| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported Laboratory Instrument |
| Model | SB+2 |
| Application Scope | Lubricating Oil & Low-Temperature Fluid Characterization |
| Compliance Standards | ASTM D5133, D7110, D2983, D4684, D445, D97, D2500 |
| Temperature Range | +30 °C to –70 °C |
| Temperature Control Accuracy | ±0.1 °C (programmed), ±0.03 °C (manual) |
| Cooling Rate | 1 °C/h (for Brookfield Scan/Gel Index), Isothermal for Brotz–Feldt Viscosity |
| Bath Medium | Methanol (temperature-dependent) |
| Dimensions (W×D×H) | 48 × 61 × 69 cm |
| Net Weight | ~86 kg |
| Power Supply | 220 VAC, 50/60 Hz |
| Safety Certifications | CE |
| Transport Weight (Bath Unit) | ~123 kg |
| Transport Dimensions (Bath Unit) | 66 × 59 × 122 cm |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TS |
| Detection Principle | Combustion Microcoulometry |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur (S) |
| Measurement Range | 0.0020–500 mg absolute sulfur |
| Detection Limit | 0.020 mg/L |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D3229, ASTM D5453, ASTM D7039, ISO 20846, ISO 20884, IP 512, UOP 97, EN ISO 20846, SH/T 0689 |
| Brand | Teledyne CETAC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model Series | CETAC Nebulizer Systems |
| Pricing | Available Upon Request |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TTech-CQG-1 |
| Price Range | USD 150–300 (FOB) |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TTech-UL94 |
| Price Range | USD 150–300 (FOB) |
| Standards Compliance | UL 94, IEC 60695-11-10, IEC 60707, GB/T 2408, GB 9493, GB/T 8332–2008, ISO 9772, ISO 1210 |
| Chamber Dimensions | 1200 mm (L) × 600 mm (W) × 1300 mm (H) |
| Burner | US-sourced Bunsen burner, tube length 100 ± 10 mm, inner diameter 9.5 ± 0.3 mm |
| Flame Height Adjustment | Stainless steel scale with 304 SS sample holder |
| Gas Flow Control | Precision needle valve + rotameter |
| Air Intake | Adjustable air inlet on burner body |
| Pressure Regulation | High-accuracy pressure regulator and gauge (0–0.4 MPa) |
| Control System | 7-inch programmable touchscreen HMI with PLC logic |
| Calculated Output | Linear burning rate (V), auto-computed and logged |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TTech-UL9540A-4 |
| Price Range | USD 1,400 – 2,800 (FOB) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2750 |
| Measurement Principle | Capacitive TPM Sensing |
| Temperature Range | +40 to +200 °C |
| TPM Range | 0.0–40.0 % TPM |
| TPM Accuracy | ±2 % TPM (at +40 to +190 °C) |
| Temperature Accuracy | ±1.5 °C |
| Resolution | 0.5 % TPM / 0.1 °C |
| Response Time | ~30 s |
| Weight | 255 g |
| Dimensions (L×W×H) | 170 × 50 × 300 mm |
| Probe Diameter | 11 mm |
| Probe Tip Length | 35 mm |
| Housing Material | Glass-fiber-reinforced ABS/ABS-PC |
| Battery | 1.5 V AAA (LR03), ~25 h runtime |
| Display | 2-line LCD with tri-color backlight (green/yellow/red) |
| Operating Humidity | 0–90 % RH |
| Storage Temp | −20 to +70 °C |
| Brand | Tianhe (Shandong Tianhe Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TH-ZW216 |
| Price | USD 4,200 (approx. based on ¥30,000) |
| Sample Capacity | 16 × 0.2 mL tubes or 8-tube strips |
| Reaction Volume | 5–120 µL |
| Temperature Range | 4–99 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.1 °C |
| Max. Heating Rate | 7 °C/s |
| Max. Cooling Rate | 5 °C/s |
| Optical Excitation Range | 400–700 nm |
| Detection Channels | 2 (FAM/SYBR Green I and VIC/HEX) |
| Data Acquisition | Full-plate capture in 3 s |
| Thermal Control | Peltier-based with PT1000 sensor and resistive edge compensation |
| Noise Level | <45 dB |
| Touch Interface | Capacitive touchscreen |
| Heat Lid | Auto-pressure-adjusting thermal lid |
| Software | Integrated qPCR analysis suite supporting standard curve quantification, melt curve analysis, ΔΔCt, multi-channel overlay, and baseline/noise threshold adjustment |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Arena 20XT |
| Instrument Category | Beverage & Food-Specific Analyzer |
| Detection Throughput | Up to 250 tests/hour |
