- All
- Favorite
- Popular
- Most rated
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LabRAM Soleil™ |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–2100 nm |
| Spectral Resolution | 0.5 cm⁻¹ |
| Spatial Resolution | <250 nm |
| Minimum Wavenumber | <5 cm⁻¹ |
| Spectral Reproducibility | Better than ±0.01 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | RZ-660 |
| Price | Upon Request |
| Spectral Range | 680 – 3,800 cm⁻¹ |
| Spatial Resolution | < 5 µm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | XGT-9000 |
| Excitation Mode | Single-Wavelength Excitation |
| X-ray Tube Power | 50 W |
| Voltage Range | Up to 50 kV |
| Current Range | Up to 1000 µA |
| Elemental Coverage | Na (11) to U (92) |
| Minimum Spot Size | ≥10 µm |
| Optional Capillary Probes | 15 µm and 100 µm |
| Detector Configuration | Dual-mode — Energy-Dispersive XRF + Transmission X-ray Imaging |
| Sample Chamber Flexibility | Up to 4 configurable measurement atmospheres (air, He, vacuum, N₂) |
| Software Platform | HORIBA X-RAY LAB |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PG-300 Series |
| Product Type | Portable |
| Response Time | ≤45 s (SO₂: ≤180 s) |
| Repeatability | SO₂, NOₓ, CO, CO₂, O₂, CH₄ |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Partica CENTRIFUGE CN-300 |
| Measurement Principle | Centrifugal Sedimentation |
| Measured Range | 10 nm – 40 µm |
| Maximum Centrifugal Force | 30,000 × g |
| Temperature Control | Integrated Peltier Cooling for Sample Cell and Rotor |
| Measurement Modes | Density Gradient Mode & Homogeneous Mode |
| Sample Volume | As low as 2 µL (undiluted) or 10 µL (diluted) |
| Compliance | IEC 61010-1:2010 / IEC 61010-2-020:2016 |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | Tunable PowerArc / Tunable KiloArc |
| Output Power (Tunable PowerArc) | Up to 20 mW (wavelength-, grating-, and bandwidth-dependent) |
| Output Power (Tunable KiloArc) | >300 mW (wavelength-, grating-, and bandwidth-dependent) |
| Beam Divergence | 14.5° (PowerArc) / 14.4° (KiloArc) |
| Numerical Aperture (N.A.) | 0.12 |
| Optical Noise | 0.07% RMS |
| Power Stability | ±0.2% (over 8 hours, temperature-controlled environment) |
| Spectral Range | 180–2200 nm |
| Bandwidth Tunability | 0–25 nm (continuously adjustable) |
| Lamp Options | 75 W to 1000 W Xenon arc lamps |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | XploRA Nano |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Atomic Force Microscopy |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution (TERS mode) | <10 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | <0.1 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | OEM Customizable Spectrometer |
| Price | Upon Request |
| Spectral Range | 190–2100 nm |
| Optical Resolution | 10–1 nm (FWHM, configurable per design) |
| Focal Length | 20–140 mm |
| Detector Options | Single-channel PMT, Linear/2D CCD, CMOS, InGaAs, NMOS, PDA arrays |
| Optical Design | Monolithic Czerny–Turner or Crossed-beam configuration with Aberration-Corrected (Type-4) holographic grating |
| Compliance | Designed for integration into ISO/IEC 17025-accredited analytical systems, compatible with FDA 21 CFR Part 11–ready software environments |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LA-960 V2 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5000 µm |
| Repeatability | ±0.1% |
| Measurement Time | 10 seconds |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EV 2.0 |
| Detector Type | CCD |
| Spectral Range | 200–1050 nm |
| Dynamic Range | >3000:1 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | HCLUE |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | Signature SPM |
| Instrument Category | Atomic Force Microscope |
| Instrument Type | Materials-Focused AFM |
| Spectroscopy Integration | Confocal Raman & Photoluminescence (PL) |
| Core Capability | True Co-Localized Multimodal Imaging (Topography + Nanomechanics + Electrostatics + Magnetism + Chemical Fingerprinting) |
| Scanner Range | 100 × 100 × 15 µm |
| Optical Access | Dual-Path, IR AFM Laser (1310 nm) + Visible/NIR Excitation Lasers (e.g., 532 nm, 638 nm, 785 nm) |
