Mass Spectrometry Instruments
Filter
Showing 301–330 of 762 results
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOFMS) |
| GC Configuration | Comprehensive 2D Gas Chromatography (GC×GC) |
| Mass Range | m/z 1–1500 |
| Sensitivity | 1 fg octafluoronaphthalene (OFN) in full-scan mode |
| Acquisition Rate | 35,000 spectra per second |
| Cooling System | Cryogen-free electrically cooled modulator |
| Modulation Technology | Dual-stage, quad-jet thermal modulator |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Model | Pegasus GC-HRT 4D+ |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Chromatography Type | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) |
| Mass Range | 15–1500 Da |
| Resolution | 25,000 / 50,000 (FWHM at m/z 200) |
| Sensitivity | 0.1 pg OFN (octafluoronaphthalene), S/N > 150 (UR model) |
| Acquisition Rate | 200 spectra/s |
| Ionization Modes | Electron Impact (EI) and Chemical Ionization (CI) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Pegasus |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOFMS) |
| Autosampler | CTC LEAP CombiPAL (Auto Headspace / Liquid / SPME) |
| Oven Temperature Control | LTM A68 with Range 0–400 °C and Ramp Rate ±1800 °C/min |
| Data Acquisition Speed | Up to 500 full-spectrum scans per second |
| Software | ChromaTOF v5.x or later |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Pegasus HRT |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Data Acquisition Rate | 200 full-spectrum scans/sec |
| Mass Resolution (Full Width at Half Maximum, FWHM) | 50,000 across full mass range |
| Mass Accuracy | <100 ppb (external calibration, 3-day interval) |
| Dynamic Linear Range | 10⁵–10⁶ |
| Ion Transmission Efficiency (Multi-Reflection Path) | >80% |
| Effective Flight Path Length | 64 m |
| Calibration Options | External standard, Continuous internal standard, Pseudo-external standard |
| Software | ChromaTOF v5.2+ with TrueSignal™ Deconvolution, PeakFind™, Library Search (NIST, Wiley, LECO Custom) |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | GC-TOFMS |
| Model | Pegasus HT |
| Mass Range | 5–1000 m/z |
| Sensitivity | 1 pg octafluoronaphthalene (OFN) |
| Acquisition Speed | 500 full spectra per second |
| Detector | Microchannel Plate (MCP) Detector |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TruTOF HT |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Acquisition Rate | 80 full-scan spectra/sec |
| Data Transfer Rate | 20,000 spectra/sec |
| Mass Range | m/z 5–1000 |
| Resolution (FWHM) | 2000 |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with rapid switching |
| Ion Source | Field-serviceable design |
| Dynamic Signal Tracking | Yes |
| Quantitation Limit | Sub-pg level for target analytes |
| Regulatory Compliance | EPA-certified for environmental and food safety applications |
| Form Factor | Benchtop |
| Brand | Advion |
|---|---|
| Origin | USA |
| Model | TriVersa NanoMate® |
| Instrument Type | Chip-Based Nanoelectrospray Ion Source |
| Mass Range | 100 Da – 100 kDa |
| Sensitivity | Dependent on Coupled Mass Spectrometer |
| Resolution | Dependent on Coupled Mass Spectrometer |
| Accurate Mass Capability | Dependent on Coupled Mass Spectrometer |
| Compliance | ASTM E2915, ISO/IEC 17025 (when operated in GLP/GMP environments), FDA 21 CFR Part 11–ready software architecture |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Architecture | Low Thermal Mass (LTM) Gas Chromatograph |
| Ion Source | High-Temperature Inert Ceramic Electron Ionization (EI) Source |
