Empowering Scientific Discovery

LINSEIS Thermal Analysis

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLINSEIS
OriginGermany
ModelSTA L87 MSB
Temperature Range–196 to 2400 °C
Max. Sample Mass10 g (standard balance)
Resolution1 µg
Pressure RangeUHV to 150 bar (metal version)
Measurement PrincipleMagnetic suspension coupling with PID-controlled electromagnetic levitation
Compliance OptionsASTM E1131, ISO 11358, USP <731>, GLP/GMP-ready data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLINSEIS
OriginGermany
ModelSTA L82
Temperature RangeRT to 1000 °C
Heating Rate0.01–100 K/min
Temperature Stability±0.001 °C
Maximum Sample Mass25 mg / 2500 mg
TG Resolution0.1 µg
DSC Sensitivity~4–17.6 µW
DTA Resolution0.03 nV
Vacuum Capability10⁻² mbar (≤800 °C)
Atmosphere ControlInert, oxidative, reducing, humidified, or vacuum
Optional Autosampler42- or 90-position
Sensor TypesE/K/S thermocouples
Measurement ModesTG, TG-DTA, TG-DSC, TG-DSC (Cp)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLINSEIS
OriginGermany
ModelSTA HP L85
Temperature Range170 °C to 1200 °C (optional 1600 °C / 1800 °C)
Temperature Stability±0.05 °C
Max Sample Mass35,000 mg
Operating Pressureup to 150 bar
TGA Resolution0.1 μg
DSC Sensitivityapprox. 4–22.5 μW
DSC Resolution0.3–1 μW
DTA Resolution0.03 nV
Vacuum Level≤10⁻⁴ mbar (pump-dependent)
Sensor TypesE / K / S / B / C
Gas ControlQuantitative mass-flow-controlled inlet systems
Optional AccessoriesSteam generator, top-loading modular sensor kits (TG-only or TG-DSC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLINSEIS
OriginGermany
ModelSTA L81 Nuclear
Temperature Range−150 °C to 500 / 700 / 1000 °C
Heating Rate0.01–100 K/min
Temperature Stability0.001 °C
Maximum Sample Mass±35,000 mg
Vacuum Capability10⁻² mbar (pump-dependent)
Pressure Range (optional)up to 5 bar
TG Resolution0.01 / 0.02 / 0.1 µg
DSC Resolution0.3 / 0.4 / 1 / 1.2 µW
DTA Resolution0.03 nV
DTA Sensitivity1.5 µV/mW
DTA Range250 / 2500 µV
Sensor TypesE / K / S / B / C (C = DTA-only)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLINSEIS
OriginGermany
ModelSTA L81
Temperature Range−150 to 2400 °C
Heating Rate0.01–100 K/min
Temperature Stability±0.001 °C
Maximum Sample Mass5 g / ±2500 mg
Atmosphere ControlVacuum (down to 10⁻² mbar), Pressure up to 5 bar (optional)
TG Resolution0.01–0.1 µg
DSC Sensor TypesE, K, S, B, C (C = DTA-only)
DSC Sensitivity~4–22.5 µW
DSC Resolution0.3–1.2 µW
DTA Sensitivity1.5 µV/mW
DTA Resolution0.03 nV
DTA Range±250–±2500 µV
Optional Autosampler42-position
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLINSEIS
OriginGermany
ModelSTA/TGA L86
Temperature Range−150 °C to 500 / 700 / 1000 °C
Heating Rate0.01–100 K/min
Temperature Stability±0.001 °C
Maximum Sample Mass35 g
TG Resolution0.01–0.1 µg
DSC Resolution0.3–1.2 µW
DTA Resolution0.03 nV
Vacuum Capability10⁻² mbar (pump-dependent)
Pressure Range (optional)up to 5 bar
Atmosphere ControlInert, oxidizing, reducing, corrosive, and vacuum-compatible
Sensor OptionsE/K/S/B/C (C-type for DTA only)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0