| Sample Capacity | 84 positions |
| Refrigerated Reagent Positions | 35 |
| Wavelength Range | 340–880 nm |
| Incubation Slots / Tests per Run | 6 slots / 72 tests |
| Sample Cup Format | Disposable 12-well multi-cuvette strips (up to 50 strips = 600 tests) |
| Onboard Barcode Reader | Yes |
| Reagent Management | Ready-to-use kits with real-time reagent level monitoring |
| Liquid Handling | Fully automated sample/reagent dispensing with dual-wall washing |
| Dilution Capability | Integrated automatic pre-dilution and secondary dilution |
| Water Consumption | <1.0 L/h (internal reservoir-fed, no plumbing required) |
| Incubation Temperature Control | Adjustable |
| Stirring | Independent stirrer rods with dedicated wash station |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Arena20 |
| Instrument Category | Beverage & Food-Specific Analyzer |
| Optical Range | 275–700 nm |
| Reaction Volume | Microliter-scale (sample + reagent) |
| Detection Methodology | Photometric (absorbance), Enzymatic Assay, and Bitterness Unit (BU) Quantification |
| Sample Throughput | Random-access, on-demand analysis with variable throughput configurations |
| System Architecture | Open-platform, user-programmable method environment |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Arena30 |
| Instrument Type | Beverage & Food Biochemical Analyzer |
| Throughput | Up to 300 tests/hour |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 84 positions (including 20 calibrator + 19 control positions) |
| Reagent Capacity | 45 refrigerated positions |
| Cuvette Format | Disposable 12-well multi-cuvette strips (up to 50 strips = 600 tests) |
| Incubation Stations | 6 positions / 72 total incubation slots |
| Dilution Capability | Onboard primary and secondary auto-dilution |
| Barcode Reader | Integrated |
| Water Consumption | <1.5 L/h (internal reservoir-fed, no plumbing required) |
| Software | Open-method platform with customizable protocols, reagents, and assay parameters |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Arena60 |
| Instrument Type | Beverage & Food Biochemical Analyzer |
| Throughput | Up to 600 tests/hour |
| Wavelength Range | 340–880 nm |
| Sample Positions | 84 (including 20 calibrator + 19 control positions) |
| Refrigerated Reagent Positions | 45 |
| Incubation Capacity | 20 cuvettes per cycle, 240 tests per incubation batch |
| Multiwell Cuvette Capacity | 175 strips (2100 total tests) |
| Onboard Operation Time | Up to 4 hours |
| Dilution Capability | Integrated primary and secondary auto-dilution |
| Water Consumption | <2.0 L/h |
| Barcode Reader | Built-in |
| Reagent Management | Real-time reagent volume monitoring |
| Cuvette Type | Disposable multi-cuvette strips (low-volume, cross-contamination-free) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Gallery Beermaster |
| Instrument Category | Alcoholic Beverage and Beverage Analyzer |
| Detection Principle | Photometric (Colorimetric), Enzymatic, and Iso-Alpha Acid Extraction-Based Bitterness (IBU) Analysis |
| Wavelength Range | 275–775 nm |
| Reaction Volume | Microliter-scale (≤100 µL total per assay) |
| Sample Throughput | Random-access, high-volume batch processing |
| Cell Type | Disposable, multi-cuvette, discrete cuvettes |
| Dilution Capability | Automated primary and secondary dilution |
| Blank Correction | Multiple built-in blank reading modes (reagent blank, sample blank, dual-blank) |
| Software Compliance | Audit trail, user access control, method versioning — supports GLP/GMP documentation requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Laboratory-Scale Twin-Screw Extruder |
| Model | Eurolab 16 |
| Screw Diameter | 16 mm |
| L/D Ratio | 25:1 to 40:1 (modular) |
| Motor Power | 1.25 kW or 2.5 kW |
| Speed Range | 50–1000 rpm |
| Max Operating Pressure | 200 bar |
| Barrel Temperature Zones | 6–10 |
| Max Barrel Temperature | 350 °C (optional 450 °C) |
| Throughput | 0.5–5 kg/h |
| Drive System | PLC-controlled servo motor with real-time torque & temperature monitoring |
| Control Interface | Color LCD touchscreen with embedded HAAKE PolyLab software |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | MiniJet Pro |
| Maximum Injection Pressure | 1200 bar |
| Compressed Air Supply Pressure (Max) | 10 bar |
| Barrel Temperature Range | Up to 400 °C |
| Mold Temperature Range | Up to 250 °C |
| Sample Mass Capacity | 3–5 g per shot |
| Control Interface | Digital LCD Controller with Parameter Storage |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Process 11 |
| Drive Motor Power | 1.5 kW |
| Screw Diameter | 11 mm |
| L/D Ratio | 40 |
| Speed Range | 10–1000 rpm |
| Barrel Material | Nitrided Steel 1.7365 (EN 40B) |
| Max Operating Temperature | 350 °C (optional 450 °C) |
| Max System Pressure | 100 bar (with pressure monitoring) |
| Heating Zones | 7 × 5D electric heating (optional water cooling) |
| Dimensions (L×W×H) | 820 × 480 × 410 mm |
| Weight | 55 kg |
| Sample Requirement | ~20 g |
| Throughput | up to 2.5 kg/h |
| Barrel Opening | Horizontal split, two-piece design |
| Control Interface | Integrated color touchscreen |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | TSE 24 |
| Price | Upon Request |
| Screw Diameter | 24 mm |
| L/D Ratio | up to 40:1 |
| Motor Power | 5.5–11 kW |
| Max Speed | 500–1000 rpm |
| Max Temperature | 400 °C |
| Max Pressure | 100 bar |
| Temperature Zones | 7–10 independently controlled |
| Throughput | 2–30 kg/h |
| Drive Type | DC or AC servo motor |
| Barrel Construction | Horizontal split, hinged modular segments |
| Screw Design | Intermeshing co-rotating, fully configurable |
| Control Interface | 10.4" color touchscreen with HAAKE PolyLab OS software |
| Data Export | Real-time CSV/Excel export via Ethernet/USB |
| Compliance | CE, ISO 9001, compliant with GLP/GMP documentation requirements for process development |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory-Scale Twin-Screw Extruder |
| Model | Pharma 11 |
| Minimum Throughput | 20 g/h |
| Maximum Throughput (GMP Mode) | 2.5 kg/h |
| Application Scope | Preclinical Formulation Development, Clinical Trial Material (CTM) Manufacturing, Scale-Up Studies |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Pharma 16 |
| Price | Upon Request |
| Screw Diameter | 15.6 mm |
| Barrel Diameter | 16 mm |
| L/D Ratio | 25:1 to 40:1 (modular) |
| Motor Power | 2.5 kW |
| Max Screw Speed | 1000 rpm |
| Free Volume | 6–109 cm³ |
| Voltage/Phase/Current | 400 V / 3-phase / 20 A |
| Throughput | 1–5 kg/h |
| Barrel Material | Pharmaceutical-grade stainless steel (e.g., AISI 316L) |
| Drive | Brushless AC inverter motor |
| Control System | Touchscreen HMI with PLC-based data acquisition |
| Compliance | Designed per EU GMP Annex 1 & ICH Q5A/Q5C principles |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Pharma 24 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | Pharma Mini |
| Motor Power | 400 W |
| Speed Range | 10–360 rpm |
| Screw Configuration | Conical Co-rotating or Counter-rotating |
| Max Operating Temperature | 280 °C |
| Heating Time (22–170 °C) | < 10 min |
| Free Volume | 3 g (4 mL) |
| Screw Material | Medical-Grade Stainless Steel 1.4112 (AISI 440B) |
| Barrel Material | High-Performance Pharmaceutical-Grade Stainless Steel M340 |
| IP Rating | IP54 |
| Production Capacity | Up to 100 g/h |
| Controller | Touchscreen with User-Level Access Control and Password Protection |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F85930 |
| Pricing | Upon Request |
| Brand | TAMASAKI (Kyoto) |
|---|---|
| Origin | Japan |
| Model | M6×1.0 GP2-DS2 |
| Thread Type | Metric ISO/JIS General Purpose (M), Pitch: 1.0 mm |
| Class | JIS B 1341 Grade 2 (equivalent to ISO 965-3 Class 2H/2G) |
| Nominal Size | M6×1.0 |
| Gage Body Material | Gauge Steel (SUJ2 hardened and stabilized) |
| Sleeve Material | Anodized Aluminum Alloy |
| Mass | 27.7 g |
| Compliance | JIS B 1341, ISO 965-3, ISO 1502 |
| Application Scope | In-process verification of threaded holes in semiconductor packaging substrates, printed electronics interconnect components, and fine-pitch SMT fixture hardware |
| Brand | THT |
|---|---|
