| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | M5000 |
| Temperature Range | 25–400 °C |
| Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Repeatability | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 4 min to 300 °C, 7.5 min to 400 °C |
| Capillary Diameter | 1.4 mm |
| Sample Capacity | 1 capillary per measurement |
| Cooling | Integrated fan-assisted cooling |
| Safety Rating | IP20 |
| Dimensions | 230 × 210 × 110 mm |
| Weight | 1.8 kg |
| Power Supply | 85–264 V AC, 47–440 Hz |
| Interface | RS-232 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | M3350-MFI |
| Temperature Range | 50–350 °C |
| Calibration Accuracy | ±0.1 °C |
| Temperature Stability | ±0.5 °C |
| Standard Load Masses | 1.2, 2.16, 3.8, 5, 10, 21.6 kg |
| Test Modes | MFR (Melt Flow Rate) and MVR (Melt Volume Rate) |
| Heating Zones | Dual-zone PID-controlled |
| Interface | RS-485 / RS-232 |
| Power Supply | 230 V / 50 Hz |
| Pneumatic Actuation | Dry air, 3 bar |
| Dimensions (L×W×H) | 60×30×40 cm |
| Weight | 15 kg |
| Software Compatibility | Windows 98/ME/2000/XP |
| Compliance | ASTM D1238, ISO 1133, GB/T 3682, USP <661>, DIN 53735 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55 / MP70 / MP80 / MP90 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Diameter Compatibility | <1.8 mm |
| Sample Capacity | Up to 6 samples simultaneously |
| Compliance | GLP/GMP-ready, ISO/IEC 17025-aligned calibration traceability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP70 / MP90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Sample Capacity | Up to 6 capillaries per run |
| Compliance | USP <741>, Ph. Eur. 2.2.14, JP 17, ISO 11357-3, ASTM D1519 |
| Safety | Integrated optical monitoring with simultaneous transmittance measurement and reflected-light imaging |
| User Interface | One Click® color touchscreen with pre-stored method recall |
| Qualification Support | Factory-supplied IQ/OQ documentation and on-site qualification services available |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1 to 20 °C/min |
| Temperature Accuracy | ±0.2 °C (30–200 °C), ±0.5 °C (200 °C to Tmax) |
| Sample Capacity | Up to 4 samples |
| Display | 5.7" VGA color touch screen |
| Video Resolution | Color AVI, >6× magnification |
| Data Export | PDF reports, GLP/GMP-compliant audit trail |
| Compliance | 21 CFR Part 11 ready (with LabX software) |
| Power Consumption | 120 W |
| Dimensions | 18 × 35 × 19 cm |
| Weight | 4.4 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP83/HT |
| Temperature Range | –25 to 375 °C |
| Temperature Accuracy | ±0.2 °C |
| Heating Rate | 0.1–20 °C/min |
| Dropping Point Orifice Diameter | 2.8 mm |
| Softening Point Orifice Diameter | 6.35 mm |
| Compliance | ASTM D3104-82, ASTM D3461-85, ASTM D3954, DIN 51920 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP900 |
| Temperature Range | −100 to 600 °C |
| Heating/Cooling Rate | 0–20 °C/min |
| Temperature Resolution | 0.1 °C |
| Sensor Type | PT100 |
| Display | Graphical LCD (60 × 256 pixels, 6 lines × 36 characters) |
| Method Storage | 15 preloaded + 35 user-defined methods |
| Compliance | ASTM, DIN, ISO, USP <741>, GLP/GMP-ready |
| Interface | RS232C |
| Measurement Units Support | °C, °F, K |
| Environmental Operating Range | 20–32 °C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55/80 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 4 °C/min (programmable) |
| Sample Capacity | 6 positions |
| Measurement Modes | Melting Point (MP), Melting Range (MR), Sliding Melting Point (SMP), Boiling Point (BP), Cloud Point (CP) |
| Video Recording Duration | 60 minutes |
| Maximum Results Storage | 50 entries |
| Compliance | USP <741>, Ph. Eur. 2.2.14, JP 17, ASTM D1565, ISO 4625 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP70 |
| Temperature Range | Room Temperature to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.2 °C (30–200 °C), ±0.5 °C (200–350 °C) |
| Capillary Diameter | <1.8 mm |
| Sample Capacity | 4 capillaries |
| Temperature Resolution | 0.1 °C |
| Cooling Time from Tmax | 7 min |
| Heating Time to Tmax | 5 min |
