Petroleum Distillation Apparatus
Filter
Showing 61–69 of 69 results
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-DR1515A |
| Operating Pressure | Atmospheric |
| Temperature Range | Ambient to 400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–60 °C |
| Distillation Rate | 4–5 mL/min |
| Volume Measurement Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-DR1520AS |
| Test Pressure | Atmospheric (101.3 kPa) |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Range | 0–60 °C |
| Distillation Rate | 2–5 mL/min |
| Volume Measurement Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-DR1520S |
| Operating Pressure | Atmospheric (101.3 kPa) |
| Temperature Range | −2 °C to 400 °C |
| Temperature Accuracy | ±1 °C |
| Cold Bath Temperature Range | 0 °C to 60 °C |
| Volume Measurement Range | 1 mL to 100 mL |
| Volume Resolution | 1 mL |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Model | STARDist micro |
| Sample Volume | 10 mL ± 0.3 mL |
| Analysis Time | < 10 minutes |
| Temperature Range | 0–500 °C |
| Temperature Resolution | 0.1 °C |
| Heating Power | 140 W |
| Power Supply | AC 100–240 V, 50/60 Hz, 300 W |
| Flash Point Prediction | Closed-cup flash point estimation for diesel and kerosene |
| Compliance | ASTM D7345, EN 17306, IP 596 (directly correlated to ASTM D86, ISO 3405, IP 123) |
| Operating System | Windows-based with capacitive touchscreen and stylus support |
| Form Factor | Benchtop, space-optimized design for mobile or constrained laboratories |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VKL70 |
| Pricing | Upon Request |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-1160 |
| Standards Compliance | ASTM D1160, GB/T 9168 |
| Temperature Range | 0–400 °C (0.1 °C resolution) |
| Distillate Rate Control | 2–9 mL/min (adjustable in 0.5 mL/min increments) |
| Vacuum Control Accuracy | ±1% of setpoint |
| Condenser Temp Control | 30–90 °C (electric heating) |
| Cold Trap Cooling | Integrated compressor-based refrigeration |
| Detection Method | Photoelectric detection for initial boiling point (IBP) and liquid level tracking |
| Heating System | Ni-Cr resistance heater (1 kW, 220 V AC) with forced-air cooling |
| Data Interface | RS-232C serial port |
| Power Supply | 220 V AC, 50/60 Hz, 1500 W |
| Dimensions (W×D×H) | 700 × 750 × 580 mm |
| Weight | ~75 kg |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-6536A |
| Standards Compliance | GB/T 6536, ASTM D86, ASTM D850, ASTM D1078, ASTM D2892, ISO 3405, IP 123, JIS K2254 |
| Temperature Range | 10°C to 400°C (display resolution: 0.1°C) |
| Distillate Rate Control | 2–9 mL/min (adjustable in 0.5 mL/min increments) |
| Condenser Temperature Control | 0–80°C (Peltier + electric heating) |
| Receiver Bath Temperature Control | 0°C/4°C to ambient |
| Detection Systems | Photometric meniscus tracking, CRC thermocouple dry-point sensor, Pt100 temperature sensor |
| Heating Source | Ni-Cr tubular heater (220 V, 1 kW) with forced-air cooling |
| Control Interface | Full-color LCD touchscreen with Windows-based GUI |
| Data Output | RS-232C serial port compliant with laboratory network integration |
| Calibration Functions | Automated multi-parameter correction (temperature, bath, ambient, pressure, volume, time) |
| Power Supply | AC 220 V, 50/60 Hz, 1500 W |
| Dimensions & Weight | 400 × 580 × 700 mm (W×D×H), ~40 kg |
| Brand | Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-6536B |
| Standards Compliance | ASTM D86, D850, D1078, D2892 |
| Temperature Range | 10 °C to 400 °C (0.1 °C resolution) |
| Distillate Rate Control | 2–9 mL/min (adjustable in 0.5 mL increments, PID-regulated) |
| Condenser Temp Control | 0–80 °C (Peltier + resistive heating) |
| Receiver Bath Temp Control | 0/4 °C to ambient |
| Detection | Photometric meniscus tracking (half-meniscus), CRC thermocouple dry-point sensor, Pt100 temperature sensing |
| Power Supply | AC 220 V, 50/60 Hz, 1500 W |
| Dimensions | 740 W × 650 D × 680 H mm |
| Weight | ~75 kg |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | ST-1572 |
| Price Range | USD 1,400–4,200 (FOB) |
| Temperature Range | Ambient to 400 °C |
| Temperature Accuracy | ±0.5 °C |
| Condenser Bath Temperature Range | Ambient to 60 °C |
| Distillation Rate | 1–5 mL/min |
| Volume Measurement Range | 0–125 mL |
| Volume Resolution | 0.1 mL |
| Heating Power | 1000 W (continuously adjustable) |
| Total Power Consumption | ≤1700 W |
| Condenser Material | Stainless Steel |
| Distillation Flask | 125 mL borosilicate glass (≥500 °C thermal resistance) |
| Graduated Cylinder Options | 10 mL and 100 mL |
| Cooling Method | Water-cooled |
| Input Voltage | AC 220 V ±10%, 50 Hz ±10% |
| Operating Environment | 5–45 °C, 10–80% RH |