| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBB-F3 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±1 °C |
| Sealing Time Range | 0.01 s to 99.99 h |
| Sealing Pressure Range | 0.05–0.8 MPa |
| Sealing Surface Configuration | Five independent 35 mm × 10 mm upper sealing blades (heated) + one silicone-padded lower sealing bar (heated) |
| Heating Method | Dual-zone resistive heating (upper and lower independently controlled) |
| Pneumatic Source | Compressed air, 0.5–0.8 MPa |
| Dimensions (W×D×H) | 700 × 400 × 540 mm |
| Weight | 55 kg |
| Power Rating | 2000 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Compliance Standards | QB/T 2358–1998, ASTM F2029–2016, YBB 00122003–2015 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Equipment Co., Ltd. |
| Model | GBB-F3A |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.1–0.8 MPa |
| Sealing Surface | Five independent 35 mm × 10 mm upper sealing blades + silicone-padded lower sealing bar |
| Heating Mode | Electric heating with pneumatic actuation |
| Air Source | Compressed air (required) |
| Dimensions (L×W×H) | 730 × 400 × 535 mm |
| Weight | 35.6 kg |
| Power | 2000 W |
| Voltage/Frequency | AC 220 V, 50 Hz |
| Compliance Standards | QB/T 2358–1998, ASTM F2029–2016, YBB 00122003–2015 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBB-F4 |
| Price Range | USD 4,200 – 7,000 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±1 °C |
| Sealing Time Range | 0.01 s to 99.99 h |
| Sealing Pressure Range | 0.05–0.8 MPa |
| Sealing Surface Dimensions | Upper Jaw — Five 35 mm × 10 mm Segments |
| Heating Method | Dual Independent Heating (Upper & Lower Jaws) |
| Actuation | Pneumatic (Compressed Air, 0.5–0.8 MPa) |
| Dimensions (W×D×H) | 700 × 400 × 540 mm |
| Weight | 55 kg |
| Power Consumption | 2000 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Compliant Standards | QB/T 2358–1998, ASTM F2029–2016, YBB 00122003–2015 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBB-F8 |
| Price Range | USD 4,200 – 7,000 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±1 °C |
| Sealing Time Range | 0.1–999.9 s |
| Sealing Pressure Range | 0.05–0.8 MPa |
| Sealing Surface Dimensions | Upper Sealing Blades — 35 mm × 10 mm × 5 segments |
| Heating Method | Electric Resistance Heating with Dual Auto/Manual Operation Modes |
| Actuation | Pneumatic (Compressed Air Required) |
| Air Supply Requirement | 2.5 HP Compressor, 8 bar Output |
| Power Rating | 2000 W |
| Input Voltage/Frequency | AC 220 V, 50 Hz |
| Overall Dimensions | 700 × 400 × 540 mm |
| Net Weight | 55 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBB-F9 |
| Price Range | USD 4,200 – 7,000 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±1 °C |
| Sealing Time Range | 0.1–999.9 s |
| Sealing Pressure Range | 0.05–0.8 MPa |
| Sealing Surface Dimensions | Upper Jaw — Five 35 mm × 10 mm independent heating zones |
| Heating Method | Electric resistive with pneumatic actuation |
| Air Supply Requirement | Compressed air (min. 0.8 MPa, 2.5 HP compressor recommended) |
| Dimensions (W×D×H) | 700 × 400 × 540 mm |
| Weight | 55 kg |
| Power Rating | 2000 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBB-F90 |
| Price Range | USD 1,400 – 4,200 |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.1–0.8 MPa |
| Sealing Surface | Five independent 35 mm × 10 mm upper sealing bars |
| Heating Mode | Electric heating with dual auto/manual operation |
| Actuation | Pneumatic (compressed air required) |
| Air Supply | Compressed air source (recommended: 2.5 HP, 8 bar) |
| Dimensions (L×W×H) | 730 × 400 × 535 mm |
| Weight | 35.6 kg |
| Power | 2000 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Equipment Co., Ltd. |
| Model | GBB-F9A |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.1–0.8 MPa |
| Sealing Surface | Five independent 35 mm × 10 mm upper sealing blades (heated) + silicone-padded lower sealing bar |
| Heating Method | Electric resistance heating with pneumatic actuation |
| Operating Modes | Automatic and manual (foot-switch controlled) |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 2000 W |
| Dimensions (L×W×H) | 730 × 400 × 535 mm |
| Weight | 35.6 kg |
| Air Source Requirement | Compressed air (recommended: 2.5 HP, 8 bar output) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBB-FA |
| Price Range | USD 4,200 – 7,000 |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Sealing Time Range | 0.1–999.9 s |
| Sealing Pressure Range | 0.1–0.8 MPa |
| Sealing Surface | Five independent 35 mm × 10 mm upper sealing bars + silicone-padded lower sealing bar (customizable) |
| Heating Method | Electric resistive heating with dual auto/manual control mode |
| Actuation | Pneumatic (compressed air required) |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 2000 W |
| Dimensions (L×W×H) | 730 × 400 × 535 mm |
| Weight | 35.6 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | GBB-R |
| Price | USD 3,650 (approx.) |
| Measurement Methods | Mass Flow Rate (MFR) and Volume Flow Rate (MVR) |
| MFR Range | 0–200 g/10 min |
| MVR Range | 0–41.81 cm³/10 min |
| Mass Accuracy | ±0.1 g/10 min |
| Temperature Control Range | Ambient to 300 °C |
| Temperature Stability | ±1 °C at 10 mm above die top (per ISO 1133-1) |
| Temperature Uniformity | ±1 °C (same location) |
| Displacement Resolution | 0.1 mm |
| Barrel Temperature Recovery Time | ≤4 min after loading |
| Die Dimensions | Ø2.095 ±0.005 mm × 8.000 ±0.025 mm |
| Barrel ID | Ø9.550 ±0.007 mm, L = 164 ±0.1 mm |
| Piston Diameter | Ø9.474 ±0.007 mm, L = 6.350 ±0.100 mm |
| Standard Loads | 0.325–21.6 kg (7 levels), Load Accuracy: ≤±0.5% |
| Timing Resolution | 0.1–999.9 s (auto-timed cutting) |
| Dimensions | 500 × 280 × 500 mm |
| Weight | 48 kg |
| Power | 600 W, 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GBD-L |
| Pricing | Upon Request |
| Test Range (Method A) | 50–2000 g |
| Test Range (Method B) | 300–2000 g |
| Resolution | 1 g |
| Dart Mass Accuracy | ≤0.5% |
| Dart Tip Diameter (Method A) | Φ38 ± 1 mm |
| Dart Tip Diameter (Method B) | Φ50 ± 1 mm |
| Standard Weights | 5 g, 15 g, 30 g, 45 g, 80 g, 90 g (8 pcs each) |
| Weight Step Increment | 5 g |
| Drop Height Options | 1500 mm / 660 mm |
| Specimen Clamp | Pneumatic, OD 150 mm / ID 125 mm |
| Specimen Size | 180 × 180 mm |
| Air Supply | Compressed air, 0.6–0.8 MPa |
| Air Inlet | Φ8 mm |
| Dimensions (W×D×H) | 550 × 380 × 2300 mm |
| Net Weight | 70 kg |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBD-L2 |
| Pricing | Available Upon Request |
| Measurement Methods | Method A, Method B, Single-Specimen Test |
| Test Range (Method A) | 50–2000 g |
| Test Range (Method B) | 300–2000 g |
| Single-Specimen Test Mass Options | 20 g, 25 g, 40 g, 60 g, 80 g |
| Resolution | 0.1 g |
| Dart Tip Diameter (Method A) | Φ38 mm ±1 mm |
| Dart Tip Diameter (Method B) | Φ50 mm ±1 mm |
| Weight Disc Diameter (Method A) | Φ30 mm |
