Industrial Process Control Instruments
Filter
Showing 661–690 of 1088 results
| Key | Brand: Leici |
|---|---|
| Model | PHG-7685A |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.05 pH ±1 digit |
| Temperature Range | −10.0–120.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.5 °C (0.0–60.0 °C), ±1.0 °C (others) |
| Repeatability | 0.02 pH |
| Electronic Unit Error | ±0.03 pH ±1 digit |
| Stability | ≤±0.02 pH/24 h |
| Input Impedance | ≥1×10¹² Ω |
| Input Current | ≤2×10⁻¹² A |
| Output | 4–20 mA isolated analog output, RS-232 or RS-485 (user-selectable) |
| Enclosure Rating | IP65 |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 % |
| Dimensions | 628 × 288 × 224 mm |
| Weight | 10 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PHG-7685A |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Measurement Range | (0.00–14.00) pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.05 pH ±1 digit |
| Dimensions | 628 × 288 × 224 mm |
| Weight | 10 kg |
| Temperature Range | −10.0 to 120.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.5 °C (0.0–60.0 °C), ±1.0 °C (other) |
| Repeatability | 0.02 pH |
| Electronic Unit Accuracy | ±0.03 pH ±1 digit |
| Drift Stability | ≤±0.02 pH / 24 h |
| Input Impedance | ≥1 × 10¹² Ω |
| Input Current | ≤2 × 10⁻¹² A |
| Enclosure Rating | IP65 |
| Power Supply | AC (220 ± 22) V, (50 ± 0.5) Hz |
| Output | Isolated 4–20 mA DC (configurable pH span), RS-232 or RS-485 (user-selectable) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PHGF-46 |
| Pricing | Available Upon Request |
| Flow Cell Configurations | P2N1, P2Y1, P3N1, P3Y1, P4N0, P4Y0, S1N1, S1Y1 |
| Pre-amplifier | Integrated (Y) or Not Integrated (N) |
| Compatible Electrodes | FG-991A (pH), FG-990 + T-819-A (pH/ORP combo), T-819-A (temperature) |
| Measuring Range | pH 0–14 |
| Sample Temperature Range | 0–55 °C (standard) |
| Max Process Pressure | 0.6 MPa |
| Housing Material Options | PVC (A=P), CPVC (A=C), SS304 (A=T), SS316 (A=S) |
| Flow Cell Types | FT-01 (inline straight), FS-02 (T-fitting), FX-03/FX-04 (angled insertion, FX-04 supports integrated Pt100 temperature sensor) |
| Inlet/Outlet Connections | 1", 1/2", 3/4" NPT or BSP |
| Tubing Inlet | Φ6×1 mm stainless steel or PVDF |
| Tubing Outlet | Φ10×1 mm stainless steel or PVDF |
| Standard Cable Length | 10 m (custom lengths available on request) |
| Brand | Leici |
|---|---|
| Model | PHSJ-4F |
| Measurement Range | pH (−2.000 to 20.000), mV (−2000.00 to 2000.00), Temperature (−10.0 to 135.0 °C / 14.0 to 275.0 °F) |
| Resolution | pH (0.001/0.01/0.1), mV (0.01/0.1/1), Temp (0.1 °C/0.1 °F) |
| Accuracy | pH ±0.002, mV ±0.03% or ±0.1 mV, Temp ±0.1 °C (electronic unit), ±0.3 °C (0.0–60.0 °C), ±1.0 °C (other ranges) |
| Calibration | 1–5 point pH auto-calibration with buffer recognition (GB, DIN, NIST, USA, MERK) and custom buffer support |
| Data Storage | 500 sets with time stamping, filtering, export via USB/RS-232, GLP-compliant audit trail |
| Display | 7-inch HD color LCD |
| Interface | RS-232 (printer compatible), USB-B (PC communication) |
| Power | AC 100–240 V input, DC 20 V output adapter |
| Dimensions | 242 × 195 × 68 mm |
| Weight | ~0.9 kg |
| IP Rating | IP54 |
| Compliance | GB/T 11165–2005, JJG 119–2018, HJ 1396–2024 |
| Brand | Leici |
|---|---|
| Model | PHSJ-5T |
| Measurement Range | (−2.00 to 20.00) pH |
| Resolution | 0.01 pH (selectable down to 0.001 pH) |
| Accuracy | ±0.001 pH |
| Temperature Compensation Range | (−5.0 to 105.0) °C |
| Dimensions | 240 mm × 180 mm × 78 mm |
| Weight | 1.5 kg |
| IP Rating | IP54 |
| Data Storage Capacity | 1000 datasets (pH, mV, ORP, temperature) |
| Compliance | GLP, GMP-ready, 21 CFR Part 11–compatible data management via optional software |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SJG-203A |
| Price Range | USD 1–4,999 |
| Resolution | 0.01 mg/L, 0.1%, 0.1°C |
| Measurement Range | (0.0–20.00) mg/L DO, (0.0–200.0)% saturation |
| Repeatability | ≤0.20 mg/L |
| Stability | ±0.20 mg/L / 24 h |
| Temperature Compensation Range | (−10.0–120.0)°C |
| Communication Interface | RS-232 |
| Dimensions & Weight | 160 × 160 × 110 mm, 1 kg |
| Basic Accuracy | ±0.5 mg/L (DO), ±10.0% (saturation), ±1.0°C (temperature) |
| Electronic Unit Accuracy | ±0.20 mg/L (DO), ±5.0% (saturation), ±0.3°C (temperature) |
| Salt Compensation Range | (0.0–50.0) g/L |
| Salt Compensation Error | ≤±3% |
| 90% Response Time | ≤45 s (at 20°C) |
| Enclosure Rating | IP65 |
| Power Supply | AC (220 ± 22) V, (50 ± 1) Hz |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | SJG-209 |
| Price | USD 1,380 (FOB Shanghai) |
| Resolution | 0.01 mg/L |
| Measurement Range | (0.0–20.0) mg/L |
| Repeatability | ≤ 0.20 mg/L |
| Stability | ±0.20 mg/L / 24 h |
| Temperature Compensation Range | (0.0–50.0) °C |
| Communication Interface | RS-485 |
| Dimensions | 166 × 166 × 110 mm |
| Weight | 2.5 kg |
| DO Saturation Range | (0.0–200.0) % |
| Temperature Range | (0.0–50.0) °C |
| DO Accuracy | ±0.30 mg/L |
| Saturation Accuracy | ±10.0 % |
| Temperature Accuracy | ±0.2 °C |
| Output Signal | Isolated 4–20 mA DC, max load 600 Ω |
| Alarm Outputs | 2 relay outputs (220 V AC, 2.5 A resistive) |
| Cleaning Control Output | 1 programmable relay output (220 V AC, 2.5 A) |
| Data Storage | 2000 records with timestamp |
| Enclosure Rating | IP65 |
| Power Consumption | 10 W |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Model | SE301 |
| Sensor Type | Electrochemical (low-range) & Optional Paramagnetic |
| Measurement Ranges | 0–500 ppm, 0–1%, 0–5.0%, 0–10.0%, 0–25.0%, 0–50.0%, 0–100% O₂ |
| Accuracy | ±1% of reading (full-scale dependent) |
| Response Time (T90) | 8–10 s (electrochemical) |
| Repeatability | ±1% FS |
| Resolution | 0.1 ppm (0–500 ppm range), 0.1% (higher ranges) |
| Display | Backlit LCD with real-time digital readout |
| Sampling System | Integrated diaphragm pump, stainless-steel probe (12 ft PTFE-lined sampling hose), dual-stage particulate/moisture filter, flow meter, automatic condensate removal trap |
| Data Interface | USB port, optional data logger support |
| Power | Rechargeable Li-ion battery (≥8 h continuous operation), AC adapter included |
| Enclosure | IP65-rated ruggedized housing |
| Compliance | Designed to meet requirements of HJ 57–2017 (China), GB/T 16157–1996, and supports method principles aligned with ASTM D4084–22 (electrochemical O₂) and ISO 10156 (paramagnetic O₂ detection) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA-8500 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA-9500 |
| Pricing | Available upon Request |
| [Brand | LightQ / Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | Acona LE Mini |
| Pricing | Upon Request] |
| Brand | LISICO |
|---|---|
| Model | Online 1 |
| Measurement Principle | Mie & Fraunhofer Light Scattering |
| Test Range | 0.1–1000 µm |
| Repeatability Error | ≤1% (D50 of certified reference material) |
| Accuracy Error | ≤1% (D50 of certified reference material) |
| Sampling Method | Venturi-based negative-pressure sampling with anti-clogging design |
| Lens Protection | Dual-air-curtain optical protection |
| Maintenance Interval | ≥180 days |
| Laser Source | Imported semiconductor laser |
| Detector Array | 68-element photodiode array |
| Operating System | Windows |
| Communication Protocols | Modbus RTU, TCP/IP, 4–20 mA analog output |
| Dispersing Medium | Compressed air or inert gas (N₂) |
| Gas Supply | 0.4–0.8 MPa, ≥1000 L/min |
| Filtration System | 4-stage imported precision filter (particulate, oil, moisture removal) |
| Sample Throughput | 2–20 g per cycle |
| Power Supply | AC 220 V, 50/60 Hz, 90 W |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 800 × 280 × 280 mm |
| Weight | 21 kg |
| Compliance | GB/T 19077–2016, ISO 13320:2009, Q/ASA 001–2021 |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Online 2 |
| Pricing | Upon Request |
| Brand | LongerPump |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | YT600-1J |
| Drive Motor | DC |
| Enclosure Material | Full 304 Stainless Steel |
| Protection Rating | IP54 |
| Power Supply | AC 220 V ±20%, 400 W |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH |
| Dimensions (L×W×H) | 325×236×193 mm |
| Weight | 20 kg |
| Speed Range | 60–600 rpm |
| Direction | Reversible (CW/CCW) |
| Flow Rate (per single channel) | 600–11,000 mL/min |
| Compatible Pump Heads | YZ35-13, KZ35 |
| Control Interface | Manual knob + push-button + analog/digital external input (4–20 mA / 1–10 V / 1–10 kHz) |
| Auto-Restore Function | Yes (power-loss memory) |
| Full-Speed Mode | Dedicated hardware button |
| External Connector | Waterproof aviation-grade socket |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LTGA-200 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LTGA-700 |
| Pricing | Available upon Request |
| Brand | ONUEE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Industrial Analyzer |
| Model | PMA1000 |
| Price | Upon Request |
| Key | Brand: MAGNETROL |
|---|---|
| Model | Aurora® Magnetic Level Indicator |
| Measurement Principle | Buoyancy + Magnetic Coupling + Guided Wave Radar (GWR) |
| Process Pressure | Up to 310 bar |
| Process Temperature | Up to 425 °C |
| Minimum Medium Specific Gravity | 0.25 |
| Construction | All-metal, ASME U- and UM-stamped, PED-compliant, NACE MR0175/ISO 15156 certified |
| Indicator | Patented Reveal® wide-view magnetic display |
| Options | Remote-mounted electronics, custom range calibration, multiple process connections (ANSI, DIN, JIS), high-temperature & cryogenic insulation, external reed switches, pneumatic/electrical level switches |
| Compliance | ASME B31.1, ASME B31.3, PED 2014/68/EU, NACE MR0175/ISO 15156 |