| Origin | United Kingdom |
| Model | ES-ARC |
| Compliance | ASTM E698, ISO 22517, UN Test Series 3 (H.2, H.3), IEC 60079-10-1 |
| Temperature Range | Ambient to 500 °C |
| Pressure Rating | Up to 200 bar |
| Sample Mass Capacity | 0.1–10 g |
| Heat Flow Resolution | <0.1 mW |
| Adiabatic Tracking Accuracy | ±0.02 °C/min |
| Data Acquisition Rate | 1 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 106 |
| Pricing | Upon Request |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | ProTear |
| Measurement Principle | Elmendorf Pendulum Tear Method |
| Compliance Standards | ASTM D1922, D1424, D295, D751 |
| Display | 4-line × 16-character LCD, multi-angle viewing |
| Accuracy | ±0.2% of pendulum capacity |
| Sample ID Input | 13-character alphanumeric |
| Data Storage | Up to 99 test results |
| Statistical Functions | Mean, Std. Deviation, Min/Max, Variance |
| Units | gf, lbf, mN, % of pendulum capacity |
| Fixture | Pneumatically actuated clamping |
| Pendulum Release | Pneumatic |
| Power Supply | 220–230 V ±10%, 50 Hz |
| Power Consumption | ≤10 W |
| Dimensions (L×W×D) | 578 × 483 × 398 mm |
| Operating Temp. | 10–50 °C |
| Storage Temp. | −25–70 °C |
| Sample Compatibility | Paper, board, film, foil, nonwovens, coated fabrics, packaging laminates |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-10 |
| Sealing Temperature Range | 20–400 °C (±0.15 °C accuracy) |
| Temperature Resolution | ±0.1 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 100 ms–99 s |
| Time Resolution | 10 ms |
| Time Accuracy | ±1 ms |
| Time Repeatability | ±2 ms |
| Dual Load Cells (Left/Right) | 362 kg (1000 lbf) total capacity, ±0.09 kg (±0.2 lbf) accuracy & repeatability |
| Peel Load Cell | 11.34 kg (25 lbf), 0.1% FS accuracy, ASTM E-4 calibrated |
| Seal Jaw Length Options | 50.8 mm (2 in) for hot tack or 127 mm (5 in) with auto-feed turntable |
| Jaw Width Range | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Configurations | Flat, Grooved, Custom, or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended 90 psi), integrated pressure switch |
| Dimensions (W×D×H) | 584.2 × 508 × 794.2 mm |
| Weight | 79.3 kg |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-2 |
| Sealing Temperature Range | Ambient to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 200 ms–99 s (with 10 ms resolution at low load |
| Time Accuracy | ±25 ms |
| Time Repeatability | ±50 ms |
| Jaw Length | Up to 304.8 mm (12 in) |
| Jaw Width | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Options | Flat, Grooved, Custom or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended: 90 psi) |
| Dimensions (W×D×H) | 584.2 × 400 × 620 mm |
| Weight | 72.5 kg |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TE-A420 |
| Price | USD 630 (FOB) |
| Detection Range | 0–9999 RLU |
| Limit of Detection | ≤1.0 CFU/mL |
| Measurement Precision | 2×10⁻¹⁸ mol ATP |
| Background Noise | ≤2 RLU |
| Assay Time | 10 s per sample |
| Data Storage Capacity | ≥2000 records |
| Interface | USB |
| Temperature Operating Range | 5–40 °C |
| Relative Humidity Range | 20–85 % RH |
| Configurable Alert Thresholds | ≥100 user-defined limits |
| Interference Tolerance | ±5 RLU or ±5 % |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | GWF-6JA |
| Particle Detection Principle | Laser Light Obscuration (LO) |
| Measurement Channels | 20 µm, 15–25 µm, ≥25 µm, 25–50 µm, 51–100 µm, >100 µm |
| Sizing Range | 5–200 µm |
| Count Range | 0–65,535 particles per sample |
| Sample Volumes | 5 mL, 100 mL, 475 mL, 500 mL, or full-volume aspiration |
| Accuracy | ±10% of specified value |
| Relative Standard Deviation (RSD) | ≤2% (for standard latex particles ≥1500 particles/mL) |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤45 W |
| Stirring Speed | 0–2000 rpm, paddle-type, non-contact |
| Operating Temperature | 10–40 °C |
| Dimensions | 325 × 320 × 460 mm |
| Weight | 22 kg |
| Compliance | Designed to meet Chinese Pharmacopoeia (ChP) General Chapter 0903, USP <788>, and ISO 8573-1 (particulate contamination in compressed gases—adapted for liquid-phase validation) |