Jilin City Beiguang Analytical Instrument Factory

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelJLBG-126U
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleFourier-transform-free Infrared Spectrophotometry (Dispersive Grating-based, Full-spectrum Scanning)
Measurement Range0 mg/L – 100% oil (w/w or v/v, matrix-dependent)
Detection Limit0.2 mg/L (as petroleum hydrocarbons in water, per HJ 637–2012 protocol with 1000 mL sample & 25 mL C₂Cl₄ extract, 4 cm pathlength)
Accuracy±10% (relative error vs. certified reference materials per HJ 637–2012 Annex B)
Resolution0.1 ppm (digital absorbance resolution at 2930 cm⁻¹)
Analysis Cycle Time75 seconds per sample (including spectral acquisition, baseline correction, and calculation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
ModelJLBG-208
Instrument TypeBenchtop Laboratory Mercury Analyzer
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Limit0.01 µg/L (differential mode), 0.1 µg/L (standard mode)
Repeatability<3% RSD at 2 µg/L
Linearity Error±10%
Correlation Coefficientγ > 0.995 (differential), γ > 0.999 (low/high concentration)
Power SupplyAC 220 V, 30 W
Operating Temperature17–30 °C
Operating Humidity20–80% RH
Dimensions (L×W×H)42×30×16 cm
Net Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
Instrument TypeLaboratory Analyzer
Measurement PrincipleInfrared Spectrophotometry (Dual-Wavelength & Triple-Wavelength Non-Dispersive Modes)
Measurement Range0.002 mg/L – 100% oil (post-extraction)
Detection Limit0.002 mg/L (by jet extraction)
Accuracy±2% at 100 mg/L
Resolution0.1 ppm (as oil in solvent)
Measurement Frequency2 measurements/minute
Wavenumber Range4000–2000 cm⁻¹ (customizable)
Wavenumber Repeatability±1 cm⁻¹
Absorbance Range (log scale)0.00000–2.00000 A
ComplianceHJ 637–2012, GB 3838–2002, GB 18918–2002, GB 18483–2001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelJLBG-129U
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleFourier Transform Infrared (FTIR) Spectrophotometry
Measurement Range0 mg/L – 100% oil (w/w or v/v, matrix-dependent)
Detection Limit0.2 mg/L (as petroleum hydrocarbons in water)
Accuracy±10% (relative error vs. certified reference materials)
Spectral Resolution0.1 ppm (mass concentration resolution at 4 cm⁻¹ spectral resolution)
Analysis Cycle Time75 seconds per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
ModelJLBG-209
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Limit0.005 µg/L
Repeatability<5% RSD
Linearity Correlation Coefficientr > 0.995
Power SupplyAC 220 V, 30 W
Operating Temperature10–30 °C
Operating Humidity<80% RH
Dimensions (L×W×H)430 × 330 × 150 mm
Net Weight7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJLBG-129
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹)
Measurement Range0.001 mg/L to 100% oil (post-extraction)
Detection Limit0.1 mg/L (oil in CCl₄, 4 cm pathlength)
Accuracy±2% at 100 mg/L
Resolution0.1 ppm (as oil)
Measurement Frequency2 samples/min
Wavenumber Range4000–2000 cm⁻¹ (customizable)
Wavenumber Repeatability±1 cm⁻¹
Absorbance Range (log scale)0.00000–2.00000 A
Correlation Coefficient (r)>0.999 (for standard oil series)
Compliant StandardsHJ 637–2012, GB 3838–2002, GB 18918–2002, GB 18483–2001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
ModelWCG-207
PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Limit (Differential Mode)0.02 µg/L
Measurement Range (Differential Mode)0.04–0.64 µg/L
Precision (RSD)<10% at 0.32 µg/L (Differential), <5% at ≥3.2 µg/L
Linearity (Correlation Coefficient)γ > 0.995 (Differential), > 0.999 (Standard Modes)
Power SupplyAC 220 V, 30 W
Operating Temperature10–30 °C
Operating Humidity<80% RH
Dimensions (L×W×H)420 × 300 × 160 mm
Net Weight15 kg
ComplianceGB 7468–1987 (Water Quality — Determination of Total Mercury — Cold Vapor Atomic Absorption Spectrophotometry)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
ModelJLBG-129+
Instrument TypeLaboratory
Measurement PrincipleInfrared Spectrophotometry
Measurement Range0 mg/L – 100% oil (w/w or v/v, matrix-dependent)
Detection Limit0.1 mg/L (as petroleum hydrocarbons in water)
Accuracy±10% (relative error vs. certified reference materials)
Resolution0.1 ppm (absorbance-based quantification)
Measurement Cycle Time75 seconds per sample
Solvent CompatibilityTetrachloroethylene (TCE) or Carbon Tetrachloride (CTC) — CTC use discouraged per Montreal Protocol and updated Chinese environmental standards (e.g., HJ 637–2012 revision)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
ModelJLBG-126+
Instrument TypeLaboratory
Measurement PrincipleInfrared Spectrophotometry
Measurement Range0 mg/L – 100% oil (w/w or v/v, matrix-dependent)
Detection Limit0.2 mg/L (as petroleum hydrocarbons in water)
Accuracy±10% (relative error vs. certified reference materials)
Resolution0.1 ppm
Measurement Cycle Time75 seconds per sample
ComplianceDesigned to meet HJ 637–2012 (China Environmental Protection Standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
ModelJDS-Q10U
Instrument TypeLaboratory-Based Oil Content Analyzer
Wavenumber Range3400–2400 cm⁻¹
Absorbance Range0.0000–1.0000 AU (Transmittance: 10–100% T)
Measurement Range0.02–100 mg/L (oil in water)
Detection Limit≤1 mg/L
Linearityr > 0.999
RepeatabilityRSD < 5% (for 30–50 mg/L samples)
Analysis Time2 min per sample
Sample Volume10–100 mL
Power Supply220 VAC ±10%, 50 Hz, 70 VA
Controller Dimensions300 × 200 × 80 mm (W×D×H), Weight: 2 kg
Main Unit Dimensions500 × 350 × 125 mm (W×D×H), Weight: 16 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
ModelCQQ-1000×3
Sample Volume1000 mL per chamber
Extraction Time<2 min
Extraction Efficiency>95%
Spike Recovery95–105%
Power Supply220 V AC, 10 VA
CapacityTriple-channel (3 independent extraction units)
ComplianceDesigned for ASTM D3764, ISO 11348, and EPA Method 1664/525.3 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang
OriginJilin, China
ModelCQQ-500×1
Sample Volume300 mL
Extraction Time<1 min
Extraction Efficiency>95%
Spike Recovery95–105%
Throughput1 sample per cycle
ComplianceDesigned for ASTM D7066 (oil in water), ISO 9377-2 (phenol in wastewater), and USP <467> residual solvent pre-treatment workflows