| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR300 |
| Operating Temperature | -40 to +70 °C (standard, non-condensing) |
| Analog Inputs | 6 single-ended or 3 differential (software-configurable) |
| ADC Resolution | 24-bit |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40 °C |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Outputs | 2 (VX1, VX2) |
| Digital I/O | 7 configurable terminals (C1, C2, P_SW, SE1–SE4 |
| Communication Interfaces | USB Micro-B, RS-232, Ethernet (10/100BASE-T), PPP, RNDIS |
| Supported Protocols | PakBus, Modbus RTU/TCP, DNP3, SDI-12, TCP/IP, UDP, TLS v1.2, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, NTP, DHCP, DNS, ICMP, IPv4/IPv6 |
| Real-Time Clock Accuracy | ±1 minute per month (battery-backed) |
| Power Supply | 16–32 Vdc (CHG input) |
| Idle Current Draw | 1.5 mA @ 12 Vdc |
| Active Current Draw | 5 mA @ 12 Vdc (1 Hz scan, 1 analog measurement) |
| Enclosure Material | Powder-coated aluminum |
| Dimensions | 13.97 × 7.62 × 4.56 cm (5.5 × 3.0 × 1.8 in.) |
| Weight | 242–250 g (0.53–0.55 lb) |
| Onboard Memory | 80 MB flash (program/storage), 30 MB dedicated data storage |
| Programming Language | CRBasic (onboard BASIC-like language) |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR3000 |
| Analog Input Channels | 28 single-ended (14 differential) |
| Analog Voltage Range | ±5000 mV |
| Analog Resolution | 0.33 µV |
| A/D Resolution | 16-bit |
| Maximum Scan Rate | 100 Hz |
| Pulse Count Channels | 4 |
| Switched Excitation Outputs | 4 voltage, 3 current |
| Control Ports | 3 SDM, 8 I/O |
| Communication Interfaces | CS I/O, RS-232, Ethernet (optional), RF radio (optional), CDMA/GPRS (optional), satellite (optional) |
| Supported Protocols | PakBus, Modbus RTU/ASCII/TCP, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTP, NTCIP, SDI-12, SDM |
| Memory | 4 MB internal |
| Power Consumption | 2 mA (sleep), 3 mA (1 Hz), 10 mA (100 Hz) |
| Environmental Compliance | CE, EMC, GDT input protection |
| Real-Time Clock | Temperature-compensated, battery-backed |
| Data Storage Format | Tabular (timestamp + record number) |
| Operating Temperature | 0–40 °C |
| Software Compatibility | LoggerNet 3.4/4.0, PC400 1.2, ShortCut 2.2 |
| Brand | CAMPBELL |
|---|---|
| Origin | USA |
| Model | CR310 |
| Operating Temperature | -40 to +70°C (standard, non-condensing) |
| Scan Rate | Up to 10 Hz |
| Analog Inputs | 6 single-ended or 3 differential (user-configurable) |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Outputs | 2 (VX1, VX2) |
| Communication Interfaces | USB Micro-B, RS-232, 10/100 Base-T Ethernet (RJ45) |
| Digital I/O | 7 configurable terminals (C1, C2, P_SW, SE1–SE4 |
| ADC Resolution | 24-bit |
| Analog Accuracy | ±(0.04% of reading + offset) at 0–40°C |
| Power Input | 16–32 Vdc (CHG), 10–18 Vdc (BAT) |
| Typical Idle Current | 10 mA @ 12 Vdc (Ethernet link idle) |
| Active Current | 56 mA @ 12 Vdc (Ethernet active, CPU always on) |
| Enclosure | Powder-coated aluminum |
| Dimensions | 16.26 × 7.62 × 5.68 cm (6.4 × 3.0 × 2.2 in.) |
| Weight | 288–306 g (0.64–0.68 lb) |
| Onboard Memory | 80 MB flash for OS/program, 30 MB for data storage |
| Protocols | PakBus, Modbus RTU/TCP, DNP3, SDI-12, TCP/IP, UDP, TLS 1.2, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, NTP, DHCP, SLAAC, ICMP, Telnet, PPP, RNDIS, Auto-IP |
| Real-Time Clock Accuracy | ±1 minute per month |
| Brand | CAMPBELL |
|---|---|
| Origin | USA |
| Model | CR350 |
| Operating Temperature | -40 to +70 °C (standard, non-condensing) |
| Max Scan Rate | 10 Hz |
