Industrial Process Control Instruments
Filter
Showing 811–840 of 1088 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ProRGA-7000 |
| Pricing | Available upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Protec® P3000 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Protec® P3000XL |
| Pricing | Available Upon Request |
| Brand | PSC |
|---|---|
| Origin | USA |
| Model | MCT 460, MCT 466-SF, MCT 469-SF |
| Cooling Options | Air-cooled and water-cooled |
| Detector | Thermoelectrically temperature-stabilized MCT (Mercury Cadmium Telluride) |
| Operating Ambient Temperature | Up to 80 °C with optional cooling kit |
| Compliance | Designed for industrial environments per IEC 60529 (IP65/IP66 enclosures available) |
| Communication Protocols | PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP, DeviceNet, OPC UA over Ethernet |
| Brand | PSS (Particle Sizing Systems) |
|---|---|
| Origin | USA |
| Model | A7000 Online |
| Detection Principle | Single Particle Optical Sizing (SPOS) |
| Dilution System | Integrated Automated Dilution Module |
| Sampling Mode | Timed Automatic In-Line Sampling |
| Alarm Capability | Real-Time Threshold-Based Alerting |
| Data Output | Concentration-Compensated Raw Counts & Size Distribution |
| Compliance Framework | Supports GLP/GMP Data Integrity Requirements (21 CFR Part 11 Ready via Optional Software Configuration) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC Economy Edition |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Particle Size Range | 1–150 µm |
| Number of Channels | 8 |
| Standards Supported | NAS 1638, ISO 4406, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GOST 17216, GB/T 14039, DL/T 432, DL/T 1096, JB/T 9737, GB/T 18854 |
| Operating Pressure | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Power Supply | 9–30 VDC |
| Enclosure Rating | IP65 (industrial-grade rugged housing) |
| Brand | PULUODY |
|---|---|
| Model | OPC |
| Origin | Shaanxi, China |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Measurement Range | 1–150 µm |
| Calibration Standards Supported | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246C, GB/T 14039, DL/T 432, GJB/T 420A/B, GB/T 18854 |
| Operating Pressure | 0–0.6 MPa (standard), up to 31.5 MPa (with integrated pressure regulator) |
| Sample Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | 4–20 mA analog, RS232 serial, optional alarm relay |
| Power Supply | 9–30 VDC |
| Compliance | Designed for industrial process monitoring per ISO 21501-4, ASTM D6786, and IEC 61508 SIL2-ready architecture |
| Enclosure Rating | IP65 (standard), optional IP67 |
| Software | Integrated firmware with configurable reporting (particles/mL + contamination code) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | OPC-1 |
| Price | USD 8,200 (FOB) |
| Detection Principle | Light Blockage (Optical Obscuration) |
| Measurement Range | 1–150 µm |
| Calibration Standard Compliance | ISO 11171:2016, ISO 4402:1991 (Annex A), NAS 1638, ISO 4406:2021, SAE AS4059F, MIL-STD-1246C, GB/T 18854–2015 |
| Operating Pressure | 0–0.6 MPa (standard), up to 31.5 MPa (with integrated pressure regulator) |
| Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | 4–20 mA analog, RS232 serial, optional relay alarm |
| Power Supply | 9–30 VDC |
| Enclosure Rating | IP65 |
| Regulatory Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (via software audit trail) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-2300 |
| Price | USD 13,800 (FOB) |
| Detection Principle | Light Obscuration (LO) |
| Sensor Type | 7th-Generation Dual-Laser Narrow-Beam Optical Sensor |
| Measurement Range Options | 0.1–1.0 µm (H), 0.2–2.0 µm (I), 0.5–50.0 µm (J), 1–150 µm (B), 2–100 µm (A), 2–750 µm (K), 40–1000 µm (L), 50–1000 µm (N), 100–2000 µm (M) |
| Customizable Sizing Ranges | 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm, or fully user-defined |
| Output Interfaces | RS-232, 4–20 mA analog signal |
| Display | Integrated LCD with membrane keypad |
| Enclosure Rating | IP65 industrial housing |
| Operating Pressure | Up to 10 bar |
| Temperature Range | 0–60 °C |
| Compliance | Supports ASTM D6786, ISO 4406, ISO 11171, ISO 11943, USP <788>, and customizable regulatory logic per client specification |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-2300A |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology (7th Generation) |
| Sensor Options | A (2–100 µm), B (1–150 µm), C (1–450 µm), H (0.1–1.0 µm), I (0.2–2.0 µm), J (0.5–50.0 µm), K (2–750 µm / 2–800 µm / 5–1000 µm), L (40–1000 µm / 10–2000 µm), N (50–1000 µm), M (100–2000 µm) |
| Sizing Range (Standard) | 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm |
| Channel Resolution | 0.1 µm |
| Resolution | 10% (per ISO 21501-4) |
| Accuracy | < ±3% typical (NIST-traceable latex standard calibration) |
| Coincidence Error | ≤5% at 999,999 particles/mL |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h (programmable) |
| Calibration Standards | NIST-traceable polystyrene latex (PSL) spheres, AC fine test dust, MTD (Medium Test Dust) |
| Operating Pressure | 0–0.6 MPa (standard) |
| Flow Rate | 6–500 mL/min |
| Output Interfaces | RS-232, 4–20 mA analog, optional Ethernet/Modbus TCP |
| Display | Integrated LCD with membrane keypad |
| Environmental Rating | IP65 enclosure |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | OPC-2300D |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Sensor Options | A (2–100 µm), B (1–150 µm), C (1–450 µm), H (0.1–1.0 µm), I (0.2–2.0 µm), J (0.5–50.0 µm), K (2–750 µm / 2–800 µm / 5–1000 µm), L (40–1000 µm / 10–2000 µm), N (50–1000 µm), M (100–2000 µm) |
| Sizing Range (Configurable) | 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm |
| Channel Resolution | Up to 1000 user-selectable channels (e.g., 8/16/32 bins) |
| Resolution | 0.1 µm |
| Counting Accuracy | < ±3% typical |
| Coincidence Error | ≤5% at 999,999 particles/mL |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h |
| Calibration Standards | NIST-traceable latex spheres, AC fine test dust, or MTD |
| Operating Pressure | 0–0.6 MPa (standard) |
| Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Interface Options | Customizable compression fittings or flanged connections |
| Output Signals | RS-232 serial, 4–20 mA analog, optional Ethernet/Modbus TCP |
| Display | Integrated LCD with membrane keypad |
| Enclosure Rating | IP65 (standard), optional IP67 for harsh environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | OPC-2300F |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Optical Sensing |
| Sensor Options | A (2–100 µm), B (1–150 µm), C (1–450 µm), H (0.1–1.0 µm), I (0.2–2.0 µm), J (0.5–50.0 µm), K (2–750 µm / 2–800 µm / 5–1000 µm), L (40–1000 µm / 10–2000 µm), N (50–1000 µm), M (100–2000 µm) |
| Sizing Range | 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm (customizable) |
| Channel Resolution | 1000-channel arbitrary binning (e.g., 8/16/32 bins) |
| Resolution | 0.1 µm |
| Counting Accuracy | < ±3% typical |
| Coincidence Error | ≤5% |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h |
| Calibration Standards | NIST-traceable latex spheres, AC fine test dust, MTD |
| Operating Pressure | 0–0.6 MPa (standard) |
| Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Output Interfaces | RS-232, 4–20 mA analog, optional Ethernet/Modbus TCP |
| Housing | IP65-rated stainless steel or industrial-grade polymer |
| Compliance | Supports ISO 4406, ISO 11171, ASTM D6786, USP <788>, EP 2.9.19, and custom regulatory logic per client requirement |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-5 |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GB/T 14039, DL/T 432, GOST 17216 |
| Pressure Rating | 0–1.0 MPa (direct), 0–31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature | −10 to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V |
| Power Supply | 9–30 VDC |
| Enclosure Rating | IP65 |
| Calibration Support | NIST-traceable reference calibration available annually |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-6 |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GB/T 14039, DL/T 432, GOST 17216 |
| Max. Operating Pressure | 31.5 MPa (with pressure regulator) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB Grade Code |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-7 |
| Price | USD 8,100 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246D, GJB 420B, GB/T 14039, GOST 17216 |
| Pressure Rating | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB contamination code |
| Calibration Support | NIST-traceable reference materials, annual recalibration assistance provided |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-EX-1 |
| Price | USD 27,800 (approx.) |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Technology (7th Generation) |
| Particle Size Range | 1–150 µm |
| Calibration Standards Supported | ISO 4406, NAS 1638, GJB 420B, GOST 17216, SAE AS4059, ISO 11171, MIL-STD-1246, IP 564/565, GB/T 14039, DL/T 432, JB/T 9737, GB/T 18854 |
| Operating Pressure | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Enclosure Rating | IP40 to IP65 |
| Explosion Protection | Intrinsic Safety (Ex ia IIC T4 Ga) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB contamination grade |
| Channel Configuration | Fixed 8-channel or 16-channel (customizable) |
| Accuracy Class | ±0.6 per ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-VI |
| Price | USD 40,200 (FOB) |
| Core Principle | Light-Blocking (Obscuration) Particle Counting |
| Compliance Standards | ISO 11171:1999, ISO 4406:2023, NAS 1638, GB/T 18854–2002, GB/T 14039, MIL-STD-1246C, GJB 420B, DL/T 432 |
| Detection Channels | User-Configurable, up to 24 size thresholds (e.g., ≥4 µm(c), ≥6 µm(c), ≥14 µm(c), ≥21 µm(c), ≥38 µm(c), ≥70 µm(c)) |
| Output Signal | 4–20 mA analog per sensor channel |
| Communication Interface | RS232, optional RS485/Modbus RTU |
| Operating Temperature | –20 °C to +70 °C |
| Fluid Compatibility | Mineral oils, synthetic lubricants, phosphate ester hydraulic fluids, aviation fuels, transformer oil, turbine oil, gear oil, hydraulic fluid (water-glycol & water-oil emulsions), ultra-pure water, aggressive solvents (pH 2–12) |
| Sensor Modules | Particulate (light-blocking), ferrous/non-ferrous wear debris (inductive), water activity (capacitive), viscosity (oscillating piston), density (vibrating U-tube), dielectric constant, pressure, flow rate, temperature |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203-3 |
| Price | USD 27,800 (approx.) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Calibration Standards | JJG 1061, ISO 11171, ASTM F658-87 (PSL), GB/T 18854 |
| Detection Principle | Light Obscuration (LO) |
| Laser Source | 7th-generation dual-laser narrow-beam sensor |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 resolution channels |
| Sensitivity | 1 µm (ISO 4402) / 4 µm(c) (ISO 11171, GB/T 18854) |
| Accuracy | < ±3% |
| Sample Volume Precision | ±1% |
| Max. Online Pressure | 31.5 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Flow Rate | Sampling 5–60 mL/min |
| Operating Temp. | Sample 20–65°C |
| Power | 220 VAC, 50 Hz, <80 W |
| Data Storage | Up to 6000 test records |
| Output Interfaces | RS232, RS485, USB, 4–20 mA, 0–5 V, MODBUS |
| Regulatory Certification | CALIBRATED by NW National Metrology Center (civil) or CMC Level-1 Particle Metrology Station (defense) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601XJ |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Electromagnetic Flow Regulation |
| Measurement Range | 1–450 µm (customizable sub-ranges: 1–100 µm or 4–70 µm(c) |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP/ISO 21501) |
| Channel Count | 1000 user-definable size channels (e.g., 4/8/16/32/64/128/128+ bins) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Accuracy | ±2.5% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Compliance | FDA 21 CFR Part 11, ASTM D6786, ISO 21501-4, ISO 11171, USP <788>, <789>, <797>, EP 10.0, ChP 0903, GB/T 11446.9-2013, YBB00272004-2015, GB 8368, ISO 4406, NAS 1638, MIL-STD-1246C, JIS B 9933 |
| Software | V8.9 Analytical Suite (PC + embedded touchscreen), 5-level role-based access control, full audit trail, electronic signature, data backup/recovery, power-fail protection |
| Calibration Standards | NIST-traceable latex spheres, ISO 21501-4 reference materials, JJG 1061 certified |
| Metrology Support | National Northwest Metrology & Testing Center (CNAS-accredited), Defense Science & Technology Commission Level-1 Particle Metrology Station No. 116 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-3 |
| Price | USD 31,800 (FOB) |
| Detection Principle | Light Obscuration (LO) per ISO 11500 & ASTM F312-22 |
| Laser Sensor | 7th-generation dual-laser narrow-beam photodetector |
| Calibration Standards | ISO 4402 (ACFTD), ISO 11171 (MTD), GB/T 18854 |
| Measuring Range | 0.03 µm to 3000 µm (with selectable channels: 2–100 µm or 4–70 µm(c)) |
| Accuracy | <3% typical |
| Channel Count | 1000 configurable size bins |
| Sample Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Operating Pressure (Online) | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Fluid Temperature | 0–80 °C |
| Ambient Temperature | −15–50 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C, ISO 11171, ISO 11500 |
| Software | P6.4 Analytical Testing Suite (Integrated Industrial PC & Standalone PC Edition) |
| Interface | RS232 / RS485-to-USB / Native USB |
| Output | 4–20 mA analog +超标 alarm relay (customizable) |
| Display | Color LCD touchscreen |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-8 |
| Price | USD 31,500 (FOB) |
| Detection Principle | Light Obscuration (7th-Generation Dual-Laser Narrow-Beam Sensor) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 0.03 µm – 3000 µm (with configurable channels: 2–100 µm or 4–70 µm(c)) |
| Channel Count | 1000 adjustable size bins |
| Accuracy | <3% typical |
| Sample Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Operating Pressure (Online) | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Temperature Range | Fluid 0–80 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059D, DL/T 432, GB/T 14039, GJB 420B, MIL-STD-1246C |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Interface | RS232 / RS485-to-USB / native USB |
| Output | 4–20 mA analog +超标 alarm (customizable) |
| Display | Color TFT touchscreen (integrated industrial PC or external IPC option) |
| Key | Origin: Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QXT-3000 |
| Pricing | Available Upon Request |
| Sensor Core | ADEV 8866TR Explosion-Proof Thermal Conductivity Analyzer |
| Measurement Principle | Dual-Chamber Thermal Conductivity Differential Detection |
| H₂-in-Air Range | 85–100% vol |
| H₂-in-CO₂ Range | 0–100% vol |
| CO₂-in-Air Range | 0–100% vol |
| Accuracy | ±1% FS |
| Repeatability | ≤0.3% FS |
| Linearity Error | ≤1% FS |
| Response Time (t₆₀) | H₂ <13 s, CO₂ <23 s |
| Response Time (t₉₀) | H₂ <24 s, CO₂ <45 s |
| Zero Drift | ≤1% FS/week |
| Sample Flow Rate | 100 mL/min – 2 L/min |
| Sample Inlet | 1/4" or 6 mm compression fitting |
| Analog Outputs | Four isolated 4–20 mA channels |
| Digital Interface | RS232 / RS485 |
| Power Supply | Sensor: 24–30 VDC |
| Transmitter | 115 VAC ±10% or 220 VAC ±20%, 50 ±0.5 Hz, 150 VA |
| Enclosure Rating | IP66 |
| Explosion Protection | ATEX 94/9/EC (EN 60079-0, -1), IECEx, CSA Class I, Div 1, Groups B, C, D, T6 |
| Hazardous Area Classification | Zone 1 / Zone 2 |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RTK BRE |
| Pricing | Available Upon Request |
| Measurement Modes | Aerobic Oxygen Uptake Rate (OUR) & Anaerobic Gas Production Rate |
| Channel Capacity | Scalable Multi-Channel (8 channels × N modules) |
| Software-Controlled Autonomous Operation | Up to 6 months continuous unattended operation |
| Aerobic Measurement Precision | ±0.05 mg O₂ |
| Anaerobic Measurement Precision | ±0.03 mL gas |
| Data Logging Intervals | Configurable from 1 minute to 24 hours |
| Compliant Standards | OECD 301C, 301F, 302C, 209, 224, 311 |
| Application Flexibility | Liquid-phase (aqueous), solid-phase (compost/soil), and slurry-based biodegradation assays |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK CRM-18 |
| Pricing | Available Upon Request |
| Gas Measurement Principle | Gravimetric Micro-Calorimetric (GMC) Technology |
| Channels | 18 parallel reactors |
| Reactor Volume | 500 mL |
| Reactor Material | Borosilicate Glass |
| Stirring Options | Magnetic or Mechanical |
| CO₂ Absorption | Integrated or External 3 mol/L NaOH/KOH with pH indicator |
| Measurement Accuracy | ±1.0 mL per channel |
| Temperature & Pressure Compensation | Yes (converted to STP: 273.15 K, 101.325 kPa) |
| N₂ Compensation Function | Yes |
| Data Logging | Embedded Web Server with Auto-Save & Resume on Power Recovery |
| Compliance Standards | ASTM D5988-18, ISO 14851-2019, ISO 23977-2-2020, ISO 17556-2019, ISO 14853-2016, ISO 15985-2014, GB/T 40611-2021, GB/T 19276.1-2003, OECD 311, OECD 301C/F |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RTK MFC-12V/24V |
| Pricing | Upon Request |
| Channels | 12 or 24 |
| Voltage Range | 0–1 V |
| Voltage Resolution | 0.001 V |
| Brand | Rocktek |
|---|---|
| Model | RTK PBDA-300C |
| Origin | Hubei, China |
| Control Channels | 12 or 24 (expandable in increments of 12) |
| Temperature Range | Ambient +5 °C to 70 °C |
| Temp. Stability | ±2 °C |
| CO₂ Detection | 0–10,000 ppm (NDIR) |
| Accuracy | ±100 ppm (0–2000 ppm), ±500 ppm (>2000 ppm) |
| O₂ Detection | 0–25% vol (electrochemical) |
| Resolution | 0.1% vol |
| Mass Flow Controllers | 13 units |
| Range | 0–200 mL/min |
| Accuracy | ±0.3% FS (≤30% FS), ±1.0% FS (>30% FS) |
| Vessel Capacity | >3 L per stainless-steel reactor |
| Dimensions (12-channel) | 960 × 790 × 1050 mm |
| Dimensions (24-channel) | 960 × 1580 × 1050 mm |
| Compliance | EN 13432, ISO 14855-1, GB/T 19277.1 |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK-207 |
| Pricing | Upon Request |
| Temperature Range | 20–40 °C (Uniformity ≤ ±1 °C) |
| Illuminance | ≥10,000 lux |
| Humidity Range | 50–95% RH (Stability ≤ ±3% RH) |
| Chamber Volume | ≥150 L |
| Power Supply | 220 V, 50 Hz, Max. 750 W |
| Dimensions (W×D×H) | 600 × 650 × 1410 mm |
| Weight | 120 kg |
| Refrigeration | Hermetic Compressor with Modular Design, Delayed Start & Dual Pressure Protection |
| Interior | Stainless Steel with Adjustable Shelves |
| Air Circulation | Forced Convection via Stainless Steel Duct System |
| Control Interface | Touchscreen Display with Data Export Capability |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK-BMP |
| Price | Upon Request |
| Application Domain | Environmental Engineering (Wastewater Treatment, Activated Sludge Assessment) |
| Digestion Reactors | 18 × 500 mL (optional 1000 mL / 2000 mL, borosilicate glass) |
| Temperature Control | 25–99.9 °C (±0.15 °C), water bath, 2 kW heating, 25 L internal volume |
| Stirring | Brushless motor, 0–200 rpm, software-programmable speed & interval |
| CO₂ Absorption | 18 × 100 mL bottles, >98% efficiency with 3 M NaOH + pH indicator (optional) |
| Gas Measurement Principle | GMC Ultra-Micro Gas Measurement Technology |
| Gas Volume Resolution | 1.0 mL per channel |
| Standardization | Real-time correction to STP (273.15 K, 101.325 kPa) using integrated temperature & pressure sensors |
| Nitrogen Compensation | Automatic headspace and N₂-purge offset correction |
| Data Acquisition | ARM® Cortex™-based multi-core industrial controller, FPGA-accelerated I/O, web-based server architecture |
| Power Backup | Built-in UPS support for data retention during grid failure |
| User Access | Multi-user concurrent login with isolated experiment workspaces |
| Remote Access | Browser-based interface compatible with Windows, macOS, iOS, and Android over LAN |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hyscan II |
| Price | Upon Request |
| Dimensions (W×D×H) | 600 mm × 600 mm × 1000 mm |
| Weight | 120 kg |
| Power Supply | 220 V / 50 Hz, armored 5-m power cable |
| Sample Mass | 100 g |
| Analysis Time | < 5 minutes |
| Measurement Range | 0.01–1.99 cm³/100 g |
| Sensitivity | 0.01 cm³/100 g |
| Accuracy | ±5% (vs. vacuum fusion reference method) |
| Certification | LMFA (Light Metals Federation of Australia) Manufacturing License |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YLG-1 |
| Quotation | Upon Request |
| Startup Time | ~20 min |
| Cooling Power | 200 W at 25°C |
| Outlet Dew Point | +3°C |
| Dew Point Stability | ±0.5 K |
| Dimensions (W×D×H) | 235 × 375 × 310 mm |
| Power Supply | AC 220 V, 50 Hz |
| Sample Gas Inlet/Outlet Connection | 6 mm OD × 1 mm wall tubing |
| Condensate Drain Connection | 4 mm OD × 1 mm wall tubing |
