| Brand | Aquaread |
|---|---|
| Country of Origin | United Kingdom |
| Model | LeveLine-EWS |
| Sensor Output | SDI-12 or Modbus RTU |
| Pressure Compensation | Integrated Barometric Sensor |
| Enclosure Dimensions | 90 × 90 × 160 mm |
| Water Level Accuracy | ±0.1% FS |
| Sensor Material | Stainless Steel Body with Polyoxymethylene (POM) Nose Cone |
| Warranty | 2 Years on LeveLine-Mini Sensor |
| Data Transmission | SMS and Email Alerts |
| Local Data Logging | Yes |
| Remote Configuration | SMS-based Command Interface |
| Third-Party Sensor Support | Up to 5 SDI-12 Devices |
| Brand | Argolight |
|---|---|
| Origin | France |
| Manufacturer | Argolight SAS |
| Model | Argo-HM Slide V2 |
| Substrate | AG03 ultra-pure fused silica core |
| Dimensions | 75 × 25 × 1.5 mm |
| Pattern Count | 16 embedded 3D fluorescent structures per slide |
| Excitation Range | 250–650 nm (continuous) |
| Emission Range | λₑₓ + 15 nm to 800 nm (continuous) |
| Photostability | Non-bleaching, lifetime-stable fluorescence |
| Damage Threshold | 50 GW/cm² (peak or average irradiance) |
| Immersion Compatibility | Dry, oil, water (no restrictions) |
| Objective Compatibility | All objectives ≤ 100× |
| Storage Conditions | 10–40 °C, 20–70 % RH |
| Imaging Modality Compatibility | Widefield, confocal, spinning disk, light-sheet, TIRF — excluding STED, RESOLFT, and multiphoton modalities |
| Traceability | Certified reference standard aligned with ISO/IEC 17025-accredited metrology labs (e.g., BAM) and ISO 21073:2019 |
| Brand | Argolight |
|---|---|
| Origin | France |
| Model | Argo-LM Slide V2 |
| Substrate | AG03 borosilicate glass core in anodized aluminum carrier |
| Dimensions | 75 × 25 × 1.5 mm |
| Excitation Range | 250–650 nm (continuous) |
| Emission Range | λₑₓ + 15 nm to 800 nm (continuous) |
| Immersion Compatibility | Dry, oil (unrestricted), water |
| Objective Compatibility | ≤20× magnification |
| Photostability | Non-bleaching, lifetime-stable fluorescence patterns |
| Laser Damage Threshold | 50 GW/cm² (peak or average irradiance) |
| Pattern Precision | <10 µm in all three dimensions |
| Compliance | Aligns with ISO 21073:2019 (“Fluorescence confocal microscopes for biological imaging — Optical data”) and supports GLP/GMP-aligned quality documentation workflows |
| Brand | ARGOLIGHT (distributed by Auniontech) |
|---|---|
| Origin | Shanghai, China |
| Product Type | Fluorescence Microscope Calibration Slide & Integrated Power Sensor |
| Dimensions | 75 × 25 × 6 mm |
| Excitation Wavelength Range | 250–650 nm (CW) |
| Emission Wavelength Range | λₑₓ + 15 nm to 800 nm (broadband) |
| Power Measurement Range | 10 µW – 100 mW |
| Measurable Wavelength Range | 350–1100 nm |
| Immersion Compatibility | Dry, oil, and water immersion objectives |
| Recommended Imaging Duration per Session | < 20 min |
| Storage Conditions | 10–40 °C, 20–70 % RH |
| Damage Threshold | 50 GW/cm² (peak or average irradiance) |
| Pattern Stability | Photostable, non-bleaching embedded 2D/3D fluorescent nanostructures |
| Brand | ARGOLIGHT (distributed by Auniontech) |
|---|---|
| Origin | Shanghai, China |
| Product Type | Calibration Slide & Resolution Target |
| Dimensions | 75 × 25 × 6 mm |
| Excitation Wavelength Range | 250–650 nm (CW) |
| Emission Wavelength Range | λₑₓ + 15 nm to 800 nm (broadband) |
| Immersion Compatibility | Dry, Oil, and Water Objectives |
| Recommended Imaging Duration per Session | <20 min |
| Storage Conditions | 10–40 °C, 20–70% RH |
| Damage Threshold | 50 GW/cm² (peak or average irradiance) |
| Optical Power Measurement Range | 10 µW – 100 mW |
| Spectral Coverage for Power Detection | 350–1100 nm |
| Brand | Argolight |
|---|---|
| Model | Argo-SIM Slide V2 |
| Substrate | AG03 Glass Core in Anodized Aluminum Housing |
| Dimensions | 75 × 25 × 1.5 mm |
| Fluorescence Stability | Lifetime (Non-photobleaching) |
| Excitation Range | 250–650 nm (Continuous) |
| Emission Range | λₑₓ + 15 nm to 800 nm (Continuous) |
| Immersion Compatibility | Dry, Oil (Unrestricted), Water |
| Objective Exposure Limit | <20 min per objective |
| Storage Conditions | 10–40 °C, 20–70 % RH |
| Laser Damage Threshold | 50 GW/cm² (Peak or Average Irradiance) |
| Pattern Count per Slide | 27 Distinct Fluorescent Microstructures |
| Imaging Compatibility | All Fluorescence-Based Modalities Except STED and Multiphoton |
| Software | Argolight Daybook (Proprietary Image Analysis & QC Database Platform) |
| Brand | Auniontech (Distributor) |
|---|---|
| Origin | Shanghai, China |
| Model | Argo-WP Calibration Microplate |
| Application | QC/QA of fluorescence imaging systems (HCS/HTS/HCI) |
| Excitation Range | 350–650 nm |
| Emission Range | ~365–800 nm |
| Substrate | Patented photostable glass with embedded 3D fluorescent patterns |
| Format | 4-well aluminum plate, each well containing one 75 mm × 25 mm × 1.5 mm Argolight glass slide |
| Pattern Stability | Non-bleaching, reusable, traceable to NMIs (e.g., BAM) |
| Compliance Support | IQ/OQ/PQ protocols, ASTM E3085, ISO 17025-aligned validation workflows |
| Software | Argolight Daybook v3.x (FDA 21 CFR Part 11-ready audit trail, open-format export, documented algorithms) |
| Key Features | Gold-coated integrating sphere |
|---|---|
| Power handling | 40 W (65 mm air-cooled), 4000 W (100 mm water-cooled), up to 12 kW (gold-coated sphere) |
| Power density tolerance | 5000 W/cm² |
| Wavelength range | 650 nm – 20 µm |
| Input port aperture | 10–200 mm |
| Standard fiber interface | SMA/FC |
| Configurable port count | 2 or 4 ports |
| Detector compatibility | Si, Ge, VIS-enhanced InGaAs, IR-extended InGaAs, standard InGaAs |
| Uniformity | <1% at 25 mm output port under side illumination |
| Cooling options | Convection-cooled (with ground-backplate for cold-plate mounting) or liquid-cooled |
| Brand | Artray |
|---|---|
| Origin | Japan |
| Model | ARTCAM-990SWIR-TEC |
| Spectral Range | 400–1700 nm |
| Sensor Type | InGaAs (Indium Gallium Arsenide) |
| Cooling | Thermoelectrically Cooled (TEC) |
| Category | SWIR Imaging Camera |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Model No. | 1-6393-01 |
| Measurement Range | 6.0 to 99,999.9 rpm |
| Resolution | 0.1 rpm |
| Accuracy | ±(0.01% of reading + 1 digit) |
| Sampling Interval | 1.0 to 10.0 seconds |
| Measurement Distance | 50–300 mm (with reflective tape) |
| Auto-ranging | Yes |
| Operating Temperature | 5–40 °C |
| Display | 6-digit LCD |
| Dimensions (W×H×D) | 58 × 28 × 122 mm |
| Weight | Approx. 140 g |
| Power Supply | Four AA batteries (included) |
| Accessories | Ten reflective tapes |
| Brand | AS ONE |
|---|---|
| Model | C6-4024-11 |
| Material | ABS Resin |
| Alarm Volume | ≥70 dB |
| Weight | ≈75 g |
| Power Supply | 1 × AAA battery (DC 1.5 V, included) |
| Dimensions | 82 × 23.2 × 76 mm |
| Max Timer Setting | 99 min 59 sec |
| Min Timer Setting | 1 sec |
| Repeat Function | Yes |
| Origin | China |
| Manufacturer | AS ONE Co., Ltd. |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | D2600 |
| Flow Control Accuracy | ±1% of reading (standard gas) |
| Standard Gas Flow Range | 0–10 sccm |
| Auxiliary Gas Flow Range | 0–4 SLPM |
| Dilution Gas Flow Range | 0–2000 sccm |
| Dilution Ratio Range | 1:10 to 1:2500 |
| Control Stability | <±0.1% FS |
| Repeatability | <0.2% |
| Operating Temperature | 0–45°C |
| Storage Temperature | −20–75°C |
| Dimensions | 150 × 120 × 170 mm |
| Weight | 1.5 kg |
| Power Supply | 24 VDC, 15 W |
| Battery | Integrated Li-ion |
| Communication | Ethernet ×1, RS232/RS485 |
| Display | 4.3″ touchscreen |
| Gas Interface | 1/8″ Swagelok |
| Wetted Materials | 316 stainless steel, FEP, FKM, Viton |
| Relative Humidity | 5–95% RH (non-condensing) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-5000α |
| Measurement Principle | Abbe-type refractometry with automatic temperature control (Peltier) |
| Refractive Index Range | 1.32000–1.70000 nD |
| Brix Range | 0.0–100.0% |
| Refractive Index Accuracy | ±0.00004 nD |
| Brix Accuracy | ±0.03% |
| Temperature Control Range | 5–75°C |
| Temperature Accuracy | ±0.05°C |
| Compliance | FDA 21 CFR Part 11 (electronic records & signatures), ISO/IEC 17025 traceable operation, GLP/GMP-ready data audit trail |
| Brand | ATP Optosky |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ATM5100 |
| Price | Upon Request |
| Sampling Rate | 2 MHz |
| Spectral Range | 800–1650 nm |
| Photosensitive Area | Ø3 mm (customizable) |
| Max. Measurable Power | +3 dBm |
| Min. Measurable Power | −70 dBm |
| Nonlinearity | <0.5% |
| Measurement Uncertainty | ±2% |
| Calibration | Built-in traceable calibration |
| Output Interface | USB 2.0 High-Speed |
| Optical Input | FC/PC connector and free-space coupling |
| Optional Accessory | OD3 calibrated neutral-density attenuator |
| Brand | Auniontech |
|---|---|
| Origin | Imported |
| Model | 1 pT |
| Sensitivity | 1 pT/√Hz |
| Measurement Range | 20–100 µT |
| Typical Drift | <0.3 nT |
| Sampling Rate | 1000 Hz |
| Closed-Loop Bandwidth | 30 Hz |
| Sensor Angular Acceptance | ±45° |
| Operating Temperature | −20 °C to +40 °C |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Type | Passive Vibration Isolation Platform |
| Operating Principle | Damped Rubber/Composite Spring + Inertial Mass Block |
| Natural Frequency | 3–8 Hz (optimized for 5–100 Hz environmental disturbances) |
| Isolation Efficiency | >90% @ ≥10 Hz |
| Load Capacity | 20–150 kg (model-dependent) |
| Standard Tabletop Dimensions (W × D) | 450×450 mm, 600×600 mm, 750×750 mm |
| Tabletop Material | Low-carbon steel or stainless steel (optional magnetic surface) |
| Leveling Method | Manual adjustable leveling feet |
| Environmental Suitability | Indoor laboratory, cleanroom, and office environments |
| Compliance | Designed per ISO 20483 (Vibration isolation — Passive isolators — Performance characterization) and compatible with GLP-aligned lab infrastructure |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Argolight Argo-POWER-HM Calibration Slide & Resolution Target |
| Optical Pattern Dimensions | 75 × 25 × 6 mm (Standard Microscope Slide Format) |
| Excitation Wavelength Range | 250–650 nm (CW) |
| Emission Wavelength Range | λₑₓ + 15 nm to 800 nm (Broadband) |
| Immersion Compatibility | Dry, Oil, and Water Objectives |
| Max Exposure Duration per Session | <20 min |
| Storage Conditions | 10–40 °C, 20–70% RH |
| Imaging Compatibility | All fluorescence-based modalities except STED and multiphoton microscopy |
| Damage Threshold | 50 GW/cm² (peak or average irradiance) |
| Power Measurement Range | 10 µW – 100 mW |
| Supported Wavelengths for Power Sensing | 350–1100 nm |
| Time-Lapse Compatible | Yes |
| Warranty | Lifetime (limited, non-transferable) |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | AU-TIM-100 |
| Time Interval Stability | ≤3 ps/s |
| Uncertainty | ≤20 ps |
| Peak-to-Peak Jitter | ≤25 ps |
| Resolution | <1 ps |
| Measurement Range | 0–1 s |
| Nonlinearity | <25 ps (at 10 MHz offset of 0.01 Hz) |
| Input Interfaces | SMA-F (10 MHz Ref In/Out, LVTTL PPS IN1/IN2) |
| Output Interfaces | DB9 RS-232, RJ45 Ethernet |
| Control Interface | USB 2.0 |
| Dimensions | 145 × 347 × 300 mm |
| Power Supply | 220 VAC |
| Brand | Auniontech |
|---|---|
| Model | AU-TIM-HP |
| Measurement Principle | Time-of-Flight & Phase-Interpolated Timestamping |
| Time Interval Stability | ≤3 ps/s |
| Time Interval Uncertainty | ≤20 ps |
| Peak-to-Peak Jitter (Baseline) | ≤25 ps |
| Nonlinearity | <0.01 Hz frequency offset at 10 MHz, peak-to-peak error ≤25 ps |
| Measurement Range | 0–1 s |
| Resolution | <1 ps (sub-picosecond interpolation) |
| Input Interfaces | SMA-F (10 MHz Ref In/Out, PPS IN1/IN2, LVTTL 3.3 V, rise time <5 ns) |
| Output/Control Interfaces | DB9 RS-232, RJ45 Ethernet, USB 2.0 host port |
| Dimensions | 145 × 347 × 300 mm |
| Power Supply | 220 VAC |
| Compliance | CE-marked, RoHS-compliant, designed for GLP-aligned metrology workflows |
| Brand | Auniontech |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | AUM-LSV1310 |
| Optical Wavelength | 1310 nm |
| Laser Safety Class | Class I (IEC 60825-1) |
| Output Power | <5 mW |
| Frequency Range | DC to 2.5 MHz |
| Displacement Noise Density | 5 pm/√Hz |
| Displacement Resolution | 1.28 nm |
| Maximum Velocity Range | 4.5 m/s |
| Velocity Resolution | <1 µm/s (at 1 kHz) |
| Displacement Repeatability (>10 Hz) | ±1 nm |
| Displacement Repeatability (<10 Hz) | ±10 nm |
| Vibration Frequency Accuracy | ±0.02% |
| Dynamic Velocity Range | 20 m/s (peak) |
| Sampling Rate | 5 MS/s (real-time digital acquisition) |
| Signal Output | Ethernet (TCP/IP, UDP), Digital TTL sync |
| Power Supply | 12–24 V DC |
| Power Consumption | <4 W |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 35–85% RH (non-condensing) |
| Housing Material | Anodized Aluminum Alloy |
| Dimensions | 83.7 × 50 × 22 mm |
| Weight | 180 g |
| Brand | Auniontech |
|---|---|
| Model | AUT-F100 |
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 420–690 (FOB) |
| Measurement Principle | Rayleigh/Brillouin-based Distributed Acoustic Sensing (DAS) and Distributed Temperature Sensing (DTS) |
| Operating Temperature | –40 °C to +150 °C |
| Pressure Rating | Up to 10,000 psi |
| Sensing Length | Up to 50 km per fiber channel |
| Spatial Resolution | 1 m (DTS), 10 m (DAS) |
| Sampling Rate | Up to 10 kHz (DAS), 1 Hz (DTS) |
| Brand | Auniontech |
|---|---|
| Model | Aut-S200 |
| Measurement Principle | Optical Fabry–Pérot Interferometry |
| Pressure Range | 0–3000 mmHg |
| Accuracy | ±1% FS |
| Resolution | 0.01% FS |
| Operating Temperature | 0–200 °C |
| Overload Capacity | 300% FS |
| Sensor Diameter | ≤260 µm |
| PI Tube Outer Diameter | 330 ± 0.03 µm |
| Fiber Connector | FC/APC |
| Packaging Options | Bare Die or PI Tubing Encapsulation |
| Electromagnetic Immunity | Immune (Fiber-Optic Sensing) |
| Intrinsic Safety | Certified for Use in Explosive or High-EMI Environments |
| Brand | Auniontech |
|---|---|
| Model | Aut-S300 |
| Operating Temperature Range | -40 to 300 °C |
| Accuracy | ±0.5 °C |
| Resolution | 0.1 °C |
| Sensitivity | 10 pm/°C |
| Center Wavelength | 1528–1568 nm (±0.1 nm) |
| Full Width at Half Maximum (FWHM) | <0.3 nm |
| Side Mode Suppression Ratio (SMSR) | >12 dB |
| Peak Reflectivity | >70% |
| Fitting Method | Polynomial Calibration |
| Connector Type | FC/APC |
| Packaging | Ceramic/Metal Hermetic Encapsulation |
| Immunity | EMI/RFI Immune |
| Compliance | Designed for IEC 61757-1, ISO/IEC 17025 traceable calibration protocols |
| Brand | Auniontech |
|---|---|
| Model | Aut-S500 |
| Operating Temperature Range | -40 to 1000 °C |
| Accuracy | ±0.1 °C (when used with compatible interrogator) |
| Resolution | 0.02 °C |
| Wavelength Range | 1528–1568 nm (±0.1 nm center wavelength tolerance) |
| Thermal Sensitivity | 30–50 pm/°C |
| FWHM | <0.3 nm |
| Side Mode Suppression Ratio (SMSR) | >12 dB |
| Peak Reflectivity | >70% |
| Dimensions | 35 mm × 10 mm × 5.5 mm |
| Connector Type | FC/APC |
| Packaging | Ceramic Hermetic Encapsulation |
| Brand | Auniontech |
|---|---|
| Model | Aut-S600 |
| Center Wavelength | 1528–1568 nm (±0.1 nm) |
| Strain Range | ±1500 / ±3000 / ±5000 με |
| Accuracy | ±2 με |
| Resolution | 0.1 με |
| Strain Sensitivity | 1.2 pm/με |
| Temperature Sensitivity | Calibrated |
| Operating Temperature | −40 to +300 °C |
| Weight | <25 g |
| FWHM | <0.3 nm |
| Side Mode Suppression Ratio | >12 dB |
| Peak Reflectivity | >70% |
| Connector | FC/APC |
| Packaging | Metallic or Flexible Substrate |
| Bonding | Adhesive-free Encapsulation |
| Brand | Auniontech |
|---|---|
| Model | Aut-S700 |
| Sensing Principle | Fiber Bragg Grating (FBG) Interrogation |
| Measurement Range | 0–2 g / 0–50 g / 0–200 g (selectable) |
| Accuracy | ±5% FS |
| Bandwidth | 1 dB flat response up to 600 Hz or 1000 Hz (configurable) |
| Resolution | 0.1% FS |
| Sensitivity | 8–400 pm/g |
| Operating Temperature | −40 °C to +250 °C |
| Package Options | Ceramic or metal hermetic housing |
| Dimensions | 40×20×3 mm / 35×25×30 mm / 33×18×3 mm / 40×20×14 mm (model-dependent) |
| Fiber Connector | FC/APC |
| Cable Protection | PTFE-coated armored fiber |
| Electromagnetic Immunity | Immune to EMI/RFI, lightning-resistant, corrosion-resistant |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | Cono60°XR |
| Acceptance Angle | ±60° |
| Angular Resolution | 0.1° |
| Distortion | <2% |
| Chief Ray Angle (CRA) Control | <3° |
| Relative Illumination | Uniform, No Vignetting |
| Sample Size Compatibility | Point Sources <1.5 mm, External Displays >4.3 mm |
| Object Distance | Infinity |
| Working Distance | 5 mm |
| Image Circle Diameter | 8.6 mm |
| Peak Wavelength | 540 nm |
| Spectral Range | 405–780 nm |
| Interface | C-Mount |
| Recommended Sensor | Sony IMX183 (2.3 MP) |
| Length × Outer Diameter | 225 mm × 65 mm |
| Weight | 850 g (lens only) |
| Brand | Auniontech |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eta100 L Ultra |
| Price Range | USD 14,000 – 70,000 |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Julight Differential Laser Vibrometer for Engine Valve Dynamics |
| Pricing | Available Upon Request |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Julight Micro-VibroScope Series |
| Price | Upon Request |
| Measurement Principle | Non-contact Laser Doppler Vibrometry (LDV) with Integrated High-Resolution Optical Microscopy |
| Frequency Range | Up to 35 MHz |
| Displacement Resolution | 10 pm |
| Spot Size | < 4 µm |
| Maximum Velocity | ±40 m/s (at 3 MHz bandwidth) |
| Velocity Accuracy | ±1% of reading |
| Measurement Direction | Normal-component vibration only |
| Configuration Options | Single-point, 2D scanning, and 3D scanning modes available |
| Compliance | Designed for ISO 18431-1 (Vibration and shock — Signal processing), ASTM E1876 (Standard Test Method for Dynamic Young’s Modulus), and compatible with GLP/GMP-aligned data integrity workflows |