| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Julight Micro-VibroScope Series |
| Price | Upon Request |
| Measurement Principle | Non-contact Laser Doppler Vibrometry (LDV) with Integrated High-Resolution Optical Microscopy |
| Frequency Range | Up to 35 MHz |
| Displacement Resolution | 10 pm |
| Spot Size | < 4 µm |
| Maximum Velocity | ±40 m/s (at 3 MHz bandwidth) |
| Velocity Accuracy | ±1% of reading |
| Measurement Direction | Normal-component vibration only |
| Configuration Options | Single-point, 2D scanning, and 3D scanning modes available |
| Compliance | Designed for ISO 18431-1 (Vibration and shock — Signal processing), ASTM E1876 (Standard Test Method for Dynamic Young’s Modulus), and compatible with GLP/GMP-aligned data integrity workflows |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | MicroMRS-Lab (NMR-based micro-sensor platform) |
| Sample Volume Range | 0.1–500 nL |
| Operating Frequency Range | 120–1000 MHz |
| Effective Sensing Volume | 0.1–500 nL |
| Channel Configurations | 1–14 channels |
| Temperature Control Accuracy | ±0.5 °C |
| Compatibility | Standard NMR spectrometers (5 mm bore, broadband probe interfaces) |
| Biocompatibility | ISO 10993-compliant housing materials |
| Regulatory Context | Designed for GLP-compliant lab environments |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | Ndigo6G-12 Time Measurement & Frequency Analysis Card |
| Pricing | Available Upon Request |
| ADC Channels | 4 |
| TDC Channels | 4 |
| Gating Channels | 4 |
| Sampling Rate (Single Channel) | 6.4 GS/s |
| Multi-Channel Sampling Rate | 1.6 GS/s per channel |
| Resolution | 12 bits |
| TDC Bin Width | 12 ps |
| TDC Dual-Pulse Resolution | Typically 4 ns |
| TDC Readout Rate | 30 MHits/s |
| ADC Data Throughput | 6000 MB/s |
| Onboard Clock Stability | ±50 ppb (10 MHz internal or external reference) |
| Interface | PCIe 3.0 x8 |
| Onboard Memory | Calibrated buffer with real-time streaming capability |
| Trigger Flexibility | Adjustable trigger window, overlapping event support, programmable gate/veto logic, cross-channel and external digital trigger matrix |
| Brand | Auniontech |
|---|---|
| Model | Orchestra™ FROG |
| Type | Frequency-Resolved Optical Gating (FROG) Instrument |
| Spectral Range | 200 nm – 5 µm (configurable by module) |
| Pulse Duration Range | 2 fs – 4 ps |
| Minimum Input Pulse Energy | 2 nJ (TG/SHG-FROG modes), 10 nJ (basic SHG-FROG) |
| Temporal Resolution | 20 as per motor step |
| Scan Range | Up to 200 ps |
| Beam Diameter | 5 mm |
| Polarization Support | s- or p-polarized input |
| Weight | < 1 kg |
| Dimensions | 16 cm × 10 cm × 16 cm |
| Software | Integrated phase retrieval & full electric field reconstruction |
| Brand | Auniontech |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Semiconductor Thin-Film Metrology System |
| Pricing | Available Upon Request |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | VSM4000-SCAN-3D |
| Pricing | Upon Request |
| Scan Range | 0.1–5 m |
| Angular Scan Field | ±25° (X/Y) |
| Maximum Points per Axis | 1024 |
| Scan Speed | Up to 50 points/sec (standard) |
| Optical Configuration | Triple-head synchronized interferometric setup |
| Frequency Bandwidth | DC to 35 MHz |
| Software Modules | Flexible Grid Generation, Automated Raster/Path Scanning, Modal Analysis (optional), Full-Field Stress Mapping (optional), 3D Animation & Visualization Engine |
| Rotational Tracking Option | Supported (elliptical/circular trajectory compensation, software-based alignment, no mechanical retro-reflector required) |
| Brand | Auniontech |
|---|---|
| Model | WaveHitMAX |
| Type | Fully Automated Modal Excitation Impulse Hammer |
| Force Sensing | Single-Axis Piezoelectric Load Cell (2.224 N & 444 N Full-Scale Options) |
| Hammer Tip Materials | Metal (Hard), Plastic (Medium), Rubber (Soft), Ultra-Soft Rubber |
| Tip Mass Add-ons | 12 g & 60 g |
| Trigger Interface | M12 Digital Input |
| Signal Output | BNC (IEPE-compatible) |
| Connectivity | Ethernet, SD Card Slot |
| Compliance | Designed for ISO 18431-1, ASTM E2534, and modal testing workflows compliant with ISO 7626-2 and ISO 10816 series |
| Brand | Avisoft |
|---|---|
| Origin | Germany |
| Model | 116h / 416h / 816h / 1216h |
| Sampling Frequency Range | 20 Hz – 460 kHz (116h) |
| ADC Resolution | 16-bit |
| Input Sensitivity Range | −43.2 dBV to −3.2 dBV |
| Gain | 40 dB |
| Self-Noise | 18 dB SPL |
| Microphone Sensitivity | 500 mV/Pa |
| Connector | XLR-5 male |
| Dimensions (Microphone) | 36 × 36 × 60 mm |
| Weight (Microphone) | 65 g |
| Weight (116h Host) | 205 g |
| Power | USB-powered (UltrasoundGate host), optional USB power adapter for field use |
| Brand | Avisoft |
|---|---|
| Origin | Germany |
| Model | UltrasoundGate 116 |
| Sampling Rate | 20 Hz – 460 kHz |
| Weight | 205 g |
| Resolution | 16-bit |
| Input Sensitivity (max) | −43.2 dBV |
| Input Sensitivity (min) | −3.2 dBV |
| Gain | 40 dB |
| Features | Overload Indicator, Peak dB LED, Real-time Audio Monitoring & Streaming, Adjustable Gain |
| Brand | Aiyao Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | AY1000 |
| Output Interface | RS422 Digital Output |
| Operating Frequency Range | ≥0.01 Hz |
| Noise Floor | Ultra-Low (Typ. <10 ng/√Hz below 1 Hz) |
| Form Factor | Miniaturized, Low-Power, Lightweight Design |
| Compliance | Fully Domesticated Architecture |
| Brand | AZ (Beijing Aozuo) |
|---|---|
| Origin | Germany |
| Manufacturer | AZ Instrument Co., Ltd. |
| Model | 3D-Disdrometer |
| Measurement Area | 200 cm² |
| Sample Volume | 1 L |
| Particle Diameter Range | 0.08–40 mm |
| Fall Velocity Range | 0.2–20 m/s |
| Rainfall Intensity Range | 0.001–>1000 mm/h |
| Resolution (Diameter) | ±0.05 mm for particles <1.2 mm |
| 3D Trajectory Detection | Yes |
| Operating Temperature | −40°C to +50°C |
| Humidity Range | 0–100% RH |
| Power Supply Options | 24 VAC/DC (1 A) or 85–264 VAC / 120–370 VDC (0.2 A @ 230 VAC) |
| Heating Function | Integrated camera heater |
| Communication Interface | RS-485, full/half-duplex, ASCII protocol, 1200–115200 baud |
| Output Standards | SYNOP Table 4680/4677, METAR Table 4678 |
| Weight | 7.5 kg |
| Mounting Tube Diameter | 48–70 mm |
| Brand | AZ (Beijing AoZuo) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ENVIdata-DT Rod-Type |
| Price | USD 140 (approx. ¥1000) |
| Brand | AZ (Beijing Aozuo Ecological Instruments Co., Ltd.) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AZ-RF |
| Price | Upon Request |
| Rainfall Intensity Range | 0.2–240 mm/h |
| Raindrop Diameter Range | 0.1–5 mm |
| Rainfall Uniformity | ≥90% (scanning-type configuration) |
| Measurement Resolution | 0.01 mm (rainfall depth), 0.01 mm/h (intensity), 1 mm/h (intensity control step) |
| Control Levels | Up to 120 programmable intensity steps |
| Operating Height | 2.5–3.2 m (adjustable) |
| Coverage Area | Configurable up to 2 × 6 m² (12 m²) |
| Power Supply | 380 V AC (fixed), 24 V DC (portable) |
| Optional Disdrometer | Laser-based, 0.16–8 mm particle sizing, 0.2–20 m/s velocity detection, 440-class particle classification |
| Brand | Microphotons |
|---|---|
| Focal Length | 35 mm (typical for AZURE-3514SWIR series) |
| Spectral Range | 900–1700 nm |
| Mount Type | C-Mount |
| Design Optimized For | InGaAs Sensor Arrays |
| Transmission Efficiency | >85% (avg. across band) |
| Working Distance | Fixed Focus (Standard Configuration) |
| Environmental Rating | Industrial Grade, Non-Sealed (Indoor Use) |
| Brand | Baineng |
|---|---|
| Origin | Shanghai, China |
| Model | BN-RL |
| Type | Non-contact Pulse Radar Water Level Sensor |
| Measurement Principle | 26 GHz Pulsed Time-of-Flight (PTOF) |
| Range Options | 0–15 m / 0–30 m / 0–45 m |
| Accuracy | ±2 mm (for 0–15 m range) |
| Beam Angle | 6° or 8° |
| Output Interfaces | RS-485 (Modbus RTU), 4–20 mA (optional), 0–5 V (optional) |
| Power Supply | 12 VDC (RS-485 mode) or 24 VDC (4–20 mA loop-powered) |
| Max. Current Consumption | 12 mA |
| Operating Temperature | −40 °C to +100 °C |
| Enclosure Rating | IP68 |
| Wave Filtering | Built-in dynamic surface wave suppression algorithm |
| Maintenance | Maintenance-free design |
| Key | Origin: Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BCG450 |
| Pricing | Available Upon Request |
| Brand | BEAMEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BOS-25 |
| Price | USD 9,999 |
| Brand | Beijing Guangjing / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BEST-121 |
| Price | USD 1,700 (FOB) |
| Test Voltage Range | DC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Accuracy | ±1% (typical), ±10–20% depending on range and voltage |
| Input Impedance | >10¹⁵ Ω |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ~5 W |
| Dimensions (L×W×D) | 355 mm × 320 mm × 145 mm |
| Weight | 6 kg (main unit) |
| Compliance | GB/T 1410-2006, ASTM D257, ISO 3915, IEC 62631-3-1 |
| Brand | Belfort |
|---|---|
| Origin | USA |
| Model | AEPG II |
| Operating Temperature Range | -55 °C to +55 °C |
| Collection Area | 200 cm² (16 cm diameter) or 50.26 in² (8 in diameter) |
| Precipitation Rate Range | 0.25 mm/h to 3040 mm/h |
| Resolution | 0.025 mm (0.001 in) |
| Accuracy | ±0.25 mm (±0.01 in) or ±0.1% FS |
| Repeatability | ±0.25 mm (±0.01 in) |
| Output | RS-232 (configurable units: mm/in, mass, frequency, collector temperature) |
| Power Supply | 8–18 VDC (3 W nominal) |
| Optional Heater | 115 VAC/60 Hz/2 A or 12 VDC @ 30/60/90 W |
| Enclosure Material | UV-stabilized high-strength thermoplastic over aluminum frame |
| Weight | 13 kg (28.5 lb) |
| Compliance | WMO No. 8, NOAA/NWS Technical Memorandum NWS OH-1, ASTM D7297 |
| Brand | Benchmark |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | W3002A-120ACS |
| Pricing | Available Upon Request |
| Brand | Biaozhuo |
|---|---|
| Origin | Shanghai, China |
| Model | JJ-2A |
| Measurement Range | 0°–360° |
| Angular Resolution | <1 arcsecond |
| Accuracy | <4 arcseconds |
| Base Material | Granite |
| Main Shaft Bearing | Dual-sphere rolling mechanism |
| Operating Temperature | 20 °C ±3 °C |
| Relative Humidity | 40–60 % RH |
| Mass | 350 kg |
| Brand | BOROSA |
|---|---|
| Country of Origin | Germany |
| Model | L200 |
| Operating Pressure | Ambient (1 atm) |
| Frequency | ~40 kHz |
| Temperature Range | −20 °C to +180 °C |
| Sample Type | Liquids and Solids |
| Levitation Mode | Standing-wave acoustic levitation (ultrasonic, single-axis) |
| Software Functions | Automated droplet detection, contour analysis, real-time dimensional tracking (axial/radial diameter), volume-time curve fitting, diffusion/transport coefficient derivation |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | BOROSA |
|---|---|
| Origin | Germany |
| Model | L800 |
| Pressure Range | 0.10–20 MPa |
| Temperature Range | −20 °C to +180 °C |
| Droplet Diameter Capacity | 0.7–4 mm |
| Sample Chamber Material | Titanium Alloy with Triple Sapphire Windows |
| Compliance | Designed for ISO/IEC 17025-aligned research environments, supports GLP-compliant data traceability |
| Brand | Bt Fluid |
|---|---|
| Model | CW |
| Wavelength | 532 nm |
| Output Power | 1–20 W (custom higher power available) |
| Operation Mode | CW, TTL-triggered or analog-modulated pulsed output |
| Beam Divergence | <4 mrad |
| Beam Diameter | 4 mm |
| Sheet Thickness | <1 mm |
| Coating | AR-coated for 532 nm |
| Spherical Lens Focal Lengths | 500 mm, 1000 mm, 1500 mm |
| Cylindrical Lens Focal Lengths | −10 mm (37° divergence), −15 mm (24°), −25 mm (15°) |
| Origin | Beijing, China |
| Lead Time | 6 weeks |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | I-300 Pro |
| Measurement Principle | Capacitive Absolute Pressure Sensing |
| Pressure Range | 1400–0 mbar (hPa) / 1050–0 Torr |
| Control Range | 1100–1 mbar (hPa) / 825–1 Torr |
| Pressure Accuracy | ±2 mbar |
| Vacuum Port | GL14 |
| Display | 7.0-inch TFT touchscreen |
| Power Supply | 30 VDC ±5% |
| Power Consumption | 10 W |
| Data Storage | 1 GB SD card (removable) |
| Enclosure Rating | IP21 |
| Certifications | CE, CSA |
| Dimensions (W×H×D) | 122 × 221 × 50 mm |
| Weight | 600 g |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | I-300 |
| Measurement Principle | Capacitive Absolute Pressure Sensing |
| Pressure Range | 1400–0 mbar (hPa) / 1050–0 Torr |
| Control Range | 1100–1 mbar (hPa) / 825–1 Torr |
| Pressure Accuracy | ±2 mbar |
| Vacuum Port | GL14 |
| Display | 4.3-inch TFT touchscreen |
| Power Supply | 30 VDC ±5% |
| Power Consumption | 3 W |
| IP Rating | IP21 |
| Certifications | CE, CSA |
| Dimensions (W×H×D) | 121 × 141 × 50 mm |
| Weight | 400 g |
| Brand | CAMECA |
|---|---|
| Origin | France |
| Model | IMS 7f-Auto, LEAP 5000 XR / XS / R |
| Type | Secondary Ion Mass Spectrometry (SIMS) and Laser/Field-Assisted Atom Probe Tomography (APT) Platforms |
| Compliance | ASTM E1527, ISO/IEC 17025, GLP/GMP-ready data audit trails, FDA 21 CFR Part 11–compliant software options |
| Sample Form | Bulk solids, thin films, epitaxial layers, semiconductors (Si, III-V, II-VI), metals, ceramics, glasses, insulators |
| Depth Resolution | <0.3 nm (SIMS) |
| Spatial Resolution | <0.3 nm (APT, 3D) |
| Detection Limit | Sub-ppq (SIMS) |
| Throughput | Fully automated multi-sample analysis chain |
| Reproducibility | RSD < 0.5% (SIMS depth profiling) |
| Key | Brand: Campbell |
|---|---|
| Origin | USA |
| Model | CR1000Xe |
| Operating Temperature (Standard) | -40 to +70°C |
| Operating Temperature (Extended) | -55 to +85°C |
| Analog Inputs | 16 single-ended or 8 differential, plus 2 dedicated 0–20 mA / 4–20 mA current inputs |
| ADC Resolution | 24-bit |
| Max Scan Rate | 100 Hz |
| Communication Interfaces | Ethernet, USB Micro-B, RS-232/RS-485/RS-422, CPI, CS I/O, SDI-12, I²C, SPI |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Power Input | 10–36 VDC |
| Real-Time Clock Accuracy | ±3 min/year (GPS optional for ±10 µs) |
| Enclosure | Anodized aluminum with RF-shielded stainless steel electronics housing |
| Dimensions | 23.8 × 10.1 × 6.2 cm |
| Weight | 0.86 kg |
| Brand | Campbell |
|---|---|
| Origin | USA |
| Model | CR300 |
| CPU | ARM Cortex-M4 @ 144 MHz |
| Internal Memory | 80 MB data storage, 5 MB program storage, 2 MB OS storage |
| Clock Accuracy | ±1 minute/month |
| USB Interface | Micro-B, USB 2.0 Full-Speed (12 Mbps) |
| Power Input | 12 V terminal or 12 V battery/UPS |
| Excitation Output | 1 × switched 12 V (500 mA @ 20°C) |
| Analog Inputs | Differential, ±34 mV range, 230 nV resolution, accuracy ±(0.04% of reading ± 6 µV) at 0°–40°C |
| Operating Temperature | –40° to +70°C |
| Dimensions | 14 × 7.6 × 5.1 cm |
| Weight | 242 g |
| Communication Protocols | PPP, ICMP/Ping, Auto-IP (APIPA), IPv6, UDP, TCP, TLS, DHCP Client, SLAAC, DNS Client, Telnet, PakBus, SDI-12, Modbus RTU/ASCII/TCP, DNP3 |
| Environmental Protection | High-level surge and ESD protection |
| Data Transmission | Encrypted email & alarm notifications via TLS |
| Configuration | USB direct-to-PC |
| Compliance | Designed for long-term unattended field deployment in hydrological, meteorological, environmental, and industrial monitoring applications |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR1000X |
| Operating Temperature Range | –40 to +70 °C (standard), –55 to +85 °C (extended) |
| Analog Inputs | 16 single-ended or 8 differential |
| ADC Resolution | 24-bit |
| Max Scan Rate | 100 Hz |
| Communication Interfaces | Ethernet, USB Micro-B, RS-232/RS-485/RS-422, CPI, SDI-12, PakBus, Modbus TCP/RTU, DNP3, MQTT, NMEA 0183, I²C, SPI |
| Real-Time Clock Accuracy | ±3 min/year (±10 µs with optional GPS synchronization) |
| Power Supply | 10–18 VDC |
| Idle Current Draw | <1 mA @ 12 VDC |
| Dimensions | 23.8 × 10.1 × 6.2 cm |
| Weight | 0.86 kg |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |