| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GWF-7JA |
| Pricing | Available Upon Request |
| Light Source | High-Performance Laser |
| Detection Principle | Light Obscuration (LO) |
| Sample Compatibility | Colorless & Colored Clear Liquids, Organic Solvents, Oil-Based Formulations |
| Sample Volume Range | 1–6000 mL (0.1 mL incremental step) |
| Volume Accuracy | ≤ ±0.5% (2–1000 mL) |
| Syringe Options | 5 mL, 10 mL, 25 mL |
| Flow Rate | 5–160 mL/min (user-adjustable) |
| Particle Size Channels | 2–3 µm, 3–4 µm, 4–6 µm, 5–6 µm, ≥5 µm, ≥10 µm, 15–25 µm, ≥25 µm, 25–50 µm, 51–100 µm, >100 µm, 20 µm |
| Customizable Channel Range | 1–500 µm (segmented selection) |
| Count Range | 0–999,999 particles per sample |
| Counting Accuracy | < ±5% of certified reference value |
| RSD | < 1.5% (for standard particles ≥1000 counts) |
| Coincidence Error | < 5% at 10,000 particles/mL |
| Stirring Mechanism | Frictionless Propeller-Type Agitator, 0–2000 rpm (adjustable) |
| Display | Large Backlit LCD with Multi-Channel Real-Time Data & Histogram Overlay |
| Preloaded Database | >300 USP/ChP-Listed Pharmaceuticals & Medical Devices |
| Compliance | GB 8368–2018, Chinese Pharmacopoeia (2020 Edition), ISO 21501-4, USP <788>, USP <789>, EP 2.9.19 |
| Connectivity | RS232 Interface for LIMS/Lab Platform Integration |
| Power Supply | AC 220 V ±10%, 50 Hz, <100 W |
| Operating Temperature | 10–40 °C |
| Wetted Materials | 316L Stainless Steel + PTFE (for syringe, slit, and fluidic path) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GWF-8JA |
| Pricing | Available Upon Request |
| Principle | Light Obscuration (LO) with Laser Detection |
| Compliance | Fully Aligned with Chinese Pharmacopoeia (ChP) 2020 Edition, General Chapter 0903 |
| Sample Types | Sterile Injectable Solutions, Lyophilized Powders, Concentrated Injection Solutions |
| Detection Range | 1–500 µm (Configurable Channel Segments) |
| Channel Settings | ≥2 µm, 4–6 µm, ≥5 µm, ≥8 µm, ≥10 µm, ≥12 µm, ≥25 µm, ≥100 µm |
| Count Range | 0–9,999,999 particles per sample |
| Max. Particle Concentration | <10,000 particles/mL |
| Sample Volume | 0.2–1000 mL (5 mL accuracy: ±0.5%) |
| Flow Rate | 5–80 mL/min (adjustable) |
| Measurement Accuracy | ±10% of reference value |
| Channel Resolution | >95% |
| RSD | <2% (for standard latex particles ≥1000 particles/mL) |
| Stirring Speed | 0–2000 rpm (propeller-type, frictionless, programmable) |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤100 W |
| Display | Large LCD with Chinese GUI |
| Data Handling | Onboard storage, USB export, LAN connectivity, optional integration with LIMS or ELN platforms |
| Preloaded Drug Library | >300 ChP-listed injectables |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | GWF-8JD |
| Pricing | Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GWF-8JDS |
| Pricing | Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GWF-9DW |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GWF-A1 |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | GWF-A1 |
| Pricing | Available Upon Request |
| Light Source | High-Stability Laser Diode with Optical Power Compensation Circuit |
| Sample Compatibility | Colorless & Colored Clear Liquids, Organic Solvents, Oil-Based Matrices, Weakly Acidic/Alkaline Solutions |
| Fluidic Path Materials | Imported 316L Stainless Steel & PTFE |
| Particle Size Range | 1–500 µm |
| Channel Resolution | >95% |
| Counting Accuracy | ±5% of Reference Value |
| Relative Standard Deviation (RSD) | <1.5% (for standard particles ≥1000 particles/mL) |
| Minimum Detectable Concentration | 18,000 particles/mL |
| Adjustable Sampling Volume | 0.2–1000 mL (0.1 mL resolution, accuracy <±0.5%) |
| Flow Rate Control | 5–80 mL/min (programmable) |
| Stirring Speed | 0–1000 rpm |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz, <80 W |
| Data Interfaces | RS232, USB Storage, Thermal Printer Port |
| Software Platform | Embedded Android OS with Multi-Tier User Authentication & Audit Trail Support |
| Calibration Standards | USP <788>, USP <789>, ChP (Chinese Pharmacopoeia) Vol. IV, ISO 21510, EP 2.9.19 |
| Data Storage | Local SQLite Database with Statistical Analysis Engine |
| Compliance Features | Electronic Signature Support, User Access Logs, Data Integrity Controls per ALCOA+ Principles |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GWF-A2 |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30C |
| Measurement Principle | Freezing Point Depression |
| Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Test Time | < 2 min |
| Pre-cooling Time | ≤ 3 min |
| Resolution | 1 mOsmol/kg |
| Repeatability | RSD ≤ ±1% (at 300 mOsmol/kg) |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg), ±1% (>400 mOsmol/kg) |
| Linearity | < 1% deviation from linear fit |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 5–80% RH |
| Power Supply | AC 220 V ±10%, 80 W |
| Regulatory Status | Certified Medical Device per Chinese NMPA Class II requirements |
| Compliance | Meets pharmacopoeial specifications in Chinese Pharmacopoeia (2020 Edition), including for injectables, ophthalmic preparations, and osmotic diuretics |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30C-1 |
| Measurement Principle | Freezing Point Depression |
| Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–70 µL |
| Test Time | < 2 min |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% (at 300 mOsmol/kg) |
| Accuracy | ±2 mOsmol/kg (≤ 400 mOsmol/kg) |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Ambient Temp. | 10–30 °C |
| Ambient Humidity | 5–80% RH |
| Power Supply | AC 220 V ±10%, 80 W |
| Dimensions | 220 × 210 × 360 mm |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30D |
| Measurement Principle | Freezing Point Depression |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Analysis Time | < 90 s |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg) |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Operating Environment | 10–30 °C, 5–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, <80 W |
| Compliance Support | Chinese Pharmacopoeia (ChP) injection database built-in |
| Data Interface | RS232 |
| Software Features | User permission management, audit-trail-capable data storage, configurable pass/fail criteria, multi-format print output |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30DS |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Analysis Time | < 1.5 min |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FD |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Capacity | 1–20 positions |
| Sample Volume | 60 µL (50–100 µL typical) |
| Test Time | < 1.5 min per sample |
| Pre-cooling Time | ≤ 3 min |
| Resolution | 1 mOsmol/kg |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg) |
| Linearity | < 1% deviation from linear fit |
| Operating Environment | 5–35°C, 5–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, <80 W |
| Dimensions | 280 × 443 × 434 mm |
| Language Support | English & Chinese |
| Connectivity | RS232, USB, Barcode Scanner Interface |
| Compliance | Designed to support pharmacopeial testing per Chinese Pharmacopoeia (ChP) requirements |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FS |
| Measurement Principle | Freezing Point Depression |
| Temperature Control System | Dual-stage Peltier Cooling |
| Sample Volume | 50–100 µL |
| Calibration | Multi-point, User-defined Calibration Curves |
| Operating System | Android-based Embedded OS |
| Data Storage | Internal SSD with >100,000 Test Record Capacity |
| Compliance Features | Audit Trail, Electronic Signature (21 CFR Part 11 Ready), Role-Based Access Control |
