| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Packaged Beer Measurement System |
| Instrument Type | Dedicated Beer Analyzer |
| Application | Laboratory-Based Quality Control |
| Measurement Time | 3 min per sample |
| Alcohol Content Range | 0–12 % v/v |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 515 × 1200 × 1120 mm / 482 × 750 × 670 mm / 482 × 730 × 446 mm |
| Weight | 30 kg |
| Sampling Technology | Pressurized Direct Injection, No Sample Preparation Required |
| Sample Volume per Package | 260 mL |
| Throughput | 7 samples/hour or 15 samples/hour (depending on configuration) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | PMA 500 |
| Detection Method | Closed Cup Method |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + X °C to 410 °C |
| Ignition Method | Electric Spark Ignition |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest Division) |
| Type | Imported Instrument |
| Model | PetroOxy |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PMA 300 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + ~10 °C to 370 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PNR 12 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | RapidOxy 100 |
| Pricing | Available upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | RapidOxy |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TAG500 |
| Detection Method | Closed-Cup (Tagliabue) |
| Operation Mode | Fully Automatic |
| Temperature Range | −30 °C to +130 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TPO 5000 |
| Instrument Type | Beer-Specific Analyzer |
| Application Mode | Online & Laboratory |
| Measurement Time | 4 min |
| Dimensions (L × W × H) | 515 × 590 × 1120 mm |
| Weight | 70 kg |
| [Brand | ANTSCI |
|---|---|
| Origin | Italy |
| Model | Skin-SP |
| Probe Count | 6 external + 1 integrated sebum sensor |
| Moisture Range | 0–100 u.c., ±5% |
| Sebum Range | 0–100 u.c., ±5% |
| pH Range | 2–12, ±1% |
| Melanin Range | 0–100, ±5% |
| Elasticity Range | 0–50, ±5% |
| Temperature Range | 20–40 °C, ±0.1 °C |
| Measurement Time | 4–10 s |
| Display | 7″ color LCD touch screen |
| Printer | thermal, 34-column report output |
| Power | 12 V DC / 3.5 A, max. 60 W |
| Dimensions | 450 × 260 × 120 mm |
| Weight | 2.8 kg |
| Compliance | CE] |
| Brand | AOM Systems |
|---|---|
| Origin | Germany |
| Model | SpraySpy LabLine / SpraySpy ProcessLine |
| Measurement Principle | Laser-based Time-of-Flight Droplet Sizing & Velocimetry |
| Output Parameters | Droplet Diameter (µm), Velocity (m/s), Number Density (1/cm³), Transparency Classification, Volumetric Flow Density (mL/min·cm²), Momentum (kg·m/s) |
| Environmental Rating | ATEX Zone 1/21 Certified |
| Data Compliance | FDA 21 CFR Part 11 Ready (Audit Trail & Electronic Signature Optional) |
| Software Platform | SprayAI v4.2 (Real-time AI Analytics Engine) |
| Integration Interface | EtherCAT, PROFINET, OPC UA, RESTful API |
| Brand | ANPRO |
|---|---|
| Origin | Sichuan, China |
| Manufacturer | ANPRO Biotechnology Co., Ltd. |
| Type | Domestic |
| Model | APN-P |
| Price | USD 8,300 (approx.) |
| Detection Principle | Colloidal Gold Immunochromatographic Assay (Quantitative Lateral Flow) |
| Detection Target | Lead (Pb) in Edible Oils |
| LOD | 0.02 ppm |
| Quantitative Range | 0–1 ppm |
| Display | Color Resistive Touchscreen |
| Data Output | Built-in Thermal Printer |
| Test Card Storage | Ambient Temperature (15–30 °C) |
| Regulatory Alignment | Compliant with GB 2762–2022 (National Food Contaminant Limits), aligned with ISO/IEC 17025 validation practices for rapid screening methods |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | DLI400, DLI500, DLI600 |