| Spectrometer | Achromatic, >95% Reflectivity, Triple-Grating Support (150–6000 cm⁻¹) |
| Software Feature | “Probe Away” / “Probe Back” Automated Tip Retraction & Re-Registration |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | VS7000+ |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | 200 nm – 1050 nm |
| Spectral Resolution (UV-Vis) | 2.7 nm @ 75 µm slit, 2048-pixel array |
| Numerical Aperture | f/2.8 |
| Stray Light Suppression | ≤ 0.08% (max) |
| Dynamic Range | 7000:1 |
| Quantum Efficiency | >65% at 250 nm, >70% at 650 nm, >55% at 850 nm |
| Readout Speed | up to 223 spectra/s (ultra-fast mode, zero exposure) |
| A/D Conversion | 16-bit, 500 kHz |
| Dark Current | 2.8 counts/ms @ 20°C |
| Read Noise | ≤45 e⁻ (sensitive mode), ≤90 e⁻ (high full-well mode) |
| Linearity Error (factory corrected) | <0.4% (sensitive mode), <0.8% (high full-well mode) |
| On-board Linearization & Wavelength Calibration | Yes |
| Interface | USB 2.0 |
| Optical Design | Monolithic aberration-corrected Czerny–Turner with Type-4 flat-field concave holographic grating |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | NanoLog® |
| Dispersion Element | Grating |
| Slit (Spectral Bandpass) | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Wavelength Accuracy | Not Specified |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Space-Grade Diffraction Grating |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ultima Expert |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | ≤1% |
| Long-Term Stability (RSD) | ≤2% |
| Wavelength Range | 160–800 nm |
| Optical Resolution | ≤0.005 nm at 200 nm (Constant Resolution Across Full Range) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iHR320 / iHR550 |
| Application System | Universal |
| Grating Mount | Dual-grating turret (motorized, selectable) |
| Spectral Resolution | 0.06 nm (iHR320), 0.025 nm (iHR550) |
| Linear Dispersion | 2.31 nm/mm (iHR320), 1.34 nm/mm (iHR550) |
| Wavelength Range | 150 nm – 40 µm |
| F-number | f/4.1 (iHR320), f/6.4 (iHR550) |
| Wavelength Accuracy | ±0.20 nm |
| Stray Light | 1.5 × 10⁻⁴ (iHR320), 1.0 × 10⁻⁵ (iHR550) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | UVISEL |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Standard Plane Grating |
| Pricing | Upon Request |
| Type | Replicated Grating |
| Dimensions | 120 × 140 mm |
| Spectral Range | 100 nm – 45 µm |
| Groove Density | 20 – 5670 grooves/mm |
| Diffraction Efficiency | 30% – 90% |
| Substrate Materials | Fused Silica, Heat-Resistant Glass, Zerodur®, Metal |
| Coating Options | Aluminum, Gold, Platinum, Magnesium Fluoride |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SZ-100 V2 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Characterization System |
| Size Range | 0.3 nm – 10 µm |
| Reproducibility | ±2% |
| Measurement Time | < 2 min |
| Zeta Potential Range | −500 mV to +500 mV |
| Molecular Weight Range | 1,000 – 2×10⁷ Da |
| Detection Angles | 90° and 173° (automatically or manually selectable) |
| Sample Volume | 12 µL – 1,000 µL |
| Measurement Principle for Size | Dynamic Light Scattering (DLS), also known as Photon Correlation Spectroscopy (PCS) |
| Zeta Potential Principle | Laser Doppler Electrophoresis |
| Molecular Weight Determination | Debye Plot Analysis |
| Second Virial Coefficient (A₂) | Yes |
| Integrated Auto-Titrator | Yes (for pH-controlled zeta potential studies) |
| Compliance | NIST-traceable calibration with 100 nm standard particles |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | VA-5000 |
| Detection Range | CO, CO₂, NOₓ, SO₂, CH₄, C₂H₄, N₂O, O₂ |
| Repeatability | ±1.0% F.S. |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MicroHR |
| Price | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | H1034 (Single-Stage) |
| Grating Mount | Motorized 3-Grating Turret |
| Spectral Resolution | ≤5 nm (with 100 µm slit) |
| Wavelength Range | 200–1200 nm (optional blaze wavelengths: 250 nm, 350 nm, 500 nm) |
| F-number | F/2.8 |
| Stray Light | < 0.1% (typical) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Symphony CCD |
| Price | Upon Request |
Show next