| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-818A-12 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 12 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-818A-8 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LoHand |
|---|---|
| Model | LH-B50 |
| Origin | Zhejiang, China |
| Instrument Type | Milk Cryoscope (Freezing Point Depression Analyzer) |
| Measurement Principle | Thermistor-based freezing point depression detection |
| Sample Volume | ~1.0–1.5 mL |
| Resolution | 0.001 °C |
| Repeatability | ±0.002 °C |
| Operating Temperature Range | 10–30 °C ambient |
| Power Supply | Rechargeable lithium-ion battery (≥8 hrs continuous operation) |
| Compliance | Designed per ISO 5725 (accuracy verification), aligned with IDF Standard 192 (Milk Cryoscopy), and supports GLP data integrity requirements |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BG9711A |
| Price | Upon Request |
| Detector | Ø40×37 mm NaI(Tl) Scintillation Crystal |
| Measured Radionuclides | Cs-137, Cs-134 (calibration-compatible with I-125, Co-60, etc.) |
| Detection Limit | 20 Bq/L (relative to Cs-137) |
| Measurement Protocol | 30-min background + 10-min sample |
| Lead Shielding Thickness | 25 mm |
| Display | LCD showing activity or specific activity with uncertainty estimation |
| Background Subtraction | Enabled |
| LED Status Indicators | Green (safe), Yellow (elevated), Red (exceeds regulatory threshold) |
| Operating Temperature | 10–35 °C |
| Operating Humidity | ≤80% RH at 40 °C |
| Primary Power | DC 9 V / 1000 mA adapter |
| Backup Power | Two AA batteries |
| Power Consumption | <200 mW |
| Dimensions (L×W×H) | 190×190×350 mm |
| Net Weight | 26.4 kg |
| Data Storage | 200 measurement records |
| Connectivity | Optional USB interface for PC-based control and data export |
| Compliance | Designed for field-deployable radiological screening per IAEA Safety Guides RS-G-1.8 and national food/water monitoring protocols |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LB-QM6 |
| Detection Sensitivity | 1×10⁻¹⁵ mol ATP |
| RLU Range | 0–999,999 RLU |
| Background Noise | ≤2 RLU |
| Detection Limit | 1.0 CFU/mL |
| Assay Time | 10 s |
| Accuracy | ±5% or ±5 RLU |
| Overrange Protection | Tilt-activated interruption |
| Display | 3.5-inch color TFT LCD |
| Data Storage | 10,000 records |
| Connectivity | USB + Bluetooth v5.0 |
| Output Options | Optional Bluetooth thermal printer |
| Power Supply | Rechargeable Li-ion battery (AC travel charger included |
| Battery Life | >10 h |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–80% RH |
| Dimensions | 70 × 35 × 190 mm |
| Weight | 300 g |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi880 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interfaces | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Power Supply | 90–240 V AC (external adapter) |
| Housing | Steel with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heater | Up to 95 °C |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Software Features | GLP-compliant reporting, operator ID, sample ID, timestamp, RCMSi remote calibration and maintenance system |
| Built-in Color Scales | Lovibond RYBN, ASTM D1500, IP 17, ICUMSA, AOCS, Saybolt, CIE XYZ/xyY, spectral reflectance data |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | LPC500 + Avio500 |
| Application | Elemental Analysis & Particle Counting in Lubricants |
| Sample Volume | <1 mL per dual analysis |
| Cycle Time | ≤45 seconds per sample |
| Brand | LUM GmbH |
|---|---|
| Origin | Germany |
| Model | LUMiFlector |
| Application Principle | Near-Infrared and UV-Visible Multi-Reflection Spectroscopy (MRS®) |
| Measurement Time | <20 s (lab), <8 s (inline) |
| Sample Handling | Non-contact, no sample preparation, no reagents |
| Output Parameters | Up to 4 simultaneous quantitative attributes (e.g., fat, protein, dry matter, total solids) |
| Calibration | Product-specific multivariate calibration models |
| Interface | 4× 4–20 mA analog I/O, 4× 24 V digital outputs, VARINLINE® process housing (inline version) |
| Compliance Context | Designed for GLP/GMP-aligned QA/QC environments |
| Brand | LUMEX |
|---|---|
| Origin | USA |
| Model | RP100SC |
| Sample Pressure Range | Up to 6000 PSIG → Adjustable Output: 0–100 PSIG |
| Response Time | ≤1 s |
| Mercury Detection Compatibility | ppm-level Hg analysis |
| Thermal Control | Dual-stage heat exchangers + Joule–Thomson compensation via electrically heated inlet |
| Safety Certification | Suitable for Class I, Division 2 hazardous areas |
| Surface Treatment | SilcoNert®2000 inert passivation |
| Flow Path Configuration | Helical long-path regulator |
