Industry-specific Instruments
Filter
Showing 1441–1470 of 2171 results
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PS-PM201 |
| Price Range | USD 3,300 – 4,200 (FOB) |
| Instrument Category | Laboratory Analyzer |
| Test Parameter | Foam Tendency & Foam Stability |
| Compliant Standards | GB/T 12579, ASTM D892 |
| Temperature Control Range | Low Bath 24 °C / High Bath 93.5 °C |
| Temperature Accuracy | ±0.5 °C |
| Display | High-Resolution Color Touchscreen |
| Power Consumption | 3300 W |
| Air Flow Rate | 94 ± 5 mL/min per diffuser |
| Diffuser Diameter | Ø25.4 ± 0.02 mm |
| Maximum Pore Size | ≤80 µm |
| Air Permeability at 2.44 kPa (250 mm H₂O) | 3000–6000 mL/min |
| Electrical Supply | AC 220 V ±5%, 50 Hz ±5% |
| Operating Ambient | 10–35 °C, ≤85% RH |
| Net Weight | 39 kg |
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Model | PS-SD01 |
| Light Source | 220 V / 100 W frosted incandescent lamp (color temperature 2750 ± 50 K) |
| Color Disc | 26 apertures (Φ14 mm), 25 loaded with calibrated glass color standards (ASTM D1500 / GB/T 6540 / ISO 2049 equivalent No. 1–25), 1 blank aperture |
| Viewing System | Compound optical eyepiece (concave + convex lenses) with focus and brightness adjustment |
| Power Supply | 220 V ± 10 %, 50 Hz ± 1 Hz |
| Compliance | SH/T 0168–92, GB/T 6540–2016, ASTM D1500–22, ISO 2049:2018 |
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Product Type | Imported Reference Solar Cell |
| Model | Outdoor Photovoltaic Reference Cell |
| Certification | Compliant with IEC 60904-2 |
| Effective Area | 1 cm² |
| Open-Circuit Voltage (Voc) Temperature Coefficient (TCR) | < 25 ppm/K |
| Voc Tolerance | ±1% |
| Shunt Resistance | 0.004 Ω (for split 156-cell configuration) or 0.13 Ω (for 20 mm × 40 mm shunt resistor, adjustable) |
| Integrated Sensor | Class A RTD-Pt100 (4-wire) |
| Electrical Interface | Amphenol Eco-Mate connectors (X2) for Voc (2-wire), Isc (2-wire), RTD (4-wire), and optional auxiliary cells (2-wire each) |
| Calibration Traceability | NREL (USA) or NIM (China) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-2 |
| Light Source | 1800 W Air-Cooled Xenon Lamp |
| Spectral Range | Full-spectrum Solar Simulation (UV, Visible, NIR) |
| Irradiance Control | Solar Eye® Closed-Loop Radiometer System |
| Temperature Control | Black Panel Temperature (35–105 °C), Chamber Air Temperature |
| Humidity Control | Standard Relative Humidity (RH) Regulation (Requires Deionized Water) |
| Optional Feature | Water Spray Function (Operates in Light/Dark Cycles) |
| Sample Capacity | 31 Specimens (46 mm × 122 mm) |
| Compliance | ISO 4892-2, ASTM G155, AATCC TM16, ISO 105-B02/B04/B06, GB/T 8427, JIS L0843, SAE J2527, PV 1303, VDA 675242, and >30 Other International Standards |
| Calibration Traceability | NIST-Traceable, ISO/IEC 17025 Accredited Laboratory |
| Connectivity | Built-in Ethernet, Remote Monitoring & Data Logging Support |
| User Interface | Multilingual Controller (EN/FR/ES/IT/DE), Self-Diagnostic Alerts, Virtual Bar Chart Software Integration |
| Brand | Qigao Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-0613G |
| Temperature Range | Ambient to 90 °C |
| Compliant Standard | Chinese Pharmacopoeia 2025 (ChP 2025) |
| Test Method | ChP Method 0613 for Freezing Point Determination |
| Control Accuracy | ±0.1 °C |
| Measurement Accuracy | ±0.1 °C |
| Temperature Sensor | Pt100 (1/3 DIN Class B) |
| Heating Element | Stainless Steel Immersion Heater |
| Display | 5.7″ TFT LCD, 65K-color, Full-touch Industrial Panel |
| Printing | 20-character Thermal Dot-Matrix Printer |
| Sample Handling | Dual-sample Mechanical Stirring |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | ≤1000 W |
| Dimensions (W×H×D) | 320 × 500 × 460 mm |
| Operating Environment | 0–45 °C, RH < 80% |
| Enclosure Material | Powder-Coated Aluminum Chassis |
| Bath Vessel | Double-Walled Vacuum Insulated Transparent Dewar |
| Illumination | Integrated LED Sample Chamber Lighting |
| Self-Diagnostic Routine | Built-in System Health Check |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | HSY-14190 |
| Price Range | USD 420 – 4,200 (FOB Shanghai) |
| Compliance | GB/T 14190–2017 |
| Measurement Principle | Ubbelohde capillary viscometry in dilute solution |
| Temperature Control Range | Ambient to 100 °C |
| Accuracy | ±0.1 °C |
| Bath Capacity | 20 L dual-cylinder constant-temperature bath (300 × 300 mm inner cylinder, 4-port configuration) |
| Capillary ID | 0.88 mm |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Total Power Consumption | ≤1800 W |
| Dimensions (Main Unit) | 430 × 500 × 660 mm (L×W×H) |
| Refrigerator Unit (Optional) | 430 × 430 × 300 mm |
| Net Weight | 50 kg |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-4509K |
| Pricing | Upon Request |
| Temperature Control Range | 20.00 °C to 50.00 °C |
| Temperature Control Accuracy | ≤ ±0.1 °C |
| Penetration Measurement Accuracy | ≤ ±0.1 mm |
| Maximum Penetration Depth | 660 penetration units (0.1 mm increments) |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-4985 |
| Penetration Range | 0–650 dmm |
| Timing Options | 5 s, 8 s, 10 s, 12 s, 30 s, 60 s (±0.1 s accuracy) |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Standard Needle Mass | 2.5 g ±0.05 g |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤300 W |
| Dimensions | 280 × 350 × 700 mm (L×W×H) |
| Optional Accessories | Cooled/heated bath (5–40 °C), magnifier with cold light source, interchangeable needle/cone attachments |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-7323 |
| Power | 1500 W |
| Temperature Control Range | Ambient to 95 °C |
| Temperature Accuracy | ±1 °C |
| Heating Method | Water Bath |
| Control System | Digital PID Temperature Controller |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 0–45 °C, ≤80% RH |
| Brand | Qigao Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HSY-8146H |
| Temperature Range | Ambient to 162 °C |
| Temperature Resolution | 0.1 °C |
| Brand | Qigao Instruments / SHqigao |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | SYD-2801 |
| Price | Upon Request |
| Penetration Range | 0–700 dmm |
| Minimum Readout | 0.1 dmm |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Temperature Range | 5.0–100.0 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 5.5 L |
| Circulation Flow Rate | 5 L/min |
| Pump Head | 1 m |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Power Consumption | ≤1800 W |
| Dimensions (L×W×H) | 520 × 330 × 600 mm |
| Brand | Qigao Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XRY-1B |
| Thermal Capacity | 10500–14500 J/K |
| Temperature Resolution | 0.0001 K |
| Heat Value Accuracy | ±60 J/g |
| Repeatability Error | ≤0.2% (Class C) |
| Oxygen Bomb Pressure Rating | 20 MPa |
| Temperature Measurement Range | 10–35 °C |
| Ambient Operating Temperature | 20 °C ±5 °C (max. fluctuation ±1 °C during test) |
| Data Storage Capacity | 1000 records |
| Relative Humidity Limit | ≤85% RH |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Power Consumption | ≤150 W |
| Dimensions (L×W×H) | 720 × 580 × 470 mm |
| Brand | QINGTAO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | QT-KY01 |
| Max Test Load | 2000 kgf |
| Accuracy Class | Class 1 (per GB/T 16491 / ISO 7500-1) |
| Force Measurement Range | 0.4–100% FS |
| Force Accuracy | ±1% of reading |
| Force Resolution | 1/200,000 |
| Displacement Accuracy | ±1% of reading |
| Displacement Resolution | 0.05 mm |
| Test Speed Range | 10–300 mm/min |
| Speed Accuracy | ±1% of set value |
| Test Chamber Dimensions (optional) | 600×600×600 mm, 800×800×800 mm, 1000×1000×1000 mm, 1200×1200×1200 mm, or 1500×1500×1500 mm |
| Control System | Embedded microcomputer with optional industrial touchscreen interface |
| Drive System | Gearmotor + frequency inverter |
| Motor Power | 0.75 kW |
| Compliance Standards | ISO 2872, ISO 2874, TAPPI T 804, JIS Z 0212, NF H3 001, CNS 2236 / 3511, QB/T 1048 |
| Brand | QKTester |
|---|---|
| Model | COFT_02 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | GB 10006–1988, ISO 8295, ASTM D1894 |
| Test Modes | Static & Kinetic CoF |
| Load Range | 0–50 N (typical) |
| Speed Range | 10–300 mm/min |
| Force Resolution | ≤0.01 N |
| Sample Stage | Horizontal Dual-Surface Fixture |
| Data Output | Real-time force-time curve, CoF values (μs/μk), pass/fail flagging |
| Interface | 7″ TFT LCD touchscreen with embedded test protocol library |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HSPT-01 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–0.7 MPa |
| Sealing Jaw Dimensions | 150 mm × 10 mm (customizable) |
| Heating Mode | Single- or Dual-Side Heating |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Compliant Standards | QB/T 2358, ASTM F2029, YBB 00122003 |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | OGT-01 |
| Price | USD 145 (FOB) |
| Measured Gases | O₂, CO₂ |
| Measurement Principle | Electrochemical (O₂), Non-Dispersive Infrared (NDIR) Absorption (CO₂) |
| Sample Volume | O₂ < 3 mL |
| Resolution | 0.01% (v/v) |
| Accuracy | ±0.2% (v/v) |
| O₂ Range | 0.2–21.0% (v/v) |
| Standard Sampling Volume | ≥5 mL at 101.3 kPa |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 5.5 kg |
| Brand | QKTester |
|---|---|
| Model | OGT-01 |
| Origin | Shandong, China |
| Manufacturer | QKTester Instrument Co., Ltd. |
| Gas Measurement | O₂ (standard), CO₂ (optional) |
| Principle | Electrochemical sensor (O₂), NDIR (CO₂, optional) |
| Range | 0–100% O₂ |
| Resolution | 0.01% |
| Accuracy | ±0.2% O₂ |
| Sample Volume | <3 mL |
| Dimensions | 230 × 120 × 82 mm |
| Weight | 1 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Data Storage | 1500 records |
| Display | Backlit LCD, bilingual (English/Chinese) |
| Interface | Built-in thermal printer |
| Compliance | Designed for ISO 8573-1, USP <1207>, ASTM F2476, and GMP-aligned environmental monitoring workflows |
| Brand | QKTester |
|---|---|
| Model | OGT-02 |
| Measurement Principle | Electrochemical (O₂), NDIR Infrared Absorption (CO₂, optional) |
| Gas Types | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0–100% vol, Resolution: 0.01%, Accuracy: ±0.2% |
| CO₂ Range | 2–100% vol, Resolution: 0.01%, Accuracy: ±(0.03% + 5% of reading) |
| Sensor Lifetime | ~2 years (O₂), >15 years (CO₂) |
| Sample Volume | ≥6 mL (O₂), ≥20 mL (CO₂) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions | 350 × 310 × 220 mm |
| Weight | 3.2 kg |
| Compliance | Designed for GMP/GLP environments |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WVTR-C1 |
| Test Range | 0.1–10,000 g/m²·24h |
| Test Accuracy | 0.01 g/m²·24h |
| Temperature Range | 10°C–55°C (±0.1°C to ±0.5°C) |
| Humidity Range | 10%RH–90%RH (±1%RH to ±2%RH) |
| Air Velocity | 0.5–2.5 m/s |
| Test Area | 33.18 cm² |
| Specimen Diameter | Φ72–Φ74 mm |
| Test Stations | 1–3 |
| Dimensions | 450×500×550 mm to 850×890×520 mm |
| Power Supply | AC 220 V, 50 Hz |
| Standards Compliance | GB/T 1037, GB/T 16928, ISO 2528, ASTM E96, ASTM D1653, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003-2015 |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-S3000D |
| Measurement Principle | Non-dispersive Infrared (NDIR) for C/S |
| Analysis Time | ~2 min per sample |
| Compliance | GB/T 223.3–5:1988, GB/T 223.68–69:1997 |
| Elemental Range (Typical) | C: 0.001–10.00 wt%, S: 0.0005–0.5000 wt%, Mn: 0.10–15.00 wt%, Si: 0.10–5.00 wt%, P: 0.005–0.80 wt%, Cr: 0.01–25.0 wt%, Ni: 0.010–30.0 wt%, Mo: 0.101–6.00 wt%, Ti: 0.01–1.00 wt%, Cu: 0.01–10.00 wt%, Al: 0.01–8.00 wt% |
| Calibration | 99 programmable calibration curves (regression-based), expandable |
| Data Output | PC-controlled interface, customizable export formats (CSV, TXT, XML), thermal desktop printer support |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | qphox |
| Pricing | Available Upon Request |
| Brand | QuankeRida / qktester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | OGT-01 |
| Price | USD 145 (converted from ¥999 at 1:6.9) |
| Measurement Range | 0–21% O₂ (typical) |
| Accuracy | ±0.2% O₂ (full scale) |
| Sample Volume | ≥5 mL (at standard atmospheric pressure) |
| Detection Principle | Fluorescence Quenching or Electrochemical Sensing (user-selectable/configurable per unit) |
| Operation Mode | Manual probe insertion with real-time sensor response |
| Data Storage | Internal non-volatile memory (≥1,000 test records) |
| Power Supply | AC 220 V ±10% or rechargeable Li-ion battery (field-deployable) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Net Weight | 5.5 kg |
| Brand | QYB / Quantum Yield Berlin |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LuQY Pro+ |
| Price Range | USD 200,000 – 500,000 |
| Measurement Mode | DC |
| Excitation Wavelength | 532 nm |
| Maximum Laser Power | 140 mW |
| Tunable Photon Flux (Equivalent Current) | 4 µA – 40 mA |
| Excitation Spot Size Options | 0.1 cm² / 1 cm² |
| Spectral Range | 550 – 1050 nm |
| Minimum Detectable EL/PL Quantum Yield | 1×10⁻⁶ |
| Integration Time | 1 ms – 35 min |
| Spectral Sampling Interval | 1 nm |
| Signal-to-Noise Ratio | 600:1 |
| Voltage Source & Measurement Range | ±10 V, ±150 mA |
| Voltage Source Accuracy | 10 mV |
| Voltage Sensing Accuracy | 50 µV |
| Current Sensing Accuracy | 100 nA / 1 µA / 10 µA |
| Sample Holder | Customizable (Max Subcell Dimensions: 30 mm × 30 mm × 10 mm) |
| Max Simultaneous Subcells | 6 |
| Dimensions | 220 mm × 390 mm × 120 mm |
| Weight | 6.1 kg |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AB140 |
| Price Range | USD 27,000 – 68,000 |
| Heating Block Material | Aluminum |
| Sample Capacity | 5 positions |
| Sample Tube Dimensions | Ø17.5 ± 0.1 mm × 70 mm depth (tube body) |
| Temperature Sensor | PT100 probe |
| Temperature Control | PID controller with independent control cabinet |
| Max Setpoint | 140 °C |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | 230 V / 50 Hz, 300 VA |
| Safety Features | Over-temperature cut-off protection |
| Accessories Included | 5 calibrated cylindrical sample tubes (with three annular bands), perforated rubber stoppers, platinum-tipped glass rods, KI-starch test paper support fixture |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Radioisotope Source Capsule Automatic Inspection System |
| Pricing | Available Upon Request |
| Brand | YIXIST |
|---|---|
| Model | ROE-ME04 |
| Type | Educational Practical Training Device for Optical Metrology |
| Origin | Zhejiang, China |
| Compliance | Designed for ISO/CIE-aligned academic metrology education |
| Software Interface | CIE 1931 xy Chromaticity Diagram Integration, Spectral Data Export (CSV, TXT) |
| Measurement Support | Radiant Flux (W), Luminous Flux (lm), Illuminance (lx), Luminous Efficacy (lm/W), Chromaticity Coordinates (x, y), Correlated Color Temperature (CCT, K) |
| Brand | RAE Systems |
|---|---|
| Origin | USA |
| Model | FGM-1200S |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Sensor Type | Smart Digital NDIR |
| Installation | Fixed Wall/Mast Mount |
| Enclosure Material | Stainless Steel |
| Protection Rating | IP65 |
| Explosion Protection | ATEX II 2G EEx d II CT6, UL/CSA Certified |
| Operating Temperature | CH₄: −40 °C to +70 °C |
| CO₂ | −20 °C to +60 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Pressure Range | 90–110 kPa |
| Power Supply | DC 9–36 V, 60 mA (170 mA @ 24 VDC) |
| Output Signals | 4–20 mA (adjustable, 600 Ω load), RS485 Modbus RTU, Two Programmable Dry Contact Relays (30 VDC, 2 A) |
| Response Time (T90) | ≤30 s |
| Accuracy | ±2% FS |
| Sampling Method | Diffusion |
| Display | Backlit LCD with Four-Color Status LEDs |
| Dimensions (H×W×D) | 168 × 150 × 109 mm |
| Weight | 3.5 kg |
| Brand | RAE Systems |
|---|---|
| Origin | USA |
| Model | PGM-1600 |
| Dimensions | 21 × 8.5 × 6.5 cm |
| Weight | 700 g (with Li-ion battery) |
| Sampling Method | Pump-assisted |
| Enclosure Material | Engineering plastic with rubber overmold |
| Ingress Protection | IP65 |
| EMC Compliance | EMC Directive 89/336/EEC |
| Operating Temperature | −20 °C to +50 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Hazardous Area Certification | Ex ia(d) IIC T4 |
| Display | Graphic LCD with auto-backlight |
| Languages | Chinese, English + icons |
| Alarm | 95 dB @ 30 cm audible alarm, dual-color LED flash |
| Alarm Types | High/Low gas concentration, low battery, sensor fault, pump blockage |
| Data Storage | SD card (Excel-compatible format) |
| Sampling Interval | 1–3600 s adjustable |
| Pump Flow Rate | 450–550 cc/min |
| Battery | 3.7 V rechargeable Li-ion |
| Runtime | Up to 16 h (typical field use) |
| Charge Time | 8 h |
| Calibration | Zero and span calibration |
| Sensor Options | LEL or LEL/VOL catalytic bead sensor |
| Sensor Specifications | O₂ (0–30% vol, 0.1% res., T90 ≤15 s) |
| LEL/VOL (dual-range | 0–100% LEL / 0–100% vol, 1% res., T90 ≤15 s) |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | MFR200 |
| Load Cell Resolution | 0.1 g |
| Temperature Range | Ambient to 450 °C (±0.2 °C stability) |
| Standard Orifice | 2.095 mm diameter × 8.00 mm length |
| Piston Travel | 30 mm |
| Cut-Off Timing Accuracy | ±0.1 s |
| Weight Loading Options | Manual or Pneumatic (up to 11 bar, equivalent to ~21.6 kg force) |
| Compliance | ASTM D1238, ISO 1133-1 & ISO 1133-2, GB/T 3682 |
| Brand | Ray-Ran |
|---|---|
| Origin | Netherlands |
| Model | MFR300 |
| Temperature Range | 0–450 °C (500 °C optional) |
| Temperature Accuracy | ±0.10 °C |
| Temperature Resolution | 0.10 °C |
| Piston Displacement Resolution | ±0.02 mm |
| Heating Zones | Dual-zone |
| Power Supply | 110 V/60 Hz or 220 V/50 Hz, 10 A fuse |
| Connectivity | Wi-Fi, USB, Ethernet |
| Compliance | ISO 1133, ASTM D1238, GB/T 3682 |