| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | GT-5.0 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Pressure Resolution | ≤50 Pa |
| Operating Noise | ≤50 dB(A) |
| Maximum Seal Pressure | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Gas Supply | Compressed air, nitrogen, or inert gas |
| Tray Configuration | Up to 6 glove trays (customizable) |
| Compliance | Designed per GB/T 25915.7–2010 / ISO 14644-7:2004 |
| Regulatory Alignment | 21 CFR Part 11–ready (electronic signatures, audit trail, user access control) |
| Optional Features | USB data export, audit trail module, backup data archiving |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | IntegTest 4.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (115 psi) |
| Test Accuracy | Bubble Point ±50 mbar |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Range | 1–180 mL/min |
| Water Intrusion Range | 0.01–30 mL/min |
| Display | 5.7″ TFT monochrome LCD with backlight |
| Data Storage | 500 test records |
| Interface | RS232 serial port |
| Language Support | English & Chinese |
| Operating Environment | 5–40 °C, 10–80% RH |
| Dimensions (L×W×H₁×H₂) | 400 × 240 × 270 × 220 mm |
| Weight | 7.5 kg |
| Compliance | Suitable for ISO 13408-2, ASTM F838-22, USP <1207>, and GMP/GLP environments requiring filter integrity validation |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | IntegTest 6.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W (optional backup battery) |
| Operating Pressure Range | 100–10,000 mbar (145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (mm) | 400 (D) × 240 (W) × 270/220 (H1/H2) |
| Weight | 8 kg |
| Bubble Point Range | 100–8,000 mbar |
| Diffusion Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Test Accuracy | Net Volume ±4% |
| Supported Configurations | Symmetric & asymmetric membranes, syringe filters, capsule filters, flat-sheet filters, cartridge filters (up to 9-core, 20-inch), ultrafiltration cassettes & columns, irregular-format filters |
| Pre-stored Protocols | 80 |
| Audit Trail Events | ≥16 logged parameters (user, timestamp, method, result, etc.) |
| Data Storage | >5,000 test records (unlimited with USB backup) |
| Display | 7" high-resolution color touchscreen |
| Interface | RS232, USB |
| Language | English / Chinese |
| Compliance | Fully aligned with USP <1207>, EP 5.1.1, ISO 13408-2, and FDA 21 CFR Part 11 (electronic signatures, role-based access, audit trail) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FIT-V4.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (115 psi) |
| Test Methods | Bubble Point, Diffusion Flow, Pressure Hold, Water Intrusion |
| Accuracy | Bubble Point ±50 mbar |
| Test Range | Bubble Point 590–6900 mbar |
| Display | 5.7″ TFT monochrome LCD with backlight |
| Data Storage | 500 test records |
| Connectivity | RS232 serial interface |
| Language | English / Chinese |
| Operating Environment | ISO Class B cleanroom compliant |
| Dimensions (W×D×H) | 240 × 400 × 270 mm (base) + 220 mm (top module) |
| Weight | 7.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | BP1.2 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (max. 115 psi) |
| Bubble Point Accuracy | ±75 mbar |
| Diffusion Flow Accuracy | ±4% |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Range | 1–180 mL/min |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (L×W×H) | 400 × 240 × 270 mm (main unit) + 220 mm (height with printer module) |
| Weight | 7.5 kg |
| Display | 3.2″ monochrome LCD |
| Language | Chinese only |
| Data Storage | 20 test records |
| Test Modes | Automated bubble point, semi-automated diffusion flow |
| Filter Compatibility | Single- and multi-cartridge filters (≤3 cartridges, ≤20-inch length), syringe filters, capsule filters, flat-sheet filters, and cylindrical membrane filters (symmetric & asymmetric membranes) |
| Cleanroom Suitability | ISO Class B (or equivalent) environments |
| Regulatory Alignment | Designed to support ASTM F838-22, ISO 13408-2, USP <1207>, and EU Annex 1 requirements for filter validation and integrity testing |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | Integtest V1.2 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (max. 115 psi) |
| Bubble Point Accuracy | ±75 mbar |
| Diffusion Flow Accuracy | ±4% |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Rate Range | 1–180 mL/min |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (L×W×H₁×H₂) | 400 × 240 × 270 × 220 mm |
| Weight | 7.5 kg |
| Display | 3.2″ monochrome LCD |
| Data Storage | 20 test records |
| Language | Chinese only |
| Test Modes | Bubble point (fully automated), diffusion flow (semi-automated), pressure hold (manual setup) |
| Membrane Compatibility | Symmetric and asymmetric membranes |
| Filter Formats | Disc membranes (Φ25–300 mm), standard cartridges (2.5″–40″, 1–15 cores), capsule filters, mini-cartridges, flat-sheet filters, pleated cylindrical filters (≤20″, ≤3 cores), air/gas terminal filters |
| Installation Mode | Offline (benchtop) and online (with optional manifold interface) |
| Cleanroom Class Compatibility | ISO Class 5 (Grade B) and above |
| Compliance Context | Designed to support execution of ASTM F838-22, ISO 13408-2:2018, USP <1207>, EU GMP Annex 1 (2022), and Ph. Eur. 2.6.27 |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | Integtest V4.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (115 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (L×W×H) | 400 × 240 × 270 mm (base) + 220 mm (tower height) |
| Weight | 7.5 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusive Flow Accuracy | ±4% |
| Water Intrusion Accuracy | ±0.01 mL |
| Net Volume Measurement Accuracy | ±4% |
| Bubble Point Range | 590–6900 mbar |
| Diffusive Flow Range | 1–180 mL/min |
| Water Intrusion Flow Range | 0.01–30 mL/min |
| Display | 5.7″ monochrome TFT LCD with backlight |
| Data Storage | 500 test records |
| Interface | RS232 serial port |
| Language Support | English / Chinese |
| Test Modes | Manual Bubble Point, Standard Bubble Point, Enhanced Bubble Point, Diffusive Flow, Water Intrusion |
| Printer | Integrated thermal micro-printer |
| Application Scope | Symmetric & asymmetric membranes, syringe filters, capsule filters, flat-sheet filters, cartridge filters (≤3 elements, ≤20 inches) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | Integtest V4.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (115 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (L×W×H) | 400 × 240 × 270 mm (base) + 220 mm (height extension) |
| Weight | 7.5 kg |
| Display | 5.7″ monochrome TFT LCD with backlight |
| Data Storage | 500 test records |
| Interface | RS232 serial port |
| Language Support | English & Chinese |
| Test Modes | Manual Bubble Point, Standard Bubble Point, Enhanced Bubble Point, Diffusion Flow, Water Intrusion |
| Accuracy | Net Volume ±4%, Bubble Point ±50 mbar, Diffusion Flow ±4%, Water Intrusion ±0.01 mL |
| Measurement Ranges | Bubble Point 590–6900 mbar, Diffusion Flow 1–180 mL/min, Water Intrusion 0.01–30 mL/min |
| Print Output | Integrated thermal micro-printer |
| Filter Compatibility | Symmetric & asymmetric membranes, syringe filters, capsule filters, flat-sheet filters, cartridge filters (≤3 elements, ≤20 inches) |
| Compliance | Designed for ISO 13408-2, ASTM F838-22, and USP <1207> water intrusion method validation |
| Application Context | Offline and online integrity verification in Grade B cleanroom environments |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Integtest V6.5 |
| Price | USD 11,200 (approx.) |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (14.5–145 psi) |
| Temperature Range | +5 °C to +40 °C |
| Relative Humidity | 10–80 % RH |
| Dimensions (L×W×H) | 400 × 240 × 270 mm (main unit), +220 mm (height with display stand) |
| Weight | 8 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusive Flow Accuracy | ±4 % |
| Water Intrusion Accuracy | ±0.01 mL |
| Net Volume Measurement Accuracy | ±4 % |
| Bubble Point Range | 100–8,000 mbar |
| Diffusive Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Pre-stored Protocols | 80 |
| Audit Trail Events | 16+ traceable parameters (user, timestamp, method, pressure ramp, pass/fail status, etc.) |
| Data Storage | >5,000 test records (unlimited with USB backup) |
| Display | 7" high-resolution color touchscreen |
| Interface | RS232, USB, optional industrial bus modules (e.g., Modbus RTU/TCP, Profibus DP, analog 4–20 mA output) |
| Language Support | English & Chinese |
| Compliance | Fully aligned with FDA 21 CFR Part 11 (electronic signatures, role-based access control, audit trail, data immutability) and supports GLP/GMP validation protocols |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (145 psi) |
| Display | 10-inch true-color capacitive touchscreen |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Enclosure Rating | IP54 |
| Dimensions | 480 × 300 × 190 mm |
| Weight | 12 kg |
| Compliance | CE certified, FDA 21 CFR Part 11 compliant, GMP-aligned audit trail & electronic signature support |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Display | 10-inch true-color touchscreen |
| Enclosure Rating | IP54 |
| Weight | 12 kg |
| Dimensions (L×W×H) | 480 × 300 × 190 mm |
| Compliance | CE certified, compliant with EU GMP Annex 1, USP <1207>, EP 5.1.1, FDA 21 CFR Part 11, ISO 13408-2 |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Display | 10-inch true-color touchscreen |
| Data Storage Capacity | >300,000 test records |
| Ingress Protection Rating | IP54 |
| Dimensions | 480 × 300 × 190 mm |
| Weight | 12 kg |
| Interface Options | RS232, USB, configurable industrial bus (optional), wireless communication (optional) |
| Regulatory Compliance | CE certified, FDA 21 CFR Part 11 compliant, GMP-aligned audit trail and electronic signature support |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (max. 145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Display | 10-inch true-color touchscreen |
| Enclosure Rating | IP54 |
| Dimensions | 480 × 300 × 190 mm |
| Weight | 12 kg |
| Compliance | CE certified, FDA 21 CFR Part 11 compliant, GMP-aligned |
| Data Interface | RS232, USB, configurable industrial bus & wireless options (optional) |
| Maximum Test Configuration | 12-cartridge, 20-inch filter housing |
| Sensor Accuracy | High-precision pressure transducers with <±0.5% FS deviation |
| Audit Trail | Built-in, time-stamped, immutable event logging with user attribution |
| Language Support | English / Chinese |
| Pressure Units | mbar, kPa, psi, kgf/cm² |
| User Management | Four-tier role-based access control with customizable permissions and electronic signature support |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V1.1 |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Operating Pressure Range | 500–6900 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±75 mbar |
| Dimensions (W×D×H₁×H₂) | 400 × 380 × 100 × 235 mm |
| Display | 73 × 39 mm monochrome LCD |
| Ambient Operating Conditions | 5–35 °C, 10–80% RH |
| Test Duration (Rapid Bubble Point) | 9 ± 2 min |
| Test Duration (Bubble Point Scan) | 20 ± 2 min |
| Data Storage | 20 test records |
| Print Output | Integrated thermal printer (English language support) |
| Compliance | Designed to meet USP <1207>, ASTM F838-22, ISO 13408-2, and FDA 21 CFR Part 11 requirements for audit trail and electronic record integrity |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V1.2 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (115 psi) |
| Bubble Point Accuracy | ±75 mbar |
| Diffusion Flow Accuracy | ±4% |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Range | 1–180 mL/min |
| Display | 3.2″ monochrome LCD |
| Data Storage | 20 test records |
| Dimensions (L×W×H) | 400 × 240 × 270 mm (main unit) + 220 mm (height with printer) |
| Weight | 7.5 kg |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Compliance | FDA, USP <1207>, ISO 13408-2, Annex 1 (2022), and Chinese Pharmacopoeia (ChP) 2020 Edition |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V3.0 |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Dimensions (W×D×H) | 400 × 380 × 235 mm (height includes dual-level chassis design) |
| Test Pressure Range | 100–8000 mbar (1.5–116 psi) |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Net Volume Measurement Accuracy | ±4% |
| Test Duration (typical) | Bubble Point: 15 ±2 min |
| Enhanced Bubble Point | 20 ±2 min |
| Diffusion Flow | 10 ±2 min |
| Net Volume Determination | 5 ±2 min |
| Operating Environment | 5–35 °C, 10–80% RH |
| Data Storage | 500 test records with full pressure-time curves |
| Display | 5.7" monochrome TFT LCD with backlight |
| Interface | RS232 serial port |
| Language Support | English, Chinese |
| Compliance | Meets requirements of USP <1207>, ISO 13408-2, ASTM F838-22, and EU GMP Annex 1 for sterile filtration validation |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | Integtest™ V4.0 Portable |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Operating Pressure Range | 100–6900 mbar |
| Pressure Resolution | ±1.0 mbar |
| Bubble Point Accuracy | ±75 mbar |
| Test Duration (Rapid Bubble Point) | 8 ± 2 min |
| Test Duration (Bubble Point Scan) | 20 ± 2 min |
| Ambient Operating Conditions | 5–35 °C, 10–80% RH |
| Display | Monochrome LCD, 73 × 39 mm with backlight |
| Data Storage | 20 test records |
| Print Output | Integrated Chinese-language thermal printer |
| Dimensions (W × D × H₁ × H₂) | 400 × 380 × 100 × 235 mm |
| Weight | Approx. 8.2 kg |
| Compliance | Designed to support FDA 21 CFR Part 11 readiness, USP <1207>, ISO 13408-2, and Annex 1 (2022) requirements for sterile filtration validation |
| Brand | NeuronBC |
|---|---|
| Model | JWG-8A |
| Origin | Beijing, China |
| Compliance | Chinese Pharmacopoeia (2015 Edition), USP <788>, USP <789>, ISO 21501-4 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sample Volume Range | 0.1–25 mL (adjustable via interchangeable high-pressure syringe pumps) |
| Laser Source | Imported stabilized diode laser (650 nm, Class 1) |
| Particle Size Range | 2–100 µm (calibrated with NIST-traceable polystyrene latex standards) |
| Sensitivity | ≥90% counting efficiency for particles ≥10 µm |
| Flow Cell Material | 316L stainless steel + PTFE-wetted path |
| Stirring System | Variable-speed glass paddle stirrer (0–300 rpm, ±2 rpm control accuracy) |
| Display | 10.1″ capacitive color touchscreen (1280×800) |
| Data Storage | Internal SSD (≥64 GB), supports CSV/PDF export |
| Software | NeuronBC PartiView™ v3.2 (audit-trail enabled in “S” variant), 21 CFR Part 11 compliant modules available |
| Connectivity | USB 3.0, Ethernet, RS-232 |
| Environmental Operation | 5–40 °C, 20–85% RH, altitude-independent performance (0–5000 m ASL) |
| Regulatory Support | IQ/OQ/PQ documentation package available |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | MFT-1000 |
| Detection Principles | Vacuum Decay & Pressure Decay |
| Compliance | USP <1207>, ASTM F2338-22, FDA 21 CFR Part 11, GMP Annex 1 (2022), ISO 15378:2017 |
| Test Range | −0.1 to 1.0 MPa (selectable ranges) |
| Differential Pressure Sensor | ±2 kPa, accuracy ≤0.5% FS, resolution 0.1 Pa |
| Minimum Detectable Equivalent Orifice Diameter | 1–2 µm |
| Display | 10-inch color capacitive touchscreen |
| Power | AC 100–240 V, 50/60 Hz, ≤200 W |
| Enclosure Rating | IP54 |
| Data Retention | ≥10 years (audit trail + event logs) |
| User Management | 4-tier role-based access control with customizable permissions |
| Output Interfaces | 4–20 mA, RS485, Ethernet, USB, 12 V alarm |
| Data Export | Raw test data, metadata, configuration files via USB |
| Optional Connectivity | Wireless module (Wi-Fi/Bluetooth), OPC UA, MQTT support |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | MFT-900 |
| Detection Principle | Vacuum Decay / Differential Pressure |
| Compliance | USP <1207>, ASTM F2338-22, FDA Guidance on Container Closure Integrity Testing (CCIT) |
| Test Range | −0.1 to 1.0 MPa (selectable), Differential Pressure Sensor: ±2 kPa, Accuracy ≤0.5% F.S., Resolution: 0.1 Pa |
| Minimum Detectable Leak Equivalent Hole Diameter | 2 µm |
| Touchscreen | 10-inch Color TFT LCD |
| Power | AC 100–240 V, 50/60 Hz, ≤200 W |
| Audit Trail Retention | ≥5 years |
| User Access Control | 4-tier Role-Based Authentication |
| Data Export | USB drive, CSV format |
| Communication Interfaces | Ethernet, RS485, 4–20 mA analog output, 12 V alarm signal |
| Optional Accessories | Certified Standard Leak Reference Vials (NIST-traceable), Custom Test Chamber Kits, Method Validation Support Services |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | MFT-900 |
| Detection Principle | Vacuum Decay / Differential Pressure Method |
| Compliance | USP <1207>, ASTM F2338-22, FDA Guidance on Container Closure Integrity Testing (CCIT) |
| Automation Level | Semi-Automatic |
| Detection Sensitivity | Equivalent to ≥2 µm defect aperture |
| Pressure Range | −0.1 to 1.0 MPa (selectable ranges: −0.1–0.2 MPa / −0.1–0.7 MPa / −0.1–1.0 MPa) |
| Differential Pressure Sensor | ±2 kPa, Accuracy ≤0.5% FS, Resolution: 0.1 Pa |
| Test Pressure Sensor Accuracy | ≤±1% FS |
| Display | 10-inch color capacitive touchscreen |
| Data Storage | ≥5 years audit-trail-enabled event logs & test records |
| User Management | 4-tier role-based access control (RBAC), password-authenticated login |
| Regulatory Support | Full 21 CFR Part 11 compliance (electronic signatures, audit trail, data integrity) |
| Interface Options | Ethernet, USB, RS485, 4–20 mA analog output, 12 V alarm signal |
| Power Supply | AC 100–240 V, 50/60 Hz, ≤200 W |
| Data Export | USB flash drive backup |
| Optional Peripherals | External thermal printer |
| Brand | Neuronbc |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NBC-1002 |
| Price | USD 28,000 (FOB Beijing) |
| Excitation Wavelength | 785 nm |
| Laser Power | ≤500 mW (adjustable) |
| Spectral Range | 200–3200 cm⁻¹ |
| Spectral Resolution | ≤8 cm⁻¹ |
| Detector | TE-cooled CCD |
| Battery Life | ≥6 hours (continuous operation) |
| Connectivity | Wi-Fi 5 (802.11ac), Bluetooth 5.0, USB-C |
| Data Storage | Internal 64 GB + cloud-sync capable |
| Compliance | Meets ISO/IEC 17025 calibration traceability requirements |
| Brand | NeuronBC |
|---|---|
| Model | NSTS-1000 |
| Origin | Beijing, China |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 120 W |
| Pump Speed Range | 20–300 rpm |
| Height of Suspension Assembly | 45 cm |
| Net Weight | 18 kg |
| Construction Material | Electropolished Stainless Steel (316L-grade compatible) |
| Motor Type | Brushless DC Motor with Continuous Speed Control |
| Display | High-Resolution Color Touchscreen Interface |
| Safety Protections | Overcurrent, Overvoltage, Overload, Stall Detection, Adjustable Pressure-Limit Protection |
| Tubing Clamping | One-Touch Linear Pump Head with Quick-Release Cap |
| Compliance | Designed to support USP <71>, EP 2.6.1, and ISO 11737-1 workflows |
| Brand | Neuronbc |
|---|---|
| Origin | Beijing, China |
| Model | RIT-1000 |
| Compliance | FDA 21 CFR Part 11, EU Annex 11, GAMP 5 |
| Test Principle | Pressure Decay Method |
| Port Compatibility | Universal RTP interface (ISO 14644-3 compliant flange dimensions) |
| Sensitivity | ≤0.1 Pa/s pressure decay detection threshold |
| Operating Environment | ISO Class C/D cleanrooms |
| Form Factor | Portable benchtop unit with integrated pressure sensor and vacuum pump |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-200 |
| Price | USD 25,000 (FOB) |
| Measurement Range | 0.1–30,000 mg/L TOC |
| Detection Principle | Catalytic Combustion Oxidation + Non-Dispersive Infrared (NDIR) Detection |
| Sample Throughput | ≤60 samples/hour |
| Oxidation Temperature | 680–900 °C (adjustable) |
| NDIR Detector Resolution | 24-bit |
| Control System Architecture | 32-bit embedded signal processing |
| Gas Flow Monitoring | Integrated mass flow sensor with auto-leak detection |
| Sample Introduction | Programmable syringe pump with 0.1–5 mL injection volume |
| Compliance | Designed to meet ISO 8466-2, EPA Method 415.3, and ASTM D7573 requirements |
| Brand | NeuronBC |
|---|---|
| Model | V4.0 |
| Display | 5.7″ backlit digital LCD |
| Interface | Chinese-language GUI |
| Data Visualization | Real-time test curve and numerical display |
| Processing | