Mass Spectrometry Instruments
Filter
Showing 241–270 of 759 results
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HAL/3F |
| Mass Range | 1–50 amu (high-resolution quadrupole) |
| Detection Sensitivity | ppm-level |
| Long-term Stability | < ±0.5% peak height drift over 24 h |
| Ionization Modes | Electron Impact (EI), Threshold Ionization (e.g., D₂/He selective detection) |
| Software Control | MASsoft v6.x |
| Data Output | ASCII, DDE-compatible (Excel, SPC-IV, custom SCADA/HMI systems) |
| Compliance | CE-marked, RoHS-compliant, designed for vacuum system integration per ISO 27893 and ASTM E1940-20 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HALO 201 MBE |
| Mass Range | 1–300 amu |
| Scan Speed | 100 amu/s |
| Minimum Scan Step | 0.01 amu |
| Sensitivity | 0.1–1 ppm |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Minimum Detectable Partial Pressure | 2 × 10⁻¹³ mbar |
| Maximum Operating Pressure | 1 × 10⁻⁴ mbar |
| Detector | Dual Faraday/Channelplate Electron Multiplier |
| Ion Source Shield | Contamination-Resistant |
| Filament Wiring | Molybdenum-Copper Alloy |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR-40 DEMS |
| Mass Range | 50–300 amu |
| Resolution | < 1 amu |
| Sensitivity | 0.1 ppm (standard quadrupole) or 5 ppb (triple-filtered quadrupole option) |
| Electrode Interface | User-coatable Pt/C working electrode + 4 additional electrode ports |
| Membrane | Replaceable nanoscale hydrophobic membrane |
| Ionization | Soft ionization capability |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR-40 |
| Mass Range | 200 / 300 / 510 amu (selectable) |
| Detection Limit | 5 ppb |
| Stability | < ±0.5% peak height over 24 h |
| Ion Source | Liquid Nitrogen-cooled cold trap |
| Inlet Options | 4-channel or 8-channel multiplexed membrane probes |
| Vacuum Protection | Penning gauge + interlock system |
| Control Interface | RS232, RS485, Ethernet LAN |
| Software | MASsoft v6.x |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR-80 |
| Mass Range | up to 2500 amu |
| Detection Limit | 5 ppb |
| Inlet Pressure Range | 1 mtorr to atmospheric pressure |
| Ion Source Temperature | Heated, electropolished stainless steel |
| Stability | < ±0.5% peak height over 24 h |
| Calibration | Viscous-flow QIC-corrected inlet with purge capability |
| Control Software | MASsoft |
| Compliance | Designed for UHV/HP vacuum interfaces, compatible with ASTM E1943 (standard guide for mass spectrometry in process analysis), supports GLP/GMP data integrity requirements via audit trail and user access control |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | HPR20 QIC TMS |
| Mass Range | 1–50 / 100 / 200 / 300 / 500 / 1000 amu |
| Sampling Pressure | 100 mbar–2 bar (standard) |
| Response Time | <150 ms |
| Dynamic Range | 7 decades (pulse-counting detector) |
| Detection Limit | 5 ppb |
| Quantification Range | ppm to 100% |
| Stability | ±0.5% peak height over 24 h |
| Scan Speed | 100 amu/s |
| Measurement Rate | 500 data points/sec |
| Capillary | 0.9 m heated quartz inert capillary (up to 200 °C) |
| Ionization | APSI-MS soft ionization |
| External Analog Outputs | 2 standard, up to 16 optional |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR20 |
| Mass Range | up to 510 amu |
| Detection Limit | down to 5 ppb |
| Response Time | < 500 ms |
| Sample Flow Rate | 1–20 cm³/min |
| Sampling Pressure Range | 10 mbar to 2 bar (optional high-pressure inlet up to 30 bar) |
| Capillary Temperature | up to 200 °C |
| Ion Source Pressure Control | Automatic via integrated mass flow controller |
| Cryogenic Trap | Liquid nitrogen-cooled cold finger for condensable species |
| Ionization | Soft electron ionization (EI) with adjustable electron energy |
| Long-Term Stability | ±0.5% peak height drift over 24 h |
| Communication Interfaces | RS232, RS485, Ethernet |
| Software | MASsoft Professional v6.x with GLP-compliant audit trail and calibration management |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR30 |
| Mass Range | Up to 1000 amu |
| Detection Limit | Down to 5 ppb |
| Operating Pressure Range | 1×10⁻⁴ mbar to 1 mbar |
| Ionization | Soft Electron Ionization (EI) with Tunable Energy |
| Sensitivity Optimization | Direct re-entrant sampling orifice + differential pumping stage |
| Stability | < ±0.5% peak height drift over 24 h |
| Control Software | MASsoft v6.x (Windows-based, LAN-capable) |
| Safety Interlocks | Pneumatic isolation valve with pressure- and power-failure actuation |
| Data Acquisition | Simultaneous real-time acquisition, spectral processing, and alarm triggering |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR40 |
| Mass Range | 1–200 amu (optional 300 amu) |
| Detection Limit | 0.1 ppm (or 5 ppb) |
| Minimum Scan Step | 0.01 amu |
| Detector | Faraday Cup / Electron Multiplier |
| Quantitative Output Units | ppm, ppb, % |
| Ionization Mode | Soft Ionization |
| Software | Windows-based acquisition, real-time display & spectral analysis |
| Safety Feature | Fast-acting isolation valve for membrane breach protection |
| Sample Interface | Gas-permeable membrane probe or recirculating water sampler |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HPR60 |
| Mass Range | 1–2500 amu |
| Sampling Pressure | 20 mbar to 1 bar |
| Detection Limit | 5 ppb to 100% |
| Response Time | <300 ms |
| Stability | ±0.5% peak height over 24 h |
| Data Acquisition Rate | 500 points/s |
| Electron Energy | 100–1000 eV |
| Dynamic Range | 7 decades (pulse-counting detector) |
| Interface | RS232 / RS485 / Ethernet LAN |
| Ion Source Cooling | Liquid nitrogen cryo-panel (optional water-cooled variant) |
| Vacuum Architecture | Integrated vacuum manifold with dedicated backing pump |
| Safety | Built-in Penning gauge and interlock system for overpressure protection |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | IDP |
| Mass Range (Standard) | 1–300 amu |
| Mass Range (Optional) | 500 / 1000 / 2500 amu |
| Detection Speed | 500 points/s |
| Resolution | 0.1% Valley, 1% Valley |
| Dynamic Range | 10⁷ |
| Detection Limit | 5 ppb to 100% |
| Ion Energy Range (Standard) | ±100 eV |
| Ion Energy Range (Optional) | ±1000 eV |
| Gated Signal Resolution | 0.1 µs |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Detector | Pulsed Ion Counting |
| Ion Optics | Four-stage ion lens system with integrated electron/ion source and UHV-compatible housing |
| Interface | RS232, USB, Ethernet |
| Software | MASsoft Professional Control Suite |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | IMP |
| Pump Configuration | Integrated Differential Pumping Manifold |
| Mass Range | Up to 300 amu (Triple-Filtered Quadrupole) |
| Detector | Pulsed Ion Counting System |
| Energy Analyzer | Built-in with Ion Optics |
| Pressure Protection | Penning Gauge + Interlock Circuitry |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Communication Interfaces | RS232, RS485, Ethernet |
| Control Software | MASsoft with DDE support, Parallel Digital I/O |
| Compliance | Designed for integration into ISO/IEC 17025-compliant process monitoring environments |
| Application Scope | Real-time endpoint detection, target purity verification, residual gas analysis, leak detection, SPC-driven etch process control |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | MAXIM |
| Mass Range Options | 300 amu / 500 amu / 1000 amu |
| Mass Analyzer | 3F Quadrupole (9 mm rod diameter) |
| Detector | Pulse-counting ion detector, dual-polarity (positive/negative ions), max. count rate 10⁷ cps |
| Ion Source | Electron Impact (single-filament), configurable for SNMS and Residual Gas Analysis (RGA) |
| Sample Stage Heating | Up to 250 °C |
| Optical Acceptance Angle | 30° for planar particle sampling in SIMS/SNMS geometry |
| Ion Transmission | Optimized for minimal trajectory perturbation across full energy range |
| Depth Profiling Capability | Enhanced via grating-controlled beam optics |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | PSM |
| Mass Range | 0–2500 u |
| Detection | Pulsed Ion Counting Detector (7-decade dynamic range) |
| Energy Analysis Option | Standard ±100 eV (up to ±1000 eV optional) |
| Signal Gating Resolution | 1 µs |
| Quadrupole | Triple-stage filtered, high-stability |
| Ion/Neutral Analysis | Simultaneous positive/negative ion and neutral/radical detection |
| Vacuum Interface | Differential pumping manifold with flanged process chamber coupling |
| Control Interface | RS232, RS485, or Ethernet LAN |
| Software | MASsoft Professional Suite |
| Optional Features | Electron Attachment Ion Source (tunable appearance potential MS), Penning gauge + interlock for overpressure protection, Mu-Metal/Radio-Metal magnetic shielding, High-voltage operation capability |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | QGA 2.0 |
| Detection Range | 100 ppb to 100% |
| Scan Speed | Up to 1000 spectra per second |
| Form Factor | Benchtop, Compact Design |
| Compliance | CE-marked, RoHS-compliant construction |
| Software | QGA 2.0 Quantitative Analysis Suite (Windows-based, FDA 21 CFR Part 11 ready) |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | QGA |
| Mass Range | 1–200 amu (standard) |
| Response Time | ≤300 ms |
| Sample Pressure Range | 100 mbar – 2 bar (standard) |
| Detection Range | 1 ppm – 100% |
| Software | QGA Professional Quantitative Analysis Suite |
| Multi-Channel Capability | Up to 80 gas streams (with optional multi-port sampling valve) |
| External Signal Triggering | Yes |
| Data Integration | Supports external sensor inputs (e.g., temperature, pressure, CO analyzers) |
| Spectral Processing | Automated library matching, overlap subtraction, dynamic spectral simulation |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | HAPR0128 |
| Operating Pressure Range | Near-ambient (0.1–2 mbar typical for direct inlet |
| Detection Limit | Sub-ppm for most permanent gases and volatiles |
| Mass Range | 1–100 amu (standard), upgradable to 300 amu |
| Scan Speed | Up to 100 mass units per second |
| Data Output Formats | Raw ion current, % composition, ppm/v, nmol/s |
| Multi-stream Capability | Up to 80 gas streams via optional Hiden Multiplexing Valve System (HIDEN MVS-80) |
| Software | QGA Professional Edition with real-time quantification, spectral deconvolution, and external sensor integration |
| Compliance | Designed for GLP/GMP environments |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QIC 20 |
| Pricing | Upon Request |
| Direct Inlet Response Time | <300 ms |
| Continuous Flow Range | 1–20 sccm/min |
| Sample Pressure Range | 100 mbar – 2 bar (standard) |
| Sensitivity | 0.1 ppm (standard), down to 5 ppb (optional) |
| Mass Range | 1–200 amu (standard) |
| optional configurations | 50, 100, 300, or 510 amu |
| Capillary Temperature | Up to 200 °C |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Ion Source Pressure Control | Automatic flow regulation |
| Interface Options | RS232, RS485, Ethernet |
| Software | MASsoft Professional Suite for real-time control, calibration, and quantitative analysis |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | qRGA |
| Mass Range | 1–200 amu |
| Ionization Mode | Threshold Ionization Mass Spectrometry (TIMS) |
| Electron Energy Resolution | 0.1 eV |
| Soft Ionization Range | 0–150 eV |
| Long-Term Stability | < ±0.5% peak height drift over 24 h |
| Detection Limit | ppm-level quantification |
| Shielding | Integrated radiation and magnetic shielding |
| Operational Mode | Dual-mode (conventional scanning + TIMS) |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | SIMS |
| Vacuum Compatibility | Ultra-High Vacuum (UHV) |
| Ion Sources | IG20 Ion Gun (differential pumping), IFG200 FAB Source, Liquid Gallium Liquid Metal Ion Gun (LMIG) |
| Detection Limit | <1 ppb (for selected elements under optimized conditions) |
| Sample Manipulator | 4-Axis (X, Y, Z, θ) UHV-Compatible |
| Charge Neutralization | Electron Flood Gun |
| Cryogenic Capability | Integrated Liquid Nitrogen Cold Trap |
| Vacuum System | Bakeable UHV Chamber with RGA Monitoring |
| Mass Analyzer | Hiden EQS Quadrupole Mass Spectrometer |
| Control & Acquisition Software | MASsoft Operating System with ESM LabVIEW Interface and SIMS Imaging Module |
| Compliance | Designed for GLP/GMP-adjacent surface analysis workflows |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | SIMS Workstation |
| Mass Analyzer Type | Quadrupole |
| Primary Beam Energy | 25 keV Ga⁺ |
| Mass Range | 1000 amu |
| Mass Resolution | 0.5 amu (5% valley between adjacent equal-height peaks) |
| Detection Mode | Pulsed Ion Counting (positive/negative ions) |
| Dynamic Range | 7 decades |
| Spatial Resolution | 50 nm (Ga⁺ beam), 100–150 µm (O₂⁺/Cs⁺ beams) |
| Vacuum System | UHV-compatible, three-stage differential pumping |
| Control Interface | Ethernet LAN, RS232, RS485 |
| Software | MASsoft v6.x (GLP-compliant audit trail, method templating, automated sequence execution) |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | Spaci-MS |
| Inlet Channels | 16 |
| Axial Travel Range | 0–300 mm |
| Spatial Resolution | 0.1 mm |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | SpaciMS |
| Inlet Channels | 16 |
| Axial Travel Range | 0–300 mm |
| Spatial Resolution | 0.1 mm |
| Application Domain | Catalytic Reactor Process Monitoring, Transient Gas Analysis, 3D Gas Composition Mapping |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | TGA-MS |
| Interface Type | Capillary Direct-Coupling Interface |
| Dead Volume | Minimized (< 10 µL) |
| Capillary Temperature Control | Up to 300 °C |
| Material of Construction | Inert (High-Purity Stainless Steel, SilcoNert®-treated Surfaces) |
| Gas Handling | Dual-Channel Mass Flow Controlled (H₂, He, N₂, Ar Compatible) |
| Flow Rate Range | 0.1–50 mL/min (Adjustable to Match TGA Effluent Profile) |
| Compliance | ASTM E2550, ISO 11358, USP <1210> |
| Brand | China Innovation Instrument |
|---|---|
| Origin | Zhejiang, China |
| Model | HIT-2210 |
| Ionization Mode | Dual-mode (Direct Ambient Ionization + LC-MS Coupling) |
| Detection Principle | Atmospheric Pressure Ionization Mass Spectrometry |
| Intended Use | Qualitative Identification, Semi-Quantitative & Quantitative Analysis |
| Regulatory Context | Designed for GLP-compliant laboratories and academic research environments |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | PP-TOFMS |
| Acquisition Rate | 1 spectrum per 30 µs |
| Mass Resolution | 5,000 (at m/z 208, high-resolution mode) |
| Dynamic Range | 10⁷ |
| Mass Accuracy | ±40 ppm |
| Sensitivity | 10³ cps/ppm |
| Depth Resolution | <1 nm |
| Ion Mode | Positive and Negative |
| Flexible Ion Blanking | Up to 4 ions |
| Sample Loading | Horizontal, ambient-pressure compatible |
| Mass Coverage | H to U, including isotopes and molecular species |
| Analysis Mode | Pulsed RF sputtering with 3D depth profiling capability |
| Quantification | Matrix-effect-reduced semi-quantitative analysis without calibration standards |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Domestic (China) |
| Model | HS-P5 |
| Instrument Type | Portable |
| Power Supply | Internal Rechargeable Battery or External DC Input |
| Sample Position Capacity | 5 Heated Vials |
| Compatibility | Designed for Coupling with BCT ER Series and P8800 Portable GC-MS Systems |
| Cleaning Function | Integrated Tubing Purge Cycle |
| Operational Mode | Headspace Equilibration with Pre-concentration Estimation Algorithm |
| User Interface | Embedded Control Software with Voice Guidance |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | HVE |
| Price | Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | iASAP Inert Gas Atmospheric Pressure Solid Analysis Probe |
| Instrument Type | APCI Ion Source |
| Application Scope | General-Purpose |
| Mass Range | 10–2000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine) |
| Resolution | 0.5–0.85 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Compliance | Compatible with Advion expression® CMS and compact CMS platforms |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ID Micro EA |
| Price Range | USD 140,000–280,000 |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Resolution | >75 at m/z 29 |