Petroleum Specialized Analytical Instruments
Filter
Showing 121–150 of 451 results
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC OIL |
| Product Type | Portable Instrument |
| Detection Parameters | Oxidation, Nitration, Sulfation, Ester Degradation, Phosphorylation, Anti-wear Additives, Antioxidants, Water, Ethylene Glycol, Gasoline, Diesel, TAN, TBN, Viscosity (40 °C & 100 °C) |
| Compliance | ASTM E2412, ASTM D7412, D7414, D7415, D7418, D7624, JOAP, DIN 51452, DIN 51453 |
| Sample Volume | 10 mL |
| Spectral Range | 450–7000 cm⁻¹ |
| Data Points | 16,384 |
| Measurement Time | 60 s |
| Display | 7″ Color Touchscreen |
| Power Supply | 85–264 V AC / 12 V DC (7 A) |
| Dimensions | 22 × 32 × 28 cm |
| Weight | 8 kg |
| Interfaces | 5× USB, 1× Ethernet, 1× RS232, LIMS-ready |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | PYNN ERASPEC |
| Sample Volume | 10 mL |
| Measurement Time | 1 min |
| Spectral Range | 4000–400 cm⁻¹ |
| Spectral Resolution | 3000 data points per scan |
| Density Accuracy | ±0.0001 g/cm³ (integrated Anton Paar density module) |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Power Option | 12 V / 4 A |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Connectivity | 3× USB, 1× Ethernet, 1× RS232, LIMS interface |
| Data Storage | ≥2000 test records |
| Display | 6.5″ color touchscreen (Chinese UI) |
| Compliance | ASTM D1655, ASTM D7462, ASTM D7845, ISO 13739, IP 359, DEF STAN 91-91 |
| Brand | ERALYTICS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | ERAVAP |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | −20–120 °C |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAVAP Online |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAVISC X |
| Standards Compliance | ASTM D445, ASTM D7042, ASTM D4052, ASTM D5002, ISO 3104, ISO 23581, ISO 12185, ISO 2909, ASTM D2270, NB/SH/T 0870, SH/T 0604, SN/T 3518 |
| Viscosity Range | 1–1000 mm²/s |
| Density Range | 0–3 g/cm³ |
| Temperature Range (Viscosity) | 15–100 °C |
| Temperature Range (Density) | 0–100 °C |
| Repeatability | Equivalent to ASTM D445 & D7042 (viscosity), ±0.00001 g/cm³ (density) |
| Resolution | 0.01 mm²/s (viscosity), 0.00001 g/cm³ (density) |
| Temp. Accuracy | ±0.02 °C |
| Measurement Time | 60 s (viscosity), 15 s (density, post-equilibration) |
| Sample Volume | 3 mL |
| FillingProof™ Bubble Detection | Yes |
| Integrated Drying Pump | Yes |
| Data Storage Capacity | >100,000 test records |
| Interfaces | Ethernet, 4× USB (front/rear), RS-232 |
| Display | 8.4″ industrial-grade color touchscreen |
| Power | 85–264 V AC, 47–463 Hz, max. 150 W |
| Dimensions | 15.5 × 26 × 28 cm |
| Weight | 8 kg |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 000-001-305 |
| Test Method Compliance | ASTM D2670, D2625, D3233, D5620 |
| Load Range | 200–3000 lbf (±2% FS) |
| Rotational Speed | 290 ± 10 rpm |
| Torque Measurement | 0–100 in-lb (±2% FS) |
| Wear Resolution | 0.001 inch (0.025 mm) per 14.4 ratchet clicks |
| Operating Temperature | Ambient to 100 °C |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 001-001-331 |
| Test Type | Friction and Wear |
| Load Capacity (Standard) | 805 lbf |
| Load Capacity (Optional) | 1300 lbf |
| Speed Range | Programmable RPM Control |
| Temperature Range (Standard Chamber) | Ambient to 200 °C |
| Temperature Range (Pressurized Chamber, Optional) | Ambient to 250 °C |
| Sub-ambient Testing | Available with External Chiller |
| Friction Force Measurement Range (Standard) | 0–250 lbf |
| Friction Force Measurement Range (Optional Low-Load Sensor) | 0–25 lbf |
| Compliant Standards | ASTM D2714, D2981, D3704, D2509, D2782, G77 |
| Test Geometries | Block-on-Ring, Conforming Block-on-Ring, Timken Canted Cylinder, Chip-on-Ring, Ball-on-Ring |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 006‐001‐330 |
| Testing Type | Friction and Wear |
| Compliance | ASTM D3702, D2266, D4172, D5183, G99 |
| Speed Range | 30–3600 rpm (standard), 0.01–10,000 rpm (with optional gear reducer) |
| Load Range | 1–160 lbf (2:1 lever), 20–800 lbf (10:1 lever) |
| Temperature Range | Ambient to 150°C (standard), 30–200°C (with optional heating/cooling modules) |
| Control | Computer-controlled servo motor, pneumatic auto-loading (programmable), real-time torque & displacement monitoring |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 016-001-002 |
| Test Method Compliance | ASTM D3336, SH/T 0428 |
| Maximum Rotational Speed | 20,000 rpm (light-load condition) |
| Axial Load Capacity | 15 lbs (mechanically applied) |
| Heating Chamber Max Temperature | 371 °C |
| Torque Measurement | Digital display with high/low torque shutdown threshold |
| Drive Motor | Dual 1 HP, single-phase AC motors with thermal protection |
| Timing Control | Digital on/off elapsed-time counter |
| Standard Shaft | CRC-type shaft |
| Application Focus | Grease-lubricated ball bearing life evaluation under accelerated thermal–mechanical stress |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 081-001-005 |
| Test Principle | Oscillating Ball-on-Cylinder Tribometry |
| Applied Load | 2450 N (550 lbf) |
| Test Duration | 22 h |
| Oscillation Frequency | 30.0 Hz (1800 cpm) |
| Compliance Standards | ASTM D4170, SH/T 0716 |
| Optional Feature | Load Uniformity Adjustment System |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 089-001-001 |
| Testing Mode | Wear, Extreme Pressure (EP), and KRL Rolling Fatigue |
| Speed Range | 1–2500 rpm |
| Load Range | 1–1000 kg (standard) |
| optional low-load system | 0–150 ±0.2 kg |
| Compliance | ASTM D2266, D4172, D5183, D2596, D2783 |
| Safety | Interlocked pneumatic loading enclosure |
| Control | Touchscreen interface with programmable cycle counter and elapsed time timer |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 450-001-002 |
| Heating Tube Temperature Range | 300–450 °C |
| Temperature Control Accuracy | ±2 °C |
| Flow Rate Range | 0.55–10.0 mL/min |
| Pressure Range | 0–200 psi |
| Test Duration | 2.5–500 hours |
| Sample Reservoir Temperature | 100–210 °C |
| Sample Volume | 100 mL–1 L |
| Compliance | SAE ARP 5996B, SAE AS5780 |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | FAL400 |
| Compliance | ASTM D3241, IP 323, GB/T 9169 |
| Heating Tube Certification | ASTM D3241 Table 2 Note c, IP 323 Table A.1 |
| Automation | Fully automated air purge (1.5 L/min), pre-test pump priming (60 s), flow verification at start/end |
| Pump System | Dual HPLC-grade precision pumps, pulse-free flow delivery |
| Control System | Embedded microprocessor (non-Windows), corrosion-resistant color touchscreen |
| Safety | Interlocked safety shield with real-time alarm |
| Filtration | Integrated activated carbon fume scrubber |
| Optional Accessory | FAL430 Deposit Rating Ellipsometer (ellipsometric thickness & 3D topography measurement) |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 002‐001‐003 |
| Testing Principle | Timken EP Test (ASTM D2509, ASTM D2782, SH/T 0203) |
| Maximum Applied Load | 92,300 psi (on 0.022 in. wide Timken test block) |
| Rotational Speed | 800 rpm ± 5 rpm (adjustable up to 850 rpm) |
| Test Duration | 10 min ± 15 s |
| Temperature Control Range | Ambient to 120 °C (digital PID controller with fluid circulation system) |
| Oil Reservoir Capacity | 3 L (heated, pumped, valve-controlled |
| Grease Auto-Feeder Rate | 45 ± 9 g/min |
| Drive Motor | 2 HP, unidirectional, with RPM display |
| Load Application | Static load via 10:1 lever arm |
| Sample Types | Liquid lubricants and greases |
| Compliance | ASTM D2509, ASTM D2782, SH/T 0203 |
| Brand | Ayalytical |
|---|---|
| Model | FeDDI |
| Origin | USA |
| Type | Automated Image-Based Corrosion Quantification Instrument |
| Compliance | ASTM D665, GB/T 11143, NACE TM-0172 |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | FYH-M |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58C |
| Product Type | Portable Instrument |
| Detection Modules | XRF Elemental Analysis |
| Test Time per Sample | <10 minutes |
| Sample Volume Required | 12 mL |
| Compliance | ASTM D6595, D7690, D7883, D445 |
| Interface | Touchscreen with Embedded Diagnostic Software |
| Power | Rechargeable Battery |
| Enclosure | Ruggedized Transport Case Integrating All Four Modules |
| Brand | Fland |
|---|---|
| Origin | Hunan, China |
| Model | FDR-0271 |
| Analysis Method | ASTM D323 (Reid Method) |
| Pressure Range | 0–200 kPa (0–29 psi) |
| Temperature Control | 37.8 ± 0.1 °C |
| Sample Capacity | 3 bomb units |
| Power Consumption | 1.5 kW |
| Compliance | ASTM D323, IP 121, GB/T 8017, ISO 3016 |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | SGL 200 |
| Saw Blade Diameter | 200 mm |
| Grinding Wheel Type | Straight-Cup Diamond Wheel, 200 mm Ø, Grit 46 |
| Lapping Plate Diameter | 200 mm |
| Lapping Plate Speed | 150 rpm |
| Motor Speed | 3000 rpm |
| Coolant | Water |
| Sample Capacity | Two 30 × 45 mm (1″ × 1.5″) specimens or one 60 × 45 mm (1″ × 3″) specimen |
| Weight | 50 kg |
| Dimensions (W × D × H) | 640 × 340 × 350 mm |
| Power Supply | 220 V, 50/60 Hz |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Fluorat-02-5M |
| Pricing | Upon Request |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIDIS ADXpert |
| Test Pressure | Atmospheric (0 kPa gauge) |
| Temperature Range | 0–400 °C (32–752 °F) |
| Temperature Accuracy | ±0.1 °C |
| Distillation Time (Gasoline) | 15 min |
| Sample Volume | 6 mL |
| Residue Measurement | Integrated analytical balance (±0.003 g) |
| Predefined Methods | 10 (ASTM D86 Group 0–4, ASTM D7344, ISO 3045, IP 123) |
| Cleaning Volume per Cycle | 4 mL (acetone) |
| Dimensions (W×H×D) | 200 × 320 × 220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W or 12 V DC (optional vehicle battery) |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniDIS ADXpert |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Range | 0–50 °C |
| Distillation Rate | 0–12 mL/min |
| Volume Detection Range | 0–110 mL |
| Volume Resolution | 6 µL |
| Sample Volume | 6 mL |
| Residue Measurement Accuracy | ±0.003 g |
| Dimensions | 200 × 320 × 220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Optional DC Input | 12 V / 10 A |
| Predefined Methods | 10 (ASTM D86 Groups 0–4) |
| Data Storage Capacity | 75 test results |
| Compliance | ASTM D86, ASTM D7344, ISO 3405, IP 123, DIN 51751 |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniDIS |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | −20 °C to +60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Detection Range | 0.1 mL |
| Volume Resolution | 0.1 mL |
| Sample Volume | 6 mL |
| Residue Measurement Accuracy | ±0.003 g |
| Dimensions (W×H×D) | 200×320×220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Optional DC Input | 12 V/10 A |
| Compliance | ASTM D7344, ASTM D86, ISO 3405, IP 123, DIN 51751 (Groups 0–4) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniFlash FLA |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Compliant Standards | ASTM D6450 (SH/T 0768) & D7094 |
| Temperature Range | 0 to 200 °C |
| Dimensions (W×H×D) | 312 × 402 × 390 mm |
| Weight | 20 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniFlash FLAH |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Compliant Standards | ASTM D6450 (SH/T 0768) & D7094 |
| Temperature Range | 10 to 400°C |
| Dimensions (W×H×D) | 312 × 402 × 390 mm |
| Weight | 20 kg |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FP Vision |
| Detection Method | Closed-Cup (ASTM D6450/D7094) |
| Temperature Range | 0–120 °C (standard), down to –25 °C with external chiller |
| Temp. Stability | ±0.05 °C |
| Sample Volume | 1–2 mL |
| Throughput | Up to 12 samples/hour |
| Interfaces | 4× USB, 2× LAN |
| Power | 100–240 V AC, 50/60 Hz, max. 180 W |
| Dimensions | 253 × 368 × 277 mm |
| Weight | 10.2–11.2 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FP VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D6450 (SH/T 0768) & ASTM D7094 |
| Repeatability | ASTM D6450 ≤ 0.4°C, ASTM D7094 ≤ 0.5°C |
| Reproducibility | ≤ 0.9°C for both methods |
| Ignition Method | Electric Arc |
| Temperature Range | 0–120°C (no external cooling required) |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FPA VISION |
| Detection Method | Closed-Cup (ASTM D93, ISO 2719, IP 34, EN ISO 3679) |
| Compatibility | Fully compatible with MINIFLASH FP VISION and FPH VISION analyzers |
| Sample Capacity | 12 positions |
| Footprint | 0.18 m² |
| Operating Temperature Range | –25 °C to 400 °C |
| Cooling Option | External liquid cooling interface for autosampler chamber |
| Power Supply | Switch-mode power supply (SMPS) |
| Software Platform | VISION Cockpit™ PC software (21 CFR Part 11 compliant audit trail, multi-user role management, networked data synchronization) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIFLASH FPA VISION |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Power Supply | 100–264 VAC, 45–63 Hz, Max. 50 W |
| Dimensions (W×H×D) | 435 × 425 × 415 mm |
| Height with FP(H) VISION mounted | 530 mm |
| Weight | 15.9 kg (turntable: 2.2 kg |
| fully loaded turntable | 4.2 kg) |
| Cooling | External liquid cooling interface |
| Compliance | CE-marked per EN standards for laboratory instruments |
| Software Platform | VISION Platform with Cockpit™ PC software |
| Interface | Dedicated hardware interface to MINIFLASH FP/H VISION analyzers |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINISCAN IR Vision Diesel |
| Portability | Portable |
| Measurement Parameter | Diesel Cetane Number |
| Measurement Range | 20–80 CN |
| Accuracy | ±1 CN |
| Analysis Time | 1 minute |
| Sample Volume | 10 mL |
| Compliance | ASTM D5845, ASTM D6277, EN 238, SH/T 0797, EN 14078, ASTM D7806, GB/T 23801, ASTM E1655, GB/T 29858 |
| Spectral Technology | FTIR with Dual Interferometer and Auto-Mirror Calibration |
| Chemometric Engine | PLS (Partial Least Squares) Multivariate Calibration |
| Database | SGS-Verified Real-Fuel Reference Library |
| Display | 10-inch Industrial Touchscreen |
| Power | 12 V DC Vehicle Adapter Compatible |