Mass Spectrometry Instruments
Filter
Showing 331–360 of 759 results
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Warm-up Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻⁹ Pa·m³/s (zero-referenced) |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NHJ600 |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NHJ800D |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻⁹ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Warm-up Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Ion Source | Dual Iridium Filament |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Astrum ES |
| Pricing | Available Upon Request |
| Brand | Nu Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Nu AttoM ES |
| Type | Double-Focusing Magnetic Sector ICP-MS |
| Detector System | Wide Dynamic Range Faraday + Secondary Electron Multiplier (SEM) |
| Resolution Mode | Adjustable High-Resolution Slit (Fixed Width, Vertically Movable) |
| Primary Application | Isotope Ratio Analysis & Ultra-Trace Elemental Quantification in Geochemical and Environmental Matrices |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Model | Perspective |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Mass Dispersion | Up to 600 mm |
| Mass Resolution (m/Δm) | >200 for CNOS and H |
| Collector Configuration | Up to 12 fixed, high-precision Faraday and/or multi-collector arrays |
| Ion Source | High-efficiency electron impact ion source |
| Optics | Patented zoom optics system |
| Compatible Interfaces | NU Dual Inlet, NU GasBench, NU Carbonate Device |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Vitesse |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GPC-GCMS |
| Pricing | Upon Request |
| Mass Analyzer Type | Single Quadrupole |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RGA100 / RGA200 |
| Principle | Electron Ionization (EI) Quadrupole Mass Spectrometry |
| Mass Range | 0–200 amu |
| Minimum Sampling Interval | 0.05 amu |
| Mass Resolution (FWHM) | < 0.5 amu |
| Ion Source | EI Source with Yttria-Coated Iridium Filament (Filament Current: 0–4 A) |
| Detector | Electron Multiplier (Gain > 10³) |
| Scan Speed | 5–1000 ms per data point |
| Compliance | Designed for UHV and HV vacuum environments |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Clarus SQ 8 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC/MS Configuration | Conventional Gas Chromatography–Mass Spectrometry System |
| Mass Range | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Scan Speed | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | DRC-e |
| Mass Analyzer Type | Quadrupole |
| Resolution (FWHM at m/z 202) | ≤ 0.8 amu |
| Detection Limit | sub-ppq ng·L⁻¹ |
| Sensitivity | Be ≥ 5 Mcps/(mg·L⁻¹), In ≥ 30 Mcps/(mg·L⁻¹), Bi ≥ 20 Mcps/(mg·L⁻¹) |
| Vacuum System | Dual mechanical pumps + dual turbo-molecular pumps (total pumping speed > 380 L/min) |
| Linear Dynamic Range | 9 orders of magnitude |
| DRC Gas Options | H₂, He, CH₄, NH₃, O₂, N₂O, CO₂ |
| Interference Reduction Efficiency | > 10⁷-fold |
| Chemical Resolution | > 150,000 |
| Isotopic Ratio Precision (¹⁰⁷Ag/¹⁰⁹Ag) | < 0.08% RSD |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin Category | Imported |
| Model | GCMS 2400 System |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Gas Chromatography Configuration | Conventional GC-MS Platform |
| Software | SimplicityChrom™ Chromatography Data System (CDS) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer | PerkinElmer |
| Import Status | Imported |
| Model | NexION 1000G |
| Instrument Type | Quadrupole ICP-MS |
| Interface Configuration | Triple-cone interface with UltraConic™ design |
| RF Generator | Self-excited solid-state generator with LumiCoil™ technology |
| Ion Optics Architecture | Three-quadrupole tandem mass spectrometry platform (quadrupole ion deflector, quadrupole universal cell, quadrupole mass analyzer) |
| Application Scope | Environmental, geological, food & pharmaceutical, industrial QA/QC, speciation analysis |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | NexION 100G |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | NexION 1100/1000G ICP-MS |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NexION 2200 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Mass Spectrometry |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NexION 300 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Resolution (FWHM at 202Hg) | ≤ 0.8 amu |
| Detection Limit | sub-ppq ng·L⁻¹ |
| Sensitivity (Mcps / mg·L⁻¹) | Be ≥ 5, In ≥ 30, Bi ≥ 20 |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NexION 5000 |
| Instrument Type | Quadrupole-based ICP-MS |
| Application Environment | Laboratory |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QSight 400 |
| Instrument Type | Triple Quadrupole (TQ) LC-MS/MS |
| Application Scope | General-Purpose |
| Mass Range | Available upon consultation |
| Sensitivity | Available upon consultation |