| Weight Disc Diameter (Method B) | Φ45 mm |
| Method A Weights | 5 g, 15 g, 30 g, 80 g (8 pcs each), 120 g (16 pcs) |
| Method B Weights | 15 g, 45 g, 90 g (8 pcs each), 180 g (9 pcs) |
| Impact Height Options | 1500 mm / 660 mm |
| Clamp Outer Diameter | 150 mm |
| Clamp Inner Diameter | 125 mm |
| Pneumatic Supply | Compressed Air, 0.6–0.8 MPa |
| Air Hose Connector | Φ6 mm |
| Dimensions (W×D×H) | 510 mm × 440 mm × 1300 mm |
| Net Weight | 50 kg |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 75 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBD-L2A |
| Pricing | Upon Request |
| Measurement Methods | Method A, Method B, Single-Specimen Test |
| Impact Height | 1500 mm / 660 mm |
| Mass Range (Method A) | 50–2000 g |
| Mass Range (Method B) | 300–2000 g |
| Single-Specimen Mass Options | 20 g, 25 g, 40 g, 60 g, 80 g |
| Resolution | 0.1 g |
| Dart Tip Diameter (Method A) | Φ38 mm ±1 mm |
| Dart Tip Diameter (Method B) | Φ50 mm ±1 mm |
| Weight Disc Diameter (Method A) | Φ30 mm |
| Weight Disc Diameter (Method B) | Φ45 mm |
| Method A Weights | 5 g, 15 g, 30 g, 80 g (8 each), 120 g (16) |
| Method B Weights | 15 g, 45 g, 90 g (8 each), 180 g (9) |
| Clamp Outer Diameter | 150 mm |
| Clamp Inner Diameter | 125 mm |
| Pneumatic Supply | Compressed Air, 0.6–0.8 MPa |
| Air Hose Connector | Φ6 mm |
| Dimensions (W×D×H) | 510 mm × 440 mm × 1300 mm |
| Net Weight | 50 kg |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 75 W |
| Brand | GBPI |
|---|---|
| Model | GBD-S1 |
| Application | Dart impact energy measurement per GB/T 9639.1 & ASTM D1709-01 |
| Test Range | 0–6400 gf (0–18000 mN) |
| Tear Arm Length | 104 ± 1 mm |
| Initial Tear Angle | 27.5° ± 0.5° |
| Indication Error | ≤ ±0.5% of full scale (20–90% range) |
| Relative Indication Variation | ≤ 1% |
| Pneumatic Supply | 0.2–0.4 MPa (user-supplied, Φ6 mm polyurethane tubing) |
| Dimensions | 430 × 370 × 650 mm |
| Weight | 50 kg |
| Power | 100 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | GBD-S2 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 4,200 – 7,000 |
| Test Standard Compliance | GB/T 9639.1, ASTM D1709-01, GB/T 16578.2, GB/T 455, ASTM D1922, ASTM D1424, ASTM D689, ISO 6383, ISO 1974, TAPPI T414 |
| Measurement Range | 0–6400 gf (0–18000 mN) |
| Tear Pendulum Arm Length | 104 ± 1 mm |
| Initial Tear Angle | 27.5° ± 0.5° |
| Indication Error | ≤ ±0.5% of full scale (within 20–90% FS) |
| Relative Indication Variation | ≤ 1% |
| Pneumatic Supply Pressure | 0.2–0.4 MPa |
| Air Inlet Fitting | Φ6 mm polyurethane tubing |
| Dimensions (W×D×H) | 430 × 370 × 650 mm |
| Weight | 50 kg |
| Power Consumption | 100 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | GBD-S3 |
| Standard Compliance | GB/T 455, ASTM D1922, ISO 1974, TAPPI T414 |
| Test Range | 0–6400 gf (0–18000 mN) |
| Tear Arm Length | 104 ± 1 mm |
| Initial Tear Angle | 27.5° ± 0.5° |
| Indication Error | ≤ ±0.5% of full scale (20–90% range) |
| Relative Variation | ≤ 1% |
| Pneumatic Supply | 0.2–0.4 MPa (user-supplied) |
| Air Interface | Φ6 mm polyurethane tubing |
| Dimensions | 430 × 370 × 650 mm |
| Weight | 50 kg |
| Power | AC 220 V, 50 Hz, 100 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GBG-L2R |
| Quotation | Upon Request |
| Measurement Methods | Method A, Method B, Single-Specimen Test |
| Impact Height | 1500 mm / 660 mm |
| Mass Range (Method A) | 50–2000 g |
| Mass Range (Method B) | 300–2000 g |
