Pharmaceutical Testing Specialized Instruments
Filter
Showing 391–420 of 791 results
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Model | HPP2200eco |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10–90 % RH (dynamic humidification & dehumidification) |
| Cooling Technology | Solid-state Peltier |
| Energy Reduction vs. Compressor-Based Systems | Up to 90 % |
| Compliance | ICH Q1A, ICH Q5C, ISO 14644-1 (Class 5 cleanroom-compatible operation), GLP/GMP-ready |
| Calibration Points | User-selectable triple-point calibration (T/RH) on control interface |
| Optional | Dimmable LED Illumination System (2700 K / 6500 K / dual-color, 1 % step resolution) |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Type | Semiconductor-Cooled Stability Chamber |
| Model | HPP260eco |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10 %rh to 90 %rh (dynamic humidification & dehumidification) |
| Control Precision | ±0.1 °C (temp), ±1 %rh (humidity) |
| Cooling Technology | Solid-State Peltier |
| Energy Reduction vs. Compressor-Based Systems | Up to 90 % |
| Compliance | ICH Q1A(R3), ICH Q5C, ISO 14644-1 (Class 8), GLP-ready |
| Calibration Points | User-selectable triple-point calibration (T/RH) on touchscreen interface |
| Optional | Dimmable LED Illumination System (2700 K / 6500 K / Dual-White, 1 % step adjustment) |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Model | HPP410eco |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10–90 % RH (dynamic humidification & dehumidification) |
| Cooling Technology | Solid-state Peltier |
| Energy Reduction vs. Compressor-Based Chambers | Up to 90 % |
| Compliance | ICH Q1A(R3), ISO 14644-1 (Class 8), GLP/GMP-ready |
| Calibration Points | User-selectable triple-point adjustment (T/RH) on controller |
| Optional Illumination | Tunable LED lighting (2,700 K / 6,500 K / dual-channel, 1 % dimming resolution) |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | HPP750eco |
| Pricing | Upon Request |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | STABILITY-FITOCLIMA 5000PH |
| Temperature Range | 15–45 °C |
| Humidity Range | 35–90 % RH |
| Internal Volume | 5,000–25,000 L (customizable) |
| Compliance | FDA 21 CFR Part 11, ICH Q1–Q5, EU GMP Annex 15, ISO 14644-1 Class 8 (optional), GAMP 5 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DP70 |
| Temperature Range | 30–200 °C (standard), up to 400 °C (extended) |
| Heating Rate | 0.1–20 °C/min |
| Measurement Accuracy | ±0.2 °C (≤200 °C), ±0.5 °C (>200 °C) |
| Display | 5.7" VGA Color Touchscreen |
| Compliance | ASTM D3104, D3105, D3461, ISO 4625, USP <741> |
| Brand | MG2 |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FlexaLAB |
| Pricing | Available Upon Request |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | EFFU |
| Filter Material | Mixed Cellulose Ester (MCE) |
| Filter Diameter | 47 mm |
| Effective Filtration Area | 12.56 cm² |
| Funnel Capacity | 100 mL or 250 mL |
| Housing Material | Styrene-Butadiene Copolymer (SBC) |
| Cover Material | Polystyrene |
| Support Pad | Cellulose |
| Base Material | ABS (Acrylonitrile Butadiene Styrene) |
| Plug Material | Low-Density Polyethylene (LDPE) |
| Sterilization Method | Ethylene Oxide (EO) |
| Packaging | Individually or Multipack, Sterile, Pyrogen-Free |
| Compliance | Designed for USP <61>, <62>, EP 2.6.12, ISO 8573-7, and GLP-compliant workflows |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-0595 |
| Measurement Range | 0–650 Penetration Units (0.1 mm) |
| Minimum Readout | 0.1 Penetration Unit |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 Penetration Unit |
| Timing Options | 5 s, 8 s, 10 s, 12 s, 30 s, 60 s (timing error < ±0.1 s) |
| Standard Cone Mass | 102.5 ± 0.05 g |
| Power Supply | AC 220 ± 10% V, 50 Hz, ≤300 W |
| Dimensions | 280 × 350 × 700 mm (L×W×H) |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-0983H |
| Penetration Range | 0–650 dmm |
| Minimum Readout | 0.1 dmm |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Temperature Control Range | 0.00–50.00 °C |
| Temperature Stability | ±0.1 °C |
| Timing Range | 0–250 s |
| Timing Accuracy | ±0.1 s |
| LVDT Displacement Sensor Range | 0–66 mm |
| Displacement Resolution | 0.01 mm |
| Cone Mass (Type I) | 102.5 ± 0.05 g |
| Cone Rod Mass | 47.5 ± 0.05 g |
| Power Supply | 220 ± 10% VAC / 50 Hz |
| Net Weight | 12.5 kg |
| Dimensions (L×W×H) | 390 × 310 × 575 mm |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-154E |
| Penetration Range | 0–650 Penetration Units (0.1 mm per unit) |
| Minimum Readout | 0.1 Penetration Unit |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 Penetration Unit |
| Temperature Control Range | 0.00–50.00 °C (with ±0.1 °C stability) |
| Timing Accuracy | ±0.1 s (0–250 s programmable) |
| Displacement Sensor | Laser-based, 0–66 mm range, ±0.1 mm repeatability |
| Cone Assembly Mass | 37.5 g ±0.05 g (cone: 22.5 g ±0.025 g |
| rod | 15 g ±0.05 g) |
| Test Fixture | 200 mm diameter solid hemispherical PET support (Shore A hardness: 75–85) |
| Data Storage | 200 test records |
| Communication | RS-485 (MODBUS RTU), USB export |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-2102H |
| Measurement Range | 5–80 °C (water bath) / 32–162 °C (glycerol bath) |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 1.0–1.5 °C/min |
| Sample Capacity | 2 specimens simultaneously |
| Bath Vessel Dimensions | Ø110 mm × 130 mm H |
| Stirring | Adjustable magnetic stirrer |
| Data Storage | 200 test records (.csv export via USB) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Max. Power Consumption | 800 W |
| Net Weight | 12.0 kg |
| Dimensions (L×W×H) | 390 mm × 300 mm × 575 mm |
| Compliance | Chinese Pharmacopoeia 2020 Edition, General Chapter 2102 |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-22459D |
| Penetration Range | 0–650 dmm (0.1 mm increments) |
| Minimum Readout | 0.1 dmm |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Temperature Control Range | 0.00–50.00 °C (±0.1 °C stability) |
| Timing Range | 0–250 s (±0.1 s accuracy) |
| LVDT Displacement Sensor | 0–66 mm range, ≤±0.1 mm repeatability |
| Standard Cone Assembly | Total mass 102.5 g ±0.05 g, cone rod mass 47.5 g ±0.05 g (conforms to GB/T 22459.1–2008) |
| Data Storage | 200 test records |
| Communication | RS-485 (MODBUS RTU), USB data export |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions | 390 × 310 × 575 mm (L×W×H) |
| Net Weight | 12.5 kg |
| Brand | MMM |
|---|---|
| Origin | Germany |
| Chamber Volumes | 111 L, 222 L, 404 L, 707 L |
| Temperature Range | –10 °C / 0 °C to 99.9 °C (dry) |
| Temp. Uniformity | ±0.1 °C |
| Humidity Range | 10–95 %RH |
| Humidity Uniformity | ±1.5 %RH |
| Control Logic | Fuzzy PID |
| Refrigerant | R134a |
| Safety Class | EU Class 3.1 |
| Compliance | ICH Q1A(R3), Q1B(R2), cPMP/ICH/380/95, USP <1151>, ISO 14644-1 (Class 7 compatible), FDA 21 CFR Part 11 (software validation support) |
| Validation Support | IQ/OQ/PQ documentation and execution available in English & Chinese |
| Interface | RS232 |
| Programmability | Up to 16-step cycles with independent control of temperature, humidity, light intensity (visible & UV), fan speed, dwell time, ramp profiles, and cycle repetition |
| Brand | MultiGel |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MC100 |
| Pricing | Upon Request |
| Brand | NAI Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | NAI-JJY-Z |
| Pricing | Available Upon Request |
| Brand | NeuronBC |
|---|---|
| Model | BGT-100 |
| Origin | Beijing, China |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 0–5000 Pa |
| Pressure Resolution | 0.1 Pa |
| Response Threshold | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Dimensions | 370 × 220 × 210 mm |
| Weight | 4.5 kg |
| Data Storage Capacity | ≥10,000 test records |
| External Gas Source | Compressed air, nitrogen, or inert gas (≤0.5 MPa inlet pressure) |
| Audit Trail | Optional |
| Printer | Integrated thermal printer |
| Brand | NeuronBC |
|---|---|
| Model | BGT-120@ |
| Origin | Beijing, China |
| Power Supply | AC 220 V, 50 Hz with built-in Li-ion battery |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 0–5000 Pa |
| Pressure Resolution | 0.1 Pa |
| Response Threshold | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Dimensions | 370 × 220 × 210 mm |
| Weight | 4.5 kg |
| Data Storage Capacity | ≥10,000 test records |
| Compliance | ASTM F2095-01, FDA 21 CFR Part 11 (electronic records & signatures), GMP-aligned validation support (IQ/OQ/PQ/SOP) |
| Brand | NeuronBC |
|---|---|
| Model | BGT-120 |
| Principle | Pressure Decay Method (ASTM F2095-01) |
| Power Supply | AC 220 V, 50 Hz with Li-ion backup |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 0–5000 Pa |
| Pressure Resolution | 0.1 Pa |
| Response Threshold | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions | 370 × 220 × 210 mm |
| Weight | 4.5 kg |
| Audit Trail | Optional |
| Compliance | ASTM F2095-01, FDA 21 CFR Part 11 (electronic records & signatures), GMP-aligned validation support (IQ/OQ/PQ/SOP) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | BGT-120 |
| Power Supply | AC 220 V, 50 Hz with built-in Li-ion battery |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 0–5000 Pa |
| Pressure Resolution | 0.1 Pa |
| Response Threshold | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions | 370 mm × 220 mm × 210 mm |
| Weight | 4.5 kg |
| External Gas Source | Compressed air, nitrogen, or inert gas (≤0.5 MPa inlet pressure) |
| Audit Trail | Optional module compliant with FDA 21 CFR Part 11 requirements |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FPOSM-2.0 |
| Measurement Principle | Cryoscopic Depression (Ice Point Depression) |
| Measurement Range | 0–3000 mOsm/kg H₂O |
| Sample Volume | 50–70 µL |
| Pre-cooling Time | ≤3 min |
| Test Time | <2 min |
| Accuracy | ±1% (≤300 mOsm/kg and ≥400 mOsm/kg) |
| Repeatability (RSD) | ≤±1% at 300 mOsm/kg |
| Resolution | 1 mOsm/kg H₂O |
| Linearity | <1% (linear fit) |
| Calibration Points | 31-point programmable calibration (2-point or multi-point linear correction supported) |
| Display | Full-color LED LCD |
| Data Storage | 20,000 test records with recall & print capability |
| Built-in Pharmacopoeia Database | Preloaded Chinese Pharmacopoeia (2010 Edition) injection names |
| Cooling System | Dual-stage semiconductor refrigeration, refrigerant-free thermal transfer design |
| Compliance | Fully compliant with Chinese Pharmacopoeia (2010 Edition), USP <785>, and ISO 17511:2020 (in vitro diagnostic medical devices — requirements for establishing metrological traceability of values assigned to calibrators and human samples) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FPOSM-V2.0 |
| Measurement Range | 0–2000 mOsm/kg H₂O |
| Sample Volume | 100 µL |
| Analysis Time | ≤3 min |
| Pre-cooling Time | ≤3 min |
| Accuracy | ≤±1% |
| Repeatability | ≤1% |
| Linearity | ≤1% |
| Operating Temperature | 0–30 °C (recommended 15–25 °C) |
| Relative Humidity | ≤60% RH |
| Power Supply | 220 V AC, 50 Hz, 150 VA |
| Dimensions | 225 × 275 × 345 mm |
| Weight | 15 kg |
| Cooling System | Dual-stage thermoelectric (no heat-transfer fluid) |
| Display | 7-inch color capacitive touchscreen |
| Data Storage | 3-year audit-trail compliant archive with timestamped records |
| Calibration | Up to 31-point linear calibration |
| Regulatory Support | CFR 21 Part 11–compatible electronic signatures, user-level access control, GLP/GMP-ready data management |
| Brand | NeuronBC |
|---|---|
| Model | FPOSM-V2.0 |
| Measurement Principle | Freezing Point Depression (based on Raoult’s Law) |
| Measurement Range | 0–2000 mOsmol/kg |
| Sample Volume | 100 µL |
| Analysis Time | ≤3 min |
| Pre-cooling Time | ≤3 min |
| Accuracy | ≤±1% |
| Repeatability | ≤±1% |
| Linearity | ≤±1% |
| Operating Temperature | 0–30 °C (recommended 15–25 °C) |
| Relative Humidity | ≤60% RH |
| Power Supply | 220 V AC, 50 Hz, 150 VA |
| Dimensions | 225 × 275 × 345 mm |
| Weight | 15 kg |
| Compliance | Designed to support 21 CFR Part 11-compliant data integrity requirements (electronic signatures, user-level access control, audit-trail-ready data storage) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FPOSM-V2.0 |
| Measurement Range | 0–2000 mOsmol/kg |
| Sample Volume | 100 µL |
| Test Time | ≤3 min |
| Pre-cooling Time | ≤3 min |
| Accuracy | ≤1% |
| Repeatability | ≤1% |
| Linearity | ≤1% |
| Operating Temperature | 0–30 °C (recommended 15–25 °C) |
| Relative Humidity | ≤60% |
| Power Supply | 220 V, 50 Hz, 150 VA |
| Dimensions | 225 × 275 × 345 mm |
| Weight | 15 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FPOSM2.0 |
| Measurement Principle | Freezing Point Depression (based on Raoult’s Law) |
| Measurement Range | 0–2000 mOsmol/kg |
| Sample Volume | 100 µL |
| Test Time | ≤3 min |
| Pre-cooling Time | ≤3 min |
| Accuracy | ≤1% |
| Repeatability | ≤1% |
| Linearity | ≤1% |
| Operating Temperature | 0–30 °C (recommended 15–25 °C) |
| Relative Humidity | ≤60% |
| Power Supply | 220 V AC, 50 Hz, 150 VA |
| Dimensions | 225 × 275 × 345 mm |
| Weight | 15 kg |
| Compliance | Designed to support 21 CFR Part 11-compliant data integrity requirements (electronic signatures, user-level access control, audit-trail-capable data storage) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GT-2.0 |
| Pricing | Available Upon Request |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GT-2.0 |
| Power Supply | 100–220 VAC, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Response Threshold | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Operating Mode | Continuous |
| External Gas Source | Compressed Air, Nitrogen, or Inert Gas |
| Max Seal Pressure | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions | 400 × 260 × 250 mm |
| Weight | 7.5 kg |
| Brand | NeuronBC |
|---|---|
| Model | GT-2.0 |
| Type | Online & Offline Glove Integrity Tester |
| Compliance | GB/T 25915.7–2010 / ISO 14644-7:2004 |
| Power Supply | 100–220 VAC, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Pressure Resolution | ≤50 Pa |
| Operating Noise | ≤50 dB(A) |
| Max Seal Pressure | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions | 400 × 260 × 250 mm |
| Weight | 7.5 kg |
| External Gas Source | Compressed air, nitrogen, or inert gas |
| Mobility | Portable with rapid-connect fittings |
| Interface | Color touchscreen with time/date stamping |
| Regulatory Conformance | 21 CFR Part 11 (electronic records & signatures), audit trail, role-based access control |
| Brand | NeuronBC |
|---|---|
| Model | GT-2.0 |
| Origin | Beijing, China |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Pressure Resolution | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Operating Mode | Continuous |
| External Gas Source | Compressed Air, Nitrogen, or Inert Gas |
| Max Sealing Pressure | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions (L×W×H₁×H₂) | 400 × 260 × 270 × 250 mm |
| Glove Tray Configuration | Up to 6 trays per unit (customizable) |
| Optional Features | Audit Trail, USB Data Export, Printer Integration |
| Compliance | Designed per GB/T 25915.7–2010 / ISO 14644-7:2004, FDA 21 CFR Part 11–ready (with electronic signature and role-based access control) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | NeuronBC GT-2.0 Online |
| Power Supply | 100–220 VAC, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Pressure Resolution | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Operating Mode | Continuous |
| External Gas Source | Compressed air, nitrogen, or inert gas (max. inlet pressure ≤0.5 MPa) |
| Seal Pressure Capacity | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions | 400 × 260 × 250 mm |
| Weight | 7.5 kg |