| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Y30 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min heating rate) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Y50 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (at ~100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Cooling Method | Forced-air convection |
| Display | 7-inch TFT high-definition color screen |
| Data Storage | 8 GB internal + microSD card (up to 128 GB) |
| Connectivity | USB 2.0, RS-232, Ethernet |
| User Accounts | 8 configurable roles with password protection |
| Compliance Standards | SNT 0801.5–1999, GB/T 24892–2010, GB/T 12766–2008 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Y90 |
| Price Range | USD 1,400–2,800 |
| Temperature Range | 4–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Brand | Yamato |
|---|---|
| Origin | Japan |
| Model | MP-21 |
| Temperature Range | 50–200 °C (with KF-96 100 cP silicone oil) / 90–300 °C (with KF-54 silicone oil) |
| Heating Rate | Adjustable via voltage control (0–98 V output) |
| Max. Temp. Ramp | ~250 °C from ambient in ≤15 min |
| Sample Capacity | 3 capillaries simultaneously |
| Stirring Motor | Capacitor-run, 2-pole, 3 W, high-speed rotation for uniform oil temperature distribution |
| Viewing System | 1.8× magnifying lens with 12 V / 10 W LED illumination |
| Bath Medium | 70 mL silicone oil (KF-54 or KF-96 100 cP) |
| Dimensions | Ø190 × H420 mm |
| Weight | ~6 kg |
| Compliance | Designed for JPC-compliant observation (not validated for JP XV official melting point determination per JP XV General Test 2.10) |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW X-4 / SGW X-4A / SGW X-4B |
| Temperature Range | Ambient to 320 °C |
| Heating Rate | 1 °C/min |
| Temperature Repeatability | ±1 °C (≤200 °C), ±2 °C (>200 °C) |
| Temperature Accuracy | ±1 °C (≤200 °C), ±2 °C (>200 °C) |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 1 |
| Viewing System | Monocular Microscope (X-4, X-4A) / Binocular Stereo Microscope (X-4B) |
| Magnification | 40× (X-4, X-4A), 40–100× (X-4B) |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Dimensions | 300 mm × 220 mm × 440 mm |
| Net Weight | 4.5 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW® X-4 |
| Temperature Range | Ambient to 330 °C |
| Heating Methods | Capillary Method & Hot Stage Method |
| Temperature Repeatability | ±1 °C at ≤200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Optical System | Monocular Microscope, 40× Magnification |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 215 × 140 × 395 mm |
| Net Weight | 3.5 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW® X-4A |
| Temperature Range | Ambient to 330 °C |
| Temperature Repeatability | ±1 °C at ≤200 °C, ±2 °C at >200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Viewing System | Monocular Microscope, 40× Magnification |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 215 × 140 × 395 mm |
| Net Weight | 3.6 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW® X-4B |
| Temperature Range | Ambient to 330 °C |
| Temperature Repeatability | ±1 °C at ≤200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Observation Method | Binocular Stereo Microscope |
| Magnification | 40×–100× (variable zoom) |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 269 × 160 × 435 mm |
| Net Weight | 4 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW® X-5 |
| Temperature Range | Ambient to 360 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min |
| Temperature Repeatability | ±0.3 °C (at 1.0 °C/min) |
| Temperature Accuracy | Capillary Method — ≤200 °C: ±0.4 °C |
| >200 °C | ±0.7 °C |
| Hot Stage Method — Ambient–100 °C | ±0.4 °C |
| 100–200 °C | ±0.6 °C |
| 200–300 °C | ±0.8 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 1 sample per run |
| Temperature Resolution | 0.1 °C |
| Display | 7-inch TFT capacitive touchscreen |
| Data Storage | 1000 measurement records |
| Interface | USB host/device (PC connectivity & USB flash drive support) |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 150 W |
| Dimensions (W×D×H) | 310 × 230 × 505 mm |
| Net Weight | 4.0 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®-630 |
| Temperature Range | Ambient to 400 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.2 °C/min), ±0.3 °C (at 1.0 °C/min) |
| Temperature Accuracy | ±0.4 °C (≤200 °C), ±0.7 °C (>200 °C) |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 3 capillaries |
| Calibration Points | 8-point |
| Data Storage | 16 GB internal |
| Display | 8-inch capacitive touchscreen |
| OS | Embedded Windows-based platform |
| Compliance | Meets USP <741>, EP 2.2.17, JP 2.60, FDA 21 CFR Part 11, GLP/GMP audit trail requirements |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®-650 |
| Temperature Range | Ambient to 400 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 5 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Calibration Points | 8-point programmable calibration |
| Data Storage | 16 GB internal |
| Display | 8-inch capacitive touchscreen LCD |
| Operating System | Embedded Windows-based platform |
| Compliance | Meets requirements of Chinese Pharmacopoeia, USP <741>, EP 2.2.17, ISO 11357-3, FDA 21 CFR Part 11 (audit trail, electronic signatures, role-based access control), GLP/GMP data integrity standards |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®-681 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20.0 °C/min (continuously adjustable) |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Repeatability | 0.3 °C at 1.0 °C/min |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 4 capillaries per run |
| Display | 10.1″ IPS capacitive touchscreen |
| Camera | 720p @ 30 fps |
| Data Storage | 64 GB internal |
| Operating System | Android-based embedded OS |
| Compliance | Compliant with USP <741>, EP 2.2.17, and ChP 0612 melting point determination methods |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®-682 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20.0 °C/min (continuously adjustable) |
| Temperature Accuracy | ≤200 °C ±0.4 °C |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 4 capillaries simultaneously |
| Display | 10.1″ IPS capacitive touchscreen |
| Camera | 720p @ 30 fps |
| Data Storage | 64 GB internal |
| Operating System | Android |
| Compliance Options | FDA 21 CFR Part 11 audit trail (optional), GLP/GMP-ready |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®-685 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (continuously adjustable) |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ≤200 °C: ±0.4 °C |
| >200 °C | ±0.7 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 4 capillaries |
| Temperature Resolution | 0.1 °C |
| Operating System | Android |
| Display | 10.1″ IPS capacitive touchscreen |
| Camera | 720p @ 30 fps |
| Data Storage | 128 GB internal |
| Connectivity | RS232, 3×USB, RJ-45, Wi-Fi |
| Power | 100–240 VAC, 50/60 Hz, 150 W |
| Dimensions | 320 × 295 × 190 mm |
| Net Weight | 3.7 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WQD-1A |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.2–5.0 °C/min (8 selectable steps) |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C (at calibration point) |
| Temperature Resolution | 0.1 °C |
| Capillary Tube Diameter | 1 mm (standard) |
| Sample Capacity | 1 position |
| Display | LCD |
| Power Supply | 220 V ±10%, 50 Hz, 100 W |
| Dimensions (Electronic Unit) | 400 × 300 × 160 mm |
| Dimensions (Detection Unit) | 155 × 110 × 230 mm |
| Net Weight | 10 kg |
| Compliance | Designed per ASTM D3461–97 |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WQD-360 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20 °C/min (continuously adjustable) |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Sample Capacity | 2 channels |
| Capillary Tube Size | 1 mm ID |
| Display | 10.1″ IPS capacitive touchscreen (720p) |
| Camera | Integrated 720p HD video module with real-time streaming and full-process recording |
| Data Storage | 64 GB internal |
| Operating System | Embedded Android |
| Compliance | ASTM D3461, ASTM D3104, ASTM D3954, ASTM D6090, Chinese Pharmacopoeia (2020 Ed.) Chapters for Drop Point & Softening Point |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WQD-400 |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.2–5 °C/min (8 discrete steps) |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Size | 1 mm ID |
| Sample Capacity | 2 simultaneous channels |
| Camera | 720p HD capacitive-touch-enabled imaging system |
| Display | 10.1″ IPS touchscreen |
| Data Storage | 128 GB internal |
| Compliance | ASTM D3461, ASTM D3104, ASTM D3954, ASTM D6090, Chinese Pharmacopoeia (2020 Ed.) |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRR |
| Temperature Range | Ambient to 280 °C |
| Heating Rates | 0.5, 1.0, 1.5, 3.0 °C/min (four fixed steps) |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 120 mm |
| Sample Capacity | 3 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Display | LCD |
| Interface | RS232/USB |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz, 100 W |
| Dimensions | 270 × 310 × 400 mm |
| Net Weight | 11 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRR-Y |
| Temperature Range | 40–90 °C (with water bath) / 60–280 °C (with silicone oil bath) |
| Heating Rates | 0.5, 1.0, 1.5, 3.0 °C/min (selectable) |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 120 mm |
| Sample Capacity | 3 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Display | LCD |
| Interface | RS232/USB |
| Power Supply | 220 V ±10%, 50 Hz, 200 W |
| Dimensions | 270 × 310 × 400 mm |
| Net Weight | 11 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1B, WRS-1C, WRS-2 |
| Temperature Range | Ambient to 320 °C |
| Heating Rate | 0.1–20.0 °C/min (continuously adjustable) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.4 °C |
| Capillary Dimensions | ID 1.0 mm, OD 1.4 mm, Length 90 mm |
| Sample Capacity | 3 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Data Storage (WRS-1C only) | Up to 1000 measurement records |
| Interface | USB and RS232 |
| Predefined Methods | 8 programmable profiles |
| Display | Color LCD touchscreen |
| Detection Principle | Photometric auto-detection of melt transition (transmittance change) |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1B |
| Temperature Range | Ambient to 320 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 selectable steps) |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 1 capillary per run |
| Display | 5.6-inch color LCD |
| Calibration | Multi-point calibration support |
| Interface | RS232 and USB |
| Power | 220 V ±10%, 50 Hz, 80 W |
| Dimensions | 360 × 290 × 170 mm |
| Net Weight | 9 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1C |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20.0 °C/min (continuously adjustable) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 1 capillary per run |
| Display | 5.7-inch graphical LCD with touch interface |
| Control System | Digital PID + PWM temperature regulation using Pt100 sensor |
| Data Storage | 1000 measurement records |
| Communication Interfaces | RS232 and USB |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 360 × 290 × 170 mm |
| Net Weight | 9 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1C |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (continuously adjustable) |
| Temperature Repeatability | ±0.3 °C (at 1 °C/min) |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 1 capillary per run |
| Display | 7-inch color TFT touchscreen |
| Data Storage | 1000 measurement records |
| Interface | RS232 and USB |
| Power Supply | 220 V ±10%, 50 Hz, 80 W |
| Dimensions | 360 × 290 × 170 mm |
| Net Weight | 9 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-2 |
| Temperature Range | Ambient to 300 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 selectable steps) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 1 capillary per run |
| Display | Dot-matrix LCD with numeric keypad input |
| Calibration | Multi-point platinum resistance (Pt100) calibration |
| Control Algorithm | PID temperature regulation |
| Interface | RS232 and USB |
| Power Supply | 220 V ±10 %, 50 Hz ±1 Hz |
| Dimensions | 360 × 290 × 170 mm |
| Net Weight | 9 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-2 |
| Temperature Range | Ambient to 300 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 selectable steps) |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 3 capillaries |
| Display | 5.6-inch color LCD |
| Interface | RS232 and USB |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz, 100 W |
| Dimensions | 360 × 290 × 170 mm |
| Net Weight | 9 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-2A |
| Temperature Range | Ambient to 300 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 fixed steps) |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 3 capillaries |
| Temperature Resolution | 0.1 °C |
| Display | 7-inch color LCD touchscreen |
| Calibration | Multi-point calibration |
| Interface | RS232 and USB |
| Power Supply | 220 V ±10 %, 50 Hz ±1 Hz, 100 W |
| Dimensions | 360 × 290 × 170 mm |
| Net Weight | 9 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-2C |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20 °C/min (continuously adjustable) |
| Temperature Repeatability | ±0.3 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 3 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Display | 7-inch color TFT touchscreen |
| Data Storage | 1000 test records |
| Interface | RS232 and USB |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz, 120 W |
| Dimensions | 360 × 290 × 170 mm |
| Net Weight | 9 kg |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-3A (Triple-Sample Configuration) |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–10.0 °C/min (continuously adjustable) |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ±0.5 °C ≤200 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 3 independent capillaries |
| Temperature Resolution | 0.1 °C |
| Display | 5.6-inch color TFT touchscreen |
| Data Storage | 100 measurement records |
| Interface | USB port and RS-232 serial interface |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz |
| Net Weight | 6 kg |
| Dimensions | 390 × 320 × 220 mm |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | WRX-2S |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.1–20 °C/min (continuously adjustable) |
| Temperature Repeatability | ±0.3 °C at 1.0 °C/min |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Diameter | 0.17 mm |
| Sample Capacity | 1 |
| Stage Dimensions | 195 mm × 28 mm × 85 mm |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 3,000 test records |
| Interface | USB 2.0 and RS232 |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 100 W |
| Net Weight | 9 kg (excluding microscope) |
| Brand | YDWO |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-2A |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 0.2–5.0 °C/min |
| Accuracy | ±0.5 °C below 200 °C |
| Sample Capacity | 3 positions (simultaneous measurement) |
| Display | LCD with real-time melting curve visualization |
| Input | Digital keypad |
| Detection Method | Photoelectric detection |