| Measurement Wavelength Range | 400–700 nm (DLI400), 389–692 nm (DLI500), 383–757 nm (DLI600) |
| Measurement Range | 0–4000 µmol/m²/s |
| Resolution | 1 µmol/m²/s (real-time), 0.1 µmol/m²/s (stored PPFD), 0.1 mol/m²/day (DLI), 0.1 h (photoperiod) |
| Calibration Uncertainty | ±5% |
| Long-term Drift | <2%/year |
| Cosine Response Error | ±5% up to 75° zenith angle |
| Field of View | 180° |
| Response Time | 2.5 s |
| Data Logging Capacity | 99 days (DLI & photoperiod), 10 days (30-min averaged PPFD/ePPFD) |
| Operating Temperature | –40 to +70 °C (DLI500/DLI600), –10 to +60 °C (DLI400) |
| IP Rating | IP65 |
| Weight | 67 g |
| Power | Two AAA batteries (≈6 months life) |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | MC-100 |
| Measurement Unit | µmol chlorophyll m⁻² |
| Sampling Area | 63.6 mm² (9.0 mm diameter) / 19.6 mm² (5.0 mm reduced diameter) |
| Resolution | ±10 µmol m⁻² |
| Linearity | ±1% |
| Repeatability | ±1% |
| Sampling Time | 3 s |
| Memory Capacity | 94,000 measurements (8 MB internal) + 160,000 GPS-tagged records |
| Display | 125 × 37.5 px monochrome LCD |
| Interface | USB + RS-232 (GPS-integrated) |
| Operating Temperature | 0–50 °C with full-range thermal compensation |
| Power | 9 V DC alkaline battery |
| Dimensions | 152 × 82 × 25 mm |
| Warranty | 1-year limited warranty, lifetime technical support |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | MQ500 |
| Measurement Uncertainty | ±5% |
| Measurement Range | 0–4000 µmol·m⁻²·s⁻¹ |
| Long-term Drift | <2% per year |
| Repeatability | <0.5% |
| Nonlinearity | <1% |
| Response Time | <1 ms |
| Field of View | 180° |
| Spectral Range | 389–692 nm ±5 nm |
| Spectral Selectivity | <10% (412–692 nm ±5 nm) |
| Azimuthal Error | <0.5% |
| Tilt Error | <0.5% |
| Temperature Response | −0.11±0.04 %·°C⁻¹ |
| Ingress Protection Rating | IP68 |
| Dimensions | 24 mm (diameter) × 37 mm (height) |
| Mass | 100 g (including 5 m cable) |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SK01-DP2 |
| Spectral Range | 400–700 nm |
| Output Sensitivity | 0.5 mV per μmol·s⁻¹·m⁻² |
| Measurement Range | 0–3000 μmol·s⁻¹·m⁻² |
| Response Time (95%) | 30 ms |
| Long-Term Drift (per year) | < ±2% |
| Nonlinearity | < ±1% |
| Directional Response (30°–80° zenith angle) | < ±30 W·m⁻² (ISO 9060 Class II compliant) |
| Temperature Response | < ±0.15% per °C |
| Operating Temperature | −35 to +60 °C |
| Power Supply | 5.5–14.5 VDC, 3 mA |
| Housing | Anodized aluminum, IP67 rated |
| Cable Length | 3 m |
| Weight | 0.3 kg |
| Dimensions (L×W×H) | 150 × 150 × 150 mm |
| Calibration Uncertainty | ±3% |
| Spectral Responsivity Match (vs. CIE PAR action spectrum) | ±6% (overcast) to +2% (thin cloud) |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SN-500 |
| Measurement Range | Shortwave Up: 0–2000 W/m² |
| Shortwave Down | 0–2000 W/m² |
| Longwave Up | –200 to +200 W/m² |
| Longwave Down | –200 to +200 W/m² |
| Spectral Range | Shortwave Up: 385–2105 nm |
| Shortwave Down | 295–2685 nm |
| Longwave Up/Down | 5000–30,000 nm |
| Sensitivity | 55 µV/W/m² (SW Up) |
| Response Time | <1 s (to 95%) |
| Zero Offset (5 K/h) | 18.2 W/m² (SW Up) |
| Field of View | SW Up: 180° |
| SW Down | 150° |
| LW Up/Down | 180° |
| Built-in Temperature Sensor | PT-100 Platinum RTD |
| Heater | 12 V DC |
| Cable Length | 5 m |
| Ingress Protection | IP67 |
| Output Interface | SDI-12 (4 independent channels) |
| Operating Environment | –50 °C to +80 °C, 0–100 % RH |
| Brand | METER Group, Inc. |
|---|---|
| Origin | USA |
| Model | Aqualab 4TE DUO |
| Measurement Principle | Chilled-Mirror Dew Point |
| Temperature Control | Dual-Zone Peltier (±0.1 °C) |
| Water Activity Range | 0.01–0.98 aw |
| Resolution | 0.001 aw |
| Moisture Content Accuracy | Up to 10× higher than gravimetric methods for hygroscopic matrices |
| Calibration Traceability | NIST-traceable saturated salt standards |
| Data Security | User-access levels, audit trail, password-protected settings |
| Compliance | Supports FDA 21 CFR Part 11, GLP/GMP documentation requirements |
| Sample Equilibration Time | <5 min typical |
| Power | 100–240 VAC, 50/60 Hz |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | 4TE DUO |
| Sensor Type | Mirror Condensation Dew Point Sensor |
| Accuracy (aw) | ±0.003 aw |
| Resolution (aw) | ±0.0001 aw |
| Measurement Range (aw) | 0.1000–0.9500 aw |
| Repeatability (aw) | ±0.001 aw |
| Moisture Content Resolution | ±0.01% |
| Moisture Content Repeatability | ±0.02% |
| Temperature Control Range | 15–50 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Sample Volume | 7 mL (max 15 mL) |
| Measurement Time | <5 min (avg. 2.5 min) |
| Data Storage Capacity | 8,000 readings |
| Display | 128×64 pixel backlit LCD |
| Interface | RS-232, USB |
| Dimensions | 26.7 × 17.8 × 12.7 cm |
| Weight | 3.18 kg |
| Power | 110–220 VAC, 50/60 Hz, <0.4 A |
| Operating Environment | 4–60 °C, 0–90% RH (non-condensing) |
| Certifications | CE |
| Warranty | 1 year (parts & labor) |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | Aqualab 4TE |
| Sensor Principle | Mirror Condensation Dew Point |
| Accuracy | ±0.003 aw |
| Resolution | 0.0001 aw |
| Measurement Range | 0.030–1.000 aw |
| Repeatability | ±0.001 aw |
| Temperature Control Range | 15–50 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Sample Volume | 7 mL (max 15 mL) |
| Measurement Time | <5 min (avg. 2.5 min) |
| Data Storage Capacity | 8,000 secure readings with timestamp, user ID, and calibration logs |
| User Accounts | Up to 25 configurable usernames/passwords |
| Interface | RS-232, USB |
| Display | 128×64-pixel backlit LCD |
| Dimensions | 26.7 × 17.8 × 12.7 cm |
| Weight | 3.18 kg |
| Power | 110–220 V AC, 50/60 Hz, <0.4 A |
| Operating Environment | 4–60 °C, 0–90% RH (non-condensing) |
| Certifications | CE, AOAC Official Method 975.13, FDA 21 CFR Part 11 compliant (audit trail, electronic signature support) |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Pawkit |
| Price Range | USD 1,400–7,000 (est.) |
| Sensor Type | Capacitive Hygrometric Sensor |
| Accuracy | ±0.02 aw |
| Resolution | ±0.01 aw |
| Measurement Range | 0.00–1.00 aw |
| Repeatability | ±0.01 aw (typical, per AOAC 978.17) |
| Sample Cup Volume | 7 mL (max. 15 mL) |
| Measurement Time | < 5 min |
| Display | 6-digit custom LCD (3-digit aw + 3-digit °C) |
| Dimensions | 6.6 × 10.7 × 2.0 cm |
| Weight | 115 g |
| Power Supply | Two 3 V CR2032 lithium coin cells (3-year typical service life) |
| Operating Environment | 4–60 °C |
| Certifications | CE Marked |
| Warranty | 1 year parts & labor (extendable) |
| Brand | Aqualab / METER Group |
|---|---|
| Origin | USA |
| Model | AquaLab Pre |
| Sensor Type | Mirror Condensation Dew Point (Standard), Capacitance (Optional) |
| Accuracy | ±0.01 aw (Dew Point), ±0.015 aw (Capacitance) |
| Resolution | 0.001 aw |
| Measurement Range | 0.05–1.000 aw |
| Repeatability | ≤ ±0.002 aw |
| Temperature Control | Fixed at 25.0 °C (±0.2 °C stability) |
| Temp. Resolution | 0.1 °C |
| Sample Volume | 7 mL recommended (max 15 mL) |
| Measurement Time | < 5 minutes |
| Display | 20-character alphanumeric backlit LCD |
| Interface | RS-232, USB |
| Dimensions | 24.1 × 22.9 × 8.9 cm |
| Weight | 3.2 kg |
| Power | 110–220 VAC, 50/60 Hz, < 0.4 A |