| Connectivity | RS232, USB Host (for keyboard/mouse/scanner), Built-in Thermal Printer |
| Noise Level | <45 dB(A) |
| Pharmacopeia Integration | Preloaded Chinese Pharmacopoeia (ChP) Monographs for >300 Injectable Products |
| Maintenance | Dry-Cooling Architecture (No Heat Transfer Fluid Required) |
| Brand | Tianhe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TH-ZW108 |
| Price | USD 3,650 (approx.) |
| Sample Capacity | 8 × 0.2 mL tubes |
| Reaction Volume | 5–120 µL |
| Temperature Range | 4–99 °C |
| Max. Heating Rate | 7 °C/s |
| Max. Cooling Rate | 5 °C/s |
| Temp. Uniformity | ≤ ±0.2 °C |
| Temp. Accuracy | ≤ ±0.1 °C |
| Detection Channels | 1 (FAM/SYBR Green I) |
| Excitation Wavelength | 400–700 nm |
| Detection Method | LED excitation + imported photodetector |
| Screen | 7-inch HD capacitive touchscreen |
| Dimensions (L×W×H) | 355 × 200 × 124 mm |
| Weight | 2.5 kg |
| Noise Level | <45 dB |
| Thermal Lid | Auto-pressure-adjusting |
| Data Interface | USB port for import/export |
| Software | Integrated qPCR analysis suite with real-time curve plotting, automatic positive/negative call, GLP-compliant audit trail logging |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | YB-2A |
| Light Source | 20 W tri-phosphor fluorescent lamp with electronic ballast |
| Illuminance Range | 1000–6000 lx |
| Timing Range | 1–79 s (adjustable) |
| Power Consumption | 30 W |
| Digital Illuminance Meter | Integrated, direct-read, stable output |
| Visual Inspection System | Single-sided, operator-optimized optical path with anti-glare and flicker-free illumination |
| Compliance | Designed per Chinese Ministry of Health Standard WB1-362(B-121)-91 for clarity testing of injectables and large-volume parenterals |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | ZRS-8G |
| Instrument Type | Offline Dissolution Tester |
| Number of Vessels | 6 |
| Temperature Range | 5.0 °C (ambient) to 45.0 °C |
| Temperature Accuracy | ≤ ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Rotational Speed Range | 25–200 rpm |
| Speed Resolution | 1 rpm |
| Speed Stability Error | ≤ ±4% |
| Paddle Wobble Amplitude | ≤ 0.5 mm |
| Basket Wobble Amplitude | ≤ 1.0 mm |
| Shaft-to-Vessel Axis Offset | ≤ 2.0 mm |
| Timer Duration | Up to 99 h 59 min (forward count) |
| Sampling Cycles | Up to 9 programmable cycles |
| Sampling Interval per Cycle | Up to 9 h 59 min (countdown) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | TY-ATP |
| Detection Range | 0–99,999 RLU |
| Detection Time | 15 s |
| Sensitivity | 1×10⁻¹⁸ mol ATP |
| Display | 3.5-inch capacitive touch LCD |
| Processor | 32-bit high-speed microcontroller |
| Accuracy | ±5 RLU or ±5% |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–85% RH |
| ATP Recovery Rate | 90–110% |
| Detection Modes | RLU, Coliform Screening |
| Auto Pass/Fail Judgment | Yes |
| Data Interface | Mini-USB |
| Power | Rechargeable Li-ion battery (6-month standby at 20 °C) |
| Dimensions (W×H×D) | 188 × 77 × 37 mm |
| Weight | ~280 g |
| Compliance | Designed for ISO 22000, HACCP, and FDA Food Code-aligned hygiene verification workflows |
| Brand | Tianyan |
|---|---|
| Model | TY-BZQ |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range | 500 N (optional: 100 N / 500 N / 1000 N) |
| Resolution | 0.01 N |
| Accuracy | ±0.5% FS |
| Test Speed | 1–300 mm/min |
| Upper Platen Diameter | 10 mm |
| Lower Platen Diameter | 100 mm |
| Parallelism Between Platens | <0.025 mm |
| Dimensions (W×D×H) | 450 × 450 × 680 mm |
| Weight | 45 kg |
| Power Supply | 220 V, 50 Hz |
| Standard Configuration | Mainframe, Fixture Set, Thermal Microprinter, Touchscreen Control Software |
| Optional | PC with Dedicated Software, Inkjet Printer, Automated Feeding System |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Model | TY-CHY |
| Measurement Range | 0–5 mm (customizable fixtures available) |
| Measuring Pressure | 17.5 ± 1 kPa (for films), 50 ± 1 kPa (for paper) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Class of Accuracy | Grade 0.5 |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions | 450 × 340 × 390 mm |
| Weight | 30 kg |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 6672-2001, GB/T 451.3-2002, GB/T 6547-1998, ISO 4593:1993, ISO 534:2011, ISO 3034:2011, ASTM D374-1999, ASTM D1777-1996 (2007), JIS K6250-1997, JIS K6783-1994, JIS Z1702-1994, BS 3983-1989, BS 4817, TAPPI T411 |
| Interface | RS232 serial port |
| Optional Accessories | Auto-sampler unit, PC-based analysis software, calibration weights, communication cable |
| Brand | Tianyan |
|---|---|
| Model | TY-FK100 / FK200 / FK300 / FK400 / FK500 |
| Origin | Shandong, China |
| Power Supply | 220 V AC, 50 Hz |
| Max. Power | 500 W |
| Sealing Speed | 10 m/min |
| Sealing Width | 12 mm |
| Temperature Range | 60–220 °C (±1% control accuracy) |
| Sealing Margin Adjustment | 0–35 mm |
| Display | 7-inch color touchscreen (GUI, bilingual Chinese/English, text-to-speech support) |
| Print Capability | Dual-line dot-matrix printing (reversible 180°), customizable font width, selective field suppression, intelligent bag-width matching logic |
| Data Storage | >10 million records |
| Compliance | YY/T 0698.5–2009 (seal strength), YY 0466–2003 (medical device symbols) |
| Enclosure Options | Powder-coated carbon steel or 304 stainless steel |
| Dimensions | 620 × 270 × 220 mm |
| Weight | 20 kg |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-FSX |
| Detection Range | 1 µm – 10 mm |
| Imaging Resolution | 2592 × 1944 (5 MP CMOS camera) |
| Optical Magnification | 100× |
| Image Size Options | 640×480, 1024×768, 2048×1536, 2592×1944 |
| Power Supply | 220 V / 2 A / 50 Hz |
| Compliance | GB/T 6030–2006 |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-GA1. |
| Function Type | Multi-parameter (simultaneous detection of up to 200 food safety analytes) |
| Sample Compatibility | Universal for liquid, extract, and homogenized solid food matrices |
| Detection Time | ≤3 minutes per batch |
| Detection Channels | 12 independent optical channels |
| Display | 10.1-inch vertical capacitive touch LCD (Android OS) |
| Main Controller | ARM Cortex-A7 + RK3288 quad-core CPU (1.88 GHz) |
| Light Source | Imported precision cold LED source with four fixed wavelengths (410 nm, 520 nm, 590 nm, 630 nm) |
| Optical Design | Precision rotating cuvette holder with inter-channel calibration uniformity ≤0.1% |
| Connectivity | Dual-band Wi-Fi (2.4/5 GHz), optional 4G LTE (APN-enabled), Bluetooth 4.2, dual USB 2.0 ports, RJ45 Ethernet |
| Power Supply | AC/DC dual-mode |
| Data Storage | Internal flash ≥16 GB + USB mass storage support |
| Dimensions (L×W×H) | 440 × 300 × 180 mm |
| Compliance | Designed to support ISO/IEC 17025 laboratory practices, aligned with GB 5009.x series, GB/T 5009.x, and SN/T standards for food testing |
| Brand | Tianyan |
|---|---|
| Model | TY-HA01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Height Measurement Range | 0.00–11.00 mm |
| Resolution | 0.01 mm |
| Mass Measurement Range | 0–200 g |
| Mass Resolution | 0.01 g |
| Dimensions (L×W×H) | 400 × 300 × 180 mm |
| Display | Digital LCD |
| Software Integration | Embedded Hough Unit calculation algorithm per USDA AMS standards |
| Brand | Tianyan |
|---|---|
| Model | TY-HRD |
| Origin | Shandong, China |
| Temperature Range | 0–1600 °C (±3 °C accuracy) |
| Resolution | 1 °C (temperature), 1 min (time |
| Heating Rate | 15–20 °C/min up to 900 °C |
| Thermocouple Type | S-type (Platinum-Rhodium/Platinum) |
| Max Control Current | 30 A |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 10 W |
