Petroleum Distillation Apparatus
Filter
Showing 31–60 of 66 results
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Normag |
| Pricing | Available Upon Request |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Normag |
| Pricing | Upon Request |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | STARDist |
| Operating Pressure | Atmospheric |
| Temperature Range | Ambient to 450 °C |
| Temperature Accuracy | ±0.1 °C |
| Condenser Temperature Range | 0–65 °C |
| Recovery Chamber Temperature Range | 0–45 °C |
| Distillation Rate | 2–11 mL/min |
| Volume Detection Range | 0–105% (v/v) |
| Volume Resolution | 0.01 mL |
| Volume Accuracy | ±0.01 mL |
| Residue Measurement | Automatic or Manual |
| Barometric Range | 70–110 kPa (0.1 kPa resolution) |
| Safety System | Integrated Flame Detection with Nitrogen-Actuated Extinguishing |
| Data Interface | Ethernet (LIMS-compatible) |
| Dimensions | 40 × 40 × 63 cm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 1.2 kW |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | BOCLE D5001 |
| Standard Compliance | ASTM D5001 |
| Test Duration | 30 min |
| Load | Fixed Ball Load (Standardized per ASTM D5001) |
| Sample Volume | 50 mL |
| Temperature Control | Precision Thermostatic Bath |
| Humidity & Airflow Control | Integrated Environmental Regulation System |
| Measurement Method | Optical Microscopy of Wear Scar Dimensions (Major & Minor Axes) |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 100CC |
| Compliance | ASTM D2892, ASTM D5236 |
| Control System | Windows-based PC software with real-time process visualization |
| Vacuum Control | Auto-adjusted residual pressure (100, 50, 10, 2 Torr) with manual override |
| Safety Features | Overtemperature shutdown, nitrogen purge activation, audible/visual alarms |
| Fraction Collection | 20-position airtight fraction collector with automated cooling, weighing, logging, and cleaning |
| Interface | Ground-glass joints with elastomeric seals — grease-free vacuum integrity |
| Distillation Modes | Integrated atmospheric-to-vacuum transition with automatic gap cooling |
| Data Output | Excel-native reporting, TBP curve generation, AET temperature conversion |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 104 / PD 107 |
| Construction | Full Borosilicate Glass (Duran®-grade) |
| Distillation Mode | Batch, Vacuum-to-Atmospheric |
| Theoretical Plates | Up to 90 |
| Minimum Sample Volume | 1 mL |
| Column Type | Concentric-Tube Precision Fractionating Column |
| Vessel Options | 0.05–20 L (Glass or SS) |
| Heating Options | Oil Bath or Electric Heating Mantle |
| Compliance | ASTM D2892, D5236, ISO 9198, IP 123 |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 105 |
| Application Domain | Petroleum & Petrochemical R&D, Fine Chemical Synthesis, High-Purity Separation |
| Operating Pressure Range | Atmospheric to Vacuum (≤ 0.1 mbar) |
| Temperature Control Method | Programmable Oil Bath with PID Regulation |
| Reflux Ratio Control | Adjustable via Motorized Reflux Divider |
| Fraction Collection Modes | Temperature-Triggered, Volume-Triggered, or Time-Triggered |
| Receiver Options | 6-, 9-, or 18-position Automated Fraction Collector with Overflow Protection |
| Software Platform | Windows-Based Control Suite with Real-Time Parameter Logging and Curve Visualization |
| Compliance Framework | Designed to Support ASTM D2892 (True Boiling Point Distillation), ASTM D5236 (Extended True Boiling Point), and ISO 3405 |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 200CC |
| Standard Compliance | ASTM D5236 |
| Control System | Windows-based PC-controlled automation |
| Collection Capacity | 12 fraction receivers with IR heating and level tracking |
| Safety Features | Overtemperature shutdown, nitrogen purge activation, user-definable alarm thresholds |
| Distillation Mode | Vacuum batch distillation with automatic AET conversion and cut-point assignment |
| Material Construction | High-purity borosilicate glass (DIN/ISO 3585), ground-glass joints with elastomeric seals (no vacuum grease required) |
| Thermal Management | Adaptive heating power modulation and dynamic coolant temperature control |
| Data Output | Native Excel export (.xlsx), real-time curve visualization (volume % vs. AET °C), GLP-compliant audit trail |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 400CC |