| Brand | MAGNETROL |
|---|---|
| Model | Echotel® 355 Series |
| Measurement Principle | Non-contact ultrasonic (60 kHz) |
| Power Supply | 2-wire loop-powered (4–20 mA/HART®) |
| Max. Range | 6 m |
| Output Signal | 4–20 mA with HART® v7 protocol |
| Temperature Compensation | Built-in |
| Echo Processing | Dynamic baseline noise suppression, false echo rejection |
| Flow Calculation | Integrated standard open-channel flow algorithms (e.g., Palmer-Bowlus, Parshall, Palmer-Bowlus, Trapezoidal) |
| Accumulation Options | Resettable and non-resettable flow totalizers |
| Housing Materials | Cast aluminum or Lexan® polymer enclosure |
| Sensor Materials | Polypropylene or Kynar® (PVDF) transducer housing |
| Software Configuration | PACTware-compatible via USB/4–20 mA loop |
| Compliance | Designed for industrial environments per IEC 61000-6-2/-6-4 (EMC), IP66/IP67 ingress protection, SIL 2 capable per IEC 61508 (when used in safety loops with appropriate logic solver) |
| Brand | MAGNETROL |
|---|---|
| Model | Echotel® 910 Series |
| Type | Ultrasonic Level Switch |
| Mounting | Integral (One-Piece) Design |
| Output | 8 A DPDT Gold-Plated Contacts or 5 A DPDT Hermetically Sealed Relay |
| Adjustable Alarm | Field-Configurable High/Low Setpoint |
| Installation Orientation | Vertical or Horizontal |
| Calibration | Zero Calibration Required |
| Certification | ATEX, IECEx, CSA, FM Intrinsically Safe and Flameproof Options Available |
| Enclosure Material Options | 316 Stainless Steel, Polyphenylene Sulfide (PPS), Aluminum |
| Process Connections | NPT, BSPP, Tri-Clamp, Flanged |
| Operating Voltage | 24 VDC, 115 VAC, 230 VAC |
| Sensor Length Options | 25 mm to 1500 mm |
| Compliance | Designed and tested per IEC 61508 SIL 2 capable (per system configuration), meets UL 61010-1, EN 61000-6-2/6-4, RoHS |
| Brand | MAGNETROL |
|---|---|
| Model | Echotel® 961 (Single-Point) / Echotel® 962 (Dual-Point) |
| Measurement Principle | Pulse-Echo Ultrasonic |
| Safety Certification | SIL 2 per IEC 61508 |
| Installation Options | Integral or Remote Mount |
| Probe Materials | Stainless Steel 316L or FDA-Compliant PTFE-Coated Polymer |
| Operating Voltage | 24 VDC (±15%) or 115/230 VAC (50/60 Hz) |
| Output Signal | SPDT Relay (Configurable Fail-Safe) |
| Environmental Rating | IP67 / NEMA 4X |
| Temperature Range | –40 °C to +85 °C (Process Side), –20 °C to +60 °C (Electronics) |
| Pressure Rating | Up to 10 bar (145 psi) |
| Compliance | ATEX II 2G Ex db IIC T6 Gb, IECEx DBI22.0027X, UL/cUL Class I Div 1 Groups B, C, D, FM Class I Div 1 Groups B, C, D |
| Brand | MAGNETROL |
|---|---|
| Model | Eclipse® 700 Series |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Power Supply | 24 VDC loop-powered |
| Output Signal | 4–20 mA with HART® digital communication |
| Intrinsic Safety Certification | FM, ATEX, IECEx (ia IIC T6 Ga) |
| Explosion-Proof Rating | Non-sparking (nA) |
| SIL Rating | SIL 2 / SIL 3 per IEC 61508 (SFF = 93%, FMEDA available) |
| Process Temperature Range | –196 °C to +220 °C (–320 °F to +400 °F) |
| Process Pressure Range | Full vacuum to 43 MPa (6250 psi) |
| Accuracy | ±2 mm typical (dependent on probe type and installation) |
| Probe Options | Flexible cable, rigid rod, coaxial, twin-lead |