| Mass Analyzer | Precision All-Metal Quadrupole |
| Mass Range | 10–500 amu (standard configuration) |
| Detector | Electron Multiplier with High-Energy Conversion Dynode |
| Injection | Split/Splitless Injector |
| Column Interface | On-Column Heated Capillary Column |
| Carrier Gas Flow | Direct-to-Source Pneumatic Control |
| Preconcentration | Integrated Quantitative Loop and Sorbent-Based Trap (software-selectable) |
| Compliance | Designed to support EPA Method 8260D, ASTM D7622, and ISO 16000-6 workflows |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | PHOENIX Quadro |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5 × 10⁻¹² mbar·L/s |
| Startup Time | ≤ 2 min |
| Response Time | < 1 s |
| Maximum Inlet Pressure | 1500 Pa |
| Helium Purge Speed | 3.1 L/s |
| Leak Rate Display Range | 1 × 10⁻³ to 1 × 10⁻¹³ Pa·m³/s |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 912-0021 |
| Price | Upon Request |
| Brand | LGR |
|---|---|
| Origin | USA |
| Model | CCIA/WVIA |
| Measurement Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Isotopic Ratios | δ¹³C/δ¹⁸O (CO₂), δ²H/δ¹⁷O/δ¹⁸O (H₂O) |
| Precision (1σ) | δ¹³C ≤ 0.1‰ (5 min), δ¹⁸O ≤ 1‰ (5 min), δ²H ≤ 0.2‰ (100 s), δ¹⁷O ≤ 0.05‰ (100 s) |
| Measurement Frequency | Up to 2 Hz (WVIA), 1 Hz (CCIA) |
| Effective Optical Path | >2 km |
| Operating Temperature | 0–45 °C |
| Sample Temp Range | −20 to +50 °C |
| Pressure Control Accuracy | ±0.001 torr |
| Temperature Control Accuracy | ±0.003 °C |
| Data Interfaces | RS-232, Ethernet, USB |
| Power | 115/230 VAC, 50/60 Hz, 550 W max |
| Brand | LGR |
|---|---|
| Origin | USA |
| Model | 908-0008, 912-0008 |
| Measurement Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Isotopes Measured | δ²H and δ¹⁸O in liquid water |
| Precision (High-Accuracy Mode, 1σ) | δ²H < 0.3‰, δ¹⁸O < 0.1‰ |
| Precision (High-Throughput Mode, 1σ) | δ²H < 0.6‰, δ¹⁸O < 0.2‰ |
| Sample Volume per Injection | < 1 µL (adjustable) |
| Max. Daily Injections | 1080 |
| Unknown Samples per Day | 150 (high-throughput), 30 (high-accuracy) |
| Salinity Tolerance | < 4% w/w |
| Operating Temperature | 5–45 °C |
| Sample Temperature Range | 0–50 °C |
| Output Interfaces | RS-232, Ethernet, USB |
| Power | 115/230 VAC, 50/60 Hz, 150 W |
| Dimensions | 25.4 cm (H) × 96.5 cm (W) × 35.6 cm (D) |
| Weight | 27 kg |
| Brand | LGR |
|---|---|
| Origin | USA |
| Model | 914-0060 |
| N₂O Concentration Detection Limit | 0.2 ppb (1σ, >300 ppb N₂O) |
| δ¹⁵N, δ¹⁵Nα, δ¹⁵Nβ Precision | <1‰ (300 s integration) |
| δ¹⁷O Precision | <1‰ (300 s, N₂O >10 ppm) |
| δ¹⁸O Precision | <1‰ (1000 s) |
| N₂O Measurement Range | 0.3–100 ppm (full-spec) |
| Spectral Resolution | <1‰ for all isotopic ratios |
| N₂O Mass Range Coverage | 0–1000 ppm |
| Operating Temperature | 0–45 °C |
| Relative Humidity | 0–100% RH (non-condensing) |
| Temperature Stability | ±0.003 °C |
| Pressure Control Accuracy | ±0.001 torr |
| Power | 115/230 VAC, 50/60 Hz, 400 W |
| Dimensions | 35.6 cm (H) × 48.3 cm (W) × 114.3 cm (D) |
| Weight | 68 kg |
| Origin | USA |
|---|---|
| Manufacturer | Los Gatos Research |
| Type | Imported |
| Model | 908-0004-9002 (Standard Range), 908-0004-9003 (Extended Range) |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Average Power Consumption | 30 W |
| Standby Power | 10 W |
| Max Power | 300 W |
| Dimensions (Std) | 26.7 cm H × 48.3 cm W × 43.2 cm D |
| Weight (Std) | 27 kg |
| Dimensions (Ext) | 26.7 cm H × 48.3 cm W × 58.4 cm D |
| Weight (Ext) | 29 kg |
| H₂O Vapor Range (Std) | 3000–30,000 ppm |
| H₂O Vapor Range (Ext) | 500–30,000 ppm |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-7825 |
| Instrument Type | Stable Gas Isotope Ratio Analyzer |
| CO₂ Measurement Range | 50–2000 ppm |
| CO₂ δ¹³C Precision | <0.5 ‰ (1-s avg), <0.04 ‰ (5-min avg) @ 400 ppm |
| CO₂ δ¹⁸O Precision | <0.1 ‰ (5-min avg) @ 400 ppm |
| CO₂ δ¹⁷O Precision | <0.4 ‰ (5-min avg) @ 400 ppm |
| NH₃ Measurement Range | 0–30,000 ppm |
| NH₃ Precision | 2 ppb (1-s avg) @ 300 ppb |
| H₂O Range | 0–60,000 ppm |
| Measurement Technique | Optical Feedback–Cavity Enhanced Absorption Spectroscopy (OF-CEAS) |
| Measurement Frequency | 1 Hz |
| Cavity Volume | 6.41 cm³ |
| Sample Flow Rate | 250 sccm (70 sccm with low-flow accessory) |
| Operating Temperature | −25 °C to +45 °C |
| Operating Humidity | 0–85 % RH (non-condensing, no direct sunlight) |
| Power Consumption | 22 W @ 25 °C |
| Weight | 10.5 kg (with battery) |
| Dimensions (L×H×W) | 51 × 33 × 18 cm |
| Connectivity | Ethernet & Wi-Fi (2.4 GHz, 802.11 a/b/g/n/ac) |
| Brand | Phytronix |
|---|---|
| Origin | Canada |
| Model | Luxon |
| Instrument Type | Atmospheric Pressure Ion Source |
| Technology | Second-Generation Laser Diode Array Thermal Desorption (LDTD²) |
| Sample Throughput | Up to 30,000+ samples/24h |
| Analysis Time per Sample | ≤ 0.6 s |
| Compatible Plate Formats | 96-well, 384-well, 1536-well LazWell™ microplates |
| Automation Level | Fully Robotic, Unattended Operation |
| MS Compatibility | SCIEX, Thermo Fisher, Waters, Shimadzu triple quadrupole and Q-TOF mass spectrometers |
| Regulatory Alignment | Designed for GLP/GMP-compliant workflows with audit-trail-ready software architecture |
| Ionization Mechanism | Solvent-free, atmospheric-pressure chemical ionization (APCI) via laser-induced rapid thermal desorption |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | M7 |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Standalone GC-MS Platform |
| Mass Range | 1.5–1050 Da |
| Resolution | Unit Mass Resolution (UMR) |
| Mass Stability | ±0.1 Da over 48 h |
| Repeatability | RSD ≤9% for 10 ng Hexachlorobenzene (m/z 284) |
| Ion Source | Dual-Filament Electron Impact (EI) Source |
| Vacuum System | Pfeiffer Turbo Molecular Pump (60 L/s) |
| Interface | LAN-enabled Remote Operation |
| Software | Graphical User Interface (GUI) with Embedded Method Library |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Mars-400 Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | 15–550 amu |
| Mass Resolution | Unit mass resolution |
| Detection Limit | < ppb (for selected VOCs/SVOCs) |
| Maximum Scan Rate | 10,000 amu/s |
| Sensitivity | Optimized for trace-level detection in field conditions |
| Weight | 17 kg |
| Power Supply | Integrated rechargeable battery pack |
| Carrier Gas | Built-in helium or hydrogen micro-gas cylinder (optional) |
| Brand | MassTech |
|---|---|
| Origin | USA |
| Model | UHR, HR |
| Instrument Type | Atmospheric Pressure Ion Source |
| Sensitivity | Attomole-level (sub-fmol/µL) |
| Spatial Resolution | <5 µm |
| Mass Range | Determined by Coupled Mass Analyzer |
| Accurate Mass Capability | Dependent on Host Mass Spectrometer |
| Brand | MassTech (ASPEC as authorized distributor) |
|---|---|
| Origin | USA |
| Instrument Type | 3D Ion Trap Mass Spectrometer |
| Model | MT50 |
| Mass Range | 30–2500 amu |
| Sensitivity | 50 pg/µL reserpine, S/N ≥ 10:1 |
| Resolution | 6000 (FWHM at m/z 400) |
| Mass Accuracy | ±0.3 amu |
| Scan Speed | 1000–8000 amu/s or up to 5 spectra/sec |
| Ionization Compatibility | ESI, oESI, 2ndESI, APCI, DART, AP/MALDI |
| Power Input | 90–240 VAC, 50/60 Hz |
| Power Consumption | 250–300 W |
| Dimensions (L×W×H) | 51 × 43 × 30 cm |
| Weight | <35 kg |
| Operating Mode | MS¹ and MSⁿ (up to MS⁵) |
| Polarity | Positive/Negative Switchable |
| Gas Requirement | None (gas-free operation) |
| Transport | Shock-damped wheeled case |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MIBIscope |
| Price Range | USD 1.4M – 2.8M |
| Instrument Type | Time-of-Flight (TOF) |
| Primary Ion Beam Energy | 30 kV |
| Mass Range | >12,000 u |
| Mass Resolution | 11,000–16,000 (at m/z 150–200) |
| Brand | MINSPEC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MP-5600 |
| Instrument Type | Linear Ion Trap Mass Spectrometer |
| Chromatography Configuration | Low Thermal Mass (LTM) Gas Chromatograph |
| Mass Range | 15–550 m/z |
| Scan Speed | 10,000 Da/s |
| Mass Accuracy | High (typical ≤ 0.2 Da RMS error under calibration) |
| Oven Ramp Rate | Up to 30 °C/s |
| Detection Limit | Sub-ppt (v/v) for target VOCs in air matrix |
| Dimensions | 420 × 320 × 210 mm |
| Weight | <12.5 kg |
| Sample Introduction | Direct gas, headspace, liquid injection, and thermal desorption (solid-phase microextraction compatible) |
| Brand | MINSPEC |
|---|---|
| Model | MP-5600 |
| Origin | Shandong, China |
| Instrument Type | Portable GC-MS |
| Mass Range | AMU (atomic mass units) |
| Dynamic Range | 7 decades |
| Mass Resolution | <1.0 amu at FWHM |
| Scan Modes | Full Scan, Selected Ion Monitoring (SIM), Tandem MS (MS/MS) |
| Sensitivity | 10× higher than conventional portable GC-MS systems |
| Weight | Not specified |
| Brand | MINSPEC |
|---|---|
| Model | MP-5600Plus |
| Mass Range | 15–550 Da |
| Scan Speed | 10,000 Da/s |
| Mass Analyzer Type | Linear Ion Trap |
| Detection Principle | Electron Ionization (EI) with Inert High-Temperature Ion Source |
| Sample Introduction | Triple-mode (Gas, Liquid, Solid) |
| Compliance | GB/T 11606–2007, GB/T 32210–2015, GJB 150.16A–2009, HJ 1223–2021, HJ 1227–2021 |
| Brand | MINSPEC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MP-5600Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | 15–550 Da |
| Dynamic Range | 7 decades |
| Mass Resolution | Unit Mass Resolution |
| Maximum Scan Rate | 10,000 scans/s |
| Sensitivity | sub-ppt (gas-phase VOCs) |
| Weight | <18 kg |
| Brand | MINSPEC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MP-5600Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | Not Specified (AMU) |
| Dynamic Range | 7 decades |
| Mass Resolution | <1.0 amu at FWHM |
| Scan Modes | Full Scan, Selected Ion Monitoring (SIM), Tandem MS (MS/MS) |
| Sensitivity | ~10× higher than conventional portable GC-MS for ODS compounds |
| Weight | Not Specified (kg) |
| Origin | Europe |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MS GAS-100 |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Resolution (Full Width at Half Maximum, FWHM) | ≤0.8 amu |
| Detection Limits (ng·L⁻¹) | Be ≤ 2 |
| Sensitivity (Mcps / mg·L⁻¹) | Be ≥ 6 |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PlasmaMS 400 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–260 |
| Resolution (Unit Mass Resolution, amu) | 0.3–1.0 (Continuously Adjustable) |
| Detection Limits (ng·L⁻¹) | Be ≤ 0.5 |
| Sensitivity (Mcps/mg·L⁻¹) | Li > 80 |
| Short-Term Stability (RSD) | ≤ 2% |
| Long-Term Stability (RSD) | ≤ 3% |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |