Industry-specific Instruments
Filter
Showing 301–330 of 2165 results
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | C100 |
| Product Type | Online Instrument |
| Detection Target | Mechanical Contaminants |
| Particle Recognition Capability | ≥4 µm |
| Compliance Support | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic oil, lubricating oil, fuel, mineral oil, synthetic oil, coolant, cleaning solution, cutting fluid |
| AI Engine | Trained on >500 commercial lubricant models and ferrographic particle morphology database |
| Data Output | Wired (Ethernet gateway) or Wireless (Wi-Fi/LoRaWAN) |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | C120 |
| Type | Online Instrument |
| Detection Target | Mechanical Contaminants (Wear Debris) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Fuel Oil, Mineral & Synthetic Oils, Coolants, Cutting Fluids, Cleaning Solutions |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/LoRaWAN) |
| AI Engine | Trained on >500 Commercial Lubricant Models & Lab-Validated Ferrographic Image Database |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EX S100 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants |
| Compliance | ATEX/IECEx Certified for Hazardous Areas |
| Particle Detection Threshold | ≥4 µm |
| Output Standards | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic Oils, Lubricating Oils, Mineral & Synthetic Oils, Fuels, Coolants, Cutting Fluids, Aqueous Solutions |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EXC100 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants |
| Compliance | ATEX/IECEx Certified for Hazardous Areas |
| Particle Detection Threshold | ≥4 µm |
| Output Standards | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic oil, lubricating oil, fuel, mineral & synthetic oils, coolants, cleaning fluids, cutting fluids |
| Data Interface | Wired Ethernet Gateway / Wireless (Wi-Fi/LoRaWAN) |
| AI Engine | Trained on >500 commercial lubricant models and ironographic particle morphology database |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EXS120 |
| Product Type | Online Instrument |
| Detection Target | Mechanical Contaminants (Particulate Wear Debris) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ATEX/IECEx Zone 1/21 Certified |
| Measurement Principle | AI-Enhanced Digital Image Analysis of In-Stream Oil Flow |
| Data Output | ISO 4406, NAS 1638, Wear Mode Classification (Fatigue, Cutting, Pitting, etc.) |
| Fluid Compatibility | Mineral Oils, Synthetic Lubricants, Hydraulic Fluids, Fuels, Coolants, Cleaning Solutions, and Aqueous Cutting Fluids |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OiHealth PROBE |
| Product Type | Online Instrument |
| Voltage | 24 V DC |
| Current Consumption | <200 mA |
| Digital Outputs | RS485 (Modbus RTU), Ethernet RJ45 (Modbus TCP/IP, FTP, Telnet) |
| Maximum Operating Pressure | 5 bar |
| Viscosity Range | 0–460 cSt |
| Operating Temperature | −20 °C to +80 °C |
| Ingress Protection | IP65 |
| Hydraulic Connection | 1/2″ BSP |
| Certifications | CE, GL Class pending |
| Detection Principle | Optical Absorption & Scattering Spectroscopy |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilCMS |
| Product Type | Portable Instrument |
| Detection Parameters | Tribological Wear Analysis |
| Oil Compatibility | Synthetic, Mineral, Organic Oils & Diesel (up to 3000 cSt) |
| Standards Compliance | ISO 4406, SAE AS4059, NAS 1638 |
| Software | Rubolab Oil Condition Monitoring Suite |
| Operating Modes | Offline (Bottle Sampling) & Online (High-Pressure Flow Cell) |
| Data Export | CSV, PDF |
| Calibration | Auto-calibration via embedded oil database (500+ lubricants), field-updatable |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilHealth |
| Type | Online Lubricant Oxidation Sensor |
| Compliance | CE, RoHS, ATEX Zone 2 (optional), IP67-rated housing |
| Communication | 4–20 mA analog output, Modbus RTU (RS-485), optional CAN bus or Ethernet/IP integration |
| Operating Temperature | −25 °C to +120 °C |
| Pressure Rating | Up to 10 bar (static) |
| Material | 316L stainless steel wetted parts, PEEK sensor body |
| Response Time | < 30 s (t₉₀) |
| Calibration | Factory-calibrated for mineral, PAO, and ester-based lubricants |
| Lifetime | ≥ 5 years in continuous operation (MTBF > 40,000 h) |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilMoisture |
| Type | Online Instrument |
| Detection Target | Water Contamination in Lubricants |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Compliance Context | Designed for ISO 4406, ASTM D6304, and ISO 11171-compliant condition monitoring systems |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C100 |
| Pricing | Upon Request |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S100 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Online Monitoring Sensor |
| Detection Parameter | Mechanical Contaminants (Particulate Matter) |
| Particle Detection Threshold | ≥4 µm |
| Compliance Standards | ISO 4406:2017, NAS 1638 Class Code Calculation, ASTM D7647 (Image-Based Particle Analysis), GLP-Traceable Data Logging |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | S100 |
| Particle Detection Threshold | ≥4 µm |
| Output Standards | ISO 4406, NAS 1638, SAE AS4059 |
| Classification Capability | Wear Debris Typing (Fatigue, Sliding, Cutting >20 µm) |
| Communication Interfaces | Analog (4–20 mA), Digital (RS-485, Modbus RTU), SCADA/PLC Compatible |
| Integration | Modular design for OEM integration into oil condition monitoring systems |
| Compliance | Designed for industrial fluid monitoring per ISO 11171 (calibration reference), ISO 4020 (hydraulic fluid sampling), and aligned with ASTM D6786 (particle counting in lubricants) |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S120 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants (Particulate Matter) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/4G) |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Fuel Oil, Mineral Oil, Synthetic Oil, Coolants, Cleaning Solutions, Cutting Fluids |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Product Type | Online Instrument |
| Detection Parameters | Mechanical Contaminants (Particulate Matter) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Mineral Oil, Synthetic Oil, Fuel Oil, Coolants, Cutting Fluids, Cleaning Solutions |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/4G) |
| AI Engine | Trained on >500 Commercial Lubricant Models & Iron Spectroscopy Image Database |
| Software | Cloud-Enabled Diagnostic Platform with Audit Trail & GLP/GMP-Ready Reporting |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilWear S120 |
| Product Type | Online Instrument |
| Detection Target | Solid Contaminants & Degradation Indicators |
| Particle Size Range | ≥4 µm |
| Source Discrimination Capability | ≥20 µm (size + shape-based classification) |
| Compliance Standards | ISO 4406, SAE AS4059, NAS 1638 |
| Communication Interfaces | Analog (4–20 mA), Digital (RS-485, Modbus RTU), PLC/SCADA/PC Compatible |
| Self-Calibration & Diagnostics | Yes |
| Configurable Alarm Thresholds | Yes |
| Integrated Oil Health Monitoring | Compatible with Atten2 OilHealth Platform |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Atten2 SMK Smart Oil Filtration Kit |
| Product Type | Online Monitoring Instrument |
| Measured Parameters | Particle Contamination, Air Bubble Content, Foam Inhibitor Condition, Optional Water Content |
| Compliance Standards | ISO 4406:2017, SAE AS4059F, NAS 1638 Class |
| Power Supply | 24 V DC, <250 mA |
| Particle & Bubble Count Output | ISO Code, p/mL, b/mL |
| Volumetric Flow Visualization | L/min |
| Optional Humidity Sensor (Water-in-Oil) | ppm |
| Digital Interface | Local Display + Ethernet RJ45 (IP, FTP, Telnet) |
| Max Operating Pressure | 20 bar |
| Operating Temperature Range | 0–80 °C |
| Kinematic Viscosity Range | 0–540 cSt |
| Counting Accuracy | ±1 ISO Code |
| Enclosure Rating | IP65 |
| Brand | NORMALAB |
|---|---|
| Origin | France |
| Model | NAE 440 |
| Temperature Range | –10 to 150 °C |
| Standard Compliance | ASTM D611, IP 2, NF M 07-021, ISO 2977, GB/T 262 |
| Heating Method | Metal Bath |
| Safety Features | Integrated Thermal and Overheat Protection |
| Configuration | Dual-Sample Position |
| Connectivity | RS-232/USB Interface for PC Integration |
| Software | Dedicated Aniline Point Management Suite with Audit Trail & Data Export (CSV, PDF) |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AutoREID- |
| Price | Upon Request |
| Standard Compliance | ASTM D323-B, ASTM D4953, ISO 3007, GB/T 8017-87 |
| Pressure Range | 0–250 kPa |
| Resolution | 0.1 kPa |
| Test Duration | <15 min per sample |
| Display | 8-inch color touchscreen |
| Languages | English, French, Russian |
| Data Storage | Internal database, USB 2.0 (2×), Ethernet (LAN) |
| Dimensions (W×D×H) | 720 × 440 × 460 mm |
| Weight | 30 kg |
| Power Supply | 230 V, 8 A, 50 Hz |
| Brand | AUTOSCAN |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Autoscan-1 |
| Pricing | Upon Request |
| Brand | AUTOSCAN |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Autoscan-6 |
| Pricing | Available Upon Request |
| Brand | AUTOSCAN |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Autoscan |
| Pricing | Upon Request |
| Brand | AUTOSCAN |
|---|---|
| Origin | Australia |
| Model | Autoscan-3 |
| Application | Apatite & Zircon Fission Track Thermochronology |
| Measurement Principle | Neutron Irradiation + Automated Microscopic Track Imaging & Length Distribution Analysis |
| Optical System | High-NA EC Plan Apochromat Objectives with Anti-Fungal Coating |
| Compliance | ASTM D7612, ISO/IEC 17025 (for lab-accredited dating workflows), GLP-aligned data audit trail capability |
| Software | Integrated track detection, length measurement, histogram generation, and thermal history inversion (using QTQt or HeFTy-compatible output formats) |
| Number of dissolution vessels | 7 |
|---|---|
| Rotational speed range | 25–250 rpm |
| Speed resolution | 1 rpm |
| Speed accuracy | ±2% |
| Water bath temperature range | Ambient +5°C to 60°C |
| Temperature control accuracy | ±0.1°C |
| Maximum cumulative timing | 99 h 59 min |
| Number of programmable sampling intervals | 10 |
| Maximum interval duration | 9 h 59 min |
| Auto power-on/off timer range | 99 h 59 min |
| Power consumption | 1300 W |
| Input voltage | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 670 × 470 × 420 mm |
| Net weight | ~42 kg |
| Brand | Avisoft |
|---|---|
| Origin | Germany |
| Model | SASLab Pro |
| Operating System | Windows (Vista/7/8/10) |
| License Type | Commercial Desktop Software |
| Compliance | ISO/IEC 17025-aligned workflow support, GLP-ready metadata handling, FDA 21 CFR Part 11–compatible audit trail (via optional configuration) |
| Brand | AWT |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Equipment |
| Model | 2800 Series |
| Pricing | Available Upon Request |
| Brand | AWT |
|---|---|
| Origin | United Kingdom |
| Model | 3000 Series |
| Compliance | EN 54-7, EN 54-5, EN 14604, BS 5446-2, GB 4715-2024, GB 4716-2024 |
| Configuration Options | 3100 (optical smoke only), 3400 (optical smoke + thermal verification), 3800 (optical smoke + thermal verification + refrigerated aerosol generation) |
| Brand | Axel Semrau |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Chronect |
| Pricing | Upon Request |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Housing | TO-39 metal can |
| Spectral Range | 2–16 µm |
| Emissivity | >0.95 (blackbody-like) |
| Modulation Speed | Up to 100 Hz (electrical, chopper-free) |
| Power Consumption | <150 mW (typ.) |
| Lifetime | >50,000 h (at rated operating conditions) |
| MEMS Qualification | IEC 60749-21 / IEC 61340-5-1 / IEC 60068-2 series compliant |
| Optional Windows | Sapphire, CaF₂, BaF₂, Ge |
| Mounting | Standard TO-39 footprint with solderable leads |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Model | LGD Compact-A CH4/C2H6 |
| Measurement Range | 0–100 ppm / 4% CH₄ & 0–1000 ppm C₂H₆ |
| Resolution | ±0.8 ppm (CH₄, low range) & ±15 ppm (C₂H₆) |
| Minimum Detectable Range | 0–100 ppm CH₄ & 0–1000 ppm C₂H₆ |
| Response Time (T90) | <2 s |
| Operating Principle | Tunable Diode Laser Spectroscopy (TDLS) |
| Product Type | Biogas & Natural Gas Analysis Module |
| Compliance | CE, RoHS, REACH |
| Integration Form Factor | OEM-ready compact module (PCB-mountable, 32 × 32 × 12 mm) |
| Brand | AYALYTICAL |
|---|---|
| Origin | USA |
| Model | FoamDDI |
| Detection Type | Total Sulfur Analysis |
| Portability | Portable |
| Standards Compliance | ASTM D892, D6082, D1881 |
| Temperature Range | 20–100 °C |
| Display | 10.1″ projected capacitive touchscreen |
| Power | Auto-ranging 90–264 VAC, 47–63 Hz, 280 W |
| Dimensions (W×D×H) | 350 × 300 × 270 mm |
| Weight | 10 kg |
| Storage | 64 GB SSD |
| Interface | Dual Ethernet, USB 3.0 ×1, USB 2.0 ×4, HDMI, VGA, USB printer/mouse/keyboard support |
| Humidity Tolerance | ≤75% non-condensing |
| Measurement Accuracy | ±0.25% of raw reading |
| Imaging Method | Patented digital video detection with real-time height quantification |
| Test Modes | Program I, II, III, IV |
| Output | Foam volume (mL), time-stamped video, dynamic/static foam height profiles |