| Display Option | Integrated LCD with echo curve visualization |
| Compliance | IEC 61000-6-2/-6-4, IEC 61326-1, NAMUR NE 21/NE 43, FCC Part 15 Subpart B |
| Brand | MAGNETROL |
|---|---|
| Model | Eclipse® 706 Series |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Power Supply | 24 VDC loop-powered |
| Output Signal | HART® or Foundation Fieldbus™ or Modbus RTU |
| Explosion Protection | Intrinsically Safe (IS), Flameproof (Ex d), Non-incendive (NI) certified |
| Process Pressure Range | Full vacuum to 43 MPa (6250 psi) |
| Process Temperature Range | –196 °C to +450 °C (–320 °F to +850 °F) |
| SIL Rating | SIL 2/3 compliant (SFF = 93% |
| Diagnostic Capability | Advanced self-diagnostics with echo curve visualization |
| Probe Types | Rigid rod, flexible cable, coaxial, and dual-rod configurations |
| Display Option | Integrated LCD with real-time echo profile |
| Compliance | IEC 61508, IEC 61511, ATEX, IECEx, CSA, FM, NEMA 4X/IP66 |
| Brand | MAGNETROL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Level Meter |
| Model | Gemini™ Magnetic Level Indicator with Modular Instrumentation Bridge (MIB) |
| Application Scope | Feedwater Heaters, Boilers, Oil-Water Separators, Flash Drums, Pressure Regulation Vessels, Gas Coolers |
| Redundancy Architecture | Dual-Principle Measurement Integration |
| Customization | Fully Configurable MIB Platform |
| Compliance Context | Designed for ASME BPVC Section VIII, ISA-5.1, IEC 61511 SIL2-capable system integration |
| Brand | MAGNETROL |
|---|---|
| Model | Genesis™ ED1 & ED2 Series |
| Measurement Principle | Guided Wave Radar (GWR) Time-Domain Reflectometry (TDR) |
| Output Signals | Up to four 4–20 mA HART®-enabled analog outputs |
| Power Supply | 24 VDC loop-powered |
| Enclosure Certification | Flameproof (Ex d) and Non-incendive (Ex nA) |
| Display | Graphical LCD with 4-key keypad |
| Remote Electronics Option | Up to 30 m cable distance from probe |
| Probe Configurations | Reinforced coaxial probe or 5-rod probe |
| Compliance | IEC 61508 SIL 2 capable, ATEX, IECEx, FM, CSA certified |
| Brand | MAGNETROL |
|---|---|
| Model | Jupiter® JM4 Series |
| Type | Magnetostrictive Level Transmitter |
| Measurement Principle | Time-of-Flight (TOF) via magnetostrictive waveguide and magnetic float interaction |
| Output Signal | 4–20 mA analog (HART® or FOUNDATION Fieldbus™ optional) |
| Housing | Dual-compartment, rotatable and removable head |
| Mounting Options | Direct insertion or external mounting on MAGNETROL Orion® magnetic level indicators |
| Process Connection | Threaded (NPT, BSP) or flanged (ANSI, DIN, JIS) |
| Wetted Materials | Hastelloy® C-276 or Monel® 400 available |
| Environmental Rating | IP66/IP67, NEMA 4X |
| Certifications | ATEX, IECEx, FM, CSA for hazardous areas (Class I Div 1, Zone 1) |
| Compliance | Designed to meet requirements of FDA 21 CFR Part 11 for electronic records in regulated life science environments when integrated with validated control systems |
| Brand | MAGNETROL |
|---|---|
| Model | Modulevel® E4 |
| Type | Displacer-type Level Transmitter |
| Power Supply | Loop-powered, 2-wire |
| Measurement Principle | Buoyancy-based displacement sensing with calibrated range spring and LVDT |
| Max. Process Pressure | 348 bar (5050 psig) |
| Max. Process Temperature | 445 °C (835 °F) |
| Output Signal | 4–20 mA HART® v7.0 compliant |
| SIL Rating | IEC 61508 SIL 2 certified |
| Certifications | ATEX, IECEx, CSA, FM, NEPSI (varies by configuration) |
| Housing Material Options | Cast iron or cast aluminum |
| Enclosure Rating | IP66/IP67 |
| Remote Configuration Support | Yes, via HART® DD and DTM (PACTware™ compatible) |
| Field Replaceable Transmitter Module | Yes |
| Vibration Damping | Integrated range spring suppresses dynamic level fluctuations |
| Compliance | Designed and tested per ISA-84.01 / IEC 61511 for safety instrumented systems |
| Brand | MAGNETROL |
|---|---|
| Model | Pulsar® R80 |
| Measurement Principle | Frequency-Modulated Continuous Wave (FMCW) Radar |
| Operating Frequency | 80 GHz |
| Beam Angle | <3° |
| Maximum Process Pressure | 70 bar (1000 psi) |
| Maximum Process Temperature | 200 °C (400 °F) |
| Output Signal | 4–20 mA HART |
| Enclosure Rating | IP66/IP67, NEMA 4X |
| Antenna Options | Stainless steel horn antennas with optional PTFE or ceramic coating |
| Display | Optional integrated LCD graphic display |
| Communication | HART 7, Foundation Fieldbus (optional) |
| Diagnostics | Advanced onboard diagnostics with echo curve analysis, false echo suppression, and predictive health monitoring |
| Certifications | ATEX, IECEx, FM, CSA, SIL2 per IEC 61508 |
| Brand | MAGNETROL |
|---|---|
| Model | Pulsar® R86 |
| Measurement Principle | Time-of-Flight Pulse Radar |
| Operating Frequency | 26 GHz |
| Beam Angle | ≤8° |
| Process Pressure Range | Full Vacuum to 16 MPa (2320 psi) |
| Process Temperature Range | –70°C to +400°C (–100°F to +752°F) |
| Output Signal | 4–20 mA HART® or Foundation Fieldbus™ |
| Display Option | Integrated LCD with Echo Curve Visualization |
| Antenna Options | Stainless Steel, Coated (e.g., PTFE, FEP), All-Plastic, Extended Neck Configurations |
| Enclosure Rating | IP66/IP67, NEMA 4X |
| Certifications | ATEX, IECEx, FM, CSA, SIL2 (per IEC 61508), FDA-compliant materials available |
| Diagnostic Capability | Advanced echo analysis, false echo suppression, signal strength monitoring, health status alerts |
| Mounting | Threaded (NPT, G, BSPP), Flanged (ANSI, DIN, JIS), Quick-Disconnect Antenna Interface |
| Brand | MAGNETROL |
|---|---|
| Model | Thermatel® TA2 Series |
| Measurement Principle | Thermal Dispersion (Constant Temperature Anemometry) |
| Output Options | 4–20 mA analog + HART® v7.5 or Foundation Fieldbus™ |
| Display | 2-line × 16-character LCD |
| Accuracy | ±1% of reading (typical, dependent on gas composition and calibration conditions) |
| Repeatability | ±0.5% of reading |
| Turndown Ratio | Up to 100:1 |
| Operating Temperature Range | –40 °C to +85 °C (electronics) |
| Pressure Rating | Up to 10 MPa (depending on process connection) |
| Probe Materials | 316 SS standard |
| Certifications | ATEX, IECEx, UL/cUL Class I Div 1, SIL 2 per IEC 61508 |
| Enclosure Rating | IP66/NEMA 4X |
| Process Connections | NPT, SAE, DIN, ANSI flanges (varies by model) |
| Probe Length | Standard 150 mm to 1200 mm (custom lengths available) |
| Installation | In-line or insertion type |