| Enclosure Material | High-impact polycarbonate (Recycling Code 7) |
| Analog Inputs | 4 single-ended or 2 differential (software-configurable) |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Terminals | 2 (VX1, VX2) |
| Communication Interfaces | USB Type-C 2.0, RS-232, RS-485 |
| 12 V Switched Power Outputs | 2 |
| Digital I/O | 7 (C1, C2, P_SW, SE1–SE4 |
| Input Range | -100 to +2500 mV |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40 °C |
| ADC Resolution | 24-bit |
| Power Supply Input (CHG) | 16–32 Vdc (max 1.1 A for charger/solar input) |
| Real-Time Clock Accuracy | ±1 min/month |
| Supported IP Protocols | Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS v1.2, DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, MQTT(S) |
| Communication Protocols | PakBus, PakBus Encryption, Modbus RTU/ASCII/TCP, DNP3, SDI-12 |
| CPU & Program Memory | 50 MB serial flash |
| Data Storage | 50 MB serial flash |
| Idle Current Draw | 0.5 mA (@ 12 Vdc) |
| Active Current Draw | 8 mA (@ 12 Vdc, processor always on) |
| Dimensions | 16.3 × 8.4 × 5.6 cm (6.4 × 3.3 × 2.2 in.) |
| Weight | 288–306 g (0.64–0.68 lb), depending on comms options |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR6 |
| Processor | 32-bit ARM Cortex-M4 with hardware floating-point unit (100 MHz) |
| Internal Memory | 4 MB RAM, 6 MB flash for OS, 1 MB serial flash for program execution |
| MicroSD Card Support | Up to 16 GB |
| Real-Time Clock Accuracy | ±3 minutes/year (±10 µs with GPS synchronization) |
| USB Interface | USB 2.0 Full-Speed (12 Mbps), host/device capable |
| Ethernet | 10/100BASE-T |
| Communication Protocols | PakBus, SDI-12, SDM, RS-232, RS-485, CPI (Campbell Peripheral Interface) |
| U-Port Capabilities | Simultaneous analog/digital input, static vibration measurement (100 Hz – 6.5 kHz), bridge excitation (±2.5 V or ±2.5 mA), thermistor support (5 kΩ reference), frequency measurement up to 200 kHz |
| Analog Input | 12 single-ended or 6 differential channels |
| ranges | ±5000 mV, ±1000 mV, ±200 mV |
| Analog Output | 12-bit DAC (±2.5 V or ±2.5 mA) |
| Digital I/O | 12 configurable ports (3.3 V / 5 V logic) |
| Power Input | 12 V DC battery, solar (16–32 V DC), or USB |
| SW12V outputs | 2 × 12 V @ 1100 mA (20 °C) |
| Overvoltage Protection | All terminal strips include transient voltage suppression |
| Operating Temperature | −25 °C to +50 °C (extended range options available) |
| Dimensions | 20.3 × 10.2 × 6.1 cm |
| Weight | 0.42 kg |
| Compliance | CE, FCC Part 15 Class B, RoHS |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR6 |
| Operating Temperature Range | -40 to +70°C (standard), -55 to +85°C (extended) |
| Analog Input Resolution | 24-bit ADC |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40°C |
| Input Channels | Up to 12 single-ended or 6 differential analog inputs |
| Communication Interfaces | Ethernet (10/100 RJ-45), USB Micro-B (virtual Ethernet & serial), RS-485, RS-422, SDI-12, CPI, CS I/O |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Power Supply | 10–18 Vdc (BAT), 16–32 Vdc (CHG) |
| Real-Time Clock Accuracy | ±3 min/year (GPS optional: ±10 µs) |
| Vibration Compensation | VSECT® spectral analysis for static vibrating-wire measurements |
| Enclosure | UV-stabilized TPE over impact-resistant polycarbonate (Recycling Code 7) |
| Dimensions | 21.0 × 10.2 × 5.6 cm |
| Weight | 0.42–0.52 kg |
| Brand | Campbell Scientific |
|---|---|
| Model | CR800 |
| Origin | USA |
| Differential Input Channels | 3 (6 single-ended) |
| Analog Input Resolution | 13-bit A/D |
| Scan Rate | Up to 100 Hz |
| Operating Temperature Range | 0 to 40 °C |
| Voltage Measurement Resolution | 0.33 µV |
| Sleep Mode Current Draw | ~0.6 mA |
| Active Current Draw (w/o RS-232) | 1–16 mA |
| Active Current Draw (w/ RS-232) | 17–28 mA |
| Communication Interfaces | 1 × CS I/O port, 1 × RS-232 serial port |
| Supported Protocols | PakBus®, Modbus RTU/ASCII, SDI-12, SDM, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP |
| Onboard Memory | 4 MB (data + program storage) |
| Data Format | Tabular ASCII |
| Operating System | PakBus OS |
| Compatible Software | LoggerNet, PC400, Short Cut |
| Optional Peripheral | CR1000KD handheld display |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cavitation Monitoring System |
| Price | Upon Request |
| Pressure Range | 0–100 bar |
| Pressure Hose Length | 3 ft |
| Gas Supply Hose Length | 6 ft |
| Minimum Sample Length | 4.25 in |
| Brand | Zhongjiao Jinyuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | CEL-GPPCH Custom Hydrogenation Reaction System |
| Pricing | Upon Request |
| Dimensions | 1410 mm × 730 mm × 1664 mm |
| Construction Material | ASTM A240 316L Stainless Steel |
| Reactor Temperature Range | 0–300 °C (precision oil-bath heating) |
| Vaporizer Temperature Range | 0–600 °C |
| Tubing Trace Heating Range | 0–200 °C |
| Maximum Operating Pressure | <10 MPa |
| Liquid Flow Rate | 0.1–5 mL/min |
| Catalyst Bed Volume | <100 mL |
| Gas Flow Range (expandable channels) | 0–500 sccm per line |
| Analytical Balance Capacity | 0–15 kg (resolution: 0.1 g) |
| Safety Systems | Proportional pressure relief valve, rupture disc, independent overtemperature alarm at all thermal zones, interlocked shutdown logic |
| Brand | CEL-Jiaoguang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CEL-RCCN (monocrystalline) / CEL-RCCO (polycrystalline) |
| Calibration Traceability | NIM-traceable (National Institute of Metrology, China) |
| Certified Spectral Response Range | 400–1100 nm |
| Active Area | 20 mm × 20 mm |
| Mounting Base | Anodized Aluminum (70 mm × 70 mm × 20 mm) |
| Cover Window | Space-grade radiation-hardened glass with refractive-index-matched optical adhesive |
| Temperature Sensor | Calibrated Pt100 RTD (4-wire Kelvin connection) |
| Electrical Interface | Dual LEMO connectors (Isc/Voc + temperature) |
| STC Conditions | 1000 W/m², AM1.5G spectrum, 25 °C cell temperature |
| CV Value Uncertainty | ≤ ±0.5 % (k=2) |
| Short-Circuit Current Stability | ≤ ±0.5 % over 1,000 h under continuous illumination |
| Operating Temperature Range | 10–40 °C |
| Max Continuous Current | 200 mA |
| Efficiency (STC) | >16 % |
| Fill Factor (FF) | >0.70 |
| Isc Temp Coefficient α | typical −0.05 to −0.08 mA/°C |
| Voc Temp Coefficient β | typical −1.8 to −2.2 mV/°C |
| Brand | CEL (Zhongjiao Jin Yuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | CEL-NP2000-2 |
| Measurement Range | 0–2,000 mW/cm² |
| Spectral Range | 190 nm – 2.5 µm (uniform response), extendable to 11,000 nm with calibration correction |
| Resolution | 1 µW |
| Response Time | < 0.4 s |
| Thermal Drift | < ±1% FS over 10 min |
| Accuracy | ±5% |
| Detector Active Area | Ø10 mm (0.75 cm²) |
| Max Power Density Tolerance | 200 W/cm² |
| Auto-ranging | 4 ranges (2 mW / 20 mW / 200 mW / 2000 mW) |
| Output | Digital LCD + Analog (1–1999 mV) |
| Power Supply | Rechargeable Li-ion battery + AC adapter (220 V, 50 Hz) |
| Brand | CEL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEL-NP2000-10 |
| Price | Upon Request |
| Wavelength Range | 190 nm – 11,000 nm |
| Power Density Range | 0–2,000 mW/cm² / 0–10,000 mW/cm² (auto-ranging) |
| Sensor Active Area | Ø20 mm (314 mm²) |
| Spectral Response | 0.19–2.5 µm (uniformity ±2.7%) |
| Max Continuous Irradiance | 200 W/cm² |
| Resolution | 1 µW |
| Response Time | <0.4 s |
| Thermal Drift | <±1% FS within 10 min |
| Uncertainty | ±5% |
| Analog Output | 1–1999 mV |
| Operating Environment | Standard optical lab, 25°C, ambient pressure, no direct airflow |
| Power Supply | Rechargeable Li-ion battery + 220 V / 50 Hz charger |
| Brand | CEL (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model Variants | CEL-NP2000-2A (2 W Full Scale), CEL-NP2000-10A (10 W Full Scale) |
| Power Range | 0–2000 mW / 0–10000 mW |
| Detector Aperture | Ø10 mm / Ø20 mm |
| Spectral Range | 190 nm – 11,000 nm (UV-VIS-IR) |
| Temperature Compensation | 15–45 °C, Drift < ±1% FS |
| Resolution | 1 µW |
| Response Time | < 0.4 s |
| Accuracy | ±5% FS |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Built-in TF card logging |
| Power Supply | Internal 3000 mAh Li-ion battery (AC adapter: 220 V, 50 Hz) |
| Output Units | mW, mW/cm² |
| Brand | CEAJIN (Zhongjiaojinyuan) |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CEL-NPRC |
| Price | Upon Request |
| Brand | CEL (Zhongjiao Jinyuan) |
|---|---|
| Model | CEL-RCCN (monocrystalline), CEL-RCCO (polycrystalline) |
| Active Area | 20 mm × 20 mm |
| Spectral Response Range | 400–1100 nm |
| Calibration Irradiance | 1000 W/m² (AM1.5G) |
| Calibration Temperature | 25 °C ± 0.1 °C |
| Temperature Sensor | Calibrated Pt100 RTD (4-wire Kelvin connection) |
| Window Material | Space-grade radiation-hardened glass with refractive-index-matched optical adhesive |
| Enclosure Dimensions | 70 mm × 70 mm × 20 mm (aluminum baseplate) |
| CV Value Unit | A/(W·m⁻²) |
| Short-Circuit Current Temperature Coefficient α | typical –0.05 to –0.07 mA/°C |
| Open-Circuit Voltage Temperature Coefficient β | typical –2.0 to –2.5 mV/°C |
| Max Operating Current | 200 mA |
| Operating Temperature Range | 10–40 °C |
| Stability | Short-circuit current drift ≤ ±0.5% over 1,000 h under continuous illumination |
| Efficiency (STC) | ≥16% (monocrystalline), ≥15.2% (polycrystalline) |
| Fill Factor (FF) | ≥0.70 |
| Traceability | NIST-traceable calibration per ISO/IEC 17025-accredited laboratory |
| Certification | Individual test report with expanded uncertainty (k=2), full metrological traceability statement, and compliance documentation for IEC 60904-2, IEC 60904-3, and ASTM E1021 |
| Brand | Cellix |
|---|---|
| Origin | Ireland |
| Model | FS-1.5 / FS-7.0 / FS-80.0 / FS-1000 |
| Flow Ranges | ±1.5 µL/min |
| Accuracy | ±0.5% FS (FS-1.5) to ±0.2% FS (FS-1000), or ±5–10% of reading |
| Dead Volume | 1.0 µL |
| Max Operating Pressure | 200 bar |
| Dimensions | 60 × 51 × 21 mm |
| Weight | <0.1 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 13100 |
| Internal Sensor Range | 0 °C to +50 °C (32 °F to 122 °F) |
| External Sensor Range | −50 °C to +70 °C (−58 °F to 158 °F) |
| Accuracy | ±1 °C (±2 °F) |
| Resolution | 0.1 °C |
| Response Time (T₉₀) | 10 s |
| Memory Function | Min/Max Recording |
| Alarm | High/Low Temperature Threshold Alert |
| Calibration Points | −20 °C, +4 °C, +37 °C |
| Filling Fluid | Ethylene Glycol-Based Mixture |
| Accessories | 30 mL Plastic Storage Vial |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 15210 |
| Thermocouple Types Supported | K, J, E, T, N, R, S |
| Temperature Range | −200 °C to +1370 °C (Type K) / −328 °F to +2498 °F (Type K) |
| Accuracy | ±0.1 % of reading + 0.7 °C (±1.3 °F) |
| Resolution | 0.1 °C / 0.1 °F below 600 °C |
| Memory Capacity | 32,000 data points per channel |
| Dimensions | 187 × 75 × 29 mm |
| Housing | Black plastic |
| Communication | Bluetooth 4.0 + USB 2.0 |
| Display | Backlit LCD showing all four channels simultaneously |
| Power | Internal rechargeable battery with battery-level indicator |
| Features | Unit toggle (°C/°F), Z-value memory, averaging function, data lock, auto-backlight |
| Brand | Chengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZDZ-1J |
| Measurement Principle | Thermal Conductivity (Pirani) |
| Pressure Range | 1.0 × 10⁵ Pa to 1.0 × 10⁻¹ Pa (Atmosphere to 0.1 Pa) |
| Vacuum Port | KF16 |
| Display | TFT Touchscreen Interface |
| Processor | ARM Cortex-M3 |
| Accuracy | ±20% of reading |
| Standard Gauge Tube | CY-1Z Pirani Sensor (KF16 flange) |
| Cable Length | 3 m |
| Dimensions (H×W×D) | 103 × 120 × 155 mm |
| Weight | ~2.0 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Optional Outputs | 0–10 V analog output |
| Brand | Chotest |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PO40 |
| Price | USD 1,700 (approx.) |
| Brand | Chotest |
|---|---|
| Model | PO40 |
| Origin | Guangdong, China |
| Type | In-machine contact touch probe |
| Transmission | Modulated infrared |
| Repeatability (2σ) | <1.0 µm |
| Trigger life | >10 million cycles |
| Battery life | ≥150 hours (5% duty cycle) |
| Operating range | XY plane ±360°, Z-axis ±85°, linear transmission distance up to 5 m (standard power mode) |
| Protection rating | IP68 (probe & receiver), IPX8 (probe body sealing) |
| Power source | Replaceable primary battery |
| Control interface | M-code compatible, auto-wake via receiver, programmable delay-off |
| Diagnostic feedback | Multi-state LED indicators (wake/sleep, ready/triggered, battery status) |
| Software integration | Compatible with Chotest in-machine measurement software for automated program generation, 3D coordinate acquisition, and GD&T-compliant reporting |
| Brand | Cinogy |
|---|---|
| Origin | Germany |
| Model | CinCam CMOS |
| Sensor | 1288 × 1032 pixel high-sensitivity CMOS |
| Dynamic Range | 2500:1 |
| Interface | USB 2.0 |
| Power | USB bus-powered |
| Dimensions | 36 mm × 36 mm × 24 mm |
| Weight | 45 g |
| Mount | Standard C-Mount |
| Software Options | RayCi-Standard (full-featured) / RayCi-Lite (essential analysis) |
| UV Converter Support | 100–320 nm |
| IR Converter Support | 1495–1595 nm |
| Brand | Coherent |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WaveMaster |
| Price | USD 14,500 (approx.) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ATRS-1000 |
| Detection Principles | CO₂ – Dual-Beam NDIR |
| Measured Gases | CO₂ (0–10,000 ppm), CO (1–1,000 ppm) |
| Pressure Range | 40–180 kPa |
| Temperature Range | −40 °C to +125 °C |
| Resolution | 1 ppm |
| CO₂ Accuracy | ±(50 ppm + 3% of reading) |
| CO Accuracy | ±40 ppm or ±30% of reading (whichever is greater) |
| Pressure Accuracy | ±1 kPa |
| Temperature Accuracy | ±2 °C |
| T₉₀ Response Time | <25 s |
| Data Refresh Rate | ≤1 s |
| Output Interfaces | CAN, LIN, UART, Analog Voltage |
| Operating Temp/Humidity | −40 °C to +85 °C / 0–99% RH (non-condensing) |
| Storage Conditions | −40 °C to +110 °C / 0–99% RH (non-condensing) |
| Supply Voltage | 9–16 VDC (nominal 12 VDC) |
| Avg. Current Draw | ≤100 mA @ 12 VDC |
| Sleep Current | <100 µA |
| IP Rating | IP65 |
| Particle Measurement | Optical Scattering (0–5 mg/m³, ±10% accuracy, response <8 s) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | CM2200 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| ETCO₂ Range | 0–150 mmHg (0–20 kPa at 760 mmHg) |
| ETCO₂ Resolution | 0.1 mmHg (0–49 mmHg), 0.2 mmHg (50–150 mmHg) |
| ETCO₂ Accuracy | ±2 mmHg (0–40 mmHg), ±5% of reading (41–70 mmHg), ±8% of reading (71–100 mmHg), ±10% of reading (100–150 mmHg) |
| Respiratory Rate Range | 2–150 breaths/min |
| Respiratory Rate Accuracy | ±1 breath/min |
| Communication Interface | TTL / RS-232 |
| Operating Conditions | 0°C–45°C, 10–90% RH (non-condensing) |
| Storage Conditions | −40°C–70°C, <90% RH (non-condensing) |
| Dimensions | 52 × 23 × 36 mm (W×H×D) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BF-2000 |
| Price | Upon Request |
| Flow Range (G2.5) | 0.08–4 Nm³/h |
| CH₄ Concentration Range | 30–100 % |
| Accuracy Class | 1.5 |
| Transitional Flow (Qₜ) | 0.4 Nm³/h |
| Overload Flow | 4.8 Nm³/h |
| Max. Operating Pressure | 20 kPa |
| Connection Thread | M30×2.0 |
| Operating Temperature | −10 to +40 °C |
| Storage Temperature | −20 to +50 °C |
| Explosion Protection Rating | Ex ib IIB T3 Gb |
| Power Supply | 3 × AA alkaline batteries (1-year typical life) |
| Display | LCD |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NOx/O₂ Dual-Gas Sensor |
| Voltage Range | 16–36 V DC |
| O₂ Measurement Range | 0–21% vol |
| NOx Measurement Range | 0–1500 ppm (NO + NO₂, λ > 1, NH₃-free environment) |
| NOx Accuracy | ±10 ppm (for [NOx] < 100 ppm) |
| Response Time (T₃₃–₆₆%) | NOx: 1200 ms (new generation), 1300 ms (legacy) |
| O₂ | 1000 ms (new), 1100 ms (legacy) |
| Fast Transient Response (T₁₀–₉₀%) | NOx: 100 ms |
| O₂ | 80 ms |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturing Type | OEM Sensor Component |
| Product Type | NOx Sensing Chip (HTCC-Based Electrochemical Platform) |
| Model | NOx Sensor Chip |
| Operating Principle | Potentiometric/Electrochemical Current Measurement |
| Measurement Range | 0–3076 ppm NOx |
| Operating Temperature | −40 °C to 1000 °C (exhaust-side) |
| Ambient Temperature Rating | −40 °C to 105 °C |
| Supply Voltage | 12 V / 24 V DC |
| CAN Interface | ISO 11898-2 compliant, 250 kbps baud rate |
| CAN Message Interval | 50 ms |
| Heater Power Consumption | Low-power integrated HTCC heater |
| Structural Design | Compact, high-vibration-resistant dual protective cap |
| Lifetime | Extended operational lifespan under cyclic thermal stress |
| Compliance | Designed for alignment with Euro VI, China VI, and EPA Tier 4 emission regulation monitoring requirements |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Oxygen Sensor Chip |
| Measurement Range | 0.98–1.02 (λ unit) |
| Operating Temperature | −40 °C to 1000 °C |
| Ambient Temperature Range | −40 °C to 105 °C |
| Supply Voltage | 12 V DC |
| Startup Time | ≤15 s to operational temperature (vs. >30 s for conventional thimble-type) |
| Heater Power Consumption | <12 W (typical at cold start) |
| Sensor Architecture | Multilayer ceramic planar element with integrated micro-heater and dual protective guard tubes |
| Aging Resistance | <±0.005 λ drift after 100,000 km simulated exhaust exposure (ISO 22738-compliant test cycle) |
| Poisoning Resistance | Validated against Pb, Si, P, and oil ash contaminants per SAE J1679 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PM1009 |
| Pricing | Available Upon Request |
| Detection Principle | Optical Transmission (Opposed-Beam) |
| Warm-up Time | 1 s |
| Operating Temperature | −10 °C to +60 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Storage Temperature | −20 °C to +80 °C |
| Supply Voltage | DC 5.0 V ± 0.25 V (Ripple < 50 mV) |
| Operating Current | < 60 mA |
| Output Signal | PWM (3.3 V logic level) |
| Response Time | < 200 ms |
| Dimensions (PCBA only) | 43 mm × 25 mm × 5 mm (W × H × D) |