| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Measurement Parameters | pH, mV (ORP), Temperature |
| pH Range | -2.000 to 20.000 pH |
| Resolution | 0.001 pH |
| Accuracy | ±0.002 pH |
| Temperature Range | -10.0 to 135.0 °C |
| Temperature Resolution | 0.1 °C |
| mV Range | -2000.00 to 2000.00 mV |
| mV Resolution | 0.1 mV |
| Calibration Options | Up to 5-point pH calibration |
| Buffer Standards Supported | GB, DIN, NIST, USA, MERK |
| Data Storage Capacity | 500 measurement sets |
| Connectivity | RS-232 (printer), USB (PC communication) |
| Compliance | GLP-compliant data logging with user ID / sample ID assignment |
| Power Supply | DC 9 V adapter (AC 100–240 V input) |
| Dimensions | 242 × 195 × 68 mm |
| Weight | 0.9 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHSJ-4F |
| Instrument Type | Benchtop |
| Parameter Types | pH, mV (ORP), Temperature |
| Measurement Accuracy | ±0.002 pH |
| pH Range | −2.000 to 20.000 pH |
| pH Resolution | 0.001 pH |
| Temperature Range | −5.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| mV Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1 mV |
| Stability | ±0.002 pH ±1 digit / 3 h |
| Power Supply | 9 V DC, 800 mA (center-positive) |
| Dimensions | 280 × 215 × 92 mm |
| Weight | 1 kg |
| Data Storage | 500 sets with GLP-compliant metadata (date/time, electrode ID, calibration history, temperature) |
| Calibration | 1–3 point, auto-buffer recognition for 5 standard pH buffers (pH 4.01, 6.86, 7.00, 9.18, 10.01) |
| Connectivity | USB to PC, RS-232 to serial printer |
| Operating Modes | Smart-Read (auto-endpoint detection), Timed-Read (programmable interval storage), Cont-Read (continuous real-time display) |
| Additional Features | Electrode condition alert, calibration due reminder, auto-temperature compensation (ATC), firmware upgradability, power-loss data retention |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PHSJ-5T |
| Price Range | USD 700–1,400 |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV/ORP/Temperature) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | −2.000 to 20.000 pH |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Calibration Standard | NIST-traceable buffers |
| IP Rating | IP54 |
| Compliance | GLP, GMP-ready, FDA 21 CFR Part 11-compatible data management |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHSJ-5T |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV/ORP/Temperature) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | −2.000 to 20.000 pH |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Temperature Compensation | Automatic (−10.0 to 135.0 °C) |
| Calibration Standards | NIST, GB, DIN, USA, MERK, JIS (6 pre-programmed sets + custom buffer definition) |
| Data Storage | 1000 measurement records with GLP/GMP-compliant metadata |
| Compliance | GLP, GMP-ready with audit trail, user-level permissions, and electronic signature support |
| Connectivity | RS-232, USB, U-disk interface, optional autosampler integration |
| IP Rating | IP54 |
| Power Supply | AC 100–240 V input, DC 24 V output |
| Dimensions & Weight | 220 × 195 × 68 mm, 0.95 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, ORP, Temperature) |
| Measurement Accuracy | ±0.002 pH |
| pH Range | −2.000 to 20.000 pH |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Temperature Compensation | Automatic (−10.0 to 135.0 °C) |
| Calibration Options | 1–6 point pH, 1 point ORP |
| Buffer Recognition | GB, DIN, NIST, USA, MERK, JIS (6 preloaded sets) + user-defined |
| Data Storage | 1000 measurement records with GLP/GMP-compliant metadata |
| Compliance | GLP, GMP-ready audit trail, 21 CFR Part 11 compatible software support |
| Connectivity | RS-232, USB, optional autosampler interface |
| IP Rating | IP54 |
| Power | DC24V adapter (AC100–240V input) |
| Dimensions & Weight | 220 × 195 × 68 mm, 0.95 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Types | pH, mV, Temperature |
| Measurement Range | pH: –2.000 to 20.000 |
| mV | –2000.00 to 2000.00 mV |
| Resolution | 0.001 pH / 0.01 mV |
| Accuracy | ±0.002 pH / ±0.03% FS (mV) |
| Temperature Compensation | Automatic (ATC), –5.0 to 135.0 °C |
| Calibration | Up to 6-point automatic calibration with auto-buffer recognition (GB, DIN, NIST, and 22 additional standard buffer sets) |
| Data Storage | 1000 measurement records with timestamp, electrode ID, calibration history, and user log |
| Compliance | GLP-compliant data management, audit trail support, 21 CFR Part 11–ready software configuration (when used with Leici LabManager Pro v3.2+) |
| Connectivity | RS-232, USB host/device, optional auto-sampler interface |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PHSJ-6L |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter |
| Measurement Accuracy | 0.001 pH / ±0.002 pH |
| Measurement Range | (−2.000 to 20.000) pH |
| Resolution | 0.001 pH |
| Temperature Range | (−10.0 to 135.0) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C (electronic unit) |
| Calibration Standards Supported | GB, DIN, NIST, USA, MERK, JIS |
| Protection Rating | IP54 |
| Channels | 4 modular slots (expandable to 4 pH modules) |
| Data Storage Capacity | 1000 pH measurements, 100 calibration records, 1000 standard verification logs |
| Interface | RS-232, USB, optional barcode scanner & autosampler integration |
| Compliance | GLP-compliant |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHSJ-6L |
| Instrument Type | Benchtop |
| Parameter Types | pH, mV (ORP), Temperature |
| Measurement Accuracy | ±0.002 pH |
| Measurement Range | −2.000–20.000 pH |
| Resolution | 0.001 pH |
| Calibration Standards Supported | GB, DIN, NIST, and 22 additional certified buffer sets |
| Auto-Calibration Points | 1–6 points |
| Temperature Compensation | Automatic (ATC) with integrated sensor or manual entry |
| Data Storage Capacity | 1000 measurement records with metadata (timestamp, electrode ID, calibration status, operator ID) |
| Compliance | GLP-compliant audit trail, 21 CFR Part 11-ready configuration options |
| Connectivity | USB port for PC communication and USB flash drive data export |
| Power Supply | 24 V DC adapter (100–240 V AC input) |
| Dimensions (W×D×H) | 280 × 280 × 130 mm |
| Weight | 2.5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter (pH, ORP, mV, Temperature) |
| pH Measurement Range | –2.00 to 20.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Calibration | Automatic recognition of GB, DIN, NIST, and other standard pH buffer solutions |
| Data Storage | 500 measurement records with GLP-compliant metadata |
| Environmental Rating | IP65 |
| Connectivity | RS232 printer port, USB interface for PC communication and firmware updates |
| Calibration Options | 1–5 point pH calibration, 1-point ORP calibration |
| Measurement Modes | Continuous, equilibrium-based, and programmable timed (interval or continuous timing) |
| User Management | Configurable user ID and sample ID fields |
| Display | Backlit LCD with graphical curve visualization |
| Brand | Lemon |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| pH Measurement Range | −2.000 to 20.000 pH |
| pH Resolution | 0.001 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | −2000.00 to +2000.00 mV |
| mV Resolution | 0.01 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −5.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Stability | ±0.002 pH / 3 h |
| Calibration Points | 1–6 points automatic |
| Buffer Recognition | GB, DIN, NIST, and 22 additional standard buffer sets (25 total) |
| Data Storage Capacity | 1000 measurement records |
| Compliance | GLP-compliant data management with audit trail support |
| Connectivity | RS-232, USB host (for U-disk), optional PC software interface |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FE20K |
| Price | USD 580 (approx.) |
| pH Range | 0.00–14.00 |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| mV Range | ±1999 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0–100 °C |
| Calibration Points | Up to 3-point |
| Temperature Compensation | Automatic or Manual |
| Endpoint Detection | Automatic or Manual |
| Buffer Recognition | Yes |
| Electrode Status Indicator | Yes |
| Slope Display | Yes |
| Reference Electrode Input | Yes |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 826 (portable) / 827 (benchtop) |
| pH Range | 0–14 (extended range: –8 to 22) |
| mV Range | ±1200 mV |
| Temperature Range | –150.0 to +250.0 °C (Pt1000 sensor) / –5.0 to +250.0 °C (NTC sensor) |
| pH Resolution | 0.001 |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| Interface | Infrared (IrDA) for wireless data transfer to printers and PCs |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 826 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter |
| Connectivity | IrDA (Infrared Data Association) |
| GLP Compliance | Yes |
| Data Storage Capacity | 200 measurements (with timestamp, date, and ID) |
| Power Supply | 4 × 1.5 V LR6 (AA) alkaline batteries |
| Battery Life | ≥500 hours |
| Ingress Protection Rating | IP67 |
| Electrode Compatibility | Primatrode series (e.g., 6.0228.020) |
| Calibration | Auto-buffer recognition, automatic temperature compensation (ATC), up to 3-point calibration |
| Software Integration | Metrodata VESUV 3.0, LIMS-compatible export |
| Operating Interface | Cursor-controlled text-guided menu |
| Enclosure Material | High-grade polymer with ergonomic, lab-grade finish |
| Optional Accessory | Integrated carry case with fold-out workstation surface |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 826 |
| pH Range | 0.000–14.000 (extended: –8.000 to 22.000) |
| mV Range | ±1200.0 mV |
| Temperature Range | –150.0 to +250.0 °C (Pt1000 sensor) / –5.0 to +250.0 °C (NTC sensor) |
| pH Resolution | 0.001 |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| Interface | Infrared (IrDA) for wireless data transfer to printers and PCs |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 827 |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 827 |
| pH Range | 0.000–14.000 (extended: –8.000 to 22.000) |
| Potential Range | ±1200 mV |
| Temperature Range | –150.0 to +250.0 °C (Pt1000 sensor) / –5.0 to +250.0 °C (NTC sensor) |
| pH Resolution | 0.001 |
| Potential Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| Interface | Infrared (IrDA), RS232, USB (via optional adapter) |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation environment |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported |
| Model | 867 |
| Form Factor | Portable |
| Measurement Modes | pH, mV (Redox), Temperature, Ion Concentration (via ISE) |
| Calibration Points | 1–9-point |
| Interface | 2× USB, 4× MSB (Metrohm Serial Bus) |
| Regulatory Compliance | FDA 21 CFR Part 11–ready (when integrated with tiamo™ or TitraLab® software), GLP/GMP-compliant data handling |
| Electrode Support | Compatible with iTronde™ intelligent electrodes and conventional analog electrodes |
| System Integration | Standalone operation or fully embedded in Metrohm Titrando® titration systems and tiamo™ software platform |
| Configuration Options | 2.867.0010 (Basic pH Module), 2.867.0110 (pH Module with Touch Control), 2.867.0210 (pH Module with tiamo™ integration) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 913 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH) |
| Measurement Accuracy | ±0.001 pH |
| IP Rating | IP67 |
| Display | Color LCD with Multilingual Support |
| Data Management | GLP-Compliant Logging, tiBase Integration, LIMS/Excel Export Capability |
| Electrode Interface | Standard BNC + Optional Smart Electrode Adapters |
| Operating Modes | Field, Laboratory, and Process-Support Configurations |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Benchtop pH Meter |
| Model | 949 |
| Measurement Modes | pH, mV, ORP, Temperature |
| pH Range | −2.00 to 16.00 (resolution: 0.01 pH) |
| mV/ORP Range | −1000.0 to +1999.9 mV (resolution: 0.1 mV) |
| Temperature Range | −10.0 to +110.0 °C (resolution: 0.1 °C) |
| Calibration | Automatic buffer recognition (built-in IUPAC/NIST/USP/DIN buffer tables), up to 5-point calibration |
| Temperature Compensation | Automatic (ATC) and manual |
| Data Storage | Up to 1,000 measurement records with timestamp (date/time stamping) |
| Interface | RS232 serial port for printer or PC connection |
| Compliance | GLP-compliant reporting, audit-ready data logging, electrode calibration reminder |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | FE20 |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| Relative pH Accuracy | ±0.01 |
| mV/ORP Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| Relative mV Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with 4 pre-defined buffer sets |
| Display | LCD |
| Power Supply | External AC adapter |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE20K |
| Instrument Type | Benchtop (not portable) |
| Parameter Type | Single-parameter (pH/mV/ORP) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with auto-buffer recognition for 4 pre-defined IUPAC/NIST-compatible buffers |
| Data Storage | 99 measurement records |
| Interface | RS232 |
| Display | Backlit LCD showing pH/mV value, temperature, endpoint status, and calibration indicators |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE28 / S210-K |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH + mV/ORP) |
| pH Range | −2.00–16.00 pH (FE28) / −2.000–20.000 pH (S210-K) |
| pH Resolution | 0.01 pH (FE28) / 0.001–0.1 pH selectable (S210-K) |
| pH Accuracy | ±0.01 pH (FE28) / ±0.002 pH (S210-K) |
| mV Range | ±2000 mV (FE28) / ±2000.0 mV (S210-K) |
| mV Resolution | 1 mV (FE28) / 0.1 or 1 mV selectable (S210-K) |
| mV Accuracy | ±1 mV (FE28) / ±0.2 mV (S210-K) |
| Temperature Range | −5 to 105 °C (FE28, manual/auto) / −30.0 to 130.0 °C (S210-K, manual) |
| Temperature Accuracy | ±0.1 °C (S210-K) |
| Calibration Points | Up to 5-point pH calibration |
| Buffer Recognition | Automatic (NIST, DIN, JIS, ISO, METTLER TOLEDO standard buffers) |
| Data Storage | 200 measurement records |
| Connectivity | RS232 and USB |
| Electrode Interface | Standard BNC (FE28) / ISM-enabled Smart Socket (S210-K) |
| Temperature Compensation | Automatic and manual |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | FE28-Meter |
| Instrument Type | Portable |
| Parameter Types | pH, Conductivity, Dissolved Oxygen |
| pH Measurement Range | −2.00 to 16.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 (at 25 °C) |
| pH Calibration Points | Up to 5 |
| Predefined Buffer Sets | 4 |
| Temperature Range | 0 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
| Data Storage | 200 measurement records + active calibration data |
| Interface | RS232 and USB |
| Reference Input | Yes |
| Audible Signal | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Italy |
| Model | FE28 |
| Instrument Type | Benchtop |
| Parameter Types | pH and mV (single-channel) |
| pH Measurement Range | -2 to 16 |
| pH Resolution | 0.01 / 0.1 |
| pH Accuracy | ±0.01 |
| mV Measurement Range | 0 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 |
| Temperature Range | -5 °C to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Data Storage Capacity | 200 measurements |
| Connectivity | RS232 and USB |
| Electrode Included | LE438 pH electrode |
| ISM Support | Not supported |
| Calibration Solution Compatibility | China-specific calibration buffers |
| Compliance | Designed for GLP-compliant routine lab use |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | FE28-Standard |
| Instrument Type | Benchtop (not portable — corrected per technical specification) |
| Parameter Types | pH, mV, Temperature |
| Measurement Range | -2.00 to 16.00 pH |
| Resolution | 0.01/0.1 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±1 mV, ±0.3 °C |
| Temperature Compensation | Automatic and Manual |
| Calibration Points | Up to 5-point |
| Calibration Modes | Linear and Segmented |
| Predefined Buffers | 4 sets (including US, NIST, DIN, and Chinese standards) |
| Data Storage | 200 measurement records + current calibration data |
| Connectivity | BNC, Cinch, NTC 30 kΩ, RS232, USB |
| Display | 4.3-inch segmented LCD |
| Housing Material | ABS |
| Dimensions / Weight | 227 × 147 × 70 mm / 0.63 kg |
| Power Supply | 100–240 V AC, 50–60 Hz / 12 V DC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE30 / FE30K |
| Instrument Type | Benchtop |
| Parameter Types | Conductivity, TDS, Salinity, Resistivity, Temperature |
| Measurement Range | 0.00 µS/cm – 199.9 mS/cm (equivalent to 0.00 mg/L – 199.9 g/L TDS) |
| Resolution | Automatic, 0.01 µS/cm to 0.1 mS/cm (conductivity) |
| Accuracy | ±0.5% of reading |
| Calibration Solutions | Standardized US-type conductivity standards (e.g., 84 µS/cm, 1413 µS/cm, 12.88 mS/cm) |
| Temperature Compensation | Linear, with selectable reference temperature (15–25 °C default) |
| Compliance | Designed per IEC 61010-1 for laboratory electrical safety |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| Parameter Capability | Multi-parameter (pH, mV, °C, Conductivity) |
| pH Range | –2.00 to 16.00 |
| mV Range | –2000 to +2000 mV |
| Temperature Range | 5 to 105 °C |
| pH Resolution | 0.01 / 0.1 |
| mV Resolution | 1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 |
| mV Accuracy | ±1 mV |
| Temperature Accuracy | ±0.3 °C |
| Calibration Points | Up to 5-point (linear or segmented) |
| Predefined Buffers | 4 sets |
| Data Storage Capacity | 200 measurement records |
| Electrode Interfaces | BNC, Cinch, NTC 30 kΩ |
| Connectivity | RS232, USB |
| ATC Support | Yes (optional probe, P/N 12997876) |
| Display | 4.3-inch segment LCD |
| Housing Material | ABS |
| Dimensions (W × H × D) | 227 × 147 × 70 mm |
| Weight | 0.63 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FG2 |
| Instrument Type | Portable |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy (relative) | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy (relative) | ±1 |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with 4 predefined buffer sets |
| Data Storage | 30 measurements |
| Display | LCD |
| Power Supply | 4 × AAA 1.5 V batteries |
| IP Rating | IP54 |
| Operating Environment | 0–40 °C, 5–80 % RH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | −2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Standards | Chinese JJG 119 / USP |
| Display | Large backlit LCD |
| Connectivity | RS232 and USB ports |
| Electrode Holder | Removable and stowable |
| Dimensions | 227 × 147 × 70 mm |
| Weight | 0.63 kg |
| Compliance | Designed for GLP-compliant workflows |