| Single-Specimen Mass Options | 20 g, 25 g, 40 g, 60 g, 80 g |
| Resolution | 0.1 g |
| Dart Tip Diameter (Method A) | Φ38 mm ±1 mm |
| Dart Tip Diameter (Method B) | Φ50 mm ±1 mm |
| Weight Disc Diameter (Method A) | Φ30 mm |
| Weight Disc Diameter (Method B) | Φ45 mm |
| Method A Weights | 5 g, 15 g, 30 g, 80 g (8 pcs each), 120 g (16 pcs) |
| Method B Weights | 15 g, 45 g, 90 g (8 pcs each), 180 g (9 pcs) |
| Clamp Outer Diameter | 150 mm |
| Clamp Inner Diameter | 125 mm |
| Pneumatic Supply | Compressed air, 0.6–0.8 MPa |
| Air Hose Connector | Φ6 mm |
| Dimensions (W×D×H) | 510 mm × 440 mm × 1300 mm |
| Weight | 50 kg |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 75 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GBH-1-aa |
| Pricing | Upon Request |
| Load Capacity | 0–500 N (optional up to 1500 N) |
| Elongation Range | Up to 1400% |
| Force Accuracy | ±0.5% of reading (Class 0.5) |
| Test Speed | 1–500 mm/min, continuously variable |
| Displacement Accuracy | ±0.5% of reading |
| Effective Specimen Width | 30 mm (customizable to 50 mm) |
| Effective Travel Distance | 750 mm |
| Dimensions (W×D×H) | 460 × 525 × 1430 mm |
| Power Consumption | 1000 W |
| Supply Voltage | AC 220 V, 50 Hz |
| Net Weight | 86 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBK-1-aa |
| Quotation | Upon Request |
| Sample Size | ≤140 × 140 mm |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Dimensions | 320 × 400 × 260 mm |
| Power Rating | 1500 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBL-L-aa |
| Pricing | Available Upon Request |
| Force Range | 0–300 N (optional 0–500 N) |
| Elongation Capacity | up to 1400% |
| Accuracy | ±1% of reading (Class 1) |
| Test Speed | 1–500 mm/min, continuously variable |
| Displacement Accuracy | ±1% of reading |
| Effective Specimen Width | 30 mm (customizable to 50 mm) |
| Effective Travel Distance | 700 mm |
| Dimensions (W×D×H) | 475 × 460 × 1430 mm |
| Power Consumption | 300 W |
| Supply Voltage | AC 220 V, 50 Hz |
| Weight | 76.5 kg |
| Brand | GBPI |
|---|---|
| Model | GBM-D1 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Volume Range | 0–90,000 mL |
| Pressure Range | 1–1000 kPa |
| Pressure Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.5% FS |
| Test Duration | 1–1000 s |
| Dimensions (L×W×H) | 400 × 415 × 272 mm |
| Weight | ≤5 kg |
| Operating Temperature | +2 °C to +25 °C |
| Storage Temperature | −20 °C to +60 °C |
| Relative Humidity (operating) | 10–90% RH (+2–25 °C), 10–70% RH (+25–30 °C), 10–50% RH (+30–35 °C, non-condensing) |
| Ambient Pressure | 90.0–105.0 kPa |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Max. Power Consumption | 140 W |
| Input Gas Pressure | 50–1000 kPa |
| Gas Inlet Connection | 6/4 mm OD tubing |
| Gas Flow Control | Main path (auto-regulated, 0–10 L/min), Bypass (manual, 0–100 L/min) |
| Interface | 1 × USB 2.0 Type-A port |
| Compliance | ASTM F1140, ASTM F2054, ASTM F2095, ASTM F2096, ISO 11607-1, YY/T 0681.3, YY/T 0681.5, YY/T 0681.9, GB/T 17876 |
| Brand | GBPI (Guangzhou Biaoji) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GBM-D1A |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Test Volume Range | 0–90,000 mL |
| Pressure Range | 1–1000 kPa |
| Pressure Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.5% FS |
| Test Duration | 1–1000 s |
| Dimensions (L×W×H) | 400 × 415 × 272 mm |
| Weight | ≤5 kg |
| Operating Temperature | +2°C to +25°C |
| Storage Temperature | −20°C to +60°C |
| Relative Humidity (non-condensing) | 10–90% RH (2–25°C), 10–70% RH (25–30°C), 10–50% RH (30–35°C) |
| Ambient Pressure | 90.0–105.0 kPa |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Max Power Consumption | 140 W |
| Input Gas Pressure | 50–1000 kPa |
| Gas Flow Control | Main line (auto, 0–10 L/min), Bypass (manual, 0–100 L/min) |
| Interface | 1 × USB 2.0 Type-A |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GBM-D1C |
| Price | Upon Request |
| Test Volume Range | 0–90,000 mL |
| Test Duration | 1–1000 s |
| Pressure Range | 1–1000 kPa |
| Pressure Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.5% FS |
| Dimensions (L×W×H) | 400 × 415 × 272 mm |
| Weight | ≤5 kg |
| Operating Temperature | +2°C to +25°C |
| Storage Temperature | −20°C to +60°C |
| Relative Humidity (Operating) | 10–90% RH (+2°C to +25°C, non-condensing) |
| Ambient Pressure Range | 90.0–105.0 kPa |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Max. Power Consumption | 140 W |
| Input Gas Pressure | 50–1000 kPa |
| Gas Inlet Connection | 6/4 mm OD |
| Main Gas Flow Control | 0–10 L/min (automated) |
| Bypass Flow Control | 0–100 L/min (manual) |
| USB Interface | 1 × USB 2.0 Type-A |
| Compliance | ASTM F1140, ASTM F2054, ASTM F2095, ASTM F2096, ISO 11607-1, YY/T 0681.3, YY/T 0681.5, YY/T 0681.9, GB/T 17876 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic |
| Model | GBM-L2 |
| Price | USD 42,000 (FOB Guangdong) |
| Absolute Pressure Range | 0–300 kPa |
| Differential Pressure Range | ±2 kPa |
| Detection Sensitivity | 1–3 µm |
| Equilibration/Test Time | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Sensor Configuration | Dual-sensor (absolute + differential pressure) |
| Test Chamber | Custom-engineered per sample geometry |
| Dimensions (W×D×H) | 495 × 455 × 280 mm |
| Ambient Temperature | 20–30 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | ASTM F2338-09(2013), YY/T 0681.18–2020, USP <1207.2>, ASTM F2095 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | GBM-L2B |
| Absolute Pressure Range | 0–300 kPa |
| Differential Pressure Range | −2–2 kPa |
| Detection Sensitivity | 1–3 µm |
| Equilibration/Test Time | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Test Principle | Vacuum Decay Method / Pressure Decay Method |
| Compliance Standards | ASTM F2338-2009 (2013), YY/T 0681.18-2020, USP <1207.2>, ASTM F2095 |
| Brand | GBPI (Guangzhou Biaoji) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Region Classification | Domestic (China) |
| Model | GBM-L2C |
| Price | USD 42,000 (approx.) |
| Absolute Pressure Range | 0–300 kPa |
| Differential Pressure Range | −2 to +2 kPa |
| Detection Sensitivity | 1–3 µm |
| Equilibration/Test Time | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Sensor Configuration | Dual-sensor (absolute + differential pressure), dual-loop system |
| Accuracy | ±0.1% FS |
| Vacuum Pump | Imported, 3 L/s pumping speed, ≤50 dB(A), high ultimate vacuum |
| Mass Flow Controller | UK-sourced, resolution 0.001 mL/min |
| Control Interface | 11″ color capacitive touchscreen |
| Compliance | ASTM F2338-09(2013), YY/T 0681.18–2020, USP <1207.2>, ASTM F2095 |
| GMP Alignment | Audit trail, multi-level user permissions, 21 CFR Part 11–ready data integrity architecture |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | GBM-L2K |
| Price | USD 53,000 (FOB Guangzhou) |
| Test Principle | Vacuum Decay / Positive Pressure Decay |
| Compliance | ASTM F2338-2009(2013), YY/T 0681.18-2020, USP <1207.2>, ASTM F2095 |
| Absolute Pressure Range | 0–300 kPa |
| Differential Pressure Range | ±2 kPa |
| Detection Sensitivity | 1–3 µm (rigid containers) |
| Repeatability | ≤0.8% RSD |
| Balance/Test Time | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Sensor Accuracy | ±0.1% FS (absolute & differential) |
| Vacuum Pump | Imported, 3 L/s pumping speed, ≤50 dB(A), high ultimate vacuum |
| Mass Flow Controller | UK-sourced, resolution 0.001 mL/min |
| Touch Interface | 11-inch industrial-grade capacitive touchscreen |
| Data Integrity | Audit trail, multi-level user permissions, compliant with GMP Annex “Computerized Systems” and FDA 21 CFR Part 11 expectations |
| Test Chamber | Custom-engineered per container geometry (vials, ampoules, syringes, IV bags, HDPE bottles) |
| Operating Environment | 20–30 °C, ≤80% RH non-condensing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 495 × 455 × 280 mm |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBM-L2M |
| Price | USD 42,000 (FOB Guangzhou) |
| Absolute Pressure Range | 0–300 kPa |
| Differential Pressure Range | −2 to +2 kPa |
| Detection Sensitivity | 1–3 µm |
| Equilibration/Test Time | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Sensor Configuration | Dual-sensor (absolute + differential pressure) / Dual-loop testing system |
| Chamber | Custom-engineered per sample geometry |
| Test Principles | Vacuum Decay Method & Pressure Decay Method |
| Compliance Standards | ASTM F2338-2009(2013), YY/T 0681.18-2020, USP <1207.2>, ASTM F2095 |
| Dimensions (W×D×H) | 495 × 455 × 280 mm |
| Ambient Temp | 20–30 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | GBM-L2T |
| Key Specifications | Absolute Pressure Range: 0–300 kPa |
| Differential Pressure Range | −2 to +2 kPa |
| Detection Sensitivity | 1–3 µm |
| Equilibration/Test Time | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Sensor Configuration | Dual-sensor (absolute + differential pressure) |
| Test Chamber | Custom-engineered per sample geometry |
| Compliance Standards | ASTM F2338-2009(2013), YY/T 0681.18-2020, USP <1207.2>, ASTM F2095 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GBM-L2V |
| Price | USD 53,000 (FOB) |
| Test Principle | Vacuum Decay & Pressure Decay Methods |
| Compliance | ASTM F2338-2009(2013), YY/T 0681.18–2020, USP <1207.2>, ASTM F2095 |
| Absolute Pressure Range | 0–300 kPa |
| Differential Pressure Range | −2 to +2 kPa |
| Detection Sensitivity | 1–3 µm |
| Equilibration/Testing Time | 1–3600 s |
| Vacuum Purge Time | 1–3600 s |
| Set Flow Rate | 0–3 mL/min |
| Sensor Accuracy | ±0.1% FS |
| Vacuum Pump | Imported, 3 L/s, ≤50 dB(A), High Ultimate Vacuum |
| Mass Flow Controller | UK-made, Resolution 0.001 mL/min |
| Control Interface | 11″ Color Touchscreen |
| Data Integrity | Audit Trail, Multi-level User Permissions, 21 CFR Part 11–Ready |
| Chamber | Customizable per Sample Geometry |
| Dimensions (W×D×H) | 495 × 455 × 280 mm |
| Ambient Temp | 20–30 °C |
| RH | ≤80%, Non-condensing |
| Power | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | GBN-200A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Quotation | Upon Request |
| Test Range | 0–3000 N (optional) |
| Stroke | 0–135 mm |
| Effective Test Area | 500 mm × 400 mm |
| Test Speed | 0–500 mm/min (infinitely variable) |
| Dimensions (W×D×H) | 400 mm × 260 mm × 550 mm |
| Power Rating | 1000 W |
| Supply | AC 220 V, 50 Hz |