| Standards Compliance | ASTM D2892 & ASTM D5236 |
| Distillation Capacity | 6 L (standard), optional 2–20 L |
| Max Operating Temperature | 420 °C (AET) |
| Pressure Range | 1–760 mmHg |
| Control System | Windows-based PC automation with real-time monitoring and safety interlocks |
| Safety Features | Overtemperature shutdown, vacuum overpressure protection, power-fail emergency cooling, level/leak detection, automatic condenser and pot cooldown |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD1120CC |
| Standard Compliance | ASTM D1120, SAE J1704 |
| Automation Level | Fully Automated |
| Test Duration | 8–15 min per sample |
| Output | Permanent thermal print + network-enabled PDF export |
| Regulatory Context | Designed for GLP-compliant laboratories |
| Application Scope | Engine coolant and brake fluid equilibrium boiling point (EBP) determination |
| Brand | PILODIST |
|---|---|
| Origin | Germany |
| Model | PD300CC |
| Max. Distillation Temperature | 400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–25 °C |
| Distillation Rate | 180–360 mL/h |
| Volume Detection Range | 1–200 mL |
| Volume Resolution | 0.1 mL |
| Compliance | ASTM D1160 |
| Control Interface | 15.6″ IP65-rated touchscreen with integrated thermal printer |
| Data Export Formats | PDF, XLS, CSV, TXT |
| Safety | Dual independent heating safety circuits, auto-termination on AET limit, bath temperature limit, flask temperature limit, distillate volume limit, pressure drop, or flask fracture detection |
| Optional Accessory | 4-position automated fraction collector |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | QUICKDIST 500 CC, QUICKDIST 500M |
| Operating Temperature (Flask) | Up to 350°C |
| Final Boiling Point (AET) | Up to 420°C |
| Operating Pressure | Atmospheric to <1 mbar (vacuum) |
| Theoretical Plates | Up to 60 |
| Flask Volumes | 100 mL, 500 mL, 1 L, 2 L |
| Feed Capacity | Up to 60% of flask volume |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | SP200 |
| Vacuum Range | 1–0.001 mbar |
| Temperature Control Accuracy | ±0.01 °C |
| Construction Options | All-Glass or Glass-Metal Hybrid |
| Evaporator Type | Double-Jacketed Glass Rotating Film Evaporator |
| Condenser | Integrated Helical Coil Internal Condenser |
| Display | LED Digital Readouts for Film Speed, Vacuum Pressure, and Temperature |
| Application Scope | Lab-Scale & Pilot-Scale Molecular Distillation of Thermolabile, High-Boiling, High-Viscosity, or High-Molecular-Weight Organic Compounds |
| Compliance | Designed to Support ASTM D2892 / D5236, ISO 9145, and GLP/GMP-aligned documentation workflows |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | TF 650 |
| Operating Temperature Range | up to 250 °C |
| Operating Pressure Range | 0.1–10 mbar (absolute) |
| Feed Rate | 0.5–10 L/h |
| Evaporation Area | 6.5 dm² |
| Construction Material | High-grade stainless steel (SS 316L standard) |
| Dimensions (W × H × D) | 1.20 × 1.80 × 0.60 m |
| Ultimate Vacuum Capability | ≤0.001 mbar (with compatible vacuum system) |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | VLE 110 |
| Operating Pressure Range | Vacuum to Overpressure (Configurable) |
| Temperature Range | Ambient to 250 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | −20 °C to 100 °C |
| Distillation Rate | 30 drops/min |
| Sample Volume Capacity | 100 mL |
| Volume Resolution | 1 mL |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PLD-0165A |
| Price | USD 1,890 (FOB China) |
| Power Supply | 220 V ±10%, 50 Hz |
| Main Heater Power | 0–1000 W (continuously adjustable) |
| Air Bath Heater Power | 0–400 W |
| Air Bath Temperature Range | Ambient to 100 °C |
| Air Bath Temperature Stability | ≤ ±1 °C |
| Operating Ambient | 5–35 °C, <85% RH |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | PLD-6536B |
| Price | USD 2,350 (FOB China) |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | PLD-6536B |
| Price | USD 2,350 (FOB) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-6536B |
| Heating Power | 0–1200 W (continuously adjustable) |
| Heating Mantle Vertical Adjustment Range | 35 mm |
| Flask Support Plate Aperture Options | Ø37.5 mm and Ø50 mm |
| Condensate Bath Temperature Range (with chiller) | –5 to 80 °C |
| Power Supply | AC 220 V, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-6536B |
| Heating Power | 0–1200 W (continuously adjustable) |
| Heating Mantle Vertical Adjustment Range | 35 mm |
| Flask Support Plate Apertures | Ø37.5 mm and Ø50 mm |
| Condensate Bath Temperature Range | –5 °C to 80 °C (with integrated refrigeration unit) |
| Power Supply | AC 220 V, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-6536C |
| Heating Power | 0–2000 W (continuously adjustable) |
| Heating Chamber Vertical Adjustment Range | 35 mm |
| Flask Support Plate Aperture | Ø37.5 mm |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Display Resolution | 0.1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Refrigeration System | Imported Compressor |
| Condensate Bath Temperature Range | 0–80 °C |
| Compliance | GB/T 6536, ASTM D86, ISO 3405 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 16120-2 |
| Standard Compliance | ASTM D4870, IP 375 (Procedure A), IP 390 (Procedure A), ISO 10307-1 & ISO 10307-2, BS 2000-375, NF M07-063, SH/T 0701, SH/T 0702 |
| Sample Mass | 10 g |
| Flask Capacity | 500 mL |
| Filter Paper Requirement | 2 sheets per test |
| Operating Temperature | 80 °C (sample heating), 100 °C (steam jacket) |
| Vacuum Pressure | 40 kPa |
| Cooling Water | Ambient temperature |
| Dimensions | 40 × 47 × 18 cm |
| Weight | 8 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2001-II |
| Compliance Standards | ASTM D86, GB/T 6536, ISO 3405, IP 123 |
| Temperature Range | 0–400 °C (±0.1 °C) |
| Condenser & Receiving Chamber Temp Control | 0–60 °C (±0.1 °C) |
| Volume Measurement Range | 0–100 mL (0.1 mL resolution) |
| Data Storage Capacity | ≥5,000 test records |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 525 × 590 × 585 mm |
| Net Weight | 84 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP2001-VIB |
| Distillation Configuration | Front-mounted dual-bath dual-condenser |
| Temperature Control Range (Left/Right Bath) | 0–60 °C, ±0.5 °C accuracy |
| Condensate Cylinder Bath Temp | 0 °C to ambient, auto-controlled |
| Distillation Temp Range | Ambient to 400 °C |
| Heater Power | 0–1200 W (continuously adjustable) |
| Display | 7-inch color touchscreen |
| Refrigeration | Imported compressor |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz |
| Total Power Consumption | 2800 W |
| Dimensions (L×H×D) | 664 × 598 × 594 mm |
| Weight | 70 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP2001-VIC |
| Distillation Configuration | Front-mounted dual-bath dual-curved-tube |
| Temperature Range | Ambient to 400 °C |
| Left Bath Temp Control | 0–60 °C, ±0.5 °C accuracy |
| Right Bath Temp Control | 0–60 °C, ±0.5 °C accuracy |
| Condensate Cylinder Bath Temp | 0 °C to ambient, auto-controlled |
| Heating Power | 0–1200 W (continuously adjustable) |
| Supply Voltage | 220 V ±10%, 50 Hz ±1 Hz |
| Total Power Consumption | 2800 W |
| Dimensions (L×H×D) | 664 × 598 × 594 mm |
| Weight | 70 kg |
| Brand | Shenko |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2001-VIII |
| Distillation Method | SH/T 0165 |
| Temperature Range (Distillation) | 0–400 °C (vacuum) |
| Temp. Accuracy | ±0.1 °C |
| Receiving Bath Temp. Range | 0–80 °C |
| Temp. Stability | ±0.2 °C |
| Vacuum Control Range | 2–50 mmHg |
| Vacuum Stability | ±0.2 mmHg |
| Volume Measurement Accuracy | ±0.1 mL |
| Data Storage Capacity | ≥5000 test records |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 780 × 395 × 590 mm |
| Net Weight | 63 kg |
| Brand | SPECTRA INVENT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-DR1500 |
| Price Range | USD 1,400–14,000 (FOB) |
| Temperature Range | Ambient to 360 °C |
| Temperature Accuracy | ±1 °C |
| Brand | SPECTRA INVENT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-DR1505A |
| Pressure Mode | Vacuum (Reduced-Pressure) |
| Temperature Range (Distillation) | Ambient to 400 °C |
| Cold Bath Temperature Range | 5–80 °C |
| Compliance | ASTM D1160, ASTM D2892, ASTM D5236, ISO 3405, GB/T 6536 (Vacuum Mode Adaptation), IP 123 |
| Brand | SPECTRA INVENT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | HX-DR1510A |
| Operating Pressure | Atmospheric |
| Temperature Range | Ambient to 400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–60 °C |
| Distillation Rate | 4–5 mL/min |
| Volume Measurement Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
