Industrial Process Control Instruments
Filter
Showing 721–750 of 1088 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Range | InPro 2000, InPro 2002, InPro 3x00, InPro 4x00, InPro 5x00, InPro 7x00 |
| Electrode Architecture | Combination pH/ORP sensor with integrated reference system |
| Intelligent Sensor Management (ISM) | Real-time electrode health monitoring including glass membrane impedance, reference junction resistance, response time, and service life estimation |
| Temperature Compensation | Integrated Pt1000 or Pt100 RTD |
| Process Connection | Standardized ¾" NPT, DIN 19213, or sanitary Tri-Clamp fittings |
| Pressure Rating | Up to 10 bar (varies by model) |
| Temperature Range | –10 °C to +130 °C (model-dependent) |
| Certifications | ATEX/IECEx Zone 1, FM Class I Div 1, SIL2 compliant per IEC 61508, FDA 21 CFR Part 11 ready (when paired with compatible transmitter) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro2000 / InPro2000i |
| pH Range | 0–14 |
| Temperature Range | 0–140 °C (32–284 °F) |
| Max. Pressure Rating | 6 bar (87 psi) |
| Junction | Ceramic |
| Reference System | Ag/AgCl with Silver Ion Trap |
| Sterilizable | Yes |
| ATEX Certification | Ex II 1/2G EEx ia IIc T6/T5/T4/T3, SNCH 00 ATEX 3130X FM Certified for Class I, II, III |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro3250 / InPro3250SG / InPro3250i |
| pH Range | 0–14 (InPro3250), 0–12 (InPro3253) |
| Temperature Range | 0–140 °C (32–284 °F) |
| Max. Process Pressure | 4 bar (58 psi) |
| Reference System | Ceramic junction, Ag/AgCl |
| Optional Features | Silver-ion trap (SG models), Solution Grounding (SG), ISM digital interface, ATEX certification (II 1/2G EEx ia IIC T6/T5/T4/T3), FM/CSA Class I Div 1, IP68 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro4260 |
| pH Range | 0–14 |
| Temperature Range | 0–130 °C |
| Max. Pressure | 16 bar (25 °C), 8 bar (130 °C) |
| Reference System | XEROLYT® EXTRA polymer-based electrolyte with KCl |
| Junction Type | Open liquid junction |
| Integrated Temperature Sensor | Pt100 or Pt1000 |
| ATEX Certification | II 1/2G EEx ia IIc T6–T3 |
| FM Approval | Class I, II, III |
| IP Rating | IP68 (VP connector) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro4800 |
| pH Range | 0–14 |
| Temperature Range | −5 to 130 °C |
| Max. Operating Pressure | 13 bar (at 130 °C) / 188 psi (at 266 °F) |
| Safety Factor | 3 |
| Diaphragm | External PTFE annular junction, internal non-flowing diaphragm |
| Reference System | Patented dual-gel electrolyte chamber with pressure compensation, Ag/AgCl |
| Certifications | ATEX II 1/2G Ex ia IIc T6/T5/T4, FM IS Class I, Div 1, Groups A–D |
| Compliance | IEC 60079-0, IEC 60079-11, UL 913 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | InPro5000i (for bioprocessing & cell culture), InPro5500i (for beverage carbonation) |
| Measurement Principle | Severinghaus-type electrochemical membrane sensor with temperature-compensated pH-based detection |
| Output Signal | 4–20 mA, HART, or digital ISM interface |
| Pressure Rating | Up to 10 bar (g) |
| Process Temperature Range | 0–50 °C |
| Materials of Construction | PPSU body, PTFE/PFA membranes, FDA-compliant wetted parts |
| Certifications | ATEX/IECEx Zone 1, SIL2 compliant, cGMP-ready design |
| Smart Features | ISM (Intelligent Sensor Management) with diagnostic logging, lifetime calibration tracking, and predictive maintenance alerts |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | InPro8100 Series |
| Application Domain | Bioprocess Monitoring (Microbial Fermentation & Mammalian Cell Culture) |
| Compliance | Designed for GMP/ISO 13485-aligned biomanufacturing environments |
| Installation Options | Tank-mounted, inline pipe flow cell, submersible probe |
| Measurement Principle | Near-infrared (NIR) optical absorbance at 850 nm |
| Output Signal | 4–20 mA, HART, or digital Modbus RTU/TCP |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ParticleTrack G400 / G600 / G600B / G600EX |
| Measurement Principle | Focused Beam Reflectance Measurement (FBRM) |
| Particle Size Range | 0.5–2000 µm |
| Laser Class | Class 1 |
| Probe Pressure Rating | 3–300 barg (model-dependent) |
| Probe Temperature Rating | −80 to +150 °C (model-dependent) |
| Scan Speed | 2 m/s (1.2 m/s for 19 mm probe) |
| Probe Window Material | Sapphire |
| Sealing Material | Viton™ (G400), Kalrez® (G600 series) |
| Enclosure Rating | IP66 (G600B/G600EX) |
| Compliance | CE, NRTL, CB Scheme, FDA 21 CFR Part 11 (with iC Process software), GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | pH and ORP (Redox) Combination Electrode |
| Connector | VP (Versatile Plug) |
| Construction | Gel-Filled or Solid-State Reference System |
| Temperature Compensation | Integrated Pt1000 or NTC Sensor |
| Compliance | Designed for ASTM D1293, ISO 10523, USP <791>, FDA 21 CFR Part 11 (when used with compliant transmitters) |
| Application Environment | Continuous online measurement in industrial process streams, wastewater, pharmaceutical water systems, and ultrapure water (UPW) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Pt4865-50-SC-T-S7 |
| pH Range | Not applicable (ORP-only electrode) |
| ORP Measurement Range | Typically ±1500 mV (standard reference: Ag/AgCl, 3 mol/L KCl) |
| Temperature Range | 0–130 °C (32–266 °F) |
| Maximum Process Pressure | 6 bar (87 psi) |
| Reference System | Ag/AgCl with silver ion trap |
| Junction Type | Porous ceramic diaphragm |
| Refillable Electrolyte | Yes (Viscolyt™ liquid electrolyte) |
| Sterilizable | Yes (autoclavable up to 130 °C) |
| High-Pressure Housing Compatible | Yes |
| Compliance | Designed for IEC 61511 functional safety support in SIS applications |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SevenGo Duo Pro (pH/FiveGo Dual-Channel) |
| Protection Rating | IP67 |
| Compliance | GLP-supported |
| Connectivity | Infrared (IR) interface for PC/printer data transfer |
| Display | Backlit high-contrast LCD |
| Data Storage | Internal memory with timestamped records |
| Ergonomic Design | Handheld, field-optimized form factor |
| Channel Configuration | Dual-channel simultaneous measurement |
| Certifications | CE, RoHS, compliant with ISO/IEC 17025 laboratory practice guidelines |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Channel Configuration | Dual-Channel (pH/mV + DO or Conductivity) |
| IP Rating | IP67 |
| Compliance | GLP-compliant |
| Connectivity | Infrared (IR) interface for data transfer to PC or printer |
| Display | Backlit LCD with electrode status indicator |
| Ergonomic Design | Handheld, field-optimized form factor |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measurement results) |
| Sensor Types Supported | 8 (including pH/ORP, conductivity/resistivity, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 analog outputs (0/4–20 mA), RS232 serial interface, up to 4 relay outputs (optional) |
| Display | Multi-line scrolling LCD with customizable parameter labeling |
| Power Supply | Universal AC 100–240 V, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated front panel, sealed rear cover |
| Calibration | NIST-traceable verification & calibration via optional 1875 Smart Calibrator |
| Smart Sensor Compatibility | Thornton intelligent sensors with embedded NVRAM for auto-recognition, calibration data storage, and plug-and-play operation |
| Measurement Units | 35 configurable units across parameters |
| Temperature Compensation | Integrated, parameter-specific algorithms |
| Data Timestamping | Internal real-time clock for all measurements and calibration events |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | InPro7250 Series |
| Sensor Principle | Toroidal (Electrodeless) Induction |
| Measurement Parameters | Conductivity, Resistivity, Salinity (TDS-derived), Temperature |
| Output Protocols | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Enclosure Rating | IP66/IP67, ATEX/IECEx Certified Options Available |
| Channel Configuration | Single- or Dual-Channel Transmitter Options |
| Compliance | FDA 21 CFR Part 11 (with ISM software), ASTM D1125, ISO 7888, USP <645>, EP 2.2.38 |
| Brand | MICHEM |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hyscan II |
| Pricing | Upon Request |
| Dimensions (W×D×H) | 600 × 600 × 1000 mm |
| Weight | 120 kg |
| Power Supply | 220 V / 50 Hz, 5 m armored cable |
| Sample Mass | 100 g |
| Measurement Time | < 5 min |
| Measurement Range | 0.01–1.99 cm³/100 g |
| Sensitivity | 0.01 cm³/100 g |
| Accuracy | ±5% (vs. vacuum fusion reference method) |
| Compliance | LMFA Certified |
| Brand | MICHEM |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Hyscan II |
| Price Range | USD 68,000–95,000 |
| Dimensions (W×D×H) | 600 mm × 600 mm × 1000 mm |
| Weight | 120 kg |
| Power Supply | 220 V AC, 50 Hz, armored 5-m power cable |
| Sample Mass | 100 g |
| Measurement Time | < 5 minutes |
| Detection Range | 0.01–1.99 cm³/100 g |
| Sensitivity | 0.01 cm³/100 g |
| Accuracy | ±5% (vs. vacuum fusion reference method) |
| Certification | LMFA (Light Metals Federation of America) Manufacturing License |
| Brand | MJK |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MJK Electromagnetic Flow Meter |
| Pricing | Upon Request |
| Brand | MJK |
|---|---|
| Origin | Denmark |
| Model | MJK Shuttle |
| Measurement Principle | Non-contact ultrasonic time-of-flight (ToF) |
| Output Signals | 4–20 mA (field-adjustable zero & span), 2 programmable relay outputs |
| Display | Backlit LCD with bar graph and numeric readout (5 selectable units: m, ft, %, cm, in) |
| Beam Angle | <6° (narrow-focus transducer) |
| Certification | FM Class I, Div 1, Groups C/D |
| Application Environment | Outdoor, wastewater, potable water, industrial tanks, open channels, pump stations |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Models | Three Configurable Systems (CO/CO₂/H₂O/O₂ Integrated) |
| Price Range | USD 4,200 – 7,000 (FOB Beijing) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Modul1000 |
| Pricing | Upon Request |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek |
| Measurement Principle | 12° Forward Light Scattering |
| Detection Range | 0–0.5 mg/L to 0–8000 mg/L (oil or water phase) |
| Optical Wavelength | 380–1100 nm |
| Repeatability | ±1% |
| Flow Cell Material | 316L Stainless Steel (Ti/PTFE optional) |
| Window Material | Sapphire (Borosilicate/PMMA optional) |
| Seal Material | FKM (FFKM/EPDM/Silicone optional) |
| Process Connection | DIN/ANSI Flange, NPT |
| Max. Process Pressure | PN16 / ANSI Class 150 |
| Max. Process Temperature | 140 °C |
| IP Rating | IP65 / NEMA 4X |
| ATEX Certification | Ex d IIC T6 (Zone 1 & Zone 2) |
| Cleaning | CIP-compatible, optional spray nozzle |
| Calibration Interval | Up to 24 months (application-dependent) |
| Power Supply | 90–260 VAC, 50–60 Hz (24 VAC/DC optional) |
| Analog Outputs | Up to 4 × 4–20 mA (independent) |
| Digital Interface | RS-232C / RS-485 (Modbus RTU) |
| Relay Outputs | 4 programmable (48 V / 2 A) |
| Data Logger | 8,000-point internal memory with backup restore |
| Environmental Operating Range | −10 °C to +50 °C |
| Power Consumption | ≤50 VA |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek Ultrasonic |
| Measurement Principle | Ultrasonic Reflectance |
| Frequency Options | 5 MHz / 15 MHz |
| Enclosure Rating | NEMA 4X / IP65 |
| Max Process Pressure | 20 bar (customizable higher) |
| Max Process Temperature | 90°C (110°C with air cooling) |
| Sensor Material | 316 SS / PEEK |
| Sensor Length | ~300 mm (custom lengths available) |
| Cable Length | 100 m |
| Measurable Range | 0–100 ppm to 0–10,000 ppm (configurable |
| Output Units | ppm, mg/L, %, EBC, etc. |
| Accuracy | ±1% |
| Hazardous Area Certifications | Ex Zone I, Ex Zone II, Class 1 Div. 1 |
| Maintenance | No consumables |
| Installation | Retractable probe via 1" ball valve adapter |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MPA48 |
| Price Range | USD 4,200 – 7,000 |
| Resolution | 0.01 ppm (DO) |
| Measurement Range | DO: 0–25 ppm |
| SS | 0–30,000 mg/L |
| pH | 2–12 |
| ORP | ±2000 mV |
| Repeatability | ±1% (SS), 0.01 ppm (DO) |
| Stability | <1% per year (DO & SS) |
| Temperature Compensation | 0–60 °C (DO/SS), 10–100 °C (pH/ORP) |
| Communication Interfaces | 4–20 mA (up to 8 channels), RS232/RS485, relay outputs (8 dry-contact, 1 alarm, 1 clean signal) |
