- All
- Favorite
- Popular
- Most rated
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA/TGA L86 |
| Instrument Type | Universal Simultaneous Thermal Analyzer |
| Temperature Range | −150 °C to 2400 °C |
| Balance Sensitivity | 0.01 µg |
| Maximum Sample Capacity | 35 g / ±20000 mg |
| Vacuum Capability | 10⁻² mbar (pump-dependent) |
| Pressure Range (optional) | up to 5 bar |
| Heating Rate | 0.01–100 K/min |
| TG Resolution Options | 0.01 µg / 0.02 µg / 0.1 µg |
| DSC Sensor Types | E, K, S, B, C (C = DTA-only) |
| DSC Resolution | 0.3–1.2 µW |
| DTA Resolution | 0.03 nV |
| DTA Sensitivity | 1.5 µV/mW |
| DTA Range | ±250 µV / ±2500 µV |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA HP L85 |
| Temperature Range | RT to 1200 °C |
| Pressure Range | up to 150 bar |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 5 g |
| Vacuum Level | 10⁻⁴ mbar |
| Heating Rate | up to 300 K/min |
| Cooling Rate | up to 150 K/min |
| TG Sensor Types | E, K, S, B, C |
| TG-DSC Sensor Types | E, K, S, B, C |
| Interface | USB or Ethernet |
| Gas Configuration | 1–3 configurable gas channels (customizable) |
| Optional Accessories | Steam Generator, H₂/HC Auto-Vent & Gas Safety System |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA L83 |
| Temperature Range | RT to 1100 °C |
| Heating/Cooling Rate | 0.001–250 °C/min |
| Maximum Sample Mass | 5 g |
| Cooling Time | <12 min (1100 °C → 100 °C) |
| Vacuum Capability | up to 10⁻³ mbar |
| Atmosphere Control | Inert, oxidative, reductive, vacuum |
| Gas Dosing | Integrated MFC module with 3 gas channels (1 purge + 2 reactive) |
| Sample Autosampler | Up to 90 positions |
| Crucible Materials | Pt, Al₂O₃, Au, Ag, Al, graphite, W, stainless steel (HP) |
| EGA Compatibility | FTIR, MS, GC-MS |
| Interface | USB |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA L81 |
| Temperature Range | –150 to 2400 °C |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 25 g |
| Vacuum Tightness | 10⁻² mbar |
| Optional DTA Calculation | Yes |
| Interface | USB |
| Compatibility | MS and/or FTIR for Evolved Gas Analysis (EGA) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TGA L87 MSB |
| Temperature Range | –196 to 2400 °C |
| Balance Sensitivity | 1 µg |
| Maximum Sample Mass | 10 g (standard balance) |
| Measurement Environment | Ultra-High Vacuum (UHV) to 150 bar (metal version) |
| Gas Analysis Compatibility | Mass Spectrometry (MS) and FTIR coupling supported |
Show next