000 Hz |
| Timing Accuracy | ±0.01 s |
| Timing Resolution | 0.1 s |
| Ignition Source | Standardized candle flame |
| Test Chamber Dimensions | Ø600 mm × 720 mm (200 dm³ volume) |
| Aerosol Can Orientation | Motorized dual-axis positioning (vertical/inverted) |
| Compatible Can Dimensions | Height 120–400 mm, Diameter 30–80 mm |
| Nozzle-to-Chamber Distance | Adjustable from 25 to 100 mm |
| Residual Liquid Collection Tray | Removable stainless-steel drip pan |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP11-10S |
| Price | Upon Request |
| Operating Temperature | (-5 to 45) °C |
| Relative Humidity Range | 5–95 %RH |
| Flame Height Detection Range | 0–235 mm |
| Flame Height Resolution | 5 mm |
| Flame Detection Response Time | ≤6 ms |
| Ambient Temperature Measurement Range | (-10 to +60) °C |
| Ambient Temperature Accuracy | ±0.5 °C |
| Ambient Humidity Accuracy | ±5.0 %RH |
| Ignition Method | Gas-powered igniter |
| Timing Accuracy | ±0.01 s |
| Sample Support Plate Diameter | Ø150 mm |
| Support Plate Material | High-Temperature Quartz |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP12-10S |
| Pricing | Available Upon Request |
| Operating Temperature | (-5 to 45) °C |
| Relative Humidity | <95% RH |
| Compressed Air Flow Range | 5–500 sccm |
| Flow Control Accuracy | ±1% FS |
| Flow Response Time | ≤1 s |
| Ignition Method | Electric Spark |
| Combustion Detection | Infrared Photodetection |
| Combustion Detection Response Time | ≤1 ms |
| Flame Propagation Velocity Range | ≤500 cm/s |
| Flame Propagation Velocity Accuracy | ±5 mm/s |
| Safety Valve Activation Pressure | 2 kg/cm² |
| Reaction Tube Dimensions | 300 mm (L) × 50 mm (ID) × 5 mm (wall thickness) |
| Maximum Inlet Gas Pressure | ≤5 MPa |
| Sample Bag Capacity | 1 L |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HWP13-10S |
| Temperature Control Range | Ambient to 200°C |
| Temperature Accuracy | ±1°C |
| Uniformity | ±1.0°C (≤140°C), ±1.5°C (140–180°C), ±2.0°C (180–200°C) |
| Thermocouple Range | −40 to 1000°C |
| Temp. Resolution | 0.1°C |
| Temp. Measurement Accuracy | ±1.5°C or ≤±0.004 |
| Response Time | 0.5 s |
| Standard Timing Range | 0–240 h |
| Custom Timing Range | 0–480 h |
| Timing Accuracy | ±0.01 s |
| Timing Resolution | 1 s |
| Chamber Volume | ≥27 L |
| Sample Cage Dimensions | 25 mm and 100 mm cubes |
| Test Tube Dimensions (Φ×H) | (50.5±0.5) mm × 150 mm |
| Interior Chamber Dimensions | 350 mm × 350 mm × 400 mm |
| Safety Valve Activation Pressure | 60 kPa |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP14-10S |
| Quotation | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Temperature Measurement Range | (-40 to 1000) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1.5 °C or ≤ ±0.004 |
| Temperature Sampling Rate | 1000 Hz |
| Deflagration Distance | 50 mm |
| Deflagration Velocity Range | ≤1500 mm/s |
| Velocity Measurement Accuracy | ±0.1 mm/s |
| Time Display Resolution | ±0.1 ms |
| Detection Method | Thermocouple-based temperature monitoring |
| Dewar Vessel Internal Volume | 300 cm³ |
| Dewar Inner Diameter | 48 mm |
| Dewar Outer Diameter | 60 mm |
| Dewar Length | 200 mm |
| Dewar Cooling Half-life | ≥5 h |
| Ignition Flame Length | ≥20 mm |
| Instrument Dimensions (L×W×H) | 830 mm × 400 mm × 600 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HWP16-10S |
| Pricing | Available Upon Request |
| Operating Temperature Range | −5 °C to 45 °C |
| Relative Humidity Limit | <95% RH |
| Flame Detection Method | Infrared Sensor |
| Char Detection Method | Colorimetric Standard-Based Optical Analysis |
| Timing Range | 0–999 s |
| Timing Accuracy | ±0.01 s |
| Time Display Resolution | 1 s |
| Reaction Vessel | Ceramic, Ø100 mm |
| Ambient Temperature Measurement Range | −10 °C to +60 °C |
| Ambient Temperature Accuracy | ±0.5 °C |
| Ambient Humidity Measurement Range | 5–95% RH |
| Ambient Humidity Accuracy | ±5.0% RH |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP17-10S |
| Operating Temperature | (-5–45) °C |
| Relative Humidity | <95% RH |
| Motor Speed | 140 ± 3 rpm (at maximum load) |
| Load Range | 1–2–5–10–20–40–60–80–120–160–240–360 N |
| Load Accuracy | ±0.038 N (1 N), ±0.048 N (2 N), ±0.08 N (5 N), ±0.21 N (10 N), ±0.45 N (20 N), ±0.49 N (40 N), ±0.22 N (60 N), ±0.27 N (80 N), ±0.32 N (120 N), ±0.37 N (160 N), ±0.43 N (240 N), ±0.48 N (360 N) |
| Sieve Mesh | 35 mesh (optional) |
| Alumina Ceramic Surface Roughness | 9–32 µm |
| Center-to-Center Distance (Weight–Ceramic Rod) | 11, 16, 21, 26, 31, 36 cm |
| Ceramic Plate Stroke | 10 mm |
| Ceramic Plate Dimensions (L×W×H) | 25 × 25 × 5 mm |
| Ceramic Rod Dimensions (Φ×L) | 10 × 15 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HWP18-30S |
| Quotation | Upon Request |
| Operating Environment | (-5–45) °C, <95% RH |
| Impact Masses | 0.5 kg ±0.1%, 1 kg ±0.1%, 2 kg ±0.1%, 5 kg ±0.1%, 10 kg ±0.1% |
| Drop Height Range | 0–1000 mm |
| Positioning Accuracy | ±1 mm |
| Guide Rail Verticality | ≤0.1 mm/m |
| Hammer Coaxiality | ≤φ0.15 mm |
| Instrument Planarity Deviation | ≤0.012 mm |
| Impact Energy Range | 0.5–100 J |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HWP19-10S |
| Pricing | Upon Request |
| Operating Temperature Range | −5 °C to 45 °C |
| Relative Humidity Limit | <95% RH |
| Ignition Method | Wireless Electronic Remote Ignition (30 m range) |
| Timer Resolution | 0.1 s |
| Ambient Temperature Measurement Range | −10 °C to +60 °C |
| Ambient Temperature Accuracy | ±0.5 °C |
| Ambient Humidity Range | 5–95% RH |
| Ambient Humidity Accuracy | ±5.0% RH |
| Test Chamber Dimensions | 30 cm × 30 cm |
| Camera Resolution | 300,000 pixels |
| Wireless Video Transmission Distance | 100 m (line-of-sight) |
| Fire Suppression Cover Dimensions | 32 cm × 32 cm × 5 cm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP20-10S |
| Pricing | Available Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HWP21-30S |
| Temperature Control Range | −10 °C to 210 °C |
| Temperature Accuracy | ±1 °C |
| Sample Temperature Measurement Range | −50 °C to 350 °C |
| Sample Temperature Resolution | 0.1 °C |
| Sample Temperature Accuracy | ≤ ±(0.15 + 0.002 |
| Gas Mixing Pressure Range | 0–110 kPa |
| Pressure Accuracy | ±0.1% FS |
| Vacuum Capability | ≤1.33 kPa |
| Leak Rate | ≤0.03 kPa/min |
| Ignition Spark Gap | 6.4 mm |
| Ignition Voltage/Current | 15 kV / 30 mA |
| Ignition Duration | 0–1 s |
| Test Vessel Options | 5 L (Ø222 mm × H345 mm) or 12 L (Ø295 mm × H378 mm) borosilicate glass |
| Stirring Speed | ≥300 rpm |
| Environmental Monitoring | Ambient Temp (−10–60 °C, ±0.5 °C), RH (5–95% RH, ±5.0% RH), Atmospheric Pressure (60–110 kPa, ±0.5 kPa) |
| Timing Range | 0–24 h |
| Timing Accuracy | ±0.01 s |
| IP Rating | IP65 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HWP22-10S |
| Price | Upon Request |
| Operating Environment | (-5 to 45)°C, <95% RH |
| Sample Type | Solids |
| Temperature Control Range | Ambient to 650°C |
| Furnace Volume | ≥2 L |
| Furnace Material | Stainless Steel + Ceramic Fiber Insulation |
| Standard Heating Rate | 0.5°C/min |
| Customizable Heating Rate | 0.1–3.0°C/min |
| Temperature Accuracy | ±0.004 |
| Temperature Measurement Range | (-40 to 1000)°C |
| Temperature Resolution | 0.1°C |
| Timer Range | 0–96 h, Timing Accuracy: ±0.01 s |
| Wire Mesh Cage Dimensions | 20 mm cube, Aperture: 0.045 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HWP23-10S |
| Pricing | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Sample Type | Liquids |
| Temperature Control Range | Ambient to 650 °C |
| Temperature Control Accuracy | ±1 °C below 350 °C |
| Temperature Measurement Range | Ambient to 800 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±(2.5 or 0.0075× |
| Atmospheric Pressure Range | 60–110 kPa |
| Pressure Accuracy | ±0.5 kPa |
| Heating Chamber Volume | 3 L |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HWP27-10S |
| Price | Upon Request |
| Operating Environment | (-5–45)°C, <95% RH |
| Chamber Temperature Range | -20°C to 220°C |
| Temperature Control Accuracy | ±1°C |
| Sample Temperature Measurement Range | -50°C to 500°C |
| Sample Temperature Resolution | 0.1°C |
| Sample Temperature Accuracy | ±(2.5 or 0.0075× |
| Dewar Volume | 1 L |
| Constant Power Regulation Range | 0.1 W–2 W |
| Constant Power Accuracy | ≤0.015 W |
| Temperature Rise Rate Range | 0–2°C/min |
| Refrigerant Circulation Flow Rate | ≥3 L/min |
| Dewar Liner Material | Borosilicate Glass |
| Dimensions (L×W×H) | 930 mm × 545 mm × 875 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Model | HWP28-10S |
| Working Environment | (-5–45)°C, <95% RH |
| Test Vessel Material | ASTM A240 S31603 Stainless Steel (316L) |
| Pressure Vessel Rating | ≥5 MPa |
| Test Vessel Volume | ≥5 L |
| Ultimate Vacuum | ≤0.1 kPa |
| Leak Rate | ≤0.01 kPa/min |
| Gas Mixing Pressure Sensor Range | 0–200 kPa |
| Gas Mixing Pressure Sensor Accuracy | ≤±0.1% FS |
| Ignition Rod Diameter | ≥3 mm |
| Ni-Cr Wire Diameter | 0.05–0.2 mm |
| Ignition Energy | 10–20 J |
| Explosion Pressure Sensor Range | 0–5000 kPa |
| Explosion Pressure Sensor Overpressure Rating | ≥10 MPa |
| Explosion Pressure Sensor Accuracy | ±0.1% FS |
| Explosion Pressure Sensor Response Time | ≤0.5 ms |
| Explosion Temperature Measurement Range | -50–350°C |
| Explosion Temperature Accuracy | ≤±(0.15 + 0.002 |
| System Sampling Frequency | ≥2 kHz |
| Timing Range | 0–24 h, Resolution: ±0.01 s |
| Magnetic Stirring Speed | ≥300 rpm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SEG-100A |
| Operating Ambient | −5°C to 45°C, <95% RH |
| Test Chamber Temperature Range | 10°C–35°C (default setpoint: 20°C, software-adjustable) |
| Temperature Stability | ±0.5°C |
| Water Addition Volume | 400 mL (automated sample immersion) |
| Sample Cup Capacity | 20 mL |
| Gas Volume Measurement Accuracy | ±0.5 mL |
| Maximum Gas Collection Capacity | 0–800 mL |
| Gas Volume Resolution | 0.01 mL |
| Gas Evolution Rate Range | 0–100 L/min/kg |
| Gas Sampling Interval | 1 s |
| Rate Calculation Interval | 1 min–1 h (software-configurable) |
| Total Timing Range | 0–240 h |
| Water Injection Volume | 300 mL |
| Water Injection Accuracy | ≤±1 mL |
| Pressure Measurement Range | −5 kPa to +5 kPa |
| Pressure Measurement Accuracy | ±0.1% FS |
| Optional Mass Measurement Range | 0–3100 g |
| Mass Measurement Accuracy | ±0.01 g |
| Water Bath Temperature Control | 20°C ±0.5°C (adjustable) |