| Dimensions (W×H×D) | 305×390×120 mm |
| Operating Environment | 0–40 °C, RH ≤80% |
| Communication Interface | RS232 |
| Compliance | GB/T 219–2008 (Chinese National Standard for Coal Ash Fusibility) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TY-L01G |
| Detection Principle | Competitive Inhibition Immunoassay with Colloidal Gold Lateral Flow |
| Sample Throughput | Up to 12 tests per run |
| Display | 10.1-inch capacitive touchscreen (Android OS) |
| Processor | ARM Cortex-A7 RK3288, quad-core @ 1.88 GHz |
| Power Supply | AC/DC adapter + built-in 6 Ah Li-ion battery (field-deployable) |
| Dimensions | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Data Storage | >200,000 records (local USB export to Excel) |
| Connectivity | Wi-Fi, RJ45 Ethernet, optional A4 thermal printer interface |
| Compliance Support | FDA 21 CFR Part 11–ready audit trail (user login, permission tiers, calibration lock), GLP/GMP-aligned data management |
| Brand | Tianyan (Shandong) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-NY1 2C |
| Price Range | USD 175 – 1,100 (FOB) |
| Detection Method | Enzyme Inhibition Assay (Spectrophotometric Measurement at 410 nm) |
| Number of Channels | 12 |
| Wavelength | 410 nm |
| Inhibition Rate Range | 0–100% |
| Inhibition Rate Accuracy | ≤ ±10% |
| Inhibition Rate Repeatability | ≤ 5% |
| Transmittance Accuracy | ±1.5% |
| Transmittance Repeatability | ≤ 0.5% |
| Absorbance Drift | ≤ 0.005 Abs / 3 min |
| Dimensions | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Power Supply | DC 12 V (with optional 6 Ah rechargeable Li-ion battery and vehicle adapter) |
| Display | 7-inch capacitive touchscreen (Android OS, ARM Cortex-A7 RK3288 quad-core @ 1.88 GHz) |
| Data Storage | 200,000 test records (exportable as Excel via USB 2.0) |
| Connectivity | Built-in Wi-Fi & wireless upload module |
| Calibration | NIM-certified (National Institute of Metrology, China) |
| Enclosure | Industrial-grade ABS polymer housing |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-SCG |
| Price Range | USD 830–1,810 (FOB) |
| Functionality | Multi-analyte Screening Platform |
| Sample Compatibility | Broad-spectrum aquatic and food matrices |
| Main Control IC | ARM Cortex-A7 |
| Detection Time | ≤ 3 minutes per test |
| Detection Channels | 12 independent lanes |
| Display | 10.1-inch capacitive touchscreen LCD |
| Detection Principle | Colloidal Gold Immunochromatographic Assay (CGIA) |
| Communication Interfaces | USB 2.0, Wi-Fi (802.11 b/g/n), RJ45 Ethernet |
| Power Supply | DC 12 V input (vehicle-compatible), integrated 6 Ah Li-ion battery |
| Data Storage | Internal flash + standard USB port for U-disk export |
| Dimensions (W×D×H) | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Processor | Rockchip RK3288 (Quad-core ARM Cortex-A17, 1.8 GHz) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-SSY-24F |
| Maximum Pressure | 0–24 metric tons (235.2 kN) |
| Piston Diameter | φ95 mm |
| Max Piston Stroke | 30 mm |
| Pressure Display Resolution | 0.01 MPa (equivalent to 0.102 ton-force) |
| Pressure Stability | ≤1 MPa per 10 minutes |
| Worktable Diameter | Φ105 mm |
| Column Spacing | 112 × 160 mm |
| Overall Dimensions | 305 × 200 × 440 mm (L×W×H) |
| Net Weight | 65 kg |
| Protective Shield | Transparent Acrylic |
| Structural Design | Monolithic Mainframe (integrated oil reservoir, baseplate, and chrome-plated cylinder |
| Hydraulic System | Filtered oil circuit, custom piston seal, extended-life tension spring (30 mm stroke retention), aluminum alloy handwheel |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TY-SuperVario-N |
| Speed Range | 600–1130 rpm |
| Temperature Control Range | Ambient to 68 °C |
| Power Supply | 230 V / 50 Hz |
| Internal Chamber Height | 370 mm |
| Overall Height | 460 mm |
| Net Weight | 26 kg |