Particle/Powder Analysis Instruments
Filter
Showing 181–210 of 340 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SZ-100 V2 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Characterization System |
| Size Range | 0.3 nm – 10 µm |
| Reproducibility | ±2% |
| Measurement Time | < 2 min |
| Zeta Potential Range | −500 mV to +500 mV |
| Molecular Weight Range | 1,000 – 2×10⁷ Da |
| Detection Angles | 90° and 173° (automatically or manually selectable) |
| Sample Volume | 12 µL – 1,000 µL |
| Measurement Principle for Size | Dynamic Light Scattering (DLS), also known as Photon Correlation Spectroscopy (PCS) |
| Zeta Potential Principle | Laser Doppler Electrophoresis |
| Molecular Weight Determination | Debye Plot Analysis |
| Second Virial Coefficient (A₂) | Yes |
| Integrated Auto-Titrator | Yes (for pH-controlled zeta potential studies) |
| Compliance | NIST-traceable calibration with 100 nm standard particles |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ViewSizer 3000 |
| Pricing | Upon Request |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 10 nm – 15 µm |
| Repeatability | Not Specified |
| Measurement Time | 6 min |
| Brand | INPROCESS-LSP |
|---|---|
| Origin | Netherlands |
| Model | NanoFlowsizer |
| Particle Size Range | 10–1000 nm |
| Size Reproducibility | ±2 nm |
| Temperature Range | −10 to 125 °C |
| Temperature Control Accuracy | ±0.5 °C (−10 to 85 °C), ±2.0 °C (85 to 125 °C) |
| Optical Signal Frequency | 76 Hz |
| Measurement Principle | Spatially Resolved Dynamic Light Scattering (SR-DLS) |
| Sample Concentration Range | Unrestricted |
| Minimum Sample Volume | ≥100 µL |
| Zeta Potential Range | Not applicable (dedicated particle sizing only) |
| Measurement Time | <10 s per acquisition |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Wet-Dispersion Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <1% RSD (D50) |
| Measurement Time | ≤10 seconds per run |
| Dispersing Medium Volume | ≥180 mL (standard), optional 10 mL micro-circulation mode |
| Ultrasonic Power | 100 W with dry-run protection |
| Optical Alignment | Fully automated mechanical–optical dual-axis centering (≤15 s, 0.2 µm step resolution) |
| Detector Channels | 121 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, USP <429>, FDA 21 CFR Part 11 ready (with audit trail, electronic signature, role-based access control) |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Wet-Dispersion Laser Particle Size Analyzer |
| Measurement Range | 0.1–300 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <120 s per run |
| Dispersion Method | Wet dispersion with integrated ultrasonication, stirring, and circulation |
| Laser Source | λ = 639 nm, P > 2 mW |
| Ultrasonic Frequency | 40 kHz, Power: 60 W (adjustable duration) |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL (optional 10 mL micro-cell) |
| Compliance | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Winner311XPPLUS |
| Price Range | USD 14,000–21,500 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–100 µm |
| Repeatability | >99% |
| Measurement Time | 10–120 s |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Winner 318 |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 4.6–2000 µm |
| Repeatability | <1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Optical Principle | Fraunhofer Diffraction |
| Laser Source | LD-pumped solid-state laser, λ = 532 nm, P > 40 mW |
| Detector Channels | 60 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Measurement Zone Length | Adjustable from 1 to 10 m |
| Optical Alignment | 3-axis motorized micrometer stage (±20 mm translation, ±20 mm vertical lift, ±20° rotation) |
| Lens Protection | Dual-air-curtain system |
| Dimensions (L×W×H) | 500 × 254 × 520 mm (main unit) |
| Weight | 45 kg + 23 kg |
| Software | WinPAS v5.x with real-time spatial mapping, multi-scattering correction, and cross-sectional distribution analysis |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | 802 |
| Price Range | USD 14,000–28,000 (FOB) |
| Particle Size Range | 1–10,000 nm |
| Repeatability | ≤1% (D50 of NIST-traceable standard reference material) |
| Temperature Control Range | 5–90 °C |
| Temperature Stability | ±0.1 °C |
| Light Scattering Angle | 90° |
| Detection Method | Dynamic Light Scattering (DLS) |
| Sample Volume | 1–4 mL |
| Sample Concentration Range | 0.1–100 mg/L |
| Laser Source | Adjustable-power 532 nm semiconductor laser (1–40 mW) |
| Detector | Hamamatsu photomultiplier tube (PMT) |
| Correlator | CR256 digital autocorrelator (256 channels, 100 ns–10 ms delay resolution) |
| Measurement Time | <5 minutes per run |
| Compliance | GB/T 19627–2005, GB/T 29022–2012, ISO 13321:1996, ISO 22412:2008 |
| Brand | Labman |
|---|---|
| Origin | Germany |
| Model | TIDAS |
| Measurement Principle | Hegman-type grind gauge imaging analysis |
| Sample Application | Liquid dispersions (paints, inks, coatings, slurries) |
| Plate Range Compatibility | 0–15 µm, 0–25 µm, 0–50 µm, 100 µm, 250 µm (custom plates available) |
| Imaging Resolution | High-definition digital capture |
| Analysis Time | ≤1 s per image |
| Total Cycle Time | ~15 s (including auto-coating) |
| Software Platform | Windows 7/8/10 native |
| Data Output | Histograms, particle size distribution profiles, pass/fail grading per ISO 1524 or ASTM D1316 |
| Compliance Support | Audit-trail ready, GLP/GMP-compatible metadata logging |
| Interface | USB 2.0 |
| System Lifespan | ≥12 years (field-validated) |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1 µm – 360 µm |
| Repeatability | Better than ±0.5% (NIST-traceable latex standard) |
| Optical Principle | Laser Diffraction with Full Mie Scattering Theory |
| Lens Aperture | Ø110 mm Fourier Transform Coated Lens |
| Laser Source | Imported High-Power Fiber-Coupled Semiconductor Laser, 635 nm |
| Detector Array | Uniform Cross-Distributed & Area-Compensated Multi-Axis Photodiode Array |
| Obscuration Range | 3% – 90% |
| Data Acquisition | 16-bit ADC, 200 kps Sampling Rate |
| Power Supply | External DC Adapter (No Internal AC Mains) |
| Brand | LINKOPTIK |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | Nanolink SZ901 |
| Zeta Potential Range | No practical limit |
| Max Conductivity | 270 mS/cm |
| Temperature Operating Range | −15 °C to 120 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | ±0.1 °C |
| Particle Size Range | 0.3 nm – 15 μm |
| Measurement Angles | 12°, 90°, 173° |
| Accuracy (Size) | Better than ±1% (NIST-traceable standards) |
| Repeatability (Size) | Better than ±1% (NIST-traceable standards) |
| Minimum Sample Volume | 3 µL |
| Minimum Concentration | 0.1 mg/mL |
| Laser | 638 nm, 50 mW solid-state diode with integrated TEC stabilization and fiber coupling |
| Detector | High-sensitivity APD with dark count <20 cps |
| Correlator | High-speed digital correlator, dynamic range >10¹¹ |
| Molecular Weight Range | 340 Da – 2 × 10⁷ Da |
| Zeta Applicable Size Range | 1 nm – 120 μm |
| Electrophoretic Mobility Range | 0 to no practical limit |
| Temperature Control Precision | ±0.1 °C |
| Dimensions | 430 mm × 512 mm × 230 mm (L×W×H) |
| Weight | 20 kg |
| Brand | Logan |
|---|---|
| Origin | Tianjin, China |
| Model | KZ-4 |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Compliance Standards | NAS 1638, ISO 4406:1999, GJB 420B–2006, GJB 420A–1996, ROCT 17216 |
| Calibration Standards | ISO 4402, GB/T 18854–2002 (equivalent to ISO 11171:1999) |
| Detection Channels | 8 fixed-size channels |
| Display | OLED screen with membrane keypad interface |
| Housing Material | High-strength aluminum alloy |
| Environmental Rating | Industrial-grade, high-temperature & high-pressure resistant |
| Communication Interfaces | RS485 (standard), optional RS232 / Modbus RTU / 4–20 mA |
| Data Output Modes | Real-time particle count per channel + contamination grade |
| Optional Sensors | Water activity (a<sub>w</sub>) sensor, oil temperature sensor |
| Flow Monitoring | Integrated real-time flow rate measurement |
| Language Support | English / Chinese UI toggle |
| Explosion-Proof Variant | KZ-4F (Exib II BT3 Gb) |
| Software Features | Built-in calibration wizard, user-defined standard loading, audit-ready data logging |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Floc-tester ET 730 / ET 740 / ET 750 |
| Stirring Positions | 4 (ET 730, ET 740) or 6 (ET 750) |
| Stirring Speed Range | 10–300 rpm |
| Timer Range | 0–999 min or 0–99 h (continuous) |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Sample Vessel Compatibility | 1000–1500 mL beakers (ET 740/ET 750) |
| Illuminated Rear Panel | Yes |
| Application Environment | Laboratory (ET 740/ET 750) and Field-Deployable (ET 730) |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | LS Spectrometer |
| Particle Size Range | 0.15 nm – 5 µm |
| Temperature Control | Up to 90 °C |
| Measurement Principles | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS), upgradable to 3D and Modulated 3D techniques |
| Sample Volume | 50 µL – 4 mL |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | LSI Correlator |
| Application Scope | Dynamic Light Scattering (DLS), Fluorescence Correlation Spectroscopy (FCS), Diffusing Wave Spectroscopy (DWS), Diffuse Correlation Spectroscopy (DCS) |
| Correlation Algorithm | Multi-tau and Linear-tau Digital Correlation |
| Time Delay Range | 12.5 ns – 3436 s (13 decades) |
| Number of Channels | 322 total (296 detection + 26 auxiliary) |
| Fastest Configurable Initial Delay | 12.5 ns, 200 ns, 400 ns, 800 ns, or 3200 ns |
| Normalization Modes | Symmetric and Compensation Normalization |
| Max. Count Rate | 20 Mcps (at 52 ms integration) |
| Interface | USB 2.0 and Gigabit Ethernet |
| OS Support | Windows & Linux |
| Firmware Upgradability | Field-upgradable via host software |
| Power Supply | External stabilized DC source |
| Dimensions | 120 × 120 × 53.6 mm (aluminum housing) |
| Detector Protection | Real-time gated output with user-defined count-rate threshold |
| Synchronization | Dedicated clock output for hardware timing alignment |
| Software Integration | Native APIs for MATLAB, LabVIEW, Python |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | NanoLab 3D |
| Particle Size Range | 0.3 nm – 10 µm |
| Sample Volume | as low as 4 µL (optional) |
| Temperature Control Range | 4 °C – 85 °C |
| Viscosity Measurement Range | 0.01 cP – >1000 cP |
| Compliance | ISO 22412 (at ≤23 °C ambient) |
| Technique | Modulated 3D Cross-Correlation DLS |
| Brand | LUM GmbH |
|---|---|
| Origin | Germany |
| Model | LUMiSizer 65X |
| Measurement Principle | STEP-Technology (Spatial and Temporal Extinction Profiles) |
| Sample Throughput | 12 positions simultaneously |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Particle Size Range (ISO 13318-2) | 20 nm – 100 µm |
| Stability & Sedimentation Velocity Range | 10 nm – 1000 µm |
| Concentration Range | 0.00015 % – 90 % w/w |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Acceleration Force | 6 × g to 2300 × g |
| Optical Wavelength Options | 470 nm (blue) and 865 nm (NIR) |
| Sample Volume | 0.05 – 2.0 mL |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (via SEPView software audit trail), GLP/GMP-ready |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFuge® |
| Measurement Principle | Spatially Resolved Extinction Profile Analysis under Controlled Centrifugal Force |
| Sample Throughput | Up to 8 samples per run |
| Rotor Speed Range | 0–4,000 rpm (variable, programmable) |
| Detection Method | Polydisperse near-infrared (NIR) light transmission at 870 nm |
| Spatial Resolution | 10 µm per data point across 5 cm sample path |
| Data Acquisition Frequency | Up to 1 scan/s (adjustable) |
| Temperature Control | 5–40 °C (±0.5 °C) |
| Sample Volume per Cell | 0.1–2.0 mL |
| Compliance | ASTM D7713-19 (Standard Practice for Stability Evaluation of Dispersions by Centrifugation), ISO 13321 (Particle Size Analysis – Photon Correlation Spectroscopy), GLP-ready with audit trail and user access control |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiReader PSA |
| Measurement Principle | STEP Technology™ (Spatial and Temporal Extinction Profiles) |
| Acceleration Method | Gravimetric Tilt Enhancement (0°–30° tilt, up to 10× g-equivalent separation rate) |
| Detection | Multi-wavelength LED array (470 nm, 525 nm, 625 nm, 850 nm) |
| Optical Sensors | >9,000 high-resolution photodiodes per detector |
| Sample Volume | 0.5–4.0 mL |
| Concentration Range | 0.00015–75 wt% |
| Particle Size Range (PSD) | 500 nm–300 µm (ISO 13317 compliant) |
| Stability Assessment Range | 200 nm–2000 µm |
| Viscosity Range | 0.8–10⁸ mPa·s |
| Density Range | up to 22 g/cm³ |
| Temperature Control | Ambient +3°C to 60°C (±1 K) |
| Tilt Angles | 0°, 5°, 10°, 15°, 20°, 25°, 30° |
| Minimum Acquisition Interval | 0.5 s |
| Data Output | Extinction profiles (E(z,t)), velocity distribution Qᵥ(v), intensity-weighted PSD Qᵢₙₜ(x), volume-weighted PSD Q₃(x) |
| Compliance | ISO/TR 13097, ISO 13317, ASTM D7827, FDA 21 CFR Part 11 (audit trail & electronic signature ready), GLP/GMP-ready architecture |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiSizer |
| Price Range | USD 68,000 – 95,000 |
| Sample Capacity | 12 positions |
| Measurement Principle | Spatially Resolved Extinction Profile Analysis (STEP Technology) |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Sample Volume per Cell | 0.05 mL to 2.0 mL |
| Concentration Range | 0.00015 wt% to 90 wt% |
| Viscosity Range | 0.8 mPa·s to 10⁸ mPa·s |
| Particle Size Range (Stability Mode) | 10 nm to 1000 μm |
| Particle Size Range (ISO 13318-2 Compliant Mode) | 20 nm to 100 μm |
| Density Range | up to 22 g/cm³ |
| Acceleration Range | 6×g to 2300×g |
| Optical Wavelengths | Multi-wavelength source (e.g., 870 nm, optionally 470 nm and/or 650 nm) |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (audit trail, electronic signature, user access control), GLP/GMP-ready |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiSizer |
| Price Range | USD 92,000 – 131,500 (converted at ~¥7.6/USD) |
| Sample Capacity | 12 positions |
| Temperature Control | 4 °C to 60 °C (±1 K) |
| Acceleration Range | 6×g to 2300×g |
| Particle Size Range (by STEP-Technology) | 20 nm – 100 μm (stability & sedimentation velocity) |
| Concentration Range | 0.00015 wt% – 90 wt% |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Optical System | Multi-wavelength transmission scanning (650 nm, optional 470 nm & 870 nm) |
| Measurement Principle | Spatial and temporal extinction profiling (STEP-Technology) |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (software audit trail enabled), GLP-ready |
| Sample Volume | 0.05 mL – 2.0 mL |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFuge |
| Centrifugal Acceleration | up to 1200 × g |
| Sample Capacity | 8 positions |
| Temperature Control Range | 4–60 °C (in three programmable zones) |
| Sample Volume | 0.1–2 mL |
| Particle Size Range | 0.05–1000 µm |
| Concentration Range | 1–90 vol% |
| Viscosity Range | 0.8–10⁸ mPa·s |
| Density Range | 0.01–10 g/cm³ |
| Separation Velocity Resolution | 0.01–1000 µm/s |
| Compliance | ISO 13318-2 |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiReader® PSA |
| Measurement Principle | Spatially Resolved Transmission Analysis (SRTA) with Multi-Wavelength Optical Detection |
| Compliance | Designed for GLP/GMP environments |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiSizer |
| Measurement Principle | Spatial-Temporal Extinction Profiling (STEP) Technology |
| Sample Capacity | 12 positions |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Particle Size Range (Stability & Distribution) | 10 nm – 1000 μm |
| Concentration Range | 0.00015 % – 90 % w/w |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Optical Wavelengths | Multi-wavelength LED sources |
| Sample Volume per Cell | 0.05 – 2.0 mL |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100/120/230 V, 50/60 Hz |
| Compliance | ISO 13318-2, ISO/TR 13097, FDA 21 CFR Part 11 (via SEPView software), GLP/GMP-ready audit trail |
| Brand | MAS |
|---|---|
| Origin | USA |
| Model | ZetaFinder ZF400 |
| Zeta Potential Range | ±500 mV |
| pH Range | 0–14 |
| Temperature Range | 0–90 °C |
| pH Resolution | ±0.1 |
| Temperature Resolution | ±0.1 °C |
| Accuracy | ±2% |
| Repeatability | ±2% |
| Particle Size Range | 5 nm – 1000 µm |
| Conductivity Range | 0–10 S/m |
| Sample Concentration | 0.1–60 vol% |
| Sample Volume | 30–230 mL |
| Measured Parameters | Particle Size Distribution, Zeta Potential, Isoelectric Point (IEP), Electroacoustic Amplitude (E5A), Conductivity, pH, Temperature, Acoustic Attenuation, Solid Content |
| Brand | MAS |
|---|---|
| Origin | USA |
| Model | ZetaFinder ZF400 |
| Zeta Potential Range | ±500 mV |
| pH Range | 0–14 |
| Temperature Range | 0–90 °C |
| pH Resolution | ±0.1 |
| Temperature Resolution | ±0.1 °C |
| Accuracy | ±2% |
| Repeatability | ±2% |
| Particle Size Range | 1 nm – 30 µm |
| Sample Concentration Range | 0.1–60% w/v |
| Measurement Principle | Electroacoustic Spectroscopy (EAS) & Colloidal Vibration Current (CVI) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Optical Airborne Particle Counter System |
| Model | MET ONE FMS |
| Instrument Category | Optical Particle Counter |
| Compliance | ISO 14644-1, ISO 21501-4, FDA 21 CFR Part 11, EU GMP Annex 1 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyViewer 400 |
| Instrument Type | In-line Dynamic Imaging System |
| Number of Lenses | 1 |
| Field of View | 1100 µm × 800 µm (±50 µm) |
| Image Resolution | 2200 × 1700 pixels |
| Sample Dispersion Method | In-situ liquid-phase flow-through measurement |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EasyViewer100 |
| Application Field | Pharmaceutical |
| Instrument Type | Dynamic |
| Number of Lenses | 1 |
| Measurement Range | 1.5 µm – 1 mm |
| Sample Dispersion Method | In-line liquid-phase measurement |
| Image Resolution | 1.5 µm |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 5390 |
| Principle | Electrical Sensing Zone (Coulter Principle) |
| Size Range | 0.4–1200 µm (20:1 to 30:1 dynamic range per orifice) |
| Concentration Range | 1–1000 ppm (v/v) |
| Sensing Rate | 1–5,000 particles/sec |
| Analysis Time | 10–100 sec (as low as 1 sec) |
| Repeatability | ±1% (n=10, same sample) |
| Reproducibility | ±1.5% (inter-instrument) |
| Electrolyte Compatibility | Aqueous, organic, or solvating organic media |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant software |