Petroleum Distillation Apparatus
Filter
Showing 1–30 of 69 results
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | VD10 |
| Operating Pressure | Atmospheric |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–65 °C |
| Distillation Rate | 2–10 mL/min |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Diana 700 |
| Test Pressure | Atmospheric (101.3 kPa) |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling Bath Range | 0–80 °C |
| Distillation Rate | 2–12 mL/min |
| Volume Detection Range | 0–103.5 mL |
| Volume Resolution | 0.01 mL |
| Brand | Benteng |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BT-2001 |
| Price Range | USD 7,000–14,000 (FOB) |
| Operating Pressure | Atmospheric |
| Temperature Measurement Range | 0–450 °C |
| Temperature Accuracy | ±0.2 °C |
| Cold Bath Temperature Range | 0–80 °C |
| Distillation Rate | 2–10 mL/min (programmable & auto-regulated) |
| Volume Detection Range | 0–101 mL |
| Volume Resolution | 0.1 mL |
| Atmospheric Pressure Sensing Range | 300–1100 hPa |
| Pressure Accuracy | ±3 hPa |
| Cold Trap Temperature Range | 0–60 °C |
| Cold Trap Control Accuracy | ±0.3 °C |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-6536A |
| Test Pressure | Atmospheric (0.1 MPa nominal) |
| Temperature Control Range | (Ambient + 10)°C to 60°C (adjustable in 0.1°C increments) |
| Temperature Accuracy | ±0.5°C |
| Condensate Volume Measurement | 100 mL graduated cylinder (1 mL graduation) |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Dual-Sample Capability | Yes (independent dual-channel operation) |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-9168A |
| Test Mode | Vacuum (Reduced Pressure) |
| Temperature Range | 30 °C to 80 °C ±3 °C (for condenser cooling bath) |
| Temperature Accuracy | ±0.5 °C |
| Absolute Pressure Control Range | 2, 5, 10, 20, 50 mmHg |
| Pressure Measurement Range | 2.00–170.00 mmHg ±0.01 mmHg |
| Pressure Control Precision | <0.01 mmHg (at residual pressure <7.5 mmHg) |
| Cold Trap Temperature | ≤−40 °C (Peltier-cooled) |
| Heating Power | 0–500 W adjustable |
| Total Power Consumption | ≤1800 W |
| Compliance | GB/T 9168 |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Deasphaltop |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DVV2000 |
| Pricing | Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Standard Compliance | ASTM D86, IP 123, ISO 3405 |
| Model | 1000 Series |
| Configuration | Atmospheric Distillation Only |
| Heating Control | Electronically Adjustable Heating Plate |
| Condenser Type | Water-Cooled Chromium-Plated Copper Tube Assembly |
| Construction Material | Stainless Steel (Heater & Condenser Units) |
| Distillation Flask Options | 100 mL (Type A), 125 mL (Type B), 200 mL (Type C), 250 mL (Type D) |
| Receiver Flask Options | 25 mL (Type A), 100 mL (Type B), 200 mL (Type C) |
| Temperature Measurement | ASTM/IP Certified Thermometers (e.g., ASTM 2C, 3C, 105C–107C) |
| Origin | Switzerland |
|---|---|
| Type | ASTM D86 Compliant Manual Atmospheric Distillation System |
| Model | 1000 Series |
| Configuration | Modular (Heating Unit 990/A + Condensation Unit 990/B) |
| Compliance | ASTM D86, IP 62–88, ISO 3405 |
| Heating Control | Electronically Adjustable Stainless Steel Heating Plate |
| Condenser | Chrome-Plated Copper Tubing with Water-Circulated Jacket |
| Visibility | Front-Mounted Tempered Glass View Window |
| Bottle Capacity Options | 100 mL (Type A), 125 mL (Type B), 200 mL (Type C), 250 mL (Type D) |
| Receiver Volumes | 25 mL (Type A), 100 mL (Type B), 200 mL (Type C) |
| Temperature Measurement | ASTM/IP Calibrated Thermometers (ASTM 2C to 107C / IP 62C to 88C) |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D1160 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Type | Automated Distillation Apparatus |
| Model | 3025 |
| Temperature Range | 0–420 °C |
| Volume Resolution | 0.01 mL |
| Distillation Rate Programmable | 2–15 mL/min |
| Compliance | ASTM D86, D850, D1078, D2892 |
| Receiver Chamber Heating | up to 60 °C |
| Safety Systems | Integrated N₂ fire suppression, optical level detection, real-time diagnostics |
| Software | LIMS-integrated, GLP-compliant data logging, ASTM repeatability/reproducibility calculation |
| Network Capacity | Up to 32 units via Ethernet |
| Power Supply | 230 V, 50/60 Hz, 10 A |
| Dimensions (L×W×H) | 53.3 × 54.6 × 70.5 cm |
| Net Weight | 91 kg |
| Brand | Fland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDR-0871 |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Range | −10 to 80 °C |
| Distillation Rate | 4–5 mL/min |
| Volume Measurement Range | 1–100 mL |
| Volume Resolution | 0.1 mL |
| Heating Power | 2 kW |
| Refrigeration Power | 1 kW |
| Refrigeration Control Accuracy | ±1 °C |
| Steam Temperature Sensor Range | 0–400 °C |
| Furnace Temperature Sensor Range | 0–500 °C |
| Refrigeration Sensor Range | 0–100 °C |
| Brand | Fulande (csfriend) |
|---|---|
| Model | FDR-4571 |
| Origin | Hunan, China |
| Display | LCD screen |
| Distillation Rate | 4–5 mL/min |
| Cold Bath Temperature Range | −10 to +70 °C |
| Heating Temperature Range | Ambient to +350 °C |
| Temperature Resolution | 0.1 °C |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Temperature Sensor | Imported German probe |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 1.5 kW |
| Operating Environment | 0–60 °C, ≤80% RH |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 40.10 |
| Price Range | USD 13,500 – 68,000 |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIDIS ADXpert |
| Test Pressure | Atmospheric (0 kPa gauge) |
| Temperature Range | 0–400 °C (32–752 °F) |
| Temperature Accuracy | ±0.1 °C |
| Distillation Time (Gasoline) | 15 min |
| Sample Volume | 6 mL |
| Residue Measurement | Integrated analytical balance (±0.003 g) |
| Predefined Methods | 10 (ASTM D86 Group 0–4, ASTM D7344, ISO 3045, IP 123) |
| Cleaning Volume per Cycle | 4 mL (acetone) |
| Dimensions (W×H×D) | 200 × 320 × 220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W or 12 V DC (optional vehicle battery) |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniDIS ADXpert |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Range | 0–50 °C |
| Distillation Rate | 0–12 mL/min |
| Volume Detection Range | 0–110 mL |
| Volume Resolution | 6 µL |
| Sample Volume | 6 mL |
| Residue Measurement Accuracy | ±0.003 g |
| Dimensions | 200 × 320 × 220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Optional DC Input | 12 V / 10 A |
| Predefined Methods | 10 (ASTM D86 Groups 0–4) |
| Data Storage Capacity | 75 test results |
| Compliance | ASTM D86, ASTM D7344, ISO 3405, IP 123, DIN 51751 |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniDIS |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | −20 °C to +60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Detection Range | 0.1 mL |
| Volume Resolution | 0.1 mL |
| Sample Volume | 6 mL |
| Residue Measurement Accuracy | ±0.003 g |
| Dimensions (W×H×D) | 200×320×220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Optional DC Input | 12 V/10 A |
| Compliance | ASTM D7344, ASTM D86, ISO 3405, IP 123, DIN 51751 (Groups 0–4) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniVAP VPSH+ Crude Oil Package |
| Application | Crude oil vapor pressure (RVP/TVPR) determination per ASTM D323, D6377, and ISO 3014 |
| Sample Handling | Mobile piston cylinder sampling system with pressurized transfer and mechanical agitation |
| Automation | Fully automated measurement cycle including purge, equilibration, pressure stabilization, and cleaning |
| Compliance | Designed to meet ASTM D6377 (TVPR), ASTM D323 (RVP), ISO 3014, and EN 13016-1 requirements |
| Operating Temperature | 37.8 °C (100 °F) controlled bath |
| Pressure Range | 0–200 kPa (0–29 psi) absolute |
| Resolution | 0.1 kPa |
| Repeatability | ≤0.5 kPa (per ASTM D6377) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | K11459 |
| Test Pressure Range | Up to 100 psi (689 kPa) |
| Temperature Control Accuracy | ±0.1°C |
| Bath Capacity | 51.9 L (13.7 US gal) |
| Power Supply | 220–240 V, 50/60 Hz, Single Phase, 9.4 A |
| Dimensions (W×D×H) | 38.1 × 38.1 × 91.5 cm |
| Weight | Not specified |
| Sample Compatibility | Gasoline, volatile crude oil, LPG, and other light petroleum distillates |
| Compliance | ASTM D323, D1267 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | K3018 |
| Pricing | Upon Request |
| Temperature Range | 0–420 °C |
| Volume Resolution | 0.01 mL |
| Distillation Rate Programmable | 2–15 mL/min |
| Compliance | ASTM D86, D850, D1078, ISO 3405, DIN 51751, IP 123 |
| Receiver Heating | Up to 60 °C |
| Safety Systems | Integrated optical level detection, automatic fire suppression (manual override), continuous self-diagnosis |
| Power Supply | 230 V, 50/60 Hz, 10 A |
| Dimensions (L×W×H) | 53.3 × 54.6 × 70.5 cm |
| Net Weight | 91 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K45704-TS |
| Test Pressure | Atmospheric |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | −5–60 °C |
| Distillation Rate | 2–15 mL/min |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.01 mL |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K87170 |
| Price Range | USD 14,000–70,000 (est.) |
| Distillation Mode | Vacuum (Reduced-Pressure) |
| Condenser Temperature Range | Ambient +5°C to 150°C |
| Distillation Temperature Range | Ambient to 400°C |
| Vacuum Range | 1.0–50 mmHg (0.13–6.7 kPa) |
| Electrical Supply | 120 or 220/240 VAC, 50/60 Hz |
| Dimensions | 91.5 × 94 × 53 cm |
| Weight | 91 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MICROTOP T |
| Pricing | Available Upon Request |
| Compliance | ASTM D2892 (Standard), Optional ASTM D1160 & D5236 |
| Operating Pressure Range | 10–1000 Torr |
| Distillation Flask Volumes | 100 / 200 / 500 / 1000 mL |
| Column Type | Wiped-film Distillation Column |
| Column Internal Diameters | 18 mm / 25 mm |
| Fraction Collection | 10 Positions (10 mL or 25 mL Vials) |
| Temperature Reporting | True Boiling Point (°C) |
| Output Units | Absolute Volume (mL), % Volume (%V) |
| Maximum Final Boiling Point | Up to 400 °C AET (Atmospheric Equivalent Temperature) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MINITOP COMBI |
| Price | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MINITOP T |
| Pricing | Upon Request |
| Compliance | ASTM D2892 (standard), ASTM D1160 & D5236 (optional) |
| Operating Pressure Range | Atmospheric, 100 mmHg, 2 mmHg (standard), down to 0.5 mmHg (vacuum limit) |
| Distillation Vessel Capacities | 3–100 L (selectable) |
| Effective Distillation Volume | 2–70 L (model-dependent) |
| Column Diameter Options | 25, 36, 50, SS80, SS100 mm |
| Fraction Collection | Up to 20 open-air funnel positions + cryogenic Dewar collection for light ends |
| Output Data | Temperature (°C), absolute volume (mL), % volume recovery (%V) |
| Typical Run Duration | ≥10 hours (sample-dependent, especially for thermally sensitive crudes) |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | 50L Reactive Distillation System |
| Configuration | Integrated vacuum-rated reactor vessel, packed/tray distillation column, reflux separator, fraction receivers, programmable temperature & vacuum control unit, corrosion-resistant fluid handling system |
| Compliance | Designed per DIN EN ISO 9001 manufacturing standards |
| Control Architecture | PLC-based with HMI touchscreen interface and Ethernet-enabled data logging |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Normag |
| Pricing | Upon Request |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | DSV80 |
| Operating Pressure Range | 760 mbar to 10⁻³ mbar |
| Max. Heating Temperature | 250 °C |
| Feed Rate | 0.3–1 kg/h |
| Evaporator Type | Thin-Film & Falling-Film Configurable |
| Vacuum Compatibility | High-vacuum (≤10⁻³ mbar) |
| Application Scope | Thermally labile, high-viscosity, and heat-sensitive compounds |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | Normag Micro SBC-100 |
| Theoretical Plates (at 1 atm, total reflux) | 50 |
| Effective Column Height | 100 cm |
| Column Inner Diameter | DN6 (≈6 mm) |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | Normag |
| Operating Pressure | Atmospheric and Vacuum (up to 0.1 mbar) |
| Temperature Range | Up to 200 °C |
| Reflux Ratio Control | Manual and Automated |
| Condensate Flow Monitoring | Yes, with automatic shutoff safety interlock |
| Feed/Collection | Continuous inlet and outlet |
| Construction Materials | Borosilicate glass (DIN ISO 3585) and PTFE-sealed piston valves |
| Joint Standards | NS-ground, spherical ground, and flange connections |
| Safety Certification | Non-explosion-proof (suitable for standard laboratory environments per EN 61000-6-3 and EN 61000-6-4) |