Particle/Powder Analysis Instruments
Filter
Showing 511–540 of 969 results
| Brand | Particle Labs |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CVS-S |
| Instrument Type | Optical Particle Visualization System |
| Detection Principle | Widefield Brightfield Microscopy with High-Sensitivity CMOS Imaging |
| Minimum Resolvable Particle Size | ~0.1 µm (in optimal contrast conditions) |
| Imaging Modality | Real-time, Non-contact, Laser-Free Visual Monitoring |
| Form Factor | Compact Illumination Unit + Integrated Camera Module |
| Compliance Context | Supports ISO 14644-1 Class 3–5 environments, ASTM E2904-21 (Standard Guide for Microscopic Particle Characterization), and GMP/GLP-aligned documentation workflows |
| Brand | Particle Metrix |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZetaView® Evolution |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–13 |
| Operating Temperature Range | 5°C to 55°C |
| pH Resolution | 1–13 |
| Temperature Resolution | 0.1°C |
| Size Accuracy | ±5 nm |
| Size Repeatability | ±2 nm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ParticleMaster inspex |
| Dispersion Method | Dry & Wet |
| Measurement Range | >5 µm |
| Repeatability | <1% |
| Measurement Time | 30–60 s |
| Compliance | IP54 |
| Light Source | LED (Eye-Safe) |
| Calibration | Factory-Preconfigured Particle Size & Depth-of-Field Calibration |
| Installation | Fixed-Mount Integrated Probe with Coaxial Illumination |
| Brand | SOOHOW INSTRUMENT |
|---|---|
| Model | PC-VES |
| Type | Portable Pressure Sampling Module for Optical Particle Counters |
| Max. Operating Pressure | 0–0.5 MPa |
| Power Supply | 100–265 VAC / 24 VDC / Optional External Li-ion Battery |
| Ambient Temperature Range | –20 to +60 °C |
| Compatible Fluid Viscosity | up to 400 cSt |
| Construction | Integrated High-Reliability Micro Air Compressor |
| Visual Monitoring | Transparent Observation Window |
| Origin | Jiangsu, China |
| Manufacturer | SOOHOW INSTRUMENT Co., Ltd. |
| Measurement Principle | Mie Scattering Theory (Full-Range) |
|---|---|
| Particle Size Range | 0.1–450 µm (Lab Mode) |
| Detection Channels | 70 Main + 24 Side Array (Lab), 15 User-Configurable Channels (Online) |
| Laser Source | Semiconductor Diode, 760 nm, 5 mW, >20,000 h Lifetime |
| Sample Flow Rate | 70 mL/min (Online) |
| Operating Temperature | 10–50 °C |
| Max Pressure | 100 psi (0.675 MPa) |
| Power Supply | 85–250 VAC, 50–60 Hz |
| Communication Interface | RS-485 |
| Compliance | ISO 13320, NIST-Traceable Calibration |
| Enclosure Materials | Teflon®, Stainless Steel, Borosilicate Glass, BUNA-N |
| Dimensions (Online Unit) | 320 × 110 × 110 mm |
| Weight (Online Unit) | 3 kg |
| Brand | Pharma Test |
|---|---|
| Origin | Germany |
| Model | PTG-S5 |
| Instrument Type | Fully Automated Powder Flowability Analyzer |
| Standards Compliance | USP <1174>, EP <2.9.36>, EP <2.9.16>, ISO 4324 (1983) |
| Funnel Volume | 450 mL |
| Heap Angle Range | 1–65° |
| Heap Volume Range | 0.1–275 mL |
| Bulk Density Range | 0–6.0 g/mL |
| Sample Mass Range | 1 mg–325 g |
| Flow Time Range | 0.1–999 s |
| Nozzle Orifices | 6, 8, 10, 15, 25 mm |
| Display | 7-inch color touchscreen |
| Dimensions (L×W×H) | 50 × 55 × 90 cm |
| Construction | Electropolished stainless steel housing |
| Software | 21 CFR Part 11 compliant with audit trail, electronic signatures, and secure data storage |
| Brand | Huironghe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRH-HRH1 |
| Pricing | Available Upon Request |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | PN3621 |
| Detection Angles | 21 fixed angles (7° to 165°) |
| Configuration Options | Offline-only and Offline/Online Hybrid Modes |
| Compliance | Designed for integration with SEC/GPC, FFF, and HPLC systems |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2QY |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-stage electromagnetic + piston pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Compliance | Designed for ISO 14644-1 cleanroom monitoring, USP <788> & <789>, ASTM F3239, and semiconductor-grade ultrapure water (UPW) validation protocols |
| Brand | POWEREACH |
|---|---|
| Model | JCJ04 |
| Type | Gravitational Sedimentation Particle Size Analyzer |
| Origin | Shanghai, China |
| Measurement Principle | Gravitational sedimentation (Stokes’ law-based) |
| Particle Size Range | 1–60 µm |
| Maximum Sample Mass Capacity | 0–100 g (selectable) |
| Sensitivity | 0.1 mg |
| Data Acquisition Interval | 0.5 s |
| Sample Vessel | 500 mL calibrated glass cylinder |
| Calibration Weights | 0.5 g, 10 g, 50 g, 100 g |
| Data Output | Real-time sedimentation curve, D10/D50/D90, mean diameter, particle size distribution histogram, cumulative distribution, error estimation |
| Software Functions | Auto-zero, tare, self-calibration, alarm threshold setting, curve storage/retrieval, statistical analysis, report generation & printing |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JN01A |
| Zeta Potential Measurement Principle | Mass-Exchange Electrophoresis |
| Sample Concentration Range | High-concentration dispersions (undiluted, slurry-state) |
| pH Range | Not specified |
| Compliance | Designed for ASTM D4187, ISO 13099-2, and GLP-compliant workflows requiring raw-state dispersion analysis |
| Interface | RS232 (COM port) + USB |
| Software | JN01.exe (Windows XP / 32-bit Windows 7 compatible) |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94 |
| Measurement Principle | Microelectrophoresis (Video-Based Particle Tracking) |
| Compliance | GB/T 32668–2016 (National Standard for Colloidal Particle Zeta Potential Analysis – Electrophoretic Method) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Operating Temperature Range | Ambient to 35 °C |
| Zeta Potential Accuracy | Systematic error ≤5% |
| pH Range | 1.6–13.0 (typical operational range: 2.0–12.0) |
| Sample Volume per Test | 0.5 mL |
| Optical Magnification | Up to 1200× |
| Imaging System | USB Digital CCD with Customized Micrometer Grid Calibration |
| Electrode Configuration | Integrated Ag, Pt, and Ti/POM electrodes in open-cell electrophoresis chamber |
| Voltage Control | Adjustable DC bias with polarity reversal (0.30–1.20 s interval) |
| Temperature Compensation | Real-time thermistor-based ambient temperature sampling |
| Software Platform | Unified cross-model analysis suite with GLP-compliant data logging and audit trail capability |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixels/µm |
| System Accuracy | ±5% relative error (per GB/T 32668-2016 validation protocol) |
| Particle Size Applicability | 0.5–20 µm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V AC, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H2-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixel/µm |
| Particle Size Range | 0.5–20 µm |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Compliance | GB/T 32668–2016 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94J-1K20X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| System Accuracy | ≤5% systematic error |
| Particle Size Applicability | 0.1–10 μm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JS94J2-1K20X |
| Zeta Potential Range | ±200 mV (typical, per GB/T 32668-2016 calibration protocol) |
| pH Range | 1.6–13.0 (standard operation: 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| Microscope System | WDK Japan high-magnification optical module, working distance 7 mm |
| System Accuracy | ≤5% relative error (per ISO 13099-2:2012 validation methodology) |
| Particle Size Applicability | 0.1–10 μm (aqueous & organic dispersions) |
| Power Consumption | <150 W, 220 V / 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94K-3H20X |
| Zeta Potential Range | ±200 mV (typical, inferred per ISO 13099-2) |
| pH Range | 1.6–13.0 (standard operation 2.0–12.0, resolution 0.1) |
| Temperature Range | Ambient to 35 °C (measurement resolution 0.1 °C) |
| Particle Size Compatibility | 0.2–50 µm (aqueous dispersions) |
| Optical Resolution | 1.93–12 pixels/µm (motorized zoom optical system) |
| Power Consumption | <150 W |
| Compliance | GB/T 32668–2016, ISO 13099-2:2012, ASTM D7825–14 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94K2-3H20X |
| Zeta Potential Range | ±200 mV (typical, system-limited) |
| pH Range | 1.6–13.0 (standard operation 2.0–12.0, resolution 0.1) |
| Temperature Range | Ambient to 35 °C (readout resolution 0.1 °C) |
| Particle Size Compatibility | 0.2–50 µm |
| Optical Resolution | 1.93–12 pixels/µm (motorized zoom optical system) |
| Power Consumption | <150 W |
| Compliance | GB/T 32668–2016 (General Rules for Zeta Potential Analysis of Colloidal Particles by Electrophoresis) |
| System Accuracy | ±5% relative error (per certified reference dispersions under controlled conditions) |
| Sample Volume per Measurement | 0.5 mL |
| Voltage Polarity Switching Interval | 0.30–1.20 s (adjustable) |
| Measurement Time per Cycle | 3–10 s |
| Light Source | Low-power semiconductor blue/green LED (non-thermal, near-field illumination) |
| Brand | PS |
|---|---|
| Origin | Switzerland |
| Model | XPT-CP&CV |
| Product Type | Intelligent Online Analyzer |
| Display | Digital |
| Measurement Range | 10 µm – 3 mm |
| Compliance | ASTM E2457, ISO 13322-2, FDA 21 CFR Part 11 (with hardware token & electronic signature) |
| Configuration Options | XPT-P (in-process probe), XPT-C (suspension flow cell), XPT-CP (powder feeder + vibratory dosing), XPT-CV (Venturi vacuum-sampling closed-loop system) |
| Enclosure Rating | IP65 (XPT-CV), Stainless Steel Housing |
| Imaging | High-speed CCD with ultra-short shutter time or pulsed LED illumination |
| Frame Rate | ≥30 fps |
| Data Throughput | Thousands of particles analyzed and stored per second |
| Software Architecture | Parallelized real-time image acquisition and analysis engine |
| Brand | PSS (Particle Sizing Systems) |
|---|---|
| Model | AccuSizer 780 A9000 FX-MD |
| Detection Principle | Focused Light Obscuration & Single Particle Optical Sizing (SPOS) |
| Size Range | 0.6 µm – 20 µm |
| Maximum Sample Concentration | 1 × 10¹² particles/mL |
| Number of Adjustable Channels | 32 user-defined |
| Flow Rate | 15 – 180 mL/min |
| Sample Volume | 2 – 10 mL |
| Diluent | Ultrapure water (standard), organic solvents (optional) |
| Power Supply | 100–120 VAC, 60 Hz or 220–240 VAC, 50 Hz |
| Dimensions (Counter Unit) | 20 cm × 45 cm × 20 cm |
| Dimensions (Auto-Dilution Unit) | 25 cm × 45 cm × 56 cm |
| Weight | ~30 kg |
| Compliance | ISO 21501-4, USP <788>, <789>, ASTM F2149, FDA 21 CFR Part 11 ready |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Nicomp 380 |
| Pricing | Available Upon Request |
| Brand | Particle Sizing Systems (PSS), USA |
|---|---|
| Origin | USA |
| Model | Nicomp ZLS |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–14 |
| Temperature Range | 0–90 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | 99% |
| Repeatability | 99% |
| Brand | PULL |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | PS8011 |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 0.01–3500 µm |
| Repeatability | ±1% RSD |
| Measurement Time | ≤10 seconds |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Standards Compliance | ISO 4406:1999, NAS 1638, GJB 420B, GJB 380, GB/T 14039–2002, GB/T 18854–2002 (ISO 11171:1999), JJG 066–95 |
| Detection Range | 1 µm to 450 µm |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channel Configuration | 8 user-definable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min (electromagnetically regulated piston pump) |
| Sampling Volume | 1 mL to unlimited (programmable) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Pressure Range | –0.6 to +0.7 MPa (integrated positive/negative pressure pretreatment system) |
| Max. Fluid Viscosity | ≤350 cSt |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temperature Range | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Data Output | Onboard thermal printer, RS232 interface, histogram & distribution curve generation |
| Calibration Traceability | Certified by CALIBRATION STATION NO. 116, National Defense Science & Technology Industry Particle Metrology Level-1 Station (Aviation Industry Particle Metrology Center) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CCACS1.0 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Channel Count | 1000 adjustable channels |
| Size Range | 0.1 µm (c) to 100 µm (c), customizable bins (e.g., 4–128 bins) |
| Resolution | >95% |
| Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Sample Flow Rate | 5–1500 mL/min |
| Viscosity Range | Offline 0–99 mm²/s |
| Temperature Range | Fluid 0–80 °C |
| Sampling Precision | <±1% |
| Output Interfaces | RS232, RS485, USB, LAN, 4–20 mA analog, MODBUS protocol |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, GBW reference materials |
| Compliance | GB/T 11446.9, GJB 420B-2006, HB 6639/6649, QJ 2850/3024, MIL-STD-1246C, SAE AS4059F, NAVAIR 01-1A-17, ROCT 17216-2001 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | CCACS1.0-01 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Channel Count | 1000 adjustable channels |
| Size Range | 0.1 µm (c) to 100 µm |
| Resolution | >95% |
| Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% error) |
| Sample Flow Rate | 5–1500 mL/min |
| Viscosity Range | 0–99 mm²/s (offline), up to 500 mm²/s (pressurized) |
| Temperature Range | Fluid 0–80°C, Ambient −15–50°C |
| Calibration Standards | JJG 1061, ISO 21501-4, GB/T 11446.9, GJB 420B-2006, SAE AS4059F, MIL-STD-1246C, HB 6639/HB 6649, NAVAIR 01-1A-17 |
| Compliance | GLP/GMP-ready data integrity, 21 CFR Part 11-compatible audit trail (via optional software module) |
| Interface | RS232/RS485, USB, LAN, 4–20 mA analog output, MODBUS protocol |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | DPC-1511 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Laser Diffraction & Dynamic Light Scattering (DLS) / Flow Imaging |
| Test Range | 1 nm – 2000 µm (configurable sub-ranges: 1–10,000 nm |
| Detection System | 7th-Generation Dual-Laser Narrow-Beam Sensor |
| Compliance | ISO 13320, ISO 13321, SY/T 5329-2012, SY/T 6596-2016 |
| Repeatability | ≤ ±1% for D50 (certified reference materials) |
| Sample Throughput | ≤ 2 min per sample |
| Power Supply | AC 220 V ±10%, 50 Hz, 300 W |
| Operating Environment | 10–30 °C, RH < 85%, vibration-free, EMI-shielded, grounded power |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-1511 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–500 µm |
| Repeatability | <1% |
| Measurement Time | 60 sec |
| Detection Principle | Optical Diffraction & Scattering / Laser Flow Imaging |
| Compliance | ISO 13320, ISO 13321 |
| Sample Throughput | One sample per ≤2 min |
| Software Interface | Bilingual (English/Chinese), Windows-compatible |
| Reporting | D3, D10, D25, D50, D75, D80, D90, D97, D100, Span, Specific Surface Area, Aspect Ratio, Circularity Distribution |
| Brand | PULUODY |
|---|---|
| Model | DPC-1513 |
| Origin | Shaanxi, China |
| Instrument Type | Laboratory Laser Diffraction & Flow Imaging Hybrid Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | <5% (D50) |
| Measurement Time | ≤30 s per sample |
| Detection Principle | Laser Diffraction (ISO 13320 compliant) + Hydrodynamic Focusing Flow Imaging (ISO 13321 compatible) |
| Sample Introduction | Static cuvette & recirculating wet dispersion unit |
| Software Platform | Windows-native, bilingual (EN/CN), 20 report templates |
| Compliance | SY/T 5329–2012, Q/SY 01004–2016, SY/T 6596–2016, SY/T 5523–2016 |
| Power Supply | AC 220 V ±10%, 50 Hz, 300 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-1513-1 |
| Measurement Principle | Optical Diffraction & Scattering (ISO 13320) / Laser Flow Imaging (ISO 13321) |
| Dynamic Range | 1 nm – 2000 µm (configurable sub-ranges: 1–10,000 nm |
| Repeatability | ≤ ±1% RSD for D50 (certified reference materials) |
| Sample Throughput | ≤2 min per analysis |
| Compliance | SY/T 5329–2022, SY/T 5523–2016, Q/SY 01004–2016, ISO 13320, ISO 13321 |
| Detector | 7th-generation dual-laser narrow-beam photodetector |
| Software | Windows-compatible bilingual (EN/CN), 20 report templates, automated workflow (alignment, background, concentration adjustment, acquisition, analysis, cleaning) |
| Power | AC 220 V ±10%, 50 Hz, 300 W |
| Operating Environment | 0–40 °C, clean lab environment |