| GLP Compliance | Yes |
| Pharmacopoeial Compliance | Ph.Eur. 2.2.60, USP <741>, JIS K 0064, ASTM D1519 |
| Video Output | Color AVI, 6× digital zoom, SD card storage (up to 300 min), real-time recording |
| Data Export | PDF reports, MS Excel-compatible intensity data, method & result archiving |
| Method Storage | Up to 20 user-defined methods |
| Reference Substance Database | Up to 5 substances |
| User Authentication | Yes |
| One-Click™ Presets | Up to 12 per user |
| IQ/OQ Documentation | Available as optional service |
| Barcode Scanner Interface | USB |
| Printer Support | USB-P25 compact printer, PCL-compatible Ethernet printers |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MP90 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | Programmable (5 min to Tmax from 50 °C) |
| Cooling Time (Tmax to 50 °C) | 6 min |
| Capillary Capacity | 6 melting point capillaries per run |
| Sample Throughput | Up to 12 measurements per user session |
| Display | 7-inch full-color touchscreen |
| Video Resolution | High-definition color video recording (300 min total storage) |
| Data Export | SD card, USB drive, or direct PC connection |
| Compliance | 21 CFR Part 11 and EU Annex 11 (with LabX software) |
| Audit Trail | Available via LabX software |
| Report Format | PDF (60 stored reports) |
| Reference Substance Library | 100 entries |
| Dimensions (W × H × D) | 18 × 35 × 19 cm |
| Weight | 4 kg |
| Language Support | English, Chinese, German, Spanish, French, Italian, Portuguese, Russian, Japanese, Korean |
| Brand | Stanford |
|---|---|
| Origin | USA |
| Model | MPA100 |
| Temperature Range | +10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.3 °C (@ ~100 °C), ±0.5 °C (@ ~250 °C), ±0.8 °C (@ ~400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Temperature Resolution | 0.1 °C |
| Power Supply | AC 90–264 V |
| Weight | 4.1 kg |
| Operating Ambient | 0–40 °C |
| Interface | USB, RS-232 |
| Software | MeltView (Windows-compatible) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP-3A |
| Pricing | Upon Request |
| Max Temperature | 1000 °C |
| Temperature Accuracy | ±1 °C |
| Heating Rate | 25 °C/min |
| Probe Travel Range | 0–3 mm |
| Probe Resolution | 0.0025 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WRS-1B |
| Price | USD 1,700 (FOB Shanghai) |
| Temperature Range | Ambient to 300 °C |
| Minimum Display Resolution | 0.1 °C |
| Linear Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 selectable rates) |
| Accuracy | ±0.5 °C below 200 °C |
| Weight | 11 kg |
| Dimensions | 398 × 280 × 170 mm |
| Interface | RS-232 serial port |
| Data Output | Automatic onset/melting end calculation with mean value reporting |
| Display | Backlit LCD with real-time melting curve visualization |
| Detection Method | Photoelectric detection of solid–liquid phase transition |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WRS-2A |
| Price | USD 2,500 (FOB Shanghai) |
| Melting Point Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Linear Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 selectable rates) |
| Accuracy | ±0.5 °C below 200 °C |
| Sample Capacity | 3 simultaneous capillary samples |
| Data Output | RS232 serial interface |
| Net Weight | 11 kg |
| Dimensions | 398 × 280 × 170 mm |
| Display | Backlit LCD with real-time melting curve visualization |
| Input Method | Numeric keypad |
| Detection Principle | Photometric (transmittance-based) capillary melt detection |
| Brand | YDWG (Shanghai Physical Optics) |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-4 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | Adjustable, up to 320 °C |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ≤±1 °C (<200 °C) |
| Capillary Tube Length | 90 mm |
| Sample Capacity | 1 sample |
| Temperature Resolution | 1 °C |
| Display | LED digital readout (0.1 °C minimum increment) |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 80 W |
| Optical Configuration | Binocular stereomicroscope with 45° inclined dual eyetubes, adjustable interpupillary distance and right-eye diopter compensation |
