Petroleum Product Sulfur Tester
Filter
Showing 31–47 of 47 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PGC5007B |
| Pricing | Available Upon Request |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | PLD-380C |
| Pricing | Upon Request |
| Standard Compliance | GB/T 380 |
| Sample Type | Light petroleum products with Reid Vapor Pressure ≤ 80 kPa |
| Lamp Holder Capacity | 7 parallel sample positions |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Optical Viewing | Transparent acrylic mounting platform for unobstructed visual monitoring |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Micro-Z ULS |
| Detection Principle | Wavelength Dispersive X-ray Fluorescence (WDXRF) |
| Detection Limit | 0.2 ppm |
| Measurement Range | 0–5 wt% |
| Analysis Time | < 300 s |
| Excitation Source Power | 80 W |
| Vacuum Requirement | Yes (gas-free operation) |
| Power Supply | AC 200–240 V, 200 W |
| Operating Environment | 10–40 °C, RH < 80 % |
| Dimensions (W×D×H) | 45 × 41 × 43 cm |
| Weight | 40 kg |
| Compliance Standards | ASTM D2622, GB/T 11140, SH/T 0842 |
| Key | Brand: Rigaku |
|---|---|
| Origin | USA |
| Model | NEX QC |
| Detection Principle | Energy-Dispersive X-Ray Fluorescence (EDXRF) |
| Analyte | Total Sulfur |
| Detection Limit | 5 ppm |
| Measurement Range | 0–10 wt% |
| Sample Volume | 5 mL |
| Analysis Time | 1–999 s (default 300 s) |
| Calibration Method | Compton Scattering C/H Ratio Correction |
| Data Output | USB + Ethernet |
| Environmental Requirements | RH < 85% (no condensation), vibration-free, non-corrosive atmosphere |
| Compliance Standards | ASTM D4294, GB/T 17040 |
| Brand | Rigaku |
|---|---|
| Origin | USA |
| Model | NEX QC+ |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Detection Limit | 2.3 ppm for S |
| Measurement Range | 0–10 wt% S |
| Accuracy (Relative Error) | ±0.0001 |
| Analysis Time | < 3 min (configurable from 1–999 s) |
| Sample Volume | < 5 mL |
| Elemental Range | Na (11) to U (92) |
| Compliance | ASTM D4294, GB/T 17040 |
| Portability | Handheld / Field-Deployable |
| Environmental Operating Range | 15–35 °C, RH < 85% (non-condensing) |
| Data Interface | USB + Ethernet |
| Matrix Correction | Compton Scattering C/H Ratio Normalization |
| Filtration | Multi-layer Composite Primary Beam Filters |
| Safety | Zero hazardous waste generation (no gas, liquid or solid effluent) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200+ |
| X-ray Tube | Pd anode, 50 kV / 4 mA, 200 W |
| Detection Limits | S: 0.1 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, As: 0.2 ppm |
| Detection Range | 0–99.99% |
| Standard Compliance | SH/T 0842 (S), SH/T 0977 (Cl), SH/T 0993 (Si) |
| Optical System | Automated multi-crystal spectrometer with high-resolution crystal selection |
| Sample Handling | 12-position automatic sampler |
| Sample Types | Liquids (gasoline, diesel, naphtha, jet fuel, crude oil, residuum, water, wastewater), solids (catalysts, polypropylene, powders) |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY7200-III |
| Detection Method | High-Temperature Combustion UV Fluorescence |
| Detection Range | 0.2–10,000 mg/kg |
| LOD | 0.2 mg/kg |
| Sample Type | Liquid hydrocarbons (gasoline, diesel, jet fuel, biodiesel, naphtha, ethanol, FAME) |
| Compliance | ASTM D5453, SH/T 0689, GB/T 34100 |
| Furnace Temp | Up to 1075 °C ±25 °C |
| Sample Volume | 5–50 µL |
| Autosampler | 16- or 156-position |
| Gas Control | Triple high-precision mass flow controllers (Ar, O₂-inlet, O₂-pyrolysis) |
| Drying | Imported membrane dryer with auto-backflush |
| Display | 19″ color touchscreen IPC |
| Data Storage | >5,000 test records |
| Power | AC 220 V ±5%, 50 Hz, ≥3 kW |
| Dimensions (H×W×D) | Main unit 525×694×603 mm |
| Weight | 60 kg |
| Operating Environment | 10–30 °C, 20–80% RH |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP2000-II |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Measurement Range | 0.005–5 wt% S |
| Detection Limit | 5 ppm (S) |
| Minimum Quantification Limit | 50 ppm (S) |
| Analysis Time | 30–300 s (default 100 s) |
| X-ray Tube | ≤20 kV, ≤1 mA, ≤10 W |
| Detector | Ultra-thin Beryllium-window Proportional Counter |
| Sample Form | Solid or Liquid (non-destructive, no digestion required) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% at 30 °C |
| Power Supply | 220 V ±20 V, 50 Hz, ≤100 W |
| Dimensions | 285 × 405 × 165 mm (W×D×H) |
| Weight | 10 kg |
| Compliance | GB/T 17040, ASTM D4294 |
| Data Storage | Internal non-volatile memory with power-loss protection |
| Interface | Touchscreen GUI, USB data export |
| Brand | Shengkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY7200-II |
| Detection Method | High-Temperature Combustion UV Fluorescence |
| Detection Range | 0.5–10,000 mg/kg |
| LOD | 0.5 mg/kg |
| Repeatability | ≤ ±0.2 mg/kg (0.5–1.0 mg/kg), ≤ 10% RSD (1.0–10 mg/kg), ≤ 5% RSD (≥10 mg/kg) |
| Sample Type | Liquid (standard) |
| Sample Volume | 5–50 µL |
| Furnace Temp | RT–1075 °C ±25 °C |
| Gas Control | Mass Flow Controllers (Ar: 50–300 mL/min |
| O₂ | 250–500 mL/min |
| Pressure | 0.2 MPa) |
| Analysis Time | 1–3 min |
| Display | 17″ Color Touchscreen IPC |
| Data Storage | >5,000 test records |
| Power | ≥3 kW, AC220V±5%, 50 Hz |
| Dimensions | 595×510×410 mm (W×D×H) |
| Net Weight | 30 kg |
| Compliance | ASTM D5453, SH/T 0689, GB/T 34100 |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SULF UV |
| Detection Target | Total Sulfur |
| Compliance Standards | ASTM D5453, AFNOR M-07-059, ISO 20846, SH/T 0689 |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TS |
| Detection Principle | Combustion Microcoulometry |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur (S) |
| Measurement Range | 0.0020–500 mg absolute sulfur |
| Detection Limit | 0.020 mg/L |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D3229, ASTM D5453, ASTM D7039, ISO 20846, ISO 20884, IP 512, UOP 97, EN ISO 20846, SH/T 0689 |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 1600 |
| Pricing | Available Upon Request |
| Power Supply | 220 V / 50 Hz |
| Operating Temperature | 5–50 °C |
| Storage Temperature | –10–70 °C |
| Sulfur Detection Range | 1 ppb to 100 wt% (user-configurable) |
| Resolution | 1 ppb |
| Accuracy | ±2% of full scale |
| Repeatability | ±1% of full scale |
| Linearity | ±1% of full scale |
| Drift | <1% FS/24 h |
| Temperature Coefficient | 0.01% / °C |
| Analysis Time | <1 s per measurement |
| Interference Resistance | None (non-dispersive UV fluorescence principle) |
| Alarm Outputs | Solid-state 30 mA @ 24 V DC or mechanical relay 5 A @ 220 V AC (NO/NC configurable) |
| Display | 128 × 64 pixel monochrome LCD |
| Analog Output | Standard 4–20 mA (single channel), optional dual 4–20 mA |
| Optional Accessories | Auto-calibration module, heated sample probe & flow regulator, chemiluminescence trigger interface, data logger, process heater & temperature controller, RS-232/RS-485 serial interface, signal junction box |
| Hazardous Area Certification Options | Class I, Div. 2, Groups A–D (1700-series enclosure) |
| Dimensions (W×D×H) | 127 × 30 × 76 cm |
| Weight | 90 kg |
| Brand | TimePower |
|---|---|
| Model | TP683 |
| Measurement Principle | Oxygen Bomb Combustion with Mercury Nitrate or Barium Chloride Titration |
| Compliance | DL/T 433, GB/T 388 |
| Max Operating Pressure | ≥20 MPa |
| Ignition Voltage | 12–24 V DC |
| Repeatability (RSD) | ≤0.0006% (w/w) |
| Ambient Temperature Range | 10–40 °C |
| Relative Humidity | 30–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 300 × 300 × 390 mm |
| Cooling Method | Integrated High-Flow Air Cooling |
| Net Weight | 8.7 kg |
| Brand | XOS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Detection Principle | Wavelength-Dispersive X-ray Fluorescence (WDXRF) |
| Portability | Fixed Installation |
| Analyte | Total Sulfur |
| Measurement Range | 0–3000 ppm (extendable to 10 wt% with optional configuration) |
| Analysis Time | 300 s per measurement |
| Limit of Detection (LOD) | 0.5 ppm |
| Accuracy | ≤ ±10% of reading |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with XLS-26 Liquid Autosampler |
| Detection Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Portability | Benchtop (Non-portable) |
| Analyte Types | Total Sulfur and Total Nitrogen |
| Measurement Range | 20 ppb – 10,000 ppm |
| Analysis Time | 2–6 minutes per sample |
| LOD | 10 ppb (S and N) |
| Accuracy | ±2% of reading |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | Xuxin ST-1545 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Analyte Types | Total Sulfur (S) and Total Nitrogen (N) |
| Detection Principles | UV Fluorescence (S), Chemiluminescence (N) |
| Compliant Standards | SH/T 0657, SH/T 0689, ASTM D4629, ASTM D5453 |
| Sample Forms | Liquids, Solids, Gases (with optional injectors) |
| S Detection Range | 0.2–10,000 mg/L (ppm to wt%) |
| N Detection Range | 0.1–10,000 mg/L (ppm to wt%) |
| S LOD | 0.2 mg/L |
| N LOD | 0.1 mg/L |
| Furnace Temp Range | Ambient to 1300 °C |
| Temp Control Accuracy | ±1 °C |
| Gas Requirements | High-purity Ar (≥99.99%), O₂ (≥99.99%) |
| Flow Control Options | Electronic Mass Flow Controllers or Rotameters |
| Data Acquisition | 24-bit USB interface, signal resolution <1 µV |
| Power | 220 V ±10%, 50 Hz, ≤2500 W |
| Operating Environment | 5–45 °C, 10–80% RH |
| Precision (RSD) | 2–5% across 0.2–5000 ppm range depending on injection volume (5–20 µL liquid) |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-1551 |
| Detection Type | Total Mercaptan Sulfur |
| Compliance Standard | GB/T 1792 |
| Measurement Range | 3–100 μg/g (ppm) |
| Potentiometric Range | −1999.5 to +1999.5 mV |
| Basic Error | ±0.1% ±0.5 mV |
| Burette Volume | 10 mL |
| Burette Accuracy | ±0.1% FS |
| Operating Temperature | 5–45 °C |
| Relative Humidity | 10–80% RH |
| Power Supply | 220 V ±10%, 50 Hz |
| Software Interface | Windows-based workstation with bilingual (Chinese/English) display option |
| Automation Features | Auto-rinsing, auto-reagent replenishment, fixed-volume dispensing, automatic endpoint detection, false-endpoint filtering, manual endpoint override, real-time titration curve plotting, data storage & thermal printing |