Pharmaceutical Testing Specialized Instruments
Filter
Showing 451–480 of 791 results
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | WGT-1000 |
| Power Supply | DC 12 V, 20 W |
| Test Accuracy | Detects leaks equivalent to ≥300 µm aperture |
| Test Duration | 3–8 min |
| Pressure Range | 500–3000 Pa |
| Pressure Resolution | 0.1 Pa |
| Noise Level | ≤50 dB(A) |
| Communication Method | Wi-Fi |
| Gas Source | Built-in sanitary air pump |
| Maximum Sealing Pressure | ≤200 kPa |
| Data Storage Capacity | >12,000 test records |
| Glove Identification | RFID or manual input |
| Enclosure Rating | IP65 |
| Weight | 4.2 kg |
| Display | Color touchscreen interface |
| Compliance | FDA 21 CFR Part 11, GMP, ISO 14644-7:2004, GB/T 25915.7–2010 |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | WGT-1200 |
| Price | Upon Request |
| Power Supply | DC 12 V, 20 W |
| Built-in Battery | 12 V Li-ion |
| Detection Accuracy | Minimum Detectable Hole Size: 300 µm |
| Test Duration | 3–8 min |
| Pressure Range | 500–3000 Pa |
| Pressure Resolution | 0.1 Pa |
| Noise Level | ≤50 dB(A) |
| Communication | Wi-Fi |
| Air Source | Integrated Sanitary-Grade Diaphragm Pump |
| Maximum Seal Pressure | ≤200 kPa |
| Data Storage Capacity | >12,000 test records |
| Data Storage Medium | Onboard Flash Memory |
| Glove Identification | RFID or Manual Entry |
| Unit Weight | 4.2 kg |
| Max. Controlled Test Units per Controller | 10 |
| Operating Time | Up to 8 h continuous / >48 h standby |
| User Accounts | 120 max |
| Predefined Test Protocols | 120 max |
| Access Control | Four-Tier Role-Based Permissions |
| Software Compliance | FDA 21 CFR Part 11 (Electronic Records & Signatures), GMP Annex 11, ALCOA+ Principles |
| Brand | New Chi Scientific (Scientz) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CSD01 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | NIJI-2 |
| Pricing | Upon Request |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MDS-2008 |
| Instrument Type | On-line Dissolution Tester |
| Dissolution Vessels | 6 or 8 |
| Temperature Range | Ambient to 45.0 °C |
| Temperature Accuracy | ≤ ±0.2 °C |
| Rotation Speed Range | 25.0–250.0 rpm |
| Paddle Wobble Amplitude | ≤ 0.5 mm |
| Basket Wobble Amplitude | ≤ 1.0 mm |
| Water Bath Temperature Control Range | Ambient to 45.0 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 28 L |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | On-line Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Control Range | Ambient to 45 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.2 °C |
| Rotational Speed Range | 25–250 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤0.5 mm |
| Water Bath Volume | 32 L |
| Vessel Options | 250 mL and 1000 mL (amber glass option available) |
| Independent Temperature Monitoring | 14 built-in PT100 probes |
| User Interface | 10-inch color capacitive touchscreen |
| Method Storage Capacity | 144 protocols |
| Audit Trail Compliance | 3-tier user permission system with electronic signature support |
| Data Output | Built-in thermal printer + USB export (proprietary .scd format) |
| Automation Features | Auto-dosing module (simultaneous or sequential 8-vessel dosing), auto-level monitoring, voice status alerts, unattended pre-heating scheduling |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SC-CMII |
| Pricing | Available Upon Request |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | THT-1350 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | V4 |
| Price | USD 5,300 (approx.) |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (mm) | 400 D × 240 W × 270 H₁ × 220 H₂ |
| Weight | 7.5 kg |
| Display | 5.7″ monochrome TFT LCD with backlight |
| Interface | RS232 serial port |
| Language Support | English & Chinese |
| Test Modes | Manual Bubble Point, Basic Bubble Point, Enhanced Bubble Point, Diffusion Flow, Water Intrusion |
| Accuracy | Net Volume ±4% |
| Measurement Ranges | Bubble Point 590–6900 mbar |
| Sample Compatibility | Symmetric & asymmetric membranes |
| Data Storage | 500 test records |
| Application Environment Classification | ISO Class B or better |
| Compliance Context | Designed for use in GMP-compliant pharmaceutical manufacturing and QC laboratories |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM21-060H-1 |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | PQ001-NMR01 |
| Pricing | Upon Request |
| Magnet Type | Permanent Magnet |
| Static Magnetic Field Strength | 0.5 ± 0.08 T |
| Larmor Frequency (¹H) | 21.3 MHz |
| Probe Coil Diameter | 10 mm |
| Effective Sample Volume | Ø10 mm × H20 mm |
| Nuclei Supported | ¹H, ¹⁹F |
| Quantification Range | 10–90 wt% per component |
| Sample Form | Solid APIs (powders, granules, compacts), no requirement for homogeneity or mechanical uniformity |
| Brand | North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BQS-80 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (150 psi) |
| Pressure Units | mbar, kPa, psi, kgf/cm² |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (L×W×H) | 480 × 300 × 210 mm |
| Weight | 10 kg |
| IP Rating | Front Panel IP65, Main Unit IP54 |
| Display | 10-inch high-resolution color touchscreen |
| Test Methods | Manual Bubble Point, Basic Bubble Point, Enhanced Bubble Point, Hold Pressure, Diffusion Flow, Water Intrusion, Ultrafiltration Membrane Pack Testing |
| Accuracy | Bubble Point ±50 mbar |
| Measurement Ranges | Bubble Point 100–8000 mbar |
| Sample Compatibility | Symmetric & asymmetric membranes, syringe filters, capsule filters, flat-sheet filters, cartridge filters (up to 12-core, ≤20 inch), ultrafiltration cassettes & columns, irregularly shaped filters |
| Data Storage | ≥5 years of audit trail logs |
| Compliance | FDA 21 CFR Part 11, EU CE Marked, GMP-aligned architecture |
| Connectivity | RS232, USB, optional RS485, 4–20 mA analog output, 12 V alarm output, wireless module (optional) |
| User Management | 1000 user accounts, four-tier permission hierarchy, customizable role-based access, electronic signature support |
| Predefined Protocols | Up to 1000 stored test methods |
| Built-in Thermal Printer | Non-ink, particle-free, legible for >10 years |
| Maximum Tubing Length Support | 100 m (optimized gas path algorithm) |
| Safety Features | Anti-backflow device, self-diagnostic on startup |
| Brand | Nosaka |
|---|---|
| Origin | Japan |
| Model | EKITEN-Read |
| Capsule Sizes | #00, #0, #1, #2, #3, #4 |
| Production Rate | 500–2,500 capsules/hour |
| Fill Volume Range | 0.075–0.85 mL |
| Fill Temperature Control | Ambient to 75 °C |
| Power Supply | 200 V, 3-phase, 50/60 Hz, 15 A |
| Compressed Air Requirement | 0.5 MPa |
| Dimensions (W×D×H) | 1,450 × 715 × 1,470 mm |
| Weight | 600 kg |
| Sealing Method | Heat-activated polymer tape seal |
| Drying Method | Filtered ambient-air convection (non-thermal) |
| Orientation Correction | Force-free quadrisectional alignment |
| Vacuum-Assisted Capping | Integrated vacuum-decompression system for bubble-free cap-body junction |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | V1.2 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (max. 115 psi) |
| Bubble Point Accuracy | ±75 mbar |
| Diffusion Flow Accuracy | ±4% |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Range | 1–180 mL/min |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (L×W×H) | 400 × 240 × 270 mm (base) + 220 mm (height with display module) |
| Weight | 7.5 kg |
| Display | 3.2″ monochrome LCD |
| Data Storage | 20 test records |
| Language | Chinese only |
| Test Modes | Bubble Point (fully automated), Diffusion Flow (semi-automated), Hold Pressure (pressure decay) |
| Sample Compatibility | Symmetric & asymmetric membranes |
| Cleanroom Suitability | ISO Class B and above |
| Compliance | Designed to support execution of ASTM F838-22, USP <1207>, EP 2.6.27, and ISO 13408-2 integrity test protocols |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 6.0 |
| Price | USD 11,800 (approx.) |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (14.5–145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (mm) | 400 D × 240 W × 270 H₁ × 220 H₂ |
| Weight | 8 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Water Intrusion Accuracy | ±0.01 mL |
| Net Volume Test Accuracy | ±4% |
| Bubble Point Range | 100–8,000 mbar |
| Diffusion Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Pre-stored Protocols | 80 |
| Audit Trail Events | 16+ logged parameters (user, timestamp, method, pressure, flow, pass/fail status, etc.) |
| Data Storage Capacity | >5,000 test records (unlimited with USB backup) |
| Display | 7" high-resolution color touchscreen |
| Interface Options | RS232, USB, optional industrial bus (e.g., Modbus TCP, Profibus DP) and analog I/O |
| Language Support | English & Chinese |
| Compliance | Fully aligned with USP <1207>, EP 2.6.27, ISO 13408-2, and FDA 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | Octopus |
|---|---|
| Origin | Germany |
| Model | SAMILLA FIM |
| Detection Principle | High-Resolution Flow Imaging Microscopy (HiRes-FIM) |
| Particle Size Range | 0.2 µm – 2 mm |
| Camera Options | 12 MP monochrome or color, high-frame-rate sensor |
| Auto-focus | Real-time autofocus without focus beads |
| Magnification Switching | Tool-free, RFID-recognized modular objectives |
| Compliance | USP <788>, USP <789>, Ph. Eur. 2.9.19, ISO 14644-1, FDA 21 CFR Part 11, GLP/GMP-ready |
| Software | SMILLA View v5.x with audit trail, electronic signatures, LIMS integration via ASTM E1384 / LADS framework |
| Cleaning | Fully automated post-run rinse and backflush cycle |
| Pump Configurations | MACRO (peristaltic), MICRO1 (single syringe), MICRO2 (dual alternating syringe), HYBRID (peristaltic + syringe) |
| Key Features | Microprocessor-controlled cryoscopic measurement |
|---|---|
| Sample volume | 30–50 µL (optional 15 µL configuration) |
| Measurement time | <60 s per sample |
| Accuracy | ±0.5% or ±2 digits (at 50 µL), ±1% or ±4 digits (at 30 µL) |
| Resolution | 1 mOsmol/kg |
| Measuring range | up to 3000 mOsmol/kg |
| Cooling system | Dual independent Peltier elements with electronic temperature regulation (±0.1 °C stability) |
| Display | 4½-digit LED |
| Dimensions | 220 W × 205 H × 360 D mm |
| Weight | 7 kg |
| Power supply | 110/230 V, 50/60 Hz |
| Compliance | Designed for GLP/GMP-aligned pharmaceutical QC environments |
| [Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSQ-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar (customizable sensor) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal flash memory (≥1,000,000 test records) |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Compliance | Fully supports GMP documentation requirements, audit trail-ready configuration, user-level access control (Operator/Supervisor/Admin), 21 CFR Part 11–compatible data handling with electronic signature support] |
| Brand | Particle Sizing Systems (PSS) |
|---|---|
| Origin | USA |
| Model | AccuSizer 780 A2000 SIS |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Light Obscuration (LO) and Enhanced Light Scattering (LS) |
| Size Range | 0.5 µm – 400 µm |
| Compliance | USP <787>, <788>, <789>, <1788>, Ch.P, EP, JP |
| Automation | Fully automated sampling, analysis, data processing, and system cleaning |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-3104 / SKD-3106 |
| Configuration | 4-channel or 6-channel modular distillation system |
| Detection Range | 1–600 g SO₂ (as per sample matrix and digestion protocol) |
| Control Interface | 7-inch high-resolution capacitive touchscreen |
| Heating Method | Far-infrared ceramic radiant heating (flame-free, uniform, corrosion-resistant) |
| Temperature Range | Ambient to 450 °C |
| Distillation Time Control | 1–600 min (per channel, independently programmable) |
| Cooling System | External compact compressor-based chiller with closed-loop water circulation |
| Anti-siphon Protection | Integrated one-way valve in condensate path |
| Automation Features | Independent channel control, built-in method library, programmable magnetic stirring (per receiver), automated nitrogen flow regulation, one-touch start/stop, timer-based endpoint detection |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-3106 |
| Type | Intelligent Automated Distillation System |
| Heating Method | Far-infrared Ceramic Radiant Heating |
| Temperature Range | Ambient to 450 °C |
| Time Control | 1–600 min |
| Distillation Channels | 4 or 6 independent channels |
| Cooling System | External Compact Compressor-based Closed-loop Chiller |
| Display | 7-inch HD Touchscreen LCD |
| Control Core | Microcontroller-based Embedded System |
| Anti-siphon Protection | Integrated One-way Flow Valve |
| Nitrogen Flow Control | Built-in Regulated Pneumatic Module |
| Method Storage | Preloaded & User-Editable SOPs |
| Automation Level | Fully Unattended Operation (Heating, Cooling, Stirring, Distillation, N₂ Triggering, Endpoint Termination) |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-380 |
| Detection Range | 0–50 mg SO₂ |
| Detection Limit | ≤100 g solid or ≤100 mL liquid (sample-dependent) |
| SO₂ Recovery Rate | >99.5% |
| Repeatability (RSD) | ≤0.5% |
| Distillation Time | Programmable, 0–99 min per sample |
| Distillation Speed | 3–8 min/sample |
| Heating Power | Adjustable, 750–1500 W |
| Sample Processing Mode | Automatic & Manual dual mode |
| Memory Capacity | 100 programmable methods (acid volume, absorbent volume, distillation time) |
| Safety Features | Real-time liquid-level monitoring (acid, absorbent, condensate), dry-run protection for digestion cup (Peiou patented), automatic alarm & state-resume function |
| Optional | N₂ purge interface (specify at order) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Persee GMP Data Integrity Compliance Solution |
| Pricing | Available Upon Request |
| Brand | Pharma Test |
|---|---|
| Origin | Germany |
| Model | PT-DDS4 |
| Degassing Residual Oxygen | <5 ppm |
| Preheating Temperature | 37 °C ± 0.1 °C |
| Delivery Method | Pressurized (direct connection to deionized water supply) or Vacuum-assisted (from external reservoir) |
| Compliance | Designed in alignment with USP <711>, FDA Guidance for Industry on Dissolution Testing, and ICH Q5C stability requirements |
| Cleaning | Fully drainable, CIP-compatible design |
| Brand | Pharma Test |
|---|---|
| Origin | Germany |
| Model | SPT-6 |
| Compatibility | PTZ AUTO, PTZ AUTO EZ, PTZ-S tablet disintegration testers |
| Operation Mode | Immersion-based thermal penetration measurement |
| Sample Capacity | 6 positions |
| Bath Integration | Standalone Plexiglas water bath or integrated into PTZ platforms |
| Automation | Auto-detection and reporting of softening time when used with PTZ AUTO EZ series |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | ASP2000 |
| Instrument Type | Offline Dissolution System with Online Detection Capability |
| Sampling Capacity | 50 positions |
| Online Dilution Ratio | up to 1:100 |
| Compatible Detection Methods | UV-Vis Spectrophotometry and HPLC |
| Control Software | WinDiss32 |
| Integration | Designed for seamless coupling with all Pharma-test dissolution testers (e.g., PT-DT series) |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | ADS |
| Instrument Type | Offline Dissolution Tester |
| Dissolution Vessels | 6, 8, or 7 (configurable) |
| Temperature Range | 10–50 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 15–150 rpm |
| Paddle Wobble Amplitude | ≤1 mm |
| Basket Wobble Amplitude | ≤1 mm |
| Water Bath Temperature Control Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 12 L |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | DFC1220SP |
| Instrument Type | Offline Dissolution Tester |
| Configuration | Includes PTWS 1220 dissolution bath, PTFC-16 fraction collector, two PT-SP8 syringe pumps (or optional Ismatec peristaltic / CAT piston pumps), EPE-1220 automated sampling system or in-situ probe, ITM-1220 inline temperature monitoring (optional), TM-1220/TMA-1220 tablet drop alignment module (optional), PT-RP80 thermal printer (optional) |
| Compliance | USP <711>, USP <724>, Ph. Eur. 2.9.3 & 2.9.4 |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PT-DT Series |
| Instrument Type | Offline Dissolution Tester |
| Sample Positions | 8 |
| Dissolution Vessel Options | 250 mL, 1 L, 2 L, 4 L |
| Temperature Range | 25–45 °C |
| Temperature Accuracy | ±0.2 °C |
| Rotational Speed Range | 25–250 rpm |
| Speed Accuracy | ±1 rpm |
| Water Bath Volume | 35 L |
| Construction | Stainless Steel (GLP-compliant) |
| Modular Architecture | Supports upgrade to semi-automated (offline) and fully automated (online) configurations |
| Validation Support | IQ/OQ/PQ documentation and execution available |
| Regulatory Compliance | Designed to meet USP <711>, EP 2.9.3, JP XVII, and ChP (Chinese Pharmacopoeia) General Chapter 0931 requirements |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTB 211E |
| Measurement Principle | Constant-Speed and Constant-Force Methods |
| Force Range | 2–330 N |
| Resolution | 1 N |
| Optional Units | N, kp, Sc |
| Interface | RS-232, Parallel Printer Port |
| Compliance Option | 21 CFR Part 11–compliant Software Available |
| Sample Capacity | 1–30 mL Ampoules |