Melting Point Apparatus
Filter
Showing 31–60 of 125 results
| Brand | Electrothermal |
|---|---|
| Origin | United Kingdom |
| Model | IA9100 |
| Temperature Range | Ambient to 400°C |
| Heating Rate | 1.0°C/min |
| Temperature Accuracy | ±0.5°C (±1.0°C at 350°C) |
| Temperature Resolution | ±0.1°C |
| Capillary Outer Diameter | ≤2 mm |
| Sample Capacity | 3 capillaries simultaneously |
| Brand | G-WON |
|---|---|
| Origin | USA |
| Model | MPA100 |
| Temperature Range | −10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min (adjustable in 0.1 °C/min increments) |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C at ≤100 °C, ±0.5 °C at ≤250 °C, ±0.8 °C at ≤400 °C |
| Temperature Repeatability | ±0.1 °C |
| Capillary Dimensions | OD 1.4–2.0 mm, length 100 mm |
| Sample Capacity | 3 channels simultaneously |
| Cooling Time | 10 min (350 °C → 50 °C) |
| Heating Time | 10 min (50 °C → 350 °C) |
| Display | Touch-enabled LCD panel |
| Interface | USB 2.0, RS-232 serial port |
| Software | MeltView™ for Windows (USB-connected), supports GLP-compliant data logging and audit trail |
| Power Supply | AC 90–264 V, 50/60 Hz |
| Operating Environment | 0–40 °C, <80% RH non-condensing |
| Dimensions | 20 × 25 × 21 cm |
| Weight | 4.1 kg |
| Brand | GLTLab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MPD-02 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 20 °C/min |
| Temperature Repeatability | ±0.5 °C |
| Temperature Accuracy | ±0.1 °C |
| Capillary Diameter | 2 mm |
| Sample Capacity | 3 samples per run |
| Temperature Resolution | 0.1 °C |
| Power Supply | 120/230 V AC, 50 Hz, 75 W |
| Dimensions (W×D×H) | 160 × 220 × 170 mm |
| Net Weight | 1.8 kg |
| Display | 4-digit LED |
| Calibration Function | Yes |
| Visual Observation System | Integrated LED illumination, adjustable magnifier with inclined viewing stage |
| Brand | GLTlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MPD-03 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 20 °C/min |
| Temperature Repeatability | ±0.5 °C |
| Temperature Accuracy | ±0.1 °C |
| Capillary Diameter | 2 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Display | 4-digit LED |
| Calibration Function | Yes |
| Hold Temperature Function | Yes |
| Dimensions (W×D×H) | 160 × 220 × 170 mm |
| Net Weight | 2 kg |
| Power Supply | 120/230 V AC, 50 Hz, 75 W |
| Brand | GLTlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | MPD03-SS |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 20 °C/min |
| Temperature Repeatability | ±0.5 °C |
| Temperature Accuracy | ±0.1 °C |
| Capillary Diameter | 2 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Display | 4-digit LED |
| Calibration Function | Yes |
| Data Logging | No |
| Dimensions (W×D×H) | 160 × 220 × 170 mm |
| Net Weight | 2 kg |
| Power Supply | 120/230 V, 50 Hz, 75 W |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP360 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.3 °C |
| Capillary Dimensions | ID 0.9–1.1 mm, Wall Thickness 0.10–0.15 mm (optional 1.6 mm OD) |
| Sample Capacity | 3 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 32 GB internal |
| Video Storage | ~10,000 minutes (H.264 encoded) |
| Compliance | FDA 21 CFR Part 11, ASTM D3104, GB/T 24892–2010, GB/T 12766–2008, SN/T 0801.5–1999 |
| Connectivity | USB ×3, RS-232, Wi-Fi, RJ45 Ethernet |
| Calibration | Multi-point temperature calibration |
| User Management | Role-based access control with audit trail |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP420 |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Data Storage | 16 GB internal (expandable via USB) |
| Compliance | FDA 21 CFR Part 11 (audit trail, user permission tiers, password policy, electronic signature support) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP430 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Camera | 720p HD, 8× optical zoom |
| Display | 8-inch capacitive TFT touchscreen running Android OS |
| Data Storage | Up to 128 GB (supports USB backup/restore) |
| Connectivity | Wi-Fi, USB ×3, RS-232, RJ45 |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready user management & electronic signature support |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP450 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 128 GB internal (≥40,000 min video archive) |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Connectivity | USB ×3, RS-232, Wi-Fi, RJ45 Ethernet |
| Cooling | Ambient to 50 °C in ≤7 min |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP470 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | ID 1.0 mm × OD 1.4 mm |
| Sample Capacity | 4 samples per run |
| Dual TFT Color Displays | 5.6″ + 3.5″ |
| Video Magnification | 7× |
| Data Storage | Up to 1000 test records, 16 GB SD card support |
| Compliance | FDA 21 CFR Part 11 (electronic signatures, audit trail, user-level access control), GLP-ready architecture |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP470 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Data Storage | Up to 128 GB (≥40,000 min video archive) |
| Connectivity | USB ×3, RS232, Wi-Fi, RJ45 |
| Video | 720p, 8× optical zoom, real-time watermarking (timestamp + temperature), synchronized thermal profile playback |
| Calibration | Up to 6-point certified reference material calibration |
| Compliance | FDA 21 CFR Part 11 audit trail, user role-based access control (Admin/Supervisor/Operator/IT), password aging & complexity policies, screen lock timeout |
| Brand | Hanon |
|---|---|
| Origin | Shanghai, China |
| Model | MP490 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.01 °C |
| Data Storage | 128 GB internal (≥40,000 min video capacity) |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready |
| Brand | HJ |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RD-1 |
| Melting Point Range | Ambient to 270 °C |
| Heating Rates | 0.5 °C/min, 1.0 °C/min, 1.5 °C/min, 3.0 °C/min (selectable) |
| Linearity Deviation of Heating Rate | < 5% |
| Temperature Accuracy | ±0.5 °C ≤ 200 °C |
| Temperature Resolution | 0.1 °C |
| Thermal Medium | Methyl Silicone Oil |
| Bath Vessel | 250 mL Tall-Form Beaker |
| Operating Ambient Temperature | 18–28 °C |
| Interface | RS-232 Serial Port with Integrated Thermal Microprinter |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 200 mm × 320 mm × 305 mm |
| Control Modes | Reset / Temperature Hold / Auto Test Initiation |
| Pre-set Temperature Memory | Non-volatile retention across power cycles |
| Equilibration Delay | ~60 s after target temperature reached, confirmed by audible alert |
| Endpoints | Manual initiation of onset (initial melt) and offset (complete melt) recording via dedicated front-panel keys |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS302 |
| Temperature Range | −190 °C to 400 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C at 100 °C |
| Max Heating Rate | +100 °C/min at 100 °C |
| Max Cooling Rate | −100 °C/min at 100 °C |
| Min Working Distance | 3.3 mm (outer window removed) |
| Operating Working Distance | 5.6 mm |
| Condenser Distance | 10.0 mm |
| Sample Area | 38 mm × 50 mm |
| Chamber Height | 2.0–12.5 mm (with optional spacers) |
| Viewing Aperture Options | 2 / 5 / 8 / 10 mm |
| Optional X-Y Micropositioner | 10 µm resolution |
| Temperature Sensor | 100 Ω Platinum RTD |
| Control Method | Switching PID (LVDC PID optional) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J30 |
| Price | USD 1,650 (FOB Shanghai) |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (≥250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 positions |
| Temperature Resolution | 0.1 °C |
| Display | 7-inch TFT true-color LCD |
| Data Storage | 200 test records (8 GB internal flash) |
| Video Magnification | 7× |
| Interface | USB 2.0, RS-232, 10/100 Mbps Ethernet |
| Power Supply | 220 V AC, 50 Hz, 120 W |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | J350 |
| Price Range | USD 1,400–2,800 (FOB) |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Temperature Repeatability | ±0.2 °C (typical, per ASTM E928-21) |
| Temperature Accuracy | ±0.3 °C (calibrated against NIST-traceable reference standards) |
| Temperature Resolution | 0.1 °C |
| Slide Dimensions | 76 × 19 × 1 mm (standard microscope slide), Coverslip: 15 × 15 × 0.5 mm |
| Field of View | 2 mm diameter |
| Working Distance (objective lens) | ≥7 mm |
| X–Y Translation Range | ≤13 mm |
| Dimensions (L×W×H) | 185 × 85 × 28 mm |
| Weight | 1.0 kg |
| Display | 4.3″ TFT true-color touchscreen |
| Interfaces | USB 2.0, RS-232, SD card slot, Ethernet (optional) |
| Method Storage | 10 pre-programmed thermal protocols |
| Data Logging Capacity | 200 complete thermal event records |
| User Management | None (single-user operation) |
| Segment Control | Single-ramp profile only |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | J370 |
| Price Range | USD 1,400–2,800 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | Not specified |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Slide Dimensions | 76 × 19 × 1 mm / 15 × 15 × 0.5 mm |
| Field of View | 2 mm |
| Working Distance (Objective) | ≥7 mm |
| X–Y Translation Range | ≤13 mm |
| Dimensions (L×W×H) | 185 × 85 × 28 mm |
| Weight | 1 kg |
| User Profiles | 15 |
| Method Segments | 99 per method |
| Stored Methods | 20 |
| Data Storage Capacity | 400 test records |
| Interface Ports | USB, RS232, SD card slot, Ethernet |
| Display | TFT high-definition color LCD |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J40 |
| Price Range | USD 7,000–14,000 (FOB) |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min heating rate |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 2 positions (dual-channel simultaneous analysis) |
| Temperature Resolution | 0.1 °C |
| Display | TFT high-definition color LCD |
| Power Supply | 220 V AC, 50 Hz, 120 W |
| Data Interfaces | USB, RS-232, Ethernet |
| User Accounts | 8 configurable profiles |
| Melting Curve Storage | 10 full thermal profiles |
| Data Log Capacity | 200 test records |
| Detection Mode | Fully automated optical endpoint detection only (no manual override) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J50 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Storage | 8 GB internal flash memory |
| Data Storage Capacity | Up to 400 melting thermograms |
| Imaging | HD video capture module with 7× optical magnification |
| Display | TFT high-definition color touchscreen |
| Power Supply | 220 V AC, 50 Hz, 120 W |
| Interfaces | USB, RS-232, Ethernet |
| Operation Mode | Semi-automatic (automated temperature control, manual endpoint detection) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J60 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min heating rate) |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Display | TFT high-definition color LCD |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 120 W |
| Data Interfaces | USB, RS-232, Ethernet |
| User Accounts | 8 configurable profiles |
| Melting Curve Storage | 10 complete thermal profiles |
| Total Data Storage | 400 melting events |
| Detection Mode | Fully automated optical detection (no manual override) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J70 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 8 GB internal flash |
| Image Storage | 400 frames |
| Video Recording | Yes (TFT-displayed real-time capture) |
| User Accounts | 8 configurable profiles |
| Display | TFT high-definition true-color LCD |
| Interface | USB, RS-232, Ethernet |
| Power | 220 V AC, 50 Hz, 120 W |
| Magnification | 7× optical |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J80 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min ramp rate |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 16 GB internal |
| Melting Curve Records | 600 traces |
| Video Recordings Stored | 20 full sequences |
| User Accounts | 10 configurable profiles |
| Imaging | High-definition CMOS video module (7× optical magnification) |
| Display | TFT true-color touchscreen |
| Connectivity | USB, RS-232, Ethernet |
| Power | 220 V AC, 50 Hz, 120 W |
| Operating Modes | Fully automated + manual override |
| Preloaded Methods | 40 validated protocols |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J90 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 420 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 32 GB internal SSD |
| Image/Video Storage | Up to 1,000 frames + 80 complete melting profiles |
| User Accounts | 20 configurable roles with password protection |
| Operating Interface | 7-inch TFT full-color touchscreen |
| Connectivity | USB 2.0, RS-232, Ethernet |
| Optical Magnification | 7× |
| Integrated Thermal Printer | Yes |
| Reference Standard Set Included | Yes |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JH Series |
| Price Range | USD 7,000 – 14,000 |
| Temperature Range | Ambient to 100 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 0.1–10 °C/min |
| Cooling Method | Forced Air |
| Temperature Accuracy | ±0.2 °C at ~100 °C |
| Temperature Sensor | Platinum RTD (Pt100) |
| Optical Detection | High-Resolution Digital Imaging Sensor |
| Sample Capacity | 2 capillaries simultaneously |
| Capillary Dimensions | OD 4 mm, L 120 mm |
| Interface | USB 2.0 |
| Power Supply | AC 220 V, 50/60 Hz |
| Operating Ambient | 5–35 °C |
| Net Weight | 4.1 kg |
| Compliance | GB/T 24892–2010, GB/T 12766–2008, SN/T 0801.5–1999, ISO 6320:2017 (Edible Fats and Oils — Determination of Melting Point) |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JHD70 |
| Price Range | USD 4,200 – 7,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Sample Capacity | 4 capillaries per run (2 simultaneously analyzed) |
| Display | Dual-color LCD (3.5″ + 5.6″), >2.5× optical magnification |
| User Accounts | 15 |
| Predefined Methods | 100 |
| Data Interfaces | USB, RS232, Ethernet |
| GLP Compliance | Yes |
| Power Supply | 220 V, 50 Hz, 120 W |
| Standards Compliance | ASTM D3204, D3461, D3954, D6090 |
| Brand | Jihepu |
|---|---|
| Origin | Shandong, China |
| Model | WRS-1B |
| Temperature Range | 30–300 °C |
| Programmable Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min |
| Temperature Resolution | ±0.4 °C (≤200 °C), ±0.7 °C (200–300 °C) |
| Repeatability | ≤0.3 °C at 1.0 °C/min |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 3 capillaries simultaneously |
| Power Supply | 220 V ±10%, 50 Hz, 100 W |
| Dimensions (W×D×H) | 398 × 278 × 210 mm |
| Net Weight | 12.5 kg |
| Brand | Jihepu |
|---|---|
| Model | WRS-3 |
| Temperature Range | Ambient to 320 °C |
| Heating Rate Options | 0.2, 1.0, 1.5, 3.0 °C/min |
| Temperature Resolution | ±0.5 °C |
| Temperature Accuracy | ±0.5 °C (≤200 °C), ±0.8 °C (200–300 °C) |
| Temperature Repeatability | 0.3 °C at 1.0 °C/min |
| Capillary Dimensions | OD 1.2 mm, ID 1.0 mm, Length 120 mm |
| Sample Capacity | 3 positions |
| Power Supply | AC 220 V ±10%, 50 Hz, 100 W |
| Interfaces | RS232, USB |
| Display | Touchscreen LCD |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | Kofler HB |
| Type | Hot-block melting point apparatus |
| Principle | Kofler hot-plate method (linear temperature gradient) |
| Application | Rapid qualitative and semi-quantitative melting point determination of organic crystalline solids |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | KSP1D / KSP1N |
| Temperature Range | 30–360 °C |
| Accuracy | ±0.3 °C (30–200 °C), ±0.5 °C (200–360 °C) |
| Heating Rate | 1 °C/min |
| Optical Magnification | 10× |
| Capillary Capacity | 3 capillaries |
| Capillary Dimensions | 80 mm length × 1.4 mm OD × 0.8 mm ID |
| Cooling | Integrated fan-assisted rapid cooling |
| Display | Backlit LCD with real-time temperature and status |
| Interface | RS-232 |
| Power Supply | 90–264 V AC, 40 W |
| Safety Rating | IP20 |
| Weight | 2.3 kg |
| Language Support | English & German (UI + error messages) |
| Printer | Built-in thermal printer (KSP1D only) |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | M3000 & M5000 |
| Temperature Range | 25–400 °C |
| Heating Rate | 4 min to 300 °C, 7.5 min to 400 °C |
| Temperature Repeatability | ±0.2 °C |
| Temperature Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Capillary Dimensions | 1.4 mm OD |
| Sample Capacity | 1 capillary per measurement |
| Temperature Resolution | 0.1 °C |
| Optical Magnification | 10× |
| Cooling | Integrated fan-assisted rapid cooling |
| Display | Backlit LCD with real-time temperature and status |
| Interface | RS-232 |
| Power Supply | 90–264 V AC, 40 W |
| Ingress Protection | IP20 |
| Weight | 2.3 kg |