- All
- Favorite
- Popular
- Most rated
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–3500 µm |
| Repeatability | <0.04% |
| Measurement Time | ≤10 s |
| Optical Model | Fraunhofer and Mie Theory |
| Maximum Obscuration | 50% |
| Dispersant Compatibility | Organic solvents, aqueous media, corrosive liquids |
| Ultrasonic Power | 60 W, continuously adjustable |
| Circulation Pump | Variable-speed centrifugal pump |
| Sample Volume | 250–1000 mL |
| Integrated Cleaning Cycle | Fully automated with liquid-level monitoring |
| Optional Temperature Control | Up to 100 °C |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | NIMBUS |
| Pricing | Upon Request |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer | Sympatec GmbH |
| Model | NANOPHOX CS |
| Particle Size Range | 0.5–10,000 nm |
| Repeatability | <2% |
| Temperature Control Range | 0–90 °C |
| Temperature Stability | ±0.1 °C |
| Measurement Principle | Polarization-Split Backscattering Photon Cross-Correlation Spectroscopy (PCCS) |
| Sample Concentration Range | 0.01–70 vol.% |
| Sample Volume | 50 µL–4 mL |
| Measurement Time | <1–3 min |
| Detection Method | PCCS & PCS dual-mode |
| Laser | 660 nm diode, Class 1, 30 mW (software-adjustable) |
| Correlator | Multi-channel, 30 ns minimum sampling time |
| Data Interface | TCP/IP |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Laboratory Laser Particle Size Analyzer |
| Model | HELOS & OASIS |
| Dispersion Method | Dry and Wet |
| Measurement Range | 0.1–3500 µm |
| Repeatability | 0.04% |
| Measurement Time | <10 s |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Dynamic Image-Based Particle Analyzer |
| Model | QICPIC & GRADIS |
| Lens Count | 5 |
| Measurement Range | 1.8–33,792 µm |
| Dispersion Method | Free-Fall Gravity Dispersion |
| Image Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter (ECD), Circularity (Sphericity), Aspect Ratio, Convexity, Flatness, Elongation, LEFI, DIFI, VBFD, PED |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Imported Industrial-Grade Dynamic Image Analyzer |
| Model | QICPIC & FLOWCELL |
| Optical Configuration | Dual-lens imaging system |
| Measurement Range | 11–16,000 µm |
| Dispersion Method | Wet dispersion via external recirculation |
| Image Resolution | 4.2 MP (high-fidelity monochrome CMOS sensors) |
| Measured Parameters | Chord length, Feret diameters (max/min/mean), fiber length & diameter, equivalent circular diameter (ECD), sphericity, aspect ratio (width-to-length), convexity, flatness, elongation, LEFI/DIFI/VBFD indices, projected area diameter (PED) |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Dynamic Image-Based Particle Analyzer |
| Model | QICPIC & LIXELL |
| Lens Count | 6 |
| Measurement Range | 1–2000 µm |
| Dispersion Method | Wet Dispersion (External Circulation) |
| Image Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter (ECD), Sphericity, Aspect Ratio, Convexity, Flatness, Elongation, Light Extinction Feret Index (LEFI), Dynamic Image Feret Index (DIFI), Volume-Based Feret Diameter (VBFD), Projected Area Diameter (PED) |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | HELOS & CUVETTE |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.1–3500 µm |
| Repeatability | < 0.04% |
| Measurement Time | 10 s |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.1–875 µm |
| Repeatability | <0.04% RSD |
| Measurement Time | 10 s |
| Dispersion Method | Fully Automated Wet Dispersion (Closed-Circuit Circulation) |
| Ultrasonication | 60 W, Adjustable Power & Duration |
| Mechanical Stirring | Dual Agitators with Variable Speed Control |
| Pump | Precision Peristaltic Circulation Pump, Flow Rate Adjustable |
| Sample Cell Volume | 500 mL (Optional SVA Micro Cell: 50 mL) |
| Compliance | FDA 21 CFR Part 11 Ready Software, GLP/GMP Support Enabled |
| Construction | Full Stainless Steel Housing & Fluid Path |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer | Sympatec GmbH |
| Product Type | Imported Instrument |
| Model | NANOPHOX/R |
| Particle Size Range | 0.5–10,000 nm |
| Measurement Principle | Photon Cross-Correlation Spectroscopy (PCCS) |
| Temperature Control Range | 0–90 °C |
| Temperature Stability | ≤ 0.1 °C |
| Optical Signal Resolution | 30 ns |
| Sample Volume Range | 50 µL–4 mL |
| Concentration Tolerance | up to 70 vol.% (sample-dependent) |
| Light Source | 658 nm semiconductor laser, 30 mW output, software-adjustable power |
| Laser Class | Class 1 |
| Detection System | Dual PMT detectors with independent signal acquisition |
| Correlator Architecture | Multi-channel digital correlator with real-time cross-correlation processing |
| Data Acquisition Interface | TCP/IP |
| Sample Compatibility | Aqueous & organic suspensions, emulsions, microemulsions, fluorescent and colored samples |
| Measurement Time | 2–5 min per run |
| Software Compliance | Supports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer | Sympatec GmbH |
| Type | Import |
| Model | QICPIC & RODOS/L |
| Instrument Category | Dynamic Image-Based Particle Analyzer |
| Number of Lenses | 5 |
| Measurement Range | 1.8–33,792 µm |
| Dispersion Method | Pneumatic (Compressed Air) |
| Image Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter, Sphericity, Aspect Ratio, Convexity, Flatness, Elongation, Perimeter-Weighted Diameter (PED), Length-to-Width Ratio (L/W), VBFD (Volume-Based Fiber Dimension), LEFI/DIFI |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Product Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Model | HELOS & SPRAYER |
| Dispersion Method | Dry and Wet |
| Measurement Range | 0.25–1750 µm |
| Repeatability | Application-dependent |
| Measurement Duration | 10 s per acquisition |
| Compatible Actuator | SMACTOR Intelligent Trigger System |
| Optional Accessory | ROTOR Angular Positioning Fixture |
| Compliance Context | Designed to support FDA guidance on nasal spray characterization (e.g., Q5A(R2), Q5C, and relevant sections of USP <601> and <1601>) |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer | Sympatec GmbH |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–875 µm |
| Repeatability | <0.04% |
| Measurement Time | ≤10 s |
| Optical Theory | Fraunhofer and Mie |
| Maximum Obscuration | 50% |
| Disperser Volume | 400 mL |
| Ultrasonic Power | 60 W (adjustable) |
| Circulation Pump | Adjustable Peristaltic Pump |
| Optional Accessory | SVA Micro-Dispersion Unit (50 mL) |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HELOS & RODOS |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.1–3500 µm |
| Repeatability | ≤0.3% |
| Measurement Time | 10 s |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Product Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Principle | Laser Diffraction (Mie & Fraunhofer) |
| Measurement Range | 0.25–1750 µm |
| Repeatability | <0.3% RSD |
| Measurement Time | ≤10 s per run |
| Dispersion Method | Dry & Wet |
| Inlet Configuration | Forward-feeding sample port with custom-machined mounting fixtures |
| Throat Simulation | 90° glass elbow |
| DPI-specific Pre-Separator | For carrier-lactose/active pharmaceutical ingredient (API) separation |
| Flow Control | Venturi flowmeter (differential pressure-based, 0–200 L/min) |
| Fine Particle Collection | High-efficiency fine particle collector (up to 200 L/min) |
| Wash Bottle Module | Optional wet recovery unit (up to 60 L/min) |
| Vacuum Source | Regulated vacuum pump with needle valve for precise inspiratory flow simulation |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | QICPIC |
| Instrument Type | Dynamic |
| Measurement Range | 0.55–33,792 µm |
| Number of Lenses | 7 |
| Dispersion Method | Dry or Wet |
| Image Resolution | 4 Megapixels |
| Measured Parameters | Chord Length, Feret Diameter, Martin Diameter, Equivalent Spherical Diameter, Sphericity, Aspect Ratio |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.1–3500 µm |
| Repeatability | ≤0.04% RSD |
| Measurement Time | 10 s |
| Dispersion Method | Wet Dispersion |
| Housing Material | Stainless Steel |
| Optional Accessories | Heated Circulation Module (up to 100 °C), Temperature-Controlled Jacketed Flow Cell, Multiple Flow Cell Options (2 mm and 6 mm path lengths), Integrated Ultrasonic Dispersion (0–60 W, continuously adjustable) |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Product Type | Imported |
| Model | QICPIC & MIXCEL |
| Instrument Category | Dynamic Image-Based Particle Analyzer |
| Number of Lenses | 6 |
| Measurement Range | 1–3000 µm |
| Dispersion Method | Wet Dispersion |
| Camera Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter, Sphericity, Aspect Ratio, Convexity, Straightness, Elongation, Perimeter Equivalent Diameter (PED), LEFI, DIFI, VBFD |
Show next