| Dimensions | 30 cm × 20 cm × 10 cm |
| Operating Ambient Temperature | −20 to +70 °C |
| Enclosure Rating | NEMA 4X |
| Max Pressure Rating | 100 psi |
| Sensor Cable Standard Length | 10 m (optional up to 610 m) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ViscoLiner |
| Price Range | USD 14,000 – 70,000 |
| Measurement Range | 0.1–1,000,000 cP |
| Temperature Range | −40 °C to +450 °C |
| Max Pressure Rating | 350 bar |
| Repeatability | ±0.25% |
| Accuracy | ±2% |
| Response Time | 1 s |
| Integrated Temperature Sensor | PT100 RTD |
| Temperature Compensation | Yes |
| Flow-Immune Measurement Principle | Vibrational Resonance |
| Brand | Neutronics |
|---|---|
| Origin | USA |
| Model | 5100 |
| Sensor Type | Electrochemical (Zirconia-based) |
| Measurement Range | 0–1%, 0–10%, 0–25%, 0–50%, or 0–100% O₂ (auto-ranging or fixed-range selectable) |
| Display | 0.75" (19.05 mm) high-brightness LED numeric display with status LEDs (green = normal operation, yellow = system fault, red = alarm 1 or 2) |
| Response Time (t₉₀) | <15 s |
| Accuracy | ±2% FS at constant temperature |
| Operating Temperature | 5–45 °C |
| Output Signals | 4–20 mA, 0–10 VDC (also supports 0–1 VDC and 0–5 VDC), RS-232 serial interface |
| Alarm Outputs | Two configurable relay outputs |
| Sample Connection | 1/8" NPT female port |
| Power Supply | 115/230 VAC, 50/60 Hz, 10 W or 12–30 VDC |
| Enclosure Rating | Front panel — IP66 (MEWA4) |
| Weight | <0.9 kg |
| Warranty | 12 months from shipment date under normal operating conditions |
| Compliance | Designed for industrial process environments |
| Brand | Neutronics |
|---|---|
| Origin | USA |
| Model | Model 3100 |
| Sensor Type | High-Stability Zirconia Electrolyte Sensor |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, or 0–100% O₂ (auto-ranging or fixed-range configuration) |
| Display | 0.75" (19.05 mm) LED numeric display with status LEDs (green = normal/online, yellow = fault), dual alarm indicators |
| Response Time | <10 seconds (T₉₀) |
| Accuracy | ±2% FS at constant temperature |
| Operating Temperature | 5–45 °C |
| Output Signals | RS-232 serial interface |
| Alarm Outputs | Two programmable SPDT relay outputs (configurable for high/low/alarm latching or trip functions) |
| Sample Inlet | 1/4" compression fitting |
| Electrical Connection | Plug-in terminal block |
| Power Supply | 5 W, 115/230 VAC 50/60 Hz or 12–30 VDC |
| Enclosure Rating | Front panel: NEMA 4 / IP66 |
| Housing | NEMA 1 / IP20 |
| Expected Sensor Lifetime | 5–10 years under typical industrial conditions |
| Compliance | Designed for continuous emission monitoring and process safety applications in accordance with general industrial instrumentation standards (IEC 61000-6-2/6-4, UL 61010-1, CE) |
| Brand | Neutronics |
|---|---|
| Origin | USA |
| Model | 7100P |
| Sensor Type | Miniature Heated Zirconia |
| Measurement Range | 0–1000 ppm O₂ (max 1% O₂) |
| Display | 0.75" (19.05 mm) High-Brightness LED, Resolution: 0.1 ppm |
| Response Time | <15 s (T90, at 500 mL/min flow) |
| Accuracy | ±3 ppm (0–50 ppm, two-point calibration) |
| Operating Temperature | 0–45 °C |
| Storage Temperature | −15–+50 °C |
| Humidity | 0–95% RH non-condensing |
| Sample Flow Rate | 0.4–1 L/min (constant pressure) |
| Power Supply | 90–250 VAC, 50/60 Hz, 10 W |
| Warm-up Time | ~2 minutes |
| Output Signals | RS-232, 4–20 mA, 0–10 VDC (optional: 0–1 VDC, 0–5 VDC) |
| Sample Port | 1/8" NPT female |
| Weight | <2.2 kg |
| Warranty | 1 year (electronics & sensor) |
| Alarm Indicators | Dual LED alarms (Alarm 1 & Alarm 2), Status LEDs (green = normal/online |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGC 8200 |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NMI20-ta |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Static Magnetic Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameters | 25 mm and 40 mm |
| Measurement Principle | Proton (¹H) NMR Relaxometry |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PQ001-xx |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameter | 25 mm |