| Operating Environment | 4–60 °C, 0–90% RH (non-condensing) |
| Certifications | CE, AOAC Official Method 978.18 |
| Warranty | 1 year parts and labor |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AquaLab VSA |
| Price Range | USD 25,000 – 62,500 (converted at ~¥200,000–¥500,000) |
| Measurement Principle | Mirror Condensation Dew Point |
| Isotherm Methods | Dynamic Dew-point Isotherm (DDI) & Dynamic Vapor Sorption (DVS) |
| Accuracy | ±0.005 aw |
| Resolution | ±0.001 aw |
| aw Range | 0.030–0.950 |
| Repeatability | ±0.003 aw |
| Temperature Control | 10–60 °C (STP adjustable) |
| Temp Stability | ±0.1 °C |
| Max Operating Pressure | ≤7 psi |
| Sample Mass Range | 500–5000 mg |
| Mass Resolution | ±0.1 mg |
| Sample Cup Volume | 7.5 mL (recommended), up to 15 mL |
| Water Reservoir Volume | 7 mL (max 15 mL) |
| Display | 128×64-pixel backlit LCD |
| Dimensions | 25.4×38.1×30.5 cm |
| Enclosure | Machined aluminum frame with flame-retardant silicone resin |
| Weight | 14.97 kg |
| Power | 110–220 V AC, 50/60 Hz |
| Operating Environment | 4–60 °C, 10–90% RH (non-condensing) |
| Certifications | CE |
| Warranty | 1 year (parts & labor) |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | Aquamax KF PRO LPG |
| Application | Coulometric Karl Fischer titration for trace moisture determination in pressurized liquefied gases (LPG, LNG) and vapor-phase hydrocarbon streams |
| Detection Range | 0.1–1000 µg H₂O (equivalent to 0.1–500 ppmv in gas phase, depending on sample volume and density) |
| Sample Form | Liquid or vapor-phase, pressurized |
| Automation Level | Fully automated sample introduction, titration, rinsing, and method execution |
| Compliance | Designed per ISO 8573-3, ASTM D6304, ASTM D7429, and EN 15472 |
| Brand | AQUAREAD |
|---|---|
| Origin | Japan |
| Model | MAO-1A |
| Measurement Range | 0–12 mm |
| Resolution | 0.01 mm |
| Display | Digital LCD |
| Probe Material | Precision Alloy |
| Haugh Unit Calculation | Manual via integrated scale (based on albumen height and egg weight) |
| Compliance | Designed for ASTM E1695-08 (Standard Practice for Determination of Haugh Units), ISO 6497:2002 (Animal feeding stuffs — Sampling), and aligned with USDA Agricultural Handbook No. 75 and EU Regulation (EC) No. 589/2008 Annex IV criteria for egg classification |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-Series Tree Resistograph |
| Quotation | Available Upon Request |
| Penetration Depth | 300 mm / 400 mm |
| Penetration Speed | 10–45 cm/min |
| Spatial Resolution | 0.1 mm |
| Data Storage Capacity | 256 KB (~20 m), 512 KB (~40 m), or 1 MB (~90 m) |
| Probe Lifespan | 200–300 insertions in softwood |
| Power Supply | 7.2 V, 1.7 Ah / 2.0 Ah NiCd rechargeable battery |
| Charger Input | 110 V / 220 V AC |
| Operating Temperature | 0–50 °C |
| Brand | Rinntech |
|---|---|
| Origin | Germany |
| Product Type | Imported Industrial Forestry Instrument |
| Distribution Model | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | F1 |
| Type | Modular Educational Bench for Fluid Statics, Dynamics, and Hydraulic Machinery Experiments |
| Mobility | Freestanding, Wheeled Workbench |
| Construction | Lightweight Structural Frame with Integrated Manifolds and Quick-Connect Fluid Circuitry |
| Compliance | Designed to Support Curriculum-Aligned Laboratory Instruction per ISO/IEC 17025–aligned pedagogical validation protocols |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | F1-12 |
| Type | Educational Hydraulics Teaching Equipment |
| Application | Fundamental Hydrostatics Laboratory Experiment |
| Compliance | Designed to ASTM D4439 / ISO 10521-1 educational verification standards |