| Brand | SATAKE |
|---|---|
| Origin | Japan |
| Model | TM05C |
| Instrument Type | Benchtop |
| Analysis Time | 0.5 min |
| Sample Capacity | 1.2 kg |
| Feed Rate Control | Adjustable via 8-step pulley system |
| Abrasive Roll Rotation Speed | 750–1450 rpm |
| Power Supply | Single-phase AC 100 V, 50/60 Hz |
| Power Consumption | 0.4 kW |
| Dimensions (H×W×D) | 386 × 580 × 374 mm |
| Net Weight | 43.2 kg |
| Wavelength Range | Not applicable (mechanical milling device) |
| Scan Speed | Not applicable |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CV-100 |
| Pricing | Upon Request |
| Measurement Principle | Falling Needle (Capillary-Free Gravitational Sedimentation) |
| Viscosity Range | Up to 1 × 10⁹ cP |
| Time Resolution | 0.001 s |
| Temperature Control | Optional Water Jacket (–40 to 150 °C) |
| Interface | RS-232 |
| Sample Tube | Disposable Polypropylene Caulking Tube (reusable up to 30× with proper cleaning) |
| Compliance | ASTM D1084, ISO 2555, USP <911>, GLP-compatible data logging |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | DV-100 |
| Viscosity Range | 0.7–10⁶ cP (mPa·s) |
| Temperature Range | 0–100°C |
| Accuracy & Repeatability | <1% |
| Sample Volume | 4.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density Range | 6–130 g/cm³ |
| Falling-Time Resolution | 0.001 s |
| Instrument Weight | 7.3 kg |
| Interface | RS-232 |
| Sample Tube | Disposable (reusable up to 30×) |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | FNV-200 / CNV-100 |
| Viscosity Range (FNV) | 0.5–2.4×10⁶ cP |
| Viscosity Range (CNV) | 0.1–30 cP |
| Shear Rate Range (FNV) | ~10⁻⁴–10⁴ s⁻¹ |
| Temperature Range | −40 to 150 °C |
| Accuracy & Repeatability | <1% |
| Sample Volume (FNV) | ~110 cm³ |
| Sample Volume (CNV) | ~85 cm³ |
| Needle Material | Aluminum, Titanium, Stainless Steel, or Borosilicate Glass |
| Needle Density Range | 1.01–8.0 g/cm³ |
| Instrument Weight | 18.2 kg |
| Dimensions (H×W) | 55 × 36 cm |
| Falling Time Resolution | 0.001 s |
| Interface | RS-232 |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HPHTV-100 |
| Viscosity Range | 0.7–10⁶ cP (mPa·s) |
| Temperature Range | 0–100°C (operational), up to 150°C (chamber capability) |
| Pressure Rating | Up to 2000 psi |
| Accuracy & Repeatability | <1% |
| Sample Volume | 4.5 cm³ |
| Needle Materials | Aluminum, Titanium, Stainless Steel |
| Needle Density Range | 6–130 g/cm³ |
| Falling-Time Resolution | 0.001 s |
| Console | Microprocessor-based with RS-232 interface |
| Automatic Needle Handling | Yes |
| Instrument Weight | 7.3 kg (16 lbs) |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HTV-100 |
| Pricing | Available Upon Request |
| Viscosity Range | 1–10⁸ cP (mPa·s) |
| Temperature Range | −40 to 200°C (standard) |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ~1.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density Range | 6–1000 g/cm³ |
| Instrument Weight | 5.4 kg (12 lbs) |
| Measurement Resolution | 0.001 s |
| Interface | RS-232 |
| Sample Tube | Disposable, No Cleaning Required |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | PDVa-100 |
| Viscosity Range | 0.7–10⁷ cP (mPa·s) |
| Temperature Range | Ambient |
| Accuracy & Repeatability | <1% |
| Sample Volume | ~4.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density Range | 6–130 g/cm³ |
| Instrument Weight | 2 kg (4.4 lbs) |
| Measurement Principle | Capillary-based falling-needle viscometry with automated timing |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PDVdi-120 |
| Price | Upon Request |
| Viscosity Range | 2–10⁶ cP (mPa·s) |
| Temperature Range | Ambient (15–30 °C typical field use) |
| Accuracy & Repeatability | ±2% of reading |
| Sample Volume | ~25 mL |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | 2.916 g/cm³ |
| Total Weight | 0.38 kg (0.83 lbs) |
| Compliance | ASTM D5478, SAE AIR5704 |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | SV-100 |
| Viscosity Range | 0.5–10,000 mPa·s |
| Temperature Range | −40 to +150 °C |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ≥1.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | ~7.0 g/cm³ |
| Operating Pressure | Up to 2,000 psi |
| Compliance | ASTM D5478 |
| Instrument Weight | 7.3 kg |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UHPV-100 |
| Price | Upon Request |
| Viscosity Range | 0.7–20,000 cP (mPa·s) |
| Pressure Range | Up to 60,000 psi |
| Temperature Range | −40 to +150 °C |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ~10 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | 7 g/cm³ |
| Instrument Weight | 68.0 kg (150 lbs) |
| Dimensions (H×W×D) | 61 × 107 × 61 cm |
| Brand | SCAVINI |
|---|---|
| Origin | Germany |
| Model | AD113 |
| Temperature Range | −10 °C to 40 °C |
| Ductility Extension Lengths | 50 cm, 100 cm, 150 cm |
| Load Measurement Range | 0–200 N |
| Load Resolution | 0.5 N |
| Temperature Control Accuracy | ±0.1 °C |
| Bath Material | Stainless Steel with PTFE-coated base |
| Cooling System | Integrated hermetic refrigeration compressor |
| Drive Mechanism | Variable-speed electric motor |
| Sample Capacity | 2 specimens simultaneously |
| Data Interface | RS-232 |
| Compliance | ASTM D113, ASTM D5976, IP 32, ISO 1208, GB/T 4508 |
| Brand | Schmidt + Haensch |
|---|---|
| Origin | Germany |
| Configuration | Modular Standalone or PC-Linked Dual-Unit System |
| Compliance | ICUMSA Method GS4/3-12 (2021) |
| Measurement Principle | Simultaneous Polarimetry & Refractometry |
| Temperature Compensation | Integrated Peltier-Controlled Cell with ±0.02 °C Stability |
| Display Options | Touchscreen or LCD Keypad Interface |
| Data Output | Direct thermal printer interface |
| Software Integration | S+H PuritySuite v3.2 (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready) |
| Sample Handling | Compatible with Autofilt Z automatic filtration for turbid/dark samples |
| Optical Platform | Quartz-wedge polarimetry (Saccharomat series) or digital Faraday-modulated polarimetry (Polartronic M series) + ATR-based refractometry (ATR-B/F/R models) |
| Typical Applications | Raw juice, thin juice, thick juice, molasses, syrups, monoclonal antibody formulations, recombinant protein solutions |
| Brand | Sciencetech |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SF Series |
| Price Range | USD 13,500 – 13,700 (FOB) |
| Operating Mode | Steady-State |
| Classification | Class AAA (per IEC 60904-9:2020 & ASTM E927-22) |
| Collimation | ≥95% collimated output (full-angle divergence < 2°) |
| Spectral Match | AM0 (space) and AM1.5G (terrestrial) configurable via interchangeable filter sets |
| Spatial Uniformity | ≤2% (measured over 2×2 cm² test area) |
| Temporal Stability | ≤0.5% RMS over 30 min (Class A per standard) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CSD01 |
| Pricing | Available Upon Request |
| Drum Internal Diameter | 286 mm |
| Drum Depth | 39 mm |
| Rotational Speed | 25 ± 1 rpm |
| Arc Baffle Inner Diameter | 80 ± 1 mm |
| Test Duration Range | 0–9 h 59 min 00 s |
| Rotation Count Range | 0–99,999 revolutions |
| Time Resolution | 1 second |
| Revolution Resolution | 1 revolution |
| Power Consumption | 20 W |
| Supply Voltage | AC 220 V, 50 Hz |
| Dimensions (W × D × H) | 440 × 286 × 350 mm |
| Net Weight | 10 kg |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | MDS-2008DS |
| Instrument Type | Offline Dissolution Tester |
| Vessel Capacity | 6 or 8 vessels |
| Temperature Accuracy | ±0.2°C |
| Temperature Resolution | 0.1°C |
| Water Bath Range | Ambient to 45.0°C |
| Rotational Speed Range | 10.0–300.0 rpm |
| Rotational Speed Resolution | 0.1 rpm |
| Rotational Speed Accuracy | ±0.5 rpm |
| Basket/Shaft Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Shaft-to-Vessel Axis Deviation | ≤±1.5 mm |
| Levelness | ≤0.2° |
| Shaft Verticality | 90° ±0.5° |
| Vessel Options | 250 mL and 1000 mL (amber option available) |
| Compliance | USP <711>, EP 2.9.3, ChP 0931 |
| Brand | SCIENTZ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZBJ01 |
| Pricing | Available Upon Request |
| Number of Test Stations | 3 |
| Stroke Distance | 55 mm ± 1 mm |
| Cycle Frequency | 30–32 cycles/min |
| Bath Temperature Range | Ambient to 45 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Control Accuracy | ±0.3 °C at 37 °C |
| Standard Sieve Aperture | 2 mm |
| Optional Sieves | 1 mm, 0.71 mm, 0.42 mm |
| User Access Levels | 3-tier |
| Max Users | 7 |
| Audit Trail Capacity | 96 entries × 366 days |
| Login Methods | Username + Password, Fingerprint |
| Temperature Sensor | High-Accuracy Pt1000 Platinum Resistance Thermometer |
| Circulation System | Brushless DC Recirculating Pump |
| Safety Features | Over-Temperature Protection Switch |
| Housing | Integrated Powder-Coated Injection-Molded Enclosure with Sandblasted Locating Baseplate |
| Display | Full-Color Touchscreen Interface |
| Illumination | Independent LED Lighting per Station |
| Basket Mounting | Quick-Release Cam Lock Mechanism |
| Bath Design | Monolithic Water Bath Chamber |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | SD-1 |
| Standards Compliance | ASTM D6450, SH/T 0768, DL/T 1354 |
| Measurement Method | Closed-Cup Pensky-Martens Equivalent (Automated Peltier-Cooled Ignition Detection) |
| Sample Volume | ≤ 2 mL |
| Test Time | Typically < 10 min per sample |
| Display | 7-inch Capacitive LCD Touchscreen (Android OS 8.1) |
| Data Output | Thermal Printer (Built-in), USB Export, Optional Ethernet/Wi-Fi Module |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions | 320 × 280 × 220 mm |
| Weight | 8.5 kg |
| Brand | SDL Atlas |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | D398 |
| Pricing | Upon Request |
| Application | Drying, Color Fixation, Baking, Thermosol Processing |
| Form Factor | Benchtop |
| Max Sample Size | 36 × 42 cm |
| Conveyor Mechanism | Automated Pin Chain Drive |
| Dwell Time Range | 10 s – 6 min (adjustable) |
| Heating Power | 6 kW |
| Temperature Range | 20–250 °C |
| Air Circulation | Forced convection fan system |
| Sample Holder | Interchangeable pin frame for variable fabric dimensions |
| Operation Mode | Batch (discontinuous) |
| Compatibility | Compatible with pneumatic padding mangle |
| Brand | SDL Atlas |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | D440 |
| Pricing | Upon Request |
| Temperature Range | 40–260 °C (105–500 °F) |
| Indication Principle | Thermochromic Phase Transition |
| Adhesion Type | Pressure-Sensitive Self-Adhesive Backing |
| Environmental Resistance | Resistant to Oil, Water, and Saturated Steam |
| Brand | SDL Atlas |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | F256A |
| Price Range | USD 14,000 – 70,000 |
| Brand | SDL Atlas |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | M258A-D |
| Measurement Range | 10 mm × 0.01 mm (standard) |
| Anvil Diameter | 30 mm |
| Footprint Options | 50 mm, 100 mm, 200 mm probe span |
| Construction | Aerospace-grade aluminum alloy body |
| Brand | SDL Atlas |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | M292 |
| Price Range | USD 14,000 – 70,000 |
| Brand | SDL Atlas |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | M228 |
| Price Range | USD 14,000 – 70,000 |
| Wash Canister Options | 8-position or 12-position |
| Canister Volumes | 550 mL or 1200 mL |
| Construction | Full 316 stainless steel housing |
| Control Interface | Full-color capacitive touchscreen |
| Language Support | English, Chinese, Spanish, Turkish |
| Safety Features | Interlocked door switch (rotor stops immediately upon door opening), momentary jog button for rotor positioning |
| Connectivity | RemoteAccess™ mobile monitoring (iOS/Android compatible) |
| Compliance | Designed to meet ISO 105-C06, ISO 105-C08, AATCC Test Method 61, GB/T 3921, and related textile washing fastness standards |
| Brand | SDM |
|---|---|
| Origin | Italy |
| Model | 2050 |
| Temperature Range | Ambient to 180 °C (±0.3 °C stability) |
| Power Supply | 220 V, 50/60 Hz |
| Heating Power | 3200 W |
| Dimensions | 58 × 46 × 54 cm |
| Weight | 27 kg |
| Compliance | ASTM D972, IP 183 |
| Bath Material | Stainless Steel |
| Control System | PID Digital Controller with PT100A Sensor |
| Safety Features | Overtemperature Alarm, Low-Level Liquid Warning Light |
| Stirring | Motorized Stainless Steel Agitator |
| Construction | Insulated Dual-Wall Bath with Stainless Steel Lid and Precision Flowmeter Mounting Ports |
| Brand | SDM |
|---|---|
| Origin | Italy |
| Model | 2440 |
| Temperature Range | Ambient to 210 °C (±0.1 °C stability) |
| Compliance | ASTM D2440, IP 307, ISO 7624, IP 48, IP 280, IP 306, IP 335, EN 61125-A/B/C |
| Construction | Double-walled stainless steel housing with thermal insulation |
| Temperature Control | PID controller with PT100A sensor and over-temperature alarm |
| Heating System | Stainless steel immersion heater |
| Agitation | Motor-driven magnetic stirrer |
| Safety Features | Low-level liquid sensor with visual alarm, drain cock, ventilated lid with ports for flowmeter and absorption tube |
| Power Supply | 220 V, 50/60 Hz |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Model | SDSCY16 |
| Dimensions (max) | Ø43 mm × 82 mm |
| Weight | ~0.4 kg |
| Oxygen Purity Requirement | ≥99.5% (cylinder-sourced only |
| Operating Pressure | 2.8–3.0 MPa (regulated via dedicated pressure-reducing valve) |
| Design Type | Handheld, single-hand operation |
| Construction | Compact, lightweight industrial-grade assembly |
| Brand | Seaward |
|---|---|
| Origin | United Kingdom |
| Model | PV200 |
| Automation Level | Fully Automatic |
| Effective Test Area | 1 m² (per module or string) |
| Voltage Measurement Accuracy | ±1% of reading |
| Current Measurement Accuracy | ±1% of reading |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Compass 4294 Plus |
| Pricing | Upon Request |
| Analytical Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Detector | High-Resolution Peltier-Cooled Fast Silicon Drift Detector (FSDD), FWHM <130 eV (Mn Kα) |
| Max Input Count Rate | 500,000 cps |
| Vacuum Capability | Integrated Miniature Vacuum Pump |
| Measurement Time | 130–300 s (user-configurable) |
| Sample Forms | Liquids, Solids, Powders |
| Operating Temperature | −20 to 50 °C |
| Dimensions (L×W×H) | 270 × 320 × 230 mm |
| Sample Chamber Size | 170 × 110 × 17 mm |
| Weight | 10.5 kg |
| Display | 8-inch Touchscreen (1280 × 800), Windows 10 OS |
| Data Interfaces | USB, Bluetooth, Wi-Fi, GPS |
| Safety | Interlocked Radiation Shielding, Real-Time Dose Indicator |
| Calibration | Auto-startup Calibration, Factory-Preloaded Calibration Curves (Low-S: 0–100 ppm |
| High-S | 0.01–5 wt% |
| Cl | 0–100 ppm) |
| Compliance Standards | GB/T 17040–2008, GB/T 17060–1998, GB/T 380–1977, GB/T 17411–2015, SH/T 0253–1992, ASTM D4294, ISO 8754, ISO 20847, IP 336, ASTM D6445, IP 496, ASTM D7220 |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SEN-320 |
| Instrument Type | Purity Analysis System |
| Imaging Sensor | 12 MP Color CMOS with Large Depth of Field |
| Backlight Panel | A3-size Ultra-thin Uniform LED Illuminator |
| Particle Diameter Range | 0.5–20 mm |
| Counting Speed | 1,200–20,000 seeds/min |
| Counting Accuracy | ≤ ±0.1–0.4% |
| Thousand-Seed Weight (TSW) Accuracy | ≤ ±0.5% |
| Morphometric Parameters Output | Length, Width, Aspect Ratio, Area, Equivalent Diameter, Perimeter, Bounding Rectangle |
| Image Processing | Auto-correction for Lens Distortion & Backlight Non-uniformity |
| Software Features | Customizable One-Click Analysis Protocols, Color/Shape Self-Learning Classification, Batch Adhesion Separation Algorithm, Barcode & RS232 Scale Integration |
| Data Export | Excel (.xlsx), Histograms (Size Distribution), Ranked Parameter Tables, Measurement Maps |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SEN-821 |
| Instrument Type | Portable |
| Function Type | Multifunctional |
| Moisture Range | 3–35% (w/w) |
| Net Weight | 1 kg |
| Power Supply | DC 6 V (4 × AA alkaline batteries) |
| Measurement Time | < 5 s |
| Accuracy | ±0.5% (w/w) |
| Temperature Compensation | Automatic |
| Calibration Method | Floating 4-point calibration |
| Pre-programmed Crops | 20 common varieties |
| Operating Ambient Temperature | 0–40 °C |
| Auto Power-off | After 3 minutes of inactivity |
| Bulk Density Conversion | Integrated sampling device for wheat bulk density calculation |