| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | A1121 |
| Price Range | USD 7,000 – 14,000 |
| Measurement Range | Ambient to –70 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Display | LCD Touchscreen |
| Printer | Thermal, 36-character Chinese/English output |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions (W×D×H) | 460 × 310 × 480 mm |
| Weight | 21.3 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A1261 |
| Heating Method | Electric Furnace |
| Heating Power | 300 W + 600 W + 1000 W (Triple-Zone) |
| Temperature Control Range | 0–520 °C |
| Temperature Control Accuracy | ±5 °C |
| Total Power Consumption | ≤2000 W |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85 % RH |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Dimensions (W×D×H) | 345 × 345 × 381 mm |
| Net Weight | 22 kg |
| Compliance Standard | SH/T 0170 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | A1460 |
| Product Category | Laboratory Instrument |
| Test Parameter | High-Temperature High-Shear Viscosity (HTHS) |
| Applicable Standards | SH/T 0703, ASTM D5481 |
| Power Supply | 220 V, 50 Hz |
| Temperature Control Method | Aluminum Block Bath |
| Test Temperature | 150 ± 0.1 °C |
| Capillary Inner Diameter | 0.15 mm |
| Capillary Effective Length | 16–18 mm |
| Gas Pressure Range | 0.5–3.5 MPa |
| Number of Capillary Cells | 1 |
| Detection Principle | Pressure-Driven Capillary Flow under Controlled Thermal and Shear Conditions |
| Automation | Fully Automated Timing, Pressure Stabilization Monitoring, HTHS Viscosity Calculation & Reporting |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | A2011 |
| Price | Upon Request |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Sensor | PT100 |
| Temperature Control Range | Ambient to 100 °C (adjustable) |
| Temperature Accuracy | ±1 °C |
| Heating Power (Main) | 600 W |
| Auxiliary Heating Power | 1000 W |
| Timer Range | 1 min to 24 h (programmable) |
| Temperature Display | LED digital |
| Time Display | LED digital |
| Test Positions | 4 independent reaction wells |
| Overall Dimensions | 480 mm × 360 mm × 520 mm (W × D × H) |
| Net Weight | 18 kg |
| Operating Humidity | ≤85% RH |
| Max. Power Consumption | ≤1800 W |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TP-673 |
| Pricing | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dualstream 3 |
| Pricing | Available Upon Request |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | AFP1 |
| Test Method | Closed Cup (ABEL) |
| Operation Mode | Fully Automatic |
| Applicable Standards | EN 924, IP 170, IP 491, IP 492, ISO 1516, ISO 3679, ISO 13736 |
| Temperature Range | −50 °C to +100 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.06 °C |
| Repeatability | ±0.1 °C |
| Sensor | Class A PT100 |
| Ignition System | Dual electric spark igniter with ionization flame detection |
| Sample Cup | Brass, ASTM-compliant geometry |
| Safety Features | Thermal cut-off, automatic shutter, integrated flame detection |
| Dimensions (W×D×H) | 310 × 470 × 520 mm |
| Weight | 27 kg |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Display | 8.4″ TFT/LCD touchscreen interface |
| Data Output | Excel-compatible CSV export |
| Compliance | GLP/GMP-ready audit trail, 21 CFR Part 11–compatible software architecture |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | ASTM D1831 |
| Test Method | Open-Cup |
| Operation Mode | Automatic |
| Applicable Standards | ASTM D1831, ASTM D7342 |
| Repeatability | ±0.1°C |
| Ignition Method | Automated temperature-controlled testing |
| Temperature Range | Up to 200°C |
| Rotational Speed | Up to 300 rpm |
| Timer Range | 1 minute to 100 hours |
| Temperature Control Accuracy | ±1°C |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | CFP |
| Test Method | Cleveland Open Cup (COC) |
| Operation Mode | Semi-Automatic (Manual Sample Loading + Automated Detection & Control) |
| Applicable Standards | ASTM D92, FTM 791-1103, IP 36, ISO 2592, JIS K2265-4 |
| Temperature Range | +79 °C to 400 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.06 °C |
| Heating Sensor | Class A PT100 |
| Ignition System | Dual electric igniters + pilot flame |
| Detection Principle | Ionization-based flame detection |
| Safety Features | Thermal cutoff, real-time fire detection, self-diagnostic routines |
| Dimensions (W×D×H) | 48 × 37 × 61 cm |
| Weight | 32 kg |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Data Output | Excel-compatible CSV files |
| Display | 8-inch integrated TFT/LCD touchscreen PC |
| Brand | Ducom |
|---|---|
| Model | CPP |
| Origin | USA |
| Type | Integrated Dual-Function Petroleum Low-Temperature Property Analyzer |
| Temperature Range | –80 °C to +80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C (PT100 Class A) |
| Cooling System | Single-stage (to –40 °C) or Dual-stage (to –80 °C), CFC-free motor-compressor |
| Detection Methods | Cloud Point — coaxial infrared optical pulse detection |
| Compliance | ASTM D2500, D5771–D5773, D97, D5853, D5950 |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Dimensions (W×D×H) | 66 × 60 × 80 cm |
| Weight | 60 kg (max 6-test-head configuration) |
| Interface | 12″ integrated high-resolution TFT/LCD touch-panel PC |
| Brand | Ducom |
|---|---|
| Model | DPP |
| Type | Automatic Pour Point Tester |
| Origin | USA |
| Cooling Capacity | Single-stage to –40°C, Dual-stage to –80°C |
| Temperature Range | –80°C to +80°C |
| Resolution | 0.06°C |
| Accuracy | ±0.1°C |
| Repeatability | Compliant with ASTM D5950, ISO 3016, and IP 441 |
| Temperature Sensor | Class A PT100 |
| Display | 12″ TFT/LCD Touchscreen PC |
| Power Supply | 220 V ±15% / 50–60 Hz or 115 V ±15% / 60 Hz |
| Dimensions (W×D×H) | 66 × 60 × 80 cm |
| Weight | 60 kg (max. 6 test heads) |
| Standards Compliance | ASTM D97, D5853, D5950 |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | FPM |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automated |
| Compliant Standards | ASTM D93 (Methods A, B, C), DIN EN 22719, IP 34, ISO 2719 |
| Temperature Range | 0 °C to 420 °C |
| Temperature Resolution | 0.01 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.1 °C |
| Ignition System | Automated electronic spark ignition with temperature-controlled test sequence |
| Sample Chamber | Stainless steel, corrosion- and impact-resistant |
| Temperature Sensors | Dual PT100 (sample & bath) |
| Dimensions (W×D×H) | 37 × 52 × 32 cm |
| Weight | 30 kg |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Brand | Ducom |
|---|---|
| Model | FPT |
| Origin | USA |
| Category | Petroleum Low-Temperature Property Tester |
| Cooling Range | −90 °C to +80 °C |
| Temperature Resolution | 0.01 °C |
| Accuracy | ±0.1 °C |
| Repeatability | Compliant with ASTM D2386, D5972, D7154 and IP 528 |
| Temperature Sensor | Class A PT100 |
| Cooling System | Fluorocarbon-free dual-stage refrigeration |
| Detection Method | Coaxial fiber-optic infrared pulse reflection with mirror-enhanced crystal detection |
| Stirring Mechanism | Motor-driven triple-brass-coil agitator |
| Power Supply | 220 V ±15 %, 50–60 Hz or 115 V ±15 %, 60 Hz |
| Dimensions (W×D×H) | 34 × 60 × 80 cm |
| Weight | 34 kg |
| Standards Compliance | ASTM D2386, D5972, D7154, D852, D1177, D1655 |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | Noac |
| Temperature Range | 0–320 °C |
| Test Range | 225–275 °C |
| Temp. Resolution | 0.01 °C |
| Temp. Accuracy | ±0.1 °C |
| Temp. Repeatability | ASTM D5800-compliant |
| Vacuum Control | –2 mbar (electronic, continuous) |
| Pressure Differential | 20 mmH₂O (auto-regulated) |
| Vacuum Accuracy | ±1% |
| Heating Method | Oil Bath (Method A) or Sample-Controlled (Method B) |
| Compliance | ASTM D5800, IP 42 |
| Dimensions | 40 × 45 × 45 cm (W×D×H) |
| Weight | 22 kg |
| Power | 220 V ±15%, 50–60 Hz or 115 V ±15%, 60 Hz |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DVV2000 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DRS2170 |
| Pricing | Upon Request |
| Brand | Eastern-Dataphy |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrumentation |
| Model | VMF100 |
| Pricing | Upon Request |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | aqua 40.00 |
| Measurement Range | 1 µg – 100 mg |
| Resolution | 0.1 µg |
| Repeatability | ±3 µg (for 10–1000 µg water) |
| Temperature Control Range | 35 °C – 300 °C |
| Power Supply | 230 V |
| Sample Introduction | Optional automated sample changer |
| Gas System | Closed-loop, carrier-gas-free dynamic headspace |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software support |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aquamax KF PRO OIL |
| Product Type | Laboratory Instrument |
| Measurement Parameter | Trace Water Content (ppm to %) |
| Compliance | ASTM D6304, GB/T 11133 |
| Measurement Range | 0.0001–99% w/w |
| Heating Temperature Range | 35–250 °C (isothermal or programmable ramp) |
| Sample Introduction | Direct injection into heated furnace |
| Carrier Gas | Not required (closed-loop system) |
| Reagent Consumption | Single reagent cartridge supports >1000 determinations |
| Water Speciation | Differentiates free water and chemically bound water via thermal profiling |
| Blank-Free Operation | Eliminates need for blank correction |
| Form Factor | Benchtop / Portable field unit |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Sulfur Titrator |
| Pricing | Upon Request |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | TAN/TBN Titrator |
| Application Standard Compliance | IEC 62021-1, ISO 3771, ASTM D664, ASTM D2896, ASTM D4739 |
| Titration Method | Potentiometric Volumetric Titration in Anhydrous Medium |
| Measurement Range | 0.01–250 mg KOH/g |
| Resolution | 0.01 mg KOH/g |
| Power Supply | 100–240 V AC, 50/60 Hz, 30 VA |
| Stirrer Output | 12 V DC, 500 mA |
| Dimensions (W × H × D) | 30 × 45 × 30 cm (including reagent changer height) |
| Weight | ~3.5 kg (with reagent changer and empty bottles) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Accessory Kit |
| Pricing | Upon Request |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Compliance | ASTM D3948, ASTM D4860 |
| Design | Integrated portable analyzer with built-in audio-guided test protocol |
| Test Duration | 5–10 minutes per sample |
| Sample Volume | Low-consumption (≤50 mL typical) |
| User Interface | Touch-sensitive control panel |
| Test Kit | Standard six-piece test assembly (pre-calibrated, disposable-compatible) |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 1143 |
| Pricing | Upon Request |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1153 |
| Measurement Range | 0–2000 pS/m |
| Resolution | ±1 pS/m (0–2000 pS/m) |
| Accuracy | ±2% of reading |
| Operating Temperature | 0–50 °C |
| Display | 5-digit LCD with status text and LED illumination |
| Power | Three 3 V lithium batteries |
| Dimensions | 200.7 × 70 × 43.2 mm (L×W×D) |
| Probe Diameter | 19.05 mm |
| Weight | 365.8 g (12.9 oz) |
| Enclosure | Intrinsically Safe for Class I, Division 1, Group D hazardous locations |
| Compliance | ASTM D2624 |
| Optional Features | Temperature measurement mode, data hold, solvent-resistant hard-shell carrying case with O-ring sealed probe interface |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | JFTOT MARKIII |
| Compliance | ASTM D3241, GB/T 9169 |
| Consumables | Heating Rod & MNKJG0605 Filter Assembly |
| Supply Channel | Authorized Distributor |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Standard Compliance | ASTM D3948, SH/T 0616–1995 |
| Test Principle | Gravimetric optical transmittance measurement of water separation kinetics in jet fuel |
| Accessories Included | Precision glass syringes, calibrated transfer pipettes, test cuvettes, reference standards |
| Configuration | Portable benchtop unit with integrated timer and optical sensor module |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Compliance | ASTM D3948, SH/T 0616-1995 |
| Application | Aviation Turbine Fuel (Jet A/Jet A-1) Water Separation Performance Testing |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Model 1140 |
| Unit Price | USD 1.00 |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Compliance | ASTM D3948, D4860, D7224, D7261, SH/T 0616 |
| Sample Volume | 150 mL |
| Test Duration | 5 minutes per run |
| Display | Digital LCD |
| Design | Portable benchtop unit with integrated timer and full accessory set |
| Repeatability | High (±0.5 units typical under controlled conditions) |