Particle/Powder Analysis Instruments
Filter
Showing 421–450 of 969 results
| Brand | MAS |
|---|---|
| Origin | USA |
| Model | ZetaFinder ZF400 |
| Zeta Potential Range | ±500 mV |
| pH Range | 0–14 |
| Temperature Range | 0–90 °C |
| pH Resolution | ±0.1 |
| Temperature Resolution | ±0.1 °C |
| Accuracy | ±2% |
| Repeatability | ±2% |
| Particle Size Range | 5 nm – 1000 µm |
| Conductivity Range | 0–10 S/m |
| Sample Concentration | 0.1–60 vol% |
| Sample Volume | 30–230 mL |
| Measured Parameters | Particle Size Distribution, Zeta Potential, Isoelectric Point (IEP), Electroacoustic Amplitude (E5A), Conductivity, pH, Temperature, Acoustic Attenuation, Solid Content |
| Brand | MAS |
|---|---|
| Origin | USA |
| Model | ZetaFinder ZF400 |
| Zeta Potential Range | ±500 mV |
| pH Range | 0–14 |
| Temperature Range | 0–90 °C |
| pH Resolution | ±0.1 |
| Temperature Resolution | ±0.1 °C |
| Accuracy | ±2% |
| Repeatability | ±2% |
| Particle Size Range | 1 nm – 30 µm |
| Sample Concentration Range | 0.1–60% w/v |
| Measurement Principle | Electroacoustic Spectroscopy (EAS) & Colloidal Vibration Current (CVI) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 17-56 |
| Pricing | Available Upon Request |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Optical Airborne Particle Counter System |
| Model | MET ONE FMS |
| Instrument Category | Optical Particle Counter |
| Compliance | ISO 14644-1, ISO 21501-4, FDA 21 CFR Part 11, EU GMP Annex 1 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyViewer 400 |
| Instrument Type | In-line Dynamic Imaging System |
| Number of Lenses | 1 |
| Field of View | 1100 µm × 800 µm (±50 µm) |
| Image Resolution | 2200 × 1700 pixels |
| Sample Dispersion Method | In-situ liquid-phase flow-through measurement |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EasyViewer100 |
| Application Field | Pharmaceutical |
| Instrument Type | Dynamic |
| Number of Lenses | 1 |
| Measurement Range | 1.5 µm – 1 mm |
| Sample Dispersion Method | In-line liquid-phase measurement |
| Image Resolution | 1.5 µm |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 5390 |
| Principle | Electrical Sensing Zone (Coulter Principle) |
| Size Range | 0.4–1200 µm (20:1 to 30:1 dynamic range per orifice) |
| Concentration Range | 1–1000 ppm (v/v) |
| Sensing Rate | 1–5,000 particles/sec |
| Analysis Time | 10–100 sec (as low as 1 sec) |
| Repeatability | ±1% (n=10, same sample) |
| Reproducibility | ±1.5% (inter-instrument) |
| Electrolyte Compatibility | Aqueous, organic, or solvating organic media |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant software |
| Brand | Micromeritics |
|---|---|
| Origin | United Kingdom |
| Model | FT4 |
| Instrument Type | Multifunctional Powder Flowability Tester |
| Measurable Powder Parameters | Flow Function, Flow Energy, Aeration Energy, Consolidation Energy, Compressibility, Permeability, Wall Friction Angle |
| Maximum Sample Vessel Capacity | 160 mL |
| Minimum Sample Volume | 1 mL (with optional mini shear cell) / 10 mL (standard) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SAS II 5800 |
| Measurement Range | 0.2–75 µm |
| Repeatability | ±1% RSD |
| Porosity Range | 0.2–0.9 |
| Compliance | ASTM B330-12, ASTM C721-14 |
| Display | Integrated Touchscreen Interface |
| Control Software | SAS Control Suite v5.x |
| Dimensions (H×W×L) | 55 × 50 × 38 cm |
| Weight | 28 kg |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SediGraph III Plus |
| Measurement Principle | X-ray sedimentation |
| Measurement Range | 0.1–300 µm |
| Repeatability | < 1% RSD |
| Accuracy | < 1% error vs. NIST-traceable standards |
| Analysis Time | 3–15 minutes per sample |
| Sample Volume | 50 mL dispersion |
| Compliance | ISO 13317-3, ASTM B761, ASTM C28 (Advanced Ceramics) |
| Automation | Unattended analysis of up to 18 samples |
| Optional Integration | MasterTech Auto-sampler for process monitoring and cloud data export |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | AEROTRAC II |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.5–2,000 µm |
| Repeatability | ≤1% |
| Measurement Time | 10–15 seconds |
| Optical Principle | Static Laser Diffraction with Full-Range Mie Theory Processing |
| Laser Source | Semiconductor Laser |
| Auto-Focusing | Yes |
| Trigger Mode | Automatic Pulse Detection |
| Software Platform | Windows-Compatible Analysis Suite |
| Optional Accessories | PD-10S Dry Spray Module, SC-13 Wet Dispersion Unit, MB-600 Motorized Translation Stage |
| Compliance | Designed for ASTM E799, ISO 13320, and USP <429> alignment |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER 3D |
| Instrument Type | Dynamic |
| Measurement Parameters | Particle size (minimum size, length, mean diameter, etc.) and particle shape (aspect ratio, symmetry, sphericity, convexity, etc., compliant with ISO 9276-6) |
| Measurement Range | 20 µm to 30 mm |
| Frame Rate | Up to 250 fps (3D mode) |
| Camera System | Dual-camera (9 MP ZOOM + 5 MP BASIC) |
| Analysis Time | 2–5 minutes per sample |
| Sample Throughput | High |
| Particle Tracking | 3D trajectory reconstruction with up to 30 images per particle |
| Compliance | ISO 9276-6, ASTM E2457, GLP/GMP-ready with optional 21 CFR Part 11 Audit Trail Manager |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Model | Camsizer M1 |
| Measurement Principle | Static Image Analysis (ISO 13322-1) |
| Measurement Range | 0.5 µm – 1500 µm |
| Camera Resolution | 18.1 MP color sensor |
| Maximum Digital Resolution | 35 nm |
| Objective Lenses | 2.5×, 5×, 10×, 20×, 50× (standard) |
| Sample Stage Positioning Accuracy | <3 µm |
| Repeatability | ±1 µm |
| Dispersion Methods | Dry air dispersion (M-Jet module) and wet dispersion |
| Light Sources | Transmitted light, reflected light, and combined illumination |
| Particle Morphology Parameters | Aspect Ratio, Compactness, Convexity, Roundness |
| Maximum Supported Objectives | 6 |
| Dimensions (Analyzer) | 450 mm × 540 mm × 550 mm |
| Weight (Analyzer) | 45 kg |
| Power Supply | 100–230 V / 50–60 Hz |
| Interface | USB 2.0 (control), USB 3.0 (camera) |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER ONLINE |
| Instrument Type | In-Line / Dynamic |
| Measurement Parameters | Particle size (minimum size, length, equivalent spherical diameter, D10/D50/D90), shape descriptors (aspect ratio, symmetry, sphericity, convexity, roughness, transparency, density-related morphology), compliant with ISO 9276-6 |
| Measurement Range | 22 µm – 35 mm |
| Imaging Speed | Up to 100 high-resolution images per second |
| Output | 32 morphological parameters per analysis cycle |
| Design | Explosion-proof (optional ATEX/IECEx certification), compact footprint, integrated auto-cleaning mechanism, compatible with third-party sample transfer systems (e.g., pneumatic conveyors, screw feeders, belt samplers) |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER ONLINE |
| Application Sector | Pharmaceutical Manufacturing |
| Instrument Type | Dynamic In-line Analyzer |
| Measurement Range | 22 µm – 35 mm |
| Measured Parameters | 32 morphological parameters including dimensional, shape, surface roughness, density, transparency, and true 3D characterization |
| Imaging Speed | Up to 100 high-resolution images per second |
| Design | Compact, explosion-proof (ATEX/IECEx compliant), integrated auto-cleaning mechanism |
| Compliance | Designed for GMP environments with audit-trail-ready data handling |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER ONLINE XL |
| Instrument Type | Dynamic Online Analyzer |
| Measurement Range | 0.8 µm to 8 mm (standard) |
| Measured Parameters | Particle size distribution (D10, D50, D90, length, width, equivalent circular diameter, Feret diameters), particle shape descriptors (aspect ratio, symmetry, sphericity, convexity, solidity, roundness, roughness) per ISO 9276-6 |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER ONLINE XL |
| Application Field | Pharmaceutical Manufacturing |
| Instrument Type | Dynamic Inline Analyzer |
| Measurement Range | 160 µm – 135 mm |
| Measured Parameters | Particle Dimensions, Shape Metrics (e.g., Aspect Ratio, Circularity, Convexity), Surface Roughness, Density Estimation, Transparency Classification, 3D Morphological Reconstruction |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer | RETSCH TECHNOLOGY & JENOPTIK JENA (formerly ZEISS) |
