- All
- Favorite
- Popular
- Most rated
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L87 MSB |
| Temperature Range | –196 to 2400 °C |
| Max. Sample Mass | 10 g (standard balance) |
| Resolution | 1 µg |
| Pressure Range | UHV to 150 bar (metal version) |
| Measurement Principle | Magnetic suspension coupling with PID-controlled electromagnetic levitation |
| Compliance Options | ASTM E1131, ISO 11358, USP <731>, GLP/GMP-ready data logging |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L82 |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | ±0.001 °C |
| Maximum Sample Mass | 25 mg / 2500 mg |
| TG Resolution | 0.1 µg |
| DSC Sensitivity | ~4–17.6 µW |
| DTA Resolution | 0.03 nV |
| Vacuum Capability | 10⁻² mbar (≤800 °C) |
| Atmosphere Control | Inert, oxidative, reducing, humidified, or vacuum |
| Optional Autosampler | 42- or 90-position |
| Sensor Types | E/K/S thermocouples |
| Measurement Modes | TG, TG-DTA, TG-DSC, TG-DSC (Cp) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA HP L85 |
| Temperature Range | 170 °C to 1200 °C (optional 1600 °C / 1800 °C) |
| Temperature Stability | ±0.05 °C |
| Max Sample Mass | 35,000 mg |
| Operating Pressure | up to 150 bar |
| TGA Resolution | 0.1 μg |
| DSC Sensitivity | approx. 4–22.5 μW |
| DSC Resolution | 0.3–1 μW |
| DTA Resolution | 0.03 nV |
| Vacuum Level | ≤10⁻⁴ mbar (pump-dependent) |
| Sensor Types | E / K / S / B / C |
| Gas Control | Quantitative mass-flow-controlled inlet systems |
| Optional Accessories | Steam generator, top-loading modular sensor kits (TG-only or TG-DSC) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L81 Nuclear |
| Temperature Range | −150 °C to 500 / 700 / 1000 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | 0.001 °C |
| Maximum Sample Mass | ±35,000 mg |
| Vacuum Capability | 10⁻² mbar (pump-dependent) |
| Pressure Range (optional) | up to 5 bar |
| TG Resolution | 0.01 / 0.02 / 0.1 µg |
| DSC Resolution | 0.3 / 0.4 / 1 / 1.2 µW |
| DTA Resolution | 0.03 nV |
| DTA Sensitivity | 1.5 µV/mW |
| DTA Range | 250 / 2500 µV |
| Sensor Types | E / K / S / B / C (C = DTA-only) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L81 |
| Temperature Range | −150 to 2400 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | ±0.001 °C |
| Maximum Sample Mass | 5 g / ±2500 mg |
| Atmosphere Control | Vacuum (down to 10⁻² mbar), Pressure up to 5 bar (optional) |
| TG Resolution | 0.01–0.1 µg |
| DSC Sensor Types | E, K, S, B, C (C = DTA-only) |
| DSC Sensitivity | ~4–22.5 µW |
| DSC Resolution | 0.3–1.2 µW |
| DTA Sensitivity | 1.5 µV/mW |
| DTA Resolution | 0.03 nV |
| DTA Range | ±250–±2500 µV |
| Optional Autosampler | 42-position |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA/TGA L86 |
| Temperature Range | −150 °C to 500 / 700 / 1000 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | ±0.001 °C |
| Maximum Sample Mass | 35 g |
| TG Resolution | 0.01–0.1 µg |
| DSC Resolution | 0.3–1.2 µW |
| DTA Resolution | 0.03 nV |
| Vacuum Capability | 10⁻² mbar (pump-dependent) |
| Pressure Range (optional) | up to 5 bar |
| Atmosphere Control | Inert, oxidizing, reducing, corrosive, and vacuum-compatible |
| Sensor Options | E/K/S/B/C (C-type for DTA only) |
Show next