| Filtration | Integrated particulate filter at inlet |
| Interface Options | Tedlar® bag coupling + direct online integration with mercury analyzers (e.g., RP-915NG) |
| Compliance | SY/T 7321–2016 (Determination of Mercury in Wellhead Natural Gas by Differential Method) |
| Brand | LXtech |
|---|---|
| Model | LX-HT-CRF |
| Origin | Anhui, China |
| Type | Industrial & Academic Catalyst Evaluation Platform |
| Temperature Range (Configurable) | 20–1000 °C |
| Pressure Range (Configurable) | Ambient to 5 MPa |
| Max Parallel Sample Capacity | 1000 |
| Gas Channels (Configurable) | 1–3 |
| Thermal Uniformity | ±0.1 °C to ±1 °C (model-dependent) |
| Imaging Resolution (Configurable) | up to 640×512 pixels |
| Catalyst Loading Volume | 0.02–2 mL (customizable) |
| Compliance | Designed for ASTM D3241, ISO 1171, USP <621>, and GLP/GMP-aligned data integrity workflows |
| Brand | Magtech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MT-NMR-Series |
| Pricing | Available Upon Request |
| Brand | Magtech |
|---|---|
| Model | MTNMR20 |
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Compliance | GB/T 15690–2008, ISO 10565 |
| Imaging Modes | T1-weighted, T2-weighted, Proton Density (PD)-weighted, T2*-weighted |
| Suppression Capabilities | Water-suppressed imaging, Oil-suppressed imaging |
| Measurement | Simultaneous oil & moisture quantification without drying |
| Sample Throughput | ~15 seconds per sample |
| Non-destructive | Yes |
| Sample Representativeness | Bulk-volume signal acquisition (vs. surface-limited NIR) |
| Brand | Magtech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MTRMI Series |
| Pricing | Available Upon Request |
| Brand | Makeway |
|---|---|
| Origin | Japan |
| Model | 1600 |
| Instrument Type | Temperature-Variable Hall Effect Tester (Microwave-Based, Non-Contact) |
| Operating Frequency | 10 GHz |
| Current Source Range | 20 mA (for auxiliary calibration & optional DC bias) |
| Sample Diameter Support | 4–8 inch wafers |
| Carrier Mobility Range | 100–3000 cm²/V·s |
| Measurement Modes | Single-Point & Area Mapping |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | Shanda Instruments |
|---|---|
| Model | SD-BQ12T |
| Origin | Shandong, China |
| Instrument Type | Benchtop Integrated Spectrophotometric Analyzer for MDA Quantification in Edible Animal Fats |
| Detection Principle | Colorimetric Assay (Thiobarbituric Acid Reactive Substances, TBARS) |
| Display | 10.1-inch Vertical Touchscreen (Android OS, ARM Cortex-A7 RK3288 Quad-Core @ 1.88 GHz) |
| Optical System | Four-Wavelength Cold Light Source per Channel (410 / 520 / 590 / 630 nm), Patented Optical Path Switching Enabling Up to 64 Wavelengths |
| Detection Channels | ≥12 Simultaneous Channels with Precision Rotating Cuvette Holder |
| Calibration | One-Touch Auto-Calibration with Persistent SP Storage of Light Source Parameters |
| Data Storage | ≥200,000 Records, USB Exportable as Excel Files, Password-Protected Access |
| Connectivity | Dual USB, RJ45 Ethernet, Bluetooth 4.2, 4G APN Module, Wi-Fi |
| Software Expandability | Pre-Configured for 60+ Food Safety Assays |
| Compliance Framework | Designed for Routine Use in GLP-Compliant Food Quality Control Environments |
| Brand | Anoxomat |
|---|---|
| Origin | Netherlands |
| Model | MARVIN |
| Instrument Type | Seed Image Analysis and TGW Determination System |
| Seed Diameter Range | ≥0.8 mm (Standard Version), ≥0.2 mm (High-Resolution Version) |
| Pixel Resolution | 0.15 mm (Standard), 0.10 mm (High-Resolution) |
| Imaging Area | 65 cm² (Standard), 325 cm² (High-Resolution) |
| Analysis Speed | 1–3 s per sample |
| Measurement Accuracy | <1% error |
| Measured Parameters | Seed Count, Thousand-Grain Weight (TGW), Hectoliter Weight (HLW), 2D Morphometrics (Length, Width, Aspect Ratio, Roundness, Convexity), Particle Size Distribution Classification |
| Sample Mass Capacity | 50 g |
| Minimum Weighing Increment | 0.005 g |
| Moisture Determination Range | ±3% (when integrated with optional moisture module) |
| Operating Ambient Temperature Range | 20 °C ±2 °C |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Masterscreen |
| Pricing | Available Upon Request |
| Brand | MATHIS |
|---|---|
| Origin | Canada |
| Model | ESP™ |
| Application Domain | In-line blend uniformity monitoring for solid dosage forms |
| Measurement Principle | Differential thermal sensing (calorimetric-based mixing signature analysis) |
| Sample Forms | Dry powders, granules, semi-solids, suspensions, waxy matrices |
| Compliance Context | Designed to support FDA Process Analytical Technology (PAT) initiative, aligned with ICH Q8(R2), Q9, and Q10 |
| Brand | APEL |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M2HA-350X |
| Pricing | Upon Request |
| Rated Voltage/Current | AC125V/1–50 mA, AC250V/1–50 mA, DC5V/1–50 mA, DC48V/1–50 mA |
| Electrical Life | ≥3,000 cycles (at rated load) |
| Trip Temperature | OFF at ≥350°C (±5°C), ON at ≤325°C (±5°C) |
| Differential | 25 K |
| Dimensions | 56 × 17 × 9 mm |
| Housing Material | Alumina (Al₂O₃) ceramic |
| Max. Ambient Operating Temperature | 400°C |
| Application | Overheat protection for heating elements and electronic control units |
| Brand | McScience |
|---|---|
| Origin | South Korea |
| Model | SS-LD50 |
| Automation Level | Fully Automatic |
| Effective Test Area | 55 mm × 55 mm |
| Voltage Measurement Accuracy | ±0.02% of reading |
| Current Measurement Accuracy | ±0.03% of reading |
| Spectral Classification | AAA (IEC 60904-9:2020 Ed.3, ASTM E927-19) |
| Light Source | Multi-channel High-Power LED Array |
| Spectral Tunability | Yes, per-channel LED current control |
| Compliance | IEC 61215, IEC 61646, IEC 62108, UL 1703, JIS C 8912 |
| Brand | Topo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RD-2 |
| Pricing | Upon Request |
| Control Mode | Intelligent Manual Operation |
| Brand | Messmer Buchel |
|---|---|
| Origin | Netherlands |
| Model | 58-06 |
| Test Pressure Range | 490–5000 kPa (adjustable) |
| Standard Test Pressure | 1980 kPa |
| Measurement Range | 0.2–6.5 µm (normal mode) |
| Measuring Ring Width | 51 µm |
| Measuring Ring Circumference | 10.0 cm |
| Clamping Pressure Options | 500 / 1000 / 2000 kPa (100–5000 kPa fully adjustable) |
| Air Permeability Range (optional) | 0–10000 mL/min |
| Power Supply | 110 V/60 Hz or 220 V/50 Hz |
| Compressed Air Requirement | 600 kPa, clean and dry |
| Dimensions (L×W×H) | 558 × 430 × 380 mm |
| Weight | 39 kg |
| Data Output | RS-232 or thermal printer |
| Compliance | GB/T 2679, ISO 8791-4, TAPPI T555 |
| Brand | AQUALAB |
|---|---|
| Origin | USA |
| Model | AquaLab TDL 2 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) at H₂O-specific isotopic absorption line (1368.59 nm) |
| Range | 0.0000–1.0000 aw |
| Resolution | 0.0001 aw |
| Accuracy | ±0.005 aw @ 25 °C |
| Repeatability | ±0.001 aw |
| Temperature Control Range | 15–50 °C |
| Temp. Accuracy | ±0.1 °C |
| Measurement Time | ≤5 min (standard), 1 min (optional rapid mode) |
| Operating Environment | 0–90% RH non-condensing, 4–50 °C ambient |
| Interface | RS-232 & USB |
| Compliance | USP <922>, AOAC Official Method 2014.01, ISO 21807:2022, ASTM F1980-22 |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Metorex C100 |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Portability | Fixed-Installation |
| Analyte | Total Sulfur |
| Measurement Range | 0.5 ppm to 10 wt% |
| Analysis Mode | Real-Time Continuous Monitoring |
| Detection Limit | 0.5 ppm (S, in liquid hydrocarbons) |
| Accuracy | Compliant with ASTM D4294 and ASTM D7212 |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 892 |
| Heating Range | 50–220 °C (0.1 °C resolution) |
| Sample Capacity | 8 independent reaction vessels |
| Air Flow Control | 1–25 L/h (integrated diaphragm pump, calibrated at 25 °C/1013 hPa) |
| Conductivity Measurement Range | 0–400 µS/cm |
| Temperature Uniformity | <0.3 °C between vessels |
| Temperature Stability | <0.1 °C at setpoint |
| Data Acquisition Interval | 12 s |
| Interface | USB-controlled, PC-based operation |
| Compliance | Fully compliant with FDA 21 CFR Part 11 (via StabNet™ client-server architecture), GLP/GMP-ready audit trail and user role management |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Country of Origin | Imported |
| Model | 892 |
| Pricing | Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 893 Professional Rancimat |
| Pricing | Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported Instrument |
| Model | 895 Professional |
| Pricing | Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Origin Category | Imported |
| Model | 895 Professional |
| Pricing | Upon Request |
| Heating Modules | 2 (4 positions per module, total 8 measurement positions) |
| Control Interface | PC-based StabNet software |
| Measurement Principle | Conductometric detection of HCl evolution during thermal decomposition |
| Sample Format | Disposable glass reaction tubes |
| Detection Method | Real-time conductivity monitoring in deionized water trap |
| Compliance Standards | DIN 53381-1, ISO 182-3 |
| GLP Support | Full audit trail, user access control, electronic signature readiness, automatic database backup |
| Max Instrument Network | Up to 4 units controlled by a single PC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Easy Na |
| Pricing | Upon Request |