| Resolution | Available upon consultation |
| Accurate Mass Capability | Not applicable (unit-mass resolution TQ system) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QSight 500 |
| Instrument Type | Triple Quadrupole (TQ) LC/MS/MS |
| Application Scope | General-purpose quantitative and confirmatory analysis in regulated and research laboratories |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | QSight |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Application Domain | General-Purpose Quantitative Analysis |
| Ionization Sources | Dual ESI/APCI Configurable |
| Polarity Switching Speed | Microsecond-Level |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) Coupled with Triple Quadrupole Mass Filtering and Collision-Induced Dissociation (CID) |
| [Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Single Quadrupole GC-MS |
| GC Platform | Agilent 7890A |
| Mass Range | 1.5–1050 amu |
| Mass Accuracy | ±0.1 amu |
| Resolution | Unit Mass Resolution (R = 1000, W₁/₂ < 1 amu) |
| S/N (EI) | ≥150:1 RMS (5 pg OFN full scan, m/z 272 |
| Mass Stability | ±0.1 amu over 48 h |
| Max Scan Speed | 10,000 amu/s |
| Vacuum System | Dual-stage — GLD-N201 forepump (4 L/s) + Pfeiffer TMH071P (60 L/s) or TMH262P (210 L/s) turbomolecular pump |
| Ion Source | Heated EI source, 350 °C max, 10–100 eV electron energy, 200 µA emission current |
| Detector | High-voltage conversion dynode electron multiplier with composite I/V amplifier |
| Control Interface | 100 Mbps Ethernet, 32-bit embedded real-time OS |
| Software | Persee ChemStation v3.x (NIST08 library integrated)] |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 102 S |
| Minimum Detectable Leak Rate (He) | 1×10⁻⁸ Pa·m³/s (7.5×10⁻⁸ Torr·L/s, 1×10⁻⁷ mbar·L/s) |
| Measurement Range (He) | 1×10⁻⁷ to 1 mbar·L/s |
| Detection Gas | ⁴He |
| Forevacuum Pump | Oil-free dry scroll pump |
| Operating Temperature | 0–45 °C |
| Warm-up Time | 1.5 min |
| Detection Mode | Sniffer Probe (Handheld) |
| Weight | 18 kg |
| Probe Cable Length | 5 m |
| Nozzle Diameter | 9 mm |
| Power Supply Options | 110/130 V AC or 200/240 V AC |
| Display Language Options | English, French, German |
| Remote Control | Integrated handheld controller |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM 142 S |
| Detection Limit (He) | 1 × 10⁻⁸ Pa·m³/s |
| Measurement Range (He) | 1 × 10⁻⁷ to 1 mbar·L/s |
| Forepump | Oil-Sealed Rotary Vane Pump |
| Detectable Gas | ⁴He |
| Operating Temperature | 0–45 °C |
| Acoustic Noise Level | < 57 dB(A) |
| Dimensions (W × D × H) | 517 × 357 × 420 mm |
| Warm-up Time | 2 min |
| Detection Mode | Sniffer (Probe-Based) |
| Weight | 55 kg |
| Standard Probe | 5 m Flexible Hose with 9 cm Rigid Nozzle |
| Power Supply Options | 110–130 V AC (North America) or 200–240 V AC (Europe) |
| Interface | RS-232 / USB / Optional PLC Integration |
| Display Language Options | English, French, German, Chinese |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 192T |
| Forepump Speed | 20 or 40 m³/h |
| Helium Pumping Speed | 4.4 L/s |
| Minimum Detectable Leak Rate (He) | 5 × 10⁻¹² hPa·L/s |
| Inlet Flange | DN 40 ISO-KF |
| Maximum Inlet Pressure | 6 hPa |
| Detection Modes | Vacuum Mode & Sniffer Mode |
| Warm-up Time | 3 min |
| Power Supply | 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 594 × 692 × 933 mm |
| Weight | 125 kg |
| Display | Color Graphical Touchscreen |
| Language Options | Multi-language UI |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 306S |
| Minimum Detectable Leak Rate (He) | 1×10⁻⁷ mbar·L/s |
| Minimum Detectable Leak Rate (H₂) | 5×10⁻⁷ mbar·L/s |
| Sensitivity | 0.2 g/y (refrigerant loss equivalent) |
| Startup Time | 2 min |
| Response Time | < 1 s |
| Sniffer Probe Flow Rate | 300 sccm ±10% |
| Noise Level | 55 dB(A) |
| Interfaces | RS-232, Digital I/O, Fieldbus Options |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 V, 50/60 Hz |
| Max. Power Consumption | 300 VA |
| Weight | 22 kg |
| Dimensions (L×W×H) | 350 × 305 × 421 mm |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 310 |
| Application | In-service turbine vacuum system leak detection |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 310 |
| Helium Minimum Detectable Leak Rate (Vacuum Mode) | 5×10⁻¹³ Pa·m³/s |
| Helium Minimum Detectable Leak Rate (Sniffer Mode) | 1×10⁻⁸ Pa·m³/s |
| Helium Pumping Speed | 1.1 L/s |
| Inlet Pressure Limit | 15 hPa |
| Roughing Pump | MVP 020 Diaphragm Pump (1.7 m³/h) |
| Inlet Flange | DN 25 ISO-KF |
| Operating Temperature | 10–40 °C |
| Noise Level | < 45 dB(A) |
| Power Supply | 90–240 V AC, 50/60 Hz |
| Max. Power Consumption | 300 VA |
| Warm-up Time | < 2 min |
| Dimensions (W×H×D) | 350 × 254 × 415 mm |
| Weight | 21 kg |
| Interfaces | RS-232, USB, Digital I/O |
| Display | High-brightness color touchscreen with image function, 10 language options |
| Detection Gases | ⁴He, ³He, H₂ |
| Response Time | < 1 s |