| Total Magnification | 40× (4× objective + 10× eyepiece) |
| Working Distance | Optimized for thermal stage integration |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-4A |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.5–20 °C/min |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ±0.5 °C |
| Capillary Dimensions | OD Φ1.4 mm, ID Φ0.9 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-5 |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ±0.5 °C (<200 °C), ±1 °C (≥200 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 0.9 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Brand | YDWG (Shanghai Physical Optics) |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-2A |
| Temperature Range | Ambient to 300 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 selectable steps) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.4 °C ≤200 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, Length 90 mm |
| Sample Capacity | 3 capillaries per run |
| Display | Dot-matrix LCD with keypad input |
| Calibration | Multi-point PT100-based calibration |
| Interface | RS232 and USB |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 360 × 290 × 170 mm |
| Net Weight | 9 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Opti-Melt100 |
| Price | ¥56,500 (CNY) |
| Temperature Range | −10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min (adjustable in 0.1 °C/min increments) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.3 °C (≤100 °C), ±0.5 °C (≤250 °C), ±0.8 °C (≤400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Sample Capacity | 2 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Heating Time | 10 min (50 °C → 350 °C) |
| Cooling Time | 10 min (350 °C → 50 °C) |
| Display | Touchscreen LCD |
| Interface | USB, RS-232 |
| Software | Melt-View™ (Windows-compatible) |
| Power Supply | AC 90–264 V |
| Operating Temperature | 0–40 °C |
| Weight | 4.1 kg |
| Dimensions | 20 × 25 × 21 cm |
| Brand | SRS / Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | OptiMelt MPA100 |
| Temperature Range | RT+10°C to 400°C |
| Heating Rate | 0.1–20.0°C/min (0.1°C/min increments) |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.3°C (≤100°C), ±0.5°C (≤250°C), ±0.8°C (≤400°C) |
| Temperature Repeatability | ±0.3°C |
| Capillary Dimensions | OD 1.4–2.0 mm, Length 100 mm |
| Sample Capacity | 3 channels simultaneously |
| Cooling Time | 10 min (350°C → 50°C) |
| Heating Time | 10 min (50°C → 350°C) |
| Display | Touchscreen LCD |
| Interface | USB, RS-232 |
| Software | MeltView™ for Windows |
| Power | 90–264 VAC |
| Weight | 4.1 kg |
| Dimensions | 20 × 25 × 21 cm |
| Brand | SRS |
|---|---|
| Origin | USA |
| Model | MPA100 |
| Temperature Range | Ambient to 396 °C |
| Heating Rate | 0.1–20.0 °C/min (in 0.1 °C/min increments) |
| Temperature Repeatability | ±0.2 °C |
| Temperature Accuracy | ±0.3 °C (up to 100 °C), ±0.5 °C (up to 250 °C), ±0.8 °C (up to 400 °C) |
| Capillary Dimensions | OD 1.4–2.0 mm, Length 100 mm |
| Sample Capacity | 3 capillaries |
| Temperature Resolution | 0.1 °C |
| Brand | Stuart |
|---|---|
| Origin | UK |
| Model | SMP10 |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 1 °C |
| Accuracy | ±1.0 °C at 20 °C, ±2.5 °C at 300 °C |
| Heating Rate | 20 °C/min (pre-heat), 2 °C/min (melting determination) |
| Display | 3-digit LED |
| Sensor | PT100 platinum resistance thermometer |
| Sample Capacity | 2 capillaries simultaneously |
| Dimensions (W×D×H) | 160 × 220 × 170 mm |
| Net Weight | 1.8 kg |
| Power Supply | 230 V / 50 Hz, 75 W |
| Includes | 100 sealed-end capillary tubes (SMP10 kit) |
| Brand | Stuart |
|---|---|
| Origin | USA |
| Model | SMP10 |
| Temperature Range | Ambient to 300°C |
| Heating Rate | 2°C/min |
| Temperature Accuracy | ±1°C |
| Capillary Length | 100 mm |
| Sample Capacity | 2 samples |
| Brand | Stuart |
|---|---|
| Origin | United Kingdom |
| Model | SMP30 |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 0.5–10.0 °C/min (adjustable in 0.1 °C increments) |
| Cooling Time (350 °C → 50 °C) | 12 min |
| Heating Time (50 °C → 350 °C) | 6 min |
| Sample Capacity | 3 capillaries simultaneously |
| Temperature Memory | 8 readings per sample |
| Display | 40×4 character LCD |
| Sensor | PT100 platinum resistance thermometer |
| Power Supply | 230 V, 50 Hz, 60 W |
| Dimensions (W×D×H) | 325 × 200 × 170 mm |
| Net Weight | 3.6 kg |
| Capillary Storage Compartment | Integrated |
| Observation Chamber | Dual-height adjustable |
| Illumination | Integrated high-intensity LED lighting |
| Surface Finish | Biocote® antimicrobial coating |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMP30 |
| Price Range | USD 1,400–2,800 |
| Sample Capacity | 3 capillaries |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.5–10.0 °C/min (0.1 °C increments) |
| Temperature Memory | 8 readings per sample |
| Sensor | PT100 platinum resistance thermometer |
| Cooling | Integrated air pump |
| Dimensions | 325 × 200 × 170 mm |
| Net Weight | 3.6 kg |
| Power Supply | 230 V, 50/60 Hz, 60 W |
| Standard Accessories | Glass capillary tubes (SMP10/1) |
| Brand | Stuart |
|---|---|
| Origin | United Kingdom |
| Model | SMP40 |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 0.1–10 °C/min (adjustable in 0.1 °C increments) |
| Cooling Time (350 °C → 50 °C) | ≤10 min |
| Heating Time (50 °C → 350 °C) | ≤6 min |
| Sample Capacity | 3 capillaries simultaneously |
| Display | 5.7″ color VGA touchscreen |
| Sensor | PT100 platinum resistance thermometer |
| Data Storage | 200 measurement records with embedded AVI video |
| Compliance | Pharmacopoeial standards (USP <741>, EP 2.2.14, JP 2.60), GLP-ready, includes traceable calibration certificate |
| Dimensions (W×D×H) | 175 × 210 × 328 mm |
| Net Weight | 3.2 kg |
| Power Supply | 230 V / 50 Hz / 60 W |
| Capillary Storage Compartment | Yes |
| Glass Tool Storage Compartment | Yes |
| Antimicrobial Surface Coating | Biocote® silver-ion technology |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMP40 |
| Price Range | USD 4,200–7,000 (est.) |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–10.0 °C/min (adjustable in 0.1 °C increments) |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Capillary Length | 100 mm |
| Sample Capacity | 3 samples simultaneously |
| Temperature Resolution | 0.1 °C |
| Cooling Time (350 °C → 50 °C) | ≤10 min |
| Heating Time (50 °C → 350 °C) | ≤6 min |
| Display | 5.7″ color VGA touchscreen |
| Sensor | PT100 platinum resistance thermometer |
| Data Storage | 200+ test records with full AVI video capture |
| Power Supply | 230 V / 50 Hz, 60 W |
| Dimensions (W×D×H) | 175 × 210 × 328 mm |
| Net Weight | 3.2 kg |
| Brand | Stuart |
|---|---|
| Origin | United Kingdom |
| Model | SMP50 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Capillary Dimensions | 100 mm total length, 1.9 mm OD, 1.3 mm ID, 0.3 mm wall thickness |
| Sample Capacity | 3 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Control Sensor | PT1000 platinum resistance thermometer |
| Heating/Cooling Time | 6 min (50 → 350 °C), 12 min (350 → 50 °C) |
| Display | 7-inch high-resolution capacitive touchscreen |
| Operating System | Android-based embedded UI |
| Onboard Storage | 8 GB flash memory (≈300 full video + metadata records) |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions (H×D×W) | 164 × 360 × 300 mm |
| Net Weight | 4.6 kg |
| Compliance | USP <741>, EP 2.2.17, JP 2.60, GLP-aligned design, FDA 21 CFR Part 11 ready (with optional IQ/OQ documentation package) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | JH50, JH70, JH90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step adjustable) |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per batch |
| Display | TFT high-definition color LCD |
| Data Storage | 8 GB internal |
| Image Capture | Still frame capture with real-time video streaming |
| Video Playback | Local playback supported |
| Connectivity | USB, RS-232, Ethernet |
| Power Supply | 220 VAC, 50 Hz, 120 W |
| Magnification | 7× optical |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | Y70 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |