Mass Spectrometry Instruments
Filter
Showing 391–420 of 487 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Flash 2000HT |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Stable Gas-Source Isotope Ratio Mass Spectrometry (IRMS) Interface System |
| Analytical Precision | High-precision δ-value reproducibility (typical 1σ < 0.2‰ for δ¹³C, δ¹⁵N, δ³⁴S, δ²H, δ¹⁸O) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC IsoLink II |
| Quotation | Upon Request |
| Measurement Precision | δ¹³C < 0.2‰, δ¹⁵N < 0.5‰, δ¹⁸O < 0.8‰, δ²H < 3.0‰ |
| Measured Isotopes | ¹³C, ¹⁵N, ¹⁸O, ²H |
| Mass Range | 1–80 u |
| Resolution | 110 (10% valley) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Multi-Collector Static Vacuum Noble Gas Isotope Ratio Mass Spectrometer |
| Model | HELIX MC Plus |
| Isotopes Measured | Ne, Ar, Kr, Xe (up to 5 simultaneously) |
| Mass Range | Full noble gas isotopic range (1–132 amu) |
| Resolution | >750 (10% valley, standard receivers), >1,500 (10% valley, high-resolution receivers) |
| Detector Configuration | Faraday cups + CCD multi-collector array with configurable amplifier gains (10¹⁰ Ω, 10¹¹ Ω, 10¹² Ω, 10¹³ Ω) |
| Dynamic Range | >12 orders of magnitude (Faraday + CCD hybrid detection) |
| Application Focus | High-precision noble gas isotope ratio analysis in geochronology, cosmochemistry, nuclear forensics, and mantle geochemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rare Gas Isotope Ratio Mass Spectrometer |
| Model | HELIX SFT |
| Measurement Range | Full mass range for noble gases (He, Ne, Ar, Kr, Xe) |
| Resolution | >700 at low mass (e.g., m/z 3), enabling baseline separation of ³He from HD⁺ and H₃⁺ interferences |
| Abundance Sensitivity | <1 ppb at m/z 4 relative to m/z 3 |
| Internal Volume | ~1400 cm³ |
| Amplifier Options | 10¹⁰ Ω, 10¹¹ Ω, 10¹² Ω, and 10¹³ Ω Faraday cup amplifiers |
| Detection Modes | Simultaneous multi-collection (e.g., ³He/⁴He) and peak-jumping for full noble gas isotope systems |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iCAP MSX ICP-MS |
| Price | Upon Request |
| Application Environment | Laboratory |
| Mass Range | 2–290 u |
| Resolution (Unit Mass Resolution) | User-Configurable |
| Detection Limits (ng·L⁻¹) | ⁹Be < 0.3, ¹¹⁵In < 0.1, ²⁰⁹Bi < 0.1 |
| Sensitivity (Mcps / mg·L⁻¹) | Standard Mode — ⁷Li: 80, ⁵⁹Co: 290, ¹¹⁵In: 600, ²⁰⁹Bi: 500, ²³⁸U: 850 |
| He KED Mode — ⁵⁹Co | 70 |
| Short-Term Stability (RSD, 10 min) | < 2% |
| Long-Term Stability (RSD, 2 h) | < 3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | iCAP MTX ICP-MS |
| Application | Laboratory-based elemental and isotopic analysis |
| Mass Range (amu) | 2–290 u (m/z >225 available only with intelligent Mass Resolution [iMR] enabled) |
| Resolution (Unit Mass Resolution, amu) | User-configurable |
| Detection Limits (ng·L⁻¹) | ⁹Be <0.3, ¹¹⁵In <0.1, ²⁰⁹Bi <0.1 |
| TQ-O₂ mode | ³²S (as SO⁺) <50, ³¹P (as PO⁺) <15, ⁷⁸Se (as SeO⁺) <1, ²⁸Si (as SiO⁺) <50 |
| Sensitivity (Mcps/mg·L⁻¹) | Standard Mode: ⁷Li 65, ⁵⁹Co 180, ¹¹⁵In 400, ²⁰⁹Bi 340, ²³⁸U 550 |
| KED Mode | ⁵⁹Co 60 |
| Short-term Stability (RSD, 10 min) | <2% |
| Long-term Stability (RSD, 2 h) | <3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | iCAP RQ |
| Instrument Type | Quadrupole ICP-MS |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Instrument Type | Quadrupole ICP-MS |
| Model | iCAP RQ |
| Vacuum System | High-vacuum dual-stage turbomolecular pumping |
| RF Generator | Solid-state, 27.12 MHz, auto-tuning |
| Collision/Reaction Cell | Quadrupole-based with KED (Kinetic Energy Discrimination) mode |
| Detection Range | Li (m/z 6) to U (m/z 238) |
| Detection Limit | Sub-pg/L (ppt) for low-mass elements in He KED mode |
| Sample Introduction | Compatible with standard nebulizers, microflow systems, and laser ablation interfaces |
| Regulatory Compliance | Designed for EPA Method 6020B, ISO/IEC 17025, USP <232>/<233>, FDA 21 CFR Part 11 support via Qtegra ISDS software |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iCAP RQplus ICP-MS |
| Price | Upon Request |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–290 |
| Unit Mass Resolution (amu) | 2–290 |
| Instrument Detection Limits (ng·L⁻¹) | Be < 0.5, In < 0.1, Bi < 0.1 |
| Sensitivity (Mcps / mg·L⁻¹) | Li > 65, Co > 110, In > 270, U > 400 |
| Short-Term Stability (RSD, 10 min) | < 2% |
| Long-Term Stability (RSD, 2 h) | < 3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific™ iCAP™ TQ ICP-MS |
| Instrument Type | Triple Quadrupole ICP-MS |
| Price Range | USD 420,000 – 700,000 (approx. based on exchange rate and configuration) |
| Software Platform | Thermo Scientific Qtegra ISDS v3.x or later |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | ISQ 7000 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Coupling |
| Scan Speed | ≤ 20,000 u/s |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ISQ LT |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography-Mass Spectrometry System |
| Mass Range | 1.2–1100 u |
| Ion Source | ExtractaBrite™ |
| Detection Mode | Full Scan and SIM Simultaneously |
| Data Acquisition Rate | Up to 10,000 Da/sec |
| Vacuum System | Extended Turbo Molecular Pump |
| Optional Ionization Modes | Electron Ionization (EI), Chemical Ionization (CI) |
| Compatible Inlets | Split/Splitless, PTV, Large Volume Injection (LVI), Backflush, Thermal Desorption, Purge & Trap, SPME |
| Software Platforms | Xcalibur™, TraceFinder™, Chromeleon™ Simply Intelligent™ |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ISQ QD |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | LCQ Fleet Ion Trap LC-MS |
| Instrument Type | Ion Trap |
| Price Range | USD 650,000 – 980,000 (converted at ~1:7.7 exchange rate, FOB US port) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LTQ Orbitrap Discovery |
| Instrument Type | Orbitrap Hybrid Mass Spectrometer |
| Resolution | 30,000 (at m/z 400) |
| Mass Accuracy | < 5 ppm (internal calibration), < 3 ppm (external calibration) |
| Scan Speed | Up to 10 MS/MS spectra per second |
| MSⁿ Capability | Up to MS⁵ |
| Ionization Options | ESI, APCI (standard) |
| LC Compatibility | Fully compatible with all major UHPLC and HPLC systems |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LTQ Orbitrap |
| Price Range | USD 135,000 – 270,000 (FOB) |
| Instrument Type | Quadrupole-Orbitrap Hybrid |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Orbitrap Hybrid Mass Spectrometer |
| Model | LTQ Orbitrap XL ETD |
| Mass Range | 50–4000 m/z |
| Sensitivity | S/N ≥ 100:1 for 2 pg reserpine (full-scan, MS mode) |
| Resolution | 60,000 at m/z 400 (FWHM) |
| Mass Accuracy | ≤ 2 ppm (internal calibration), ≤ 5 ppm (external calibration) |
| Activation Methods | CID, HCD, ETD |
| Software Platforms | Proteome Discoverer, ProSightPC, Xcalibur |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | LTQ Orbitrap XL |
| Instrument Type | Orbitrap Hybrid Mass Spectrometer |
| Resolution (at m/z 400) | 30,000 (FWHM) |
| Scan Speed | Up to 10 MS/MS spectra per second |
| Mass Accuracy | < 5 ppm (internal calibration), < 3 ppm (external calibration) |
| MSⁿ Capability | Up to MS⁵ |
| Fragmentation Methods | CID, HCD, ETD |
| Optional Ion Source | MALDI Source (compatible) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | LTQ XL |
| Instrument Type | Linear Ion Trap |
| Ionization Sources | ESI, APCI, APPI, NSI |
| Key Dissociation Techniques | CID, PQD, ETD |
| Software | Xcalibur, Mass Frontier, MetWorks |
| Regulatory Compliance | FDA 21 CFR Part 11 ready, GLP/GMP-supportive data acquisition and audit trail |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LTQ-FT Ultra |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Hybrid Tandem Mass Spectrometer (LTQ + FTICR) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LXQ Linear Ion Trap Mass Spectrometer |
| Price Range | USD 140,000 – 280,000 (FOB) |
| Instrument Type | Linear Ion Trap |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MAT 253 |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Mass Range | m/z 1–150 |
| Magnet Radius | 460 mm |
| Ion Source & Analyzer | All-Metal Vacuum-Sealed Construction |
| Supported Isotopic Ratios | δ²H, δ¹³C, δ¹⁵N, δ¹⁸O, δ³⁴S (in SO₂ and SF₆), δ²⁹Si, plus noble gases (Ar, Kr, Xe) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | NEPTUNE Plus |
| Price Range | USD 680,000 – 950,000 (FOB Hamburg) |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Orbitrap Ascend Editions Tribrid Series |
| Instrument Type | Orbitrap-Based Hybrid Mass Spectrometer |
| Application Domain | Universal |
| Mass Range | Standard mode 40–2000 m/z |
| Sensitivity | 100 fg reserpine, full-scan MS/MS at unit mass resolution, S/N ≥ 200:1 |
| Resolution | 7,500–480,000 FWHM (at m/z 200) |
| Mass Accuracy | <3 ppm RMS over 24 h using FlexMix calibration solution with external calibration |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific™ Orbitrap Ascend Tribrid Mass Spectrometer |
| Instrument Type | Orbitrap-based Tribrid MS |
| Application Scope | Universal |
| Mass Range | m/z 40–6000 (extendable to m/z 16,000 with optional high-mass configuration) |
| Resolution | 7,500–480,000 FWHM at m/z 200 |
| Mass Accuracy | <3 ppm RMS with external calibration |
| Optional Features | Dual IRM (Ion Routing Multipole), Auto-Ready Ion Source, Real-Time Library Search, AcquireX Data Acquisition Workflow, UVPD (Ultraviolet Photodissociation), PTCR (Protein Topography and Migration Analysis), Easy-ETD, EASY-IC (Internal Calibration), Preconfigured Application-Specific Method Templates |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Orbitrap Elite™ |
| Instrument Type | Hybrid Orbitrap Mass Spectrometer |
| Mass Analyzer | High-Field Orbitrap + Dual-Pressure Linear Ion Trap (Velos Pro™) |
| Key Capabilities | High-Resolution Accurate-Mass (HRAM) Detection, MS/MS and MSⁿ with CID/ETD/HCD, Top-Down & Bottom-Up Proteomics, Untargeted Metabolomics, Lipidomics |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China-manufactured) |
| Model | Thermo Scientific Orbitrap Exploris 120 |
| Pricing | Available Upon Request |
| Mass Resolution | 120,000 (FWHM at m/z 200) |
| Mass Range | 40–3000 m/z |
| Mass Accuracy | <1 ppm RMS (with internal lock mass calibration, 24 h) |
| Dynamic Range | >5000:1 (within single Orbitrap scan) |
| Scan Rate | Up to 22 Hz (at R=15,000, m/z 200) |
| Polarity Switching Cycle | <700 ms (full-scan positive + negative, R=60,000) |
| Weight | 120 kg (excl. PC, roughing pump, options) |
| Environmental Compliance | Energy-efficient design, reduced solvent waste footprint |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Orbitrap Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Interface |
| Mass Range | m/z 30–3000 |
| Resolution | Up to 240,000 at m/z 200 |
| Scan Speed | Up to 40 Hz at resolution setting 7,500 (m/z 200) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Orbitrap Mass Spectrometer |
| GC-MS Configuration | Conventional Gas Chromatography–Mass Spectrometry System |
| Mass Range | m/z 30–3000 |
| Resolution | Up to 30,000 FWHM at m/z 200 |
| Scan Speed | Up to 40 Hz at Resolution Setting of 7,500 (FWHM) at m/z 200 |