| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBH |
| Price | USD 340 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range Options | 0–2% vol, 0–5% vol, 0–75% vol |
| Accuracy | ≤ ±0.06% vol (0.00–1.00% vol) |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Explosion Protection Rating | Ex ia II C T4 Ga |
| Output Interface | Dual-mode — analog (0–5 V / 4–20 mA) and digital (UART TTL/RS485) |
| Housing Material | Full-metal hermetic enclosure |
| Optical Design | Dual-beam NDIR with reference & measurement channels |
| Temperature Compensation | Full-range automatic compensation |
| Dimensions | Φ20 × 19 mm or Φ20 × 16.6 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBrH |
| Price | USD 295 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5% vol CH₃Br |
| Accuracy | ±0.06% vol (0–1% vol), ±6% of reading (1–5% vol) @ 25°C ±2°C, 101.3 kPa |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +70°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Explosion Protection | Exia II C T4 Ga |
| Output Options | Analog (0–5 V / 4–20 mA) and Digital (UART TTL/RS485) |
| Housing | All-metal, dual-beam optical architecture |
| Dimensions | Φ20 × 19 mm / Φ20 × 16.6 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SJH |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5% vol and 0–100% vol |
| Accuracy | ≤±0.06% vol (0.00–1.00% vol) |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Explosion Protection Rating | Ex ia II C T4 Ga |
| Dimensions | Φ20 × 19 mm / Φ20 × 16.6 mm (excluding pins) |
| Output Options | Analog (4–20 mA / 0–5 V) and Digital (UART TTL/RS485) |
| Housing Material | Hermetically Sealed Metal Enclosure |
| Calibration | Full-Range Temperature Compensation |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SRH |
| Price | USD 250 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Ranges | 0–5000 ppm |
| Accuracy | ±25 ppm or ±10% of reading (for ppm ranges) |
| Operating Temperature | −20 °C to +55 °C |
| Storage Temperature | −40 °C to +70 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Explosion Protection | Exia II C T4 Ga |
| Output Options | Digital (UART TTL/RS485) and Analog (0–5 V / 4–20 mA) |
| Housing | All-metal, dual-beam optical architecture |
| Dimensions | Φ20 × 19 mm / Φ20 × 16.6 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSU ADV Oxygen Sensor |
| Price | USD 47.20 (based on ¥330 at 1 USD = ¥7.0) |
| Detection Principle | Zirconia Solid Electrolyte (High-Temperature Nernst Principle) |
| Operating Voltage | DC 7.5 V |
| Supply Voltage Range | 10.8–16.5 V DC |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Thread Size | M18 × 1.5 |
| Heater Steady-State Power | 8.7 W |
| Nernst Cell Internal Resistance | 300 Ω |
| Measurement Accuracy (λ = 0.8) | Ip = −0.652 ± 0.032 mA |
| Measurement Accuracy (λ = 1.0) | Ip = −0.018 ± 0.008 mA |
| Measurement Accuracy (λ = 1.7) | Ip = 0.515 ± 0.022 mA |
| Lambda (λ) Measurement Range | 0.65 to ∞ |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS-AFR-01 |
| Operating Voltage | DC 9–12 V |
| Storage Temperature | −40 °C to 90 °C |
| Operating Exhaust Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18×1.5 |
| Heater Steady-State Power | 10 W |
| Measurement Accuracy (at λ = 1) | ±0.02 |
| Air–Fuel Ratio (AFR) Measurement Range | 0–2 (λ-equivalent) |
| Light-Off Time | < 15 s |
| Sensing Principle | Zirconia-based Solid Electrolyte (High-Temperature Nernst + Pump Cell Configuration) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ZS-ST-01 |
| Operating Principle | Zirconia Solid Electrolyte (Nernst Potential) |
| Supply Voltage | DC 12 V |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18×1.5 |
| Signal Output | Binary λ-switching voltage (≥750 mV at λ = 0.93–0.97 |
| Internal Resistance | ≤1 kΩ (at 150–930 °C) |
| Response Time (600 → 300 mV) | <150 ms |
| Response Time (300 → 600 mV) | <100 ms |
| Light-off Time | <15 s |
| Environmental Robustness | High tolerance to condensate, soot, and hydrocarbon fouling |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS-ST-09 |
| Application | Two-Wheeler Exhaust Lambda Monitoring |
| Detection Principle | Zirconia-Based Potentiometric (Limit-Current Type) |
| Operating Voltage | DC 12 V |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Installation Thread | M12 × 1.25 |
| Signal Output Voltage (λ = 0.93–0.97) | ≥750 mV |
| Signal Output Voltage (λ = 1.05–1.10) | 50 ± 30 mV |
| Internal Resistance | ≤1 kΩ (at 850 °C: ≤0.5 kΩ) |
| Response Time (600 → 300 mV) | <150 ms |
| Response Time (300 → 600 mV) | <100 ms (at 850 °C: <60 ms) |
| Light-off Time | <15 s |
| Exhaust Moisture & Deposit Tolerance | High |
| Compliance | Designed for ISO 8767, SAE J167, and GB/T 20071-2022 (Motorcycle Emission Control Systems) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ZS-WB4.2-01 (LUS4.2) |
| Detection Principle | Zirconia Solid Electrolyte High-Temperature Nernst Principle |
| Operating Voltage | DC 9 V |
| Storage Temperature | −40 °C to 90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18 × 1.5 |
| Heater Steady-State Power | 10 W |
| Nernst Cell Internal Resistance | 80 Ω |
| Lambda (λ) Measurement Range | 0.65 to ∞ |
| Lambda Accuracy | ±0.03 at λ = 0.8 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSU4.9-based Wide-Range Oxygen Sensor |
| Pricing | Available Upon Request |
| Detection Principle | Zirconia Solid Electrolyte (High-Temperature Nernst Principle) |
| Operating Voltage | DC 7.5 V |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18 × 1.5 |
| Heater Steady-State Power | 7.5 W |
| Nernst Cell Internal Resistance | 300 Ω |
| Lambda (λ) Measurement Range | 0.65 to ∞ |
| Lambda Accuracy | ±0.03 at λ = 0.8 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | LSF XFOUR |
| Detection Principle | Zirconia Solid Electrolyte (Nernst Principle) |
| Operating Temperature Range | 150–930 °C |
| Storage Temperature | −40 to 90 °C |
| Exhaust Gas Temperature Rating | Up to 850 °C |
| Output Voltage (λ = 0.93–0.97) | 1005 ± 40 mV |
| Output Voltage (λ = 1.05–1.10) | 190 ± 30 mV |
| Internal Resistance | ≤2.5 kΩ (at cold start), ≤0.5 kΩ (at 850 °C) |
| Response Time (700 mV ↔ 400 mV) | <100 ms (cold), <80 ms (hot) |
| Light-off Time | <12 s |
| Thread Size | M18 × 1.5 |
| Heater Integrated | Yes |
| Reference Air Supply | Pumped (electrochemical oxygen pumping) |
| Sensor Type | Limiting-current / Concentration-cell (switch-type) lambda sensor |
| Core Substrate | HTCC (High-Temperature Co-fired Ceramic) |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 81X30 |
| Measurement Capability | Planar (2D/3D) |
| Frame Rate | >100 Hz |
| Velocity Range | 0–0.5 m/s |
| Accuracy | ±1% of full scale |
| Measurement Area | 190 mm × 120 mm |
| Illumination Source | High-power pulsed LED array with fiber-coupled lens system |
| Camera | FlowSense USB 2M-165 (2 MP, global shutter, 165 fps @ full resolution) |
| Synchronization | Software-controlled via DynamicStudio v7.x |
| Data Acquisition & Analysis | DynamicStudio PIV software suite |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | MicroPIV |
| Measurement Domain | 15 µm × 15 µm to 3 mm × 3 mm |
| Velocity Range | 0–2 m/s |
| Accuracy | ±1% of measured velocity |
| Spatial Resolution | Down to ~1 µm (dependent on optics & particle seeding) |
| Temporal Resolution | Low-frequency operation (typically < 100 Hz, configurable via laser pulse separation and camera frame rate) |
| Optical Configuration | Inverted fluorescence microscope optimized for PIV |
| Camera Option | HiSense MkII sCMOS sensor with peak quantum efficiency of 72% |
| Upgrade Paths | Unstructured grid PIV, MicroLIF (Micro Laser-Induced Fluorescence) |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | MiniPIV |
| Measurement Plane | 2D/3D |
| Frame Rate | >100 Hz |
| Velocity Range | 0–5 m/s |
| Accuracy | ±1% of reading |
| Measurement Area | 150 mm × 120 mm |
| Camera | FlowSense USB 2M-165 (1920 × 1200 px, 165 fps) |
| Laser Source | RayPower (2/5/10 W, air-cooled, TEM₀₀ mode) |
| Software Platform | DynamicStudio |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Import Category | Imported |
| Model | Low-Frequency PIV |
| Measurement Capability | Planar (2D/3D) |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% |
| Measurement Area | 200 mm × 200 mm to 1000 mm × 1000 mm |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Denmark |
| Model | VV |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Velocity Range | 0–300 m/s |
| Measurement Volume | 200 mm × 200 mm × 40 mm |
| Accuracy | ±1% of measured velocity |
| Temporal Resolution | Low-frequency acquisition (configurable via camera framing rate and laser repetition rate) |
| Particle Seeding Density | 0.05–0.07 particles per pixel (PPP) |
| Camera Configuration | 2–4 synchronized high-speed CMOS cameras |
| Illumination | Volumetric light sheet or tomographic LED/laser array |
| Software Platform | DynamicStudio with GPU-accelerated volumetric reconstruction (up to 240 CUDA cores) |
| Brand | Dantec |
|---|---|
| Origin | Denmark |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMap |
| Pricing | Upon Request |
| OH Excitation Laser Energy | 22–25 mJ per Pulse |
| ICCD Gating Width | 3 ns |
| Photocathode Quantum Efficiency | ~30% |
| CCD Quantum Efficiency | ~70% |
| Synchronizer Timing Resolution | 250 ps |
| Brand | Dantsin |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 2020 / 3020 |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DaqLink |
| Pricing | Available Upon Request |
| Key | Channels: 8 |
|---|---|
| Sampling Resolution | 16-bit |
| Max Single-Channel Sampling Rate | 4,000 Hz |
| Internal Memory | 512 KB RAM (supports up to 100 logging sessions) |
| Battery | Rechargeable 7.2 V NiMH, ~25–40 h operation |
| Display | 64×128-pixel graphical LCD |
| Input Types | 0–24 mA, 0–50 mV, 0–10 V, NTC, PT-100, thermocouples (J/K/T), pulse/frequency (Ch1 only) |
| Accuracy | ±0.5% of full scale (typical across analog ranges) |
| Compliance | CE, FCC |
| Enclosure Rating | IP67 (with optional weatherproof housing) |
| Interface | USB 1.1 |
| Operating Temperature | 0–50 °C |
| Dimensions | 182 × 100 × 28 mm |
| Weight | 450 g |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CEM20 |
| Price | USD 1,120 (FOB) |
| Input Channels | 20 per module |
| Max. Modules per DT80 (v2+) | 5 |
| Max. Modules per DT85 (v2+) | 16 |
| Max. Analog Inputs | 300 (DT80), 960 (DT85) |
| Isolation | Dual-channel galvanic isolation per input pair |
| Input Configurations | 2 isolated differential or 3 shared single-ended per channel |
| Max. Input Voltage | 30 Vdc |
| Sampling Rate | 12 Hz (per CEM20) |
| Power Supply | 12 Vdc ±5% (from host or external) |
| Power Consumption | 0.36 W (active), <0.1 W (sleep mode) |
| Operating Temperature | −45 °C to +70 °C |
| Enclosure | Anodized aluminum housing with steel end plates |
| Dimensions | 180 × 100 × 50 mm |
| Weight | 0.55 kg |
| Communication Interface | Digital control via 5D/6D I/O lines |
| Max. Cable Distance (host to last CEM20) | 100 m |
| Addressing | 4-bit DIP switch (address range 1–15) |
| Status Indication | LED indicators for power, communication, and sampling activity |
| Included | Analog interface cable for DT80/DT85 host connection |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT80 |
| Analog Inputs | 15 single-ended / 10 differential / 5 three- or four-wire |
| Resolution | 8-bit |
| Max Sampling Rate | 40 Hz |
| Excitation Outputs | 5 V / 12 V selectable, up to 150 mA |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Communication Ports | RJ45 Ethernet, USB, RS232 (host), RS232/RS485/RS422 (configurable) |
| Protocols | MODBUS RTU (master/slave), MODBUS TCP/IP, SDI-12, ASCII |
| Network Support | HTTP, FTP, SMTP |
| Power Supply | 10–30 VDC |
| RTC Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Operating Temperature | −40 to +70 °C, 85% RH non-condensing |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 1.5 kg |
| Internal Storage | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB storage |
| Internal Battery | 6 V @ 1.2 Ah |
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DT80 Series 2 |
| Pricing | Upon Request |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT80G |
| Analog Inputs | 15 single-ended / 10 differential / 5 three- or four-wire |
| Resolution | 8-bit |
| Sampling Rate | up to 40 Hz |
| Vibrating Wire Channel | integrated, 500–5 kHz range, coil resistance 50–200 Ω, excitation pulse: 36 V @ 200 µs |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Communication | RJ45 (Ethernet), USB, RS232/RS485/RS422 |
| Protocols | MODBUS RTU/TCP, SDI-12, ASCII, HTTP, FTP, SMTP |
| Power | 10–30 VDC |
| Operating Temperature | −40 to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 1.5 kg |
| Internal Storage | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB drive |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Internal Battery | 6 V @ 1.2 Ah |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT82E |
| Analog Inputs | 6 single-ended / 4 differential / 2 three- or four-wire RTD channels |
| Resolution | 18-bit |
| Sampling Rate | up to 40 Hz |
| Excitation Outputs | 5 V / 12 V selectable, max 150 mA |
| Digital I/O | 8 configurable channels with 32-bit counter (100 kHz max) |
| Communication | RJ45 Ethernet, RS232 serial, SDI-12 master interface |
| Protocols | SDI-12, Modbus RTU (master), Modbus TCP/IP |
| Storage | 128 MB CompactFlash (upgradable), optional 8 GB USB flash |
| Operating Temperature | −40 °C to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 900 g |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Power Supply | 10–30 VDC |
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DT82e |
| Pricing | Upon Request |
| Brand | dataTaker |
|---|---|
| Origin | Imported |
| Model | DT82I |
| Analog Inputs | 6 single-ended / 4 differential / 2 three- or four-wire |
| Resolution | 18-bit |
| Sampling Rate | up to 40 Hz |
| Analog Output | 16-bit DAC, 0–10 V or 0–20 mA |
| Excitation Outputs | 5 V / 12 V selectable, max. 150 mA |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Communication Ports | RJ45, RS232 (host), RS232/RS485/RS422 |
| Protocols | MODBUS RTU (master/slave), MODBUS TCP/IP, ASCII, SDI12 |
| Power Supply | 10–30 VDC |
| Operating Temperature | −40 to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 180 × 137 × 65 mm |
| Weight | 900 g |
| Internal Storage | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB storage |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Built-in Battery | 6 V @ 1.2 Ah |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT85 |
| Analog Inputs | 48 single-ended / 32 differential / 16 three- or four-wire |
| Resolution | 18-bit |
| Sampling Rate | up to 40 Hz |
| Excitation Outputs | 5 V / 12 V, 150 mA max |
| Digital I/O & Counters | 32-bit, up to 100 kHz |
| Communication Ports | RJ45 (Ethernet), USB, RS232 (host), RS232/RS485/RS422 (multi-protocol) |
| Protocols | MODBUS RTU/TCP/IP, SDI-12, ASCII, HTTP, FTP, SMTP |
| Power Supply | 10–30 VDC |
| Operating Temperature | −40 °C to +70 °C |
| Enclosure Rating | IP54 |
| Dimensions | 300 × 137 × 65 mm |
| Weight | 2.5 kg |
| Internal Memory | 128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB storage |
| Real-Time Clock Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DT85 Series 2 |
| Pricing | Upon Request |
| Brand | DataTaker |
|---|---|
| Origin | Imported |
| Model | DT85G |
| Analog Input Channels | 48 single-ended / 32 differential / 16 three- or four-wire |
| Resolution | 18-bit |
| Sampling Rate | up to 40 Hz |
| Excitation Outputs | 5 V / 12 V, max 150 mA |
| Digital I/O & Counter | 32-bit, up to 100 kHz |
| Vibrating Wire Channel | integrated, 500–5000 Hz range, coil resistance 50–200 Ω, excitation pulse 36 V @ 200 µs |
| Communication | RJ45 (Ethernet), USB, RS232/RS485/RS422 |
| Protocols | MODBUS RTU/TCP, SDI-12, ASCII, HTTP, FTP, SMTP |
| Power | 10–30 VDC |
| Internal Battery | 6 V @ 4 Ah |
| Operating Temperature | −40 °C to +70 °C |
| Storage | 128 MB CF (upgradable to 4 GB), optional 8 GB USB drive |
| Enclosure Rating | IP54 |
| Dimensions | 300 × 137 × 65 mm |
| Weight | 2.5 kg |
| RTC Accuracy | ±1 min/year (0–40 °C), ±4 min/year (−40–70 °C) |