| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DTA L61 |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | −150 °C to 2400 °C (configurable: −150–500 °C, −150–1000 °C, RT–1400 °C, RT–1500 °C, RT–1600 °C, RT–1750 °C, RT–2000 °C, RT–2400 °C) |
| Heating/Cooling Rate | 0.001–50 K/min |
| Vacuum Capability | down to 1×10⁻⁵ mbar |
| Sensor Types | E-, K-, S-, B-, and C-type thermocouples |
| Measurement Principle | Heat-Flux DTA |
| Atmosphere Control | Oxidizing, reducing, inert (static/dynamic) |
| Optional Coupling | Mass Spectrometry (MS), Fourier Transform Infrared Spectroscopy (FTIR) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Instrument Type | Differential Scanning Calorimeter |
| Model | DSC L63 |
| Temperature Range | −170 °C to 750 °C |
| Heating/Cooling Rate | 0.01–100 K/min |
| Temperature Accuracy | ±0.1 K |
| DSC Signal Range | ±750 mW |
| Sample Capacity | Up to 96 positions (with optional autosampler) |
| Data Acquisition Rate | 100 Hz |
| Enthalpy Accuracy | <1% (verified with In, Zn standards) |
| Sensor Type | Ceramic/metal hybrid high-resolution sensor |
| Gas Control | Optional MFC (3 gases) or integrated MFC |
| 炉 Body & Crucible Interchangeability | Yes |
| Compliance | ASTM E794, ISO 11357, USP <1163>, GLP-ready |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | Chip-DSC 1 (Chip-DSC L66 Basic) |
| Instrument Type | DSC |
| Temperature Range | RT to 450 °C (no active cooling unit) |
| Heating/Cooling Rate | 0.001–100 K/min |
| Temperature Accuracy | ±0.2 K |
| DSC Signal Range | ±2.5–±1000 mW |
| Temperature Repeatability | ±0.02 K |
| Heat Flow Resolution | 0.03 µW |
| Atmosphere Options | Inert or oxidative (static/dynamic) |
| Calibration | Supplied with certified reference materials |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DSC L62 |
| Instrument Type | DSC |
| Temperature Range | −150 °C to 1750 °C |
| Heating/Cooling Rate | 0.001–50 K/min |
| DSC Signal Range | ±2.5 mW to ±250 mW |
| Sensor Types | DSC, DTA, DSC–Cp |
| Thermocouple Options | E, K, S, B |
| Vacuum Capability | down to 10⁻⁵ mbar |
| Atmosphere Control | inert, oxidizing, reducing (static/dynamic) |
| Modulated Temperature Function | Yes |
| Interface | USB |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | Chip-DSC 100 (Chip-DSC L66 Ultimate) |
| Instrument Type | DSC |
| Temperature Range | −150 to 600 °C (Peltier, closed-loop internal cooler, or liquid nitrogen cooling) |
| Temperature Accuracy | ±0.2 K |
| Temperature Precision | ±0.02 K |
| Heating/Cooling Rate | 0.001–1000 K/min |
| DSC Signal Range | ±2.5–±1000 mW |
| Heat Flow Resolution | 0.03 µW |
| Atmosphere Control | Inert or oxidative (static/dynamic) |
| Recommended Calibration Interval | Every 6 months |
| Digital Imaging Resolution | 1680 megapixels (optical accessories only) |
| Power Consumption | Up to 80% lower than conventional DSC systems |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | Chip-DSC 10 (Chip-DSC L66 Advanced) |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –180 to 600 °C (with optional quench cooling) |
| Temperature Accuracy | ±0.2 K |
| Temperature Precision | ±0.02 K |
| Heating/Cooling Rate | 0.001–300 K/min (up to 500 K/min ballistic cooling from 400 °C) |
| DSC Signal Range | ±2.5 to ±1000 mW |
| Thermal Resolution | 0.03 µW |
| Digital Resolution | 16.8 million data points per trace |
| Atmosphere Options | Inert or oxidative (static/dynamic) |
| Calibration Frequency | Recommended every 6 months |
| Compliance | ASTM E794, ISO 11357-1 to -7, USP <1163>, GLP-ready audit trail support |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DSC L64 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −50 to 160 °C (standard) |
| Heating/Cooling Rate | 0.001–10 K/min (standard) |
| Temperature Accuracy | ±100 µ°C |
| Sensitivity | 550 µV/mW (25 °C) |
| Sample Volume | 5–100 µL (standard) |
| Sensor Technology | Patented high-sensitivity thermopile-based sensor with direct sample temperature measurement and Joule-effect calibration |
| Sample Holder | Removable, hermetically sealed crucible |
| Dimensions (W×D×H) | 900 × 700 × 500 mm (standard) |