| Model | CAMSIZER P4 |
| Measurement Principle | Dynamic Image Analysis (DIA) |
| Measurement Range | 10 µm – 30 mm |
| Sample Type | Dry, free-flowing powders and granules |
| Dispersion Method | Vibratory dry dispersion |
| Optical System | Dual high-resolution lenses (1.3 MP per channel) |
| Image Acquisition Rate | 60 frames/s |
| Pixel Resolution per Image | >780,000 pixels |
| Compliance | ISO 13322-2, CE, FDA 21 CFR Part 11, GLP/GMP-ready audit trail |
| Dimensions (H×W×D) | 650 × 850 × 350 mm |
| Weight | 40 kg (without PC) |
| Analysis Time | 2–3 min (sample-dependent) |
| Key Output Parameters | Equivalent circular diameter (ECD), Feret diameter, aspect ratio, circularity, convexity, solidity, transparency index, particle count, size distribution (volume-, number-, surface-weighted), shape distribution histograms |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Model | CAMSIZER X2 |
| Measurement Principle | Dynamic Image Analysis (ISO 13322-2) |
| Measurement Range | 0.8 µm to 8 mm (overall) |
| Dual CCD Imaging System | 2 lenses (blue reference lens + red high-magnification lens) |
| Dispersion Modes | Dry (free-fall & pneumatic) and Wet (liquid suspension) |
| Sample Throughput | <20 mg – 500 g per measurement |
| Frame Rate | >300 fps |
| Image Resolution | ~4.2 MPixel per frame |
| Pixel Resolution | 0.8 µm/pixel |
| Measurement Area | ~20 × 20 mm |
| Shape Parameters | Aspect Ratio, Circularity, Convexity, Symmetry, Compactness, Sphericity (per ISO 9276-6) |
| Size Parameters | Equivalent Circle Diameter, Length, Width, Feret Diameter, Minimum Bounding Rectangle, etc. |
| Measurement Time | 1–3 minutes |
| Dimensions (W×H×D) | 850 × 580 × 570 mm |
| Weight (Analyzer Unit) | ~50 kg |
| Operating PC | Integrated quad-core Windows 10 system with dedicated hardware interface card, monitor, keyboard, mouse, and Microtrac’s proprietary evaluation software |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CAMSIZER X2 |
| Application Fields | Pharmaceutical, Chemical, Materials Science, Additive Manufacturing, Battery Materials |
| Instrument Type | Dynamic Imaging Analyzer |
| Number of Lenses | Dual-Lens System (ISO 13322-2 Compliant) |
| Measurement Range | 0.8 µm – 8 mm |
| Sample Dispersion Methods | X-Jet (Compressed Air Jet Disperser), X-Flow (Wet Dispersion with Ultrasonic Agitation), X-Fall (Gravity-Based Free-Fall Dry Dispersion) |
| Optical Resolution | 0.8 µm per pixel (effective particle detection limit) |
| Measured Morphological Parameters | Aspect Ratio, Symmetry, Sphericity, Convexity, Solidity, Circularity, Elongation, Roundness, Compactness, Transparency Index, Density Estimation (via grayscale calibration) |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER XL |
| Application Field | Pharmaceutical |
| Instrument Type | Dynamic |
| Measurement Range | 160 µm – 135 mm |
| Camera Resolution | 2560 × 2048 pixels, up to 62 frames per second at maximum resolution |
| Measured Parameters | Dimensional parameters (15), Shape/Shape Factor parameters (13), Surface Roughness (3), Density, Transparency, and 3D Morphology |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER XL |
| Instrument Type | Dynamic |
| Measurement Range | 160–135,000 µm |
| Measured Parameters | Particle size (minimum size, length, equivalent circular diameter, Feret diameters, etc.), particle shape (aspect ratio, symmetry, sphericity, convexity, solidity, roundness, roughness, etc.) per ISO 9276-6 |
| Imaging Speed | Up to 100 images per second |
| Optical System | Enclosed, maintenance-optimized design |
| Sample Handling | Dry, non-contact, customizable feed modules |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PARTAN 3D |
| Application Sector | Pharmaceutical |
| Instrument Type | Dynamic |
| Measurement Range | 22 µm – 35 mm |
| Camera Resolution | 2560 × 2048 pixels |
| Measured Parameters | Dimensional (length, width, thickness), Shape (13 descriptors), Surface Roughness (3 parameters), Density, Transparency, 3D Morphology |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | NANOTRAC FLEX |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Reproducibility | ≤1% RSD |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C (with optional Peltier module) |
| Detection Method | Dynamic Light Backscattering (180° geometry) with full-range Mie theory-based data inversion |
| Sample Volume | as low as 2 µL |
| Sample Concentration Limit | up to 40 vol.% (non-dilutive measurement) |
| Zeta Potential Range | –3000 mV to +3000 mV (when coupled with STABINO ZETA) |
| Molecular Weight Estimation | via hydrodynamic diameter and Debye plot correlation |
| Optical Architecture | Fixed-focal-length fiber-optic probe with laser amplification detection |
| Data Processing Algorithm | Frequency Power Spectrum (FPS), not conventional Photon Correlation Spectroscopy (PCS) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | NANOTRAC WAVE II |
| Zeta Potential Range | ±200 mV |
| Temperature Operating Range | 0–90 °C (programmable ramp) |
| pH Resolution | 0.1 |
| Temperature Accuracy | ±0.1 °C |
| Particle Size Range | 0.3 nm – 10 µm |
| Concentration Range | 100 ppb – 40 % w/v |
| Detection Angle | 180° (backscatter) |
| Repeatability | ≤1% |
| Theoretical Basis | Full-range Mie theory with non-spherical particle correction factor |
| Compliance | ISO 13321, ISO 13099-2:2012, ISO 22412:2008 |
| Software Compliance | FDA 21 CFR Part 11 (electronic signatures, audit trail, user access control) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | S3500 Series |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Laser Diffraction) | 0.01–2,800 µm |
| Image Analysis Range | 0.75–2,000 µm |
| Repeatability | <1% |
| Measurement Time (Laser Diffraction) | 10–30 s |
| Measurement Time (Dynamic Image Analysis) | ~60 s |
| Light Source | Patented Triple-Solid-State Laser (Laser Diffraction) / High-Intensity Stroboscopic LED (Image Analysis) |
| Detection Angle Range | 0.02°–163° |
| Detector Array | 151 logarithmically spaced silicon photodiodes |
| Image Sensor | 5 MP, 2456 × 2058 resolution, 15 fps (optional high-speed camera available) |
| Software Compliance | Fully compliant with FDA 21 CFR Part 11 (audit trail, electronic signatures, data integrity controls) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | S3500SI |
| Measurement Principle | Laser Diffraction & Dynamic Image Analysis |
| Size Range (Laser Diffraction) | 0.01–2800 µm |
| Size Range (Dynamic Imaging) | 0.75–2000 µm |
| Repeatability | ±0.1% |
| Light Source | Triple Solid-State Red Lasers (635 nm) + High-Intensity Stroboscopic LED |
| Detector Array | 151 Logarithmically Spaced Silicon Photodiodes, Acceptance Angle: 0.02°–163° |
| Imaging Sensor | 5 MP CMOS, Resolution: 2456 × 2058 |
| Analysis Time (LD) | 10–999 s |
| Analysis Time (Imaging) | 60 s per field |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures, Data Integrity Controls |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | STABINO ZETA |
| Zeta Potential Range | ±3000 mV |
| pH Range | 1–14 |
| Operating Temperature Range | 0–90 °C |
| pH Resolution | ±0.1 |
| Temperature Resolution | ±0.1 |
| Measurement Principle | 180° Dynamic Light Scattering and Heterodyne Doppler Electrophoresis |
| Repeatability | ≤1% error |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | SYNC |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction + Dynamic Image Analysis Hybrid System |
| Measurement Range | 0.01–4000 µm |
| Repeatability | <1% |
| Measurement Time | 10–30 s |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JYS-200 |
| Principle | Electromechanical Vibratory Sieving |
| Sieve Diameter | Φ200 mm |
| Max Load Capacity | 8 kg |
| Stackable Sieve Layers | 8 |
| Standard Sieve Diameters | Φ200 / Φ100 / Φ75 mm |
| Particle Size Range | 38 µm – 3 mm |
| Noise Level | ≤50 dB(A) |
| Max Single Batch Feed | 200 g |
| Vibration Amplitude | ≤5 mm |
| Motor Speed | 1420 rpm |
| Power Supply | AC 220 V, 50 Hz |
| Motor Power | 0.125 kW |
| Net Weight | 40 kg |
| Dimensions (L×W×H) | 400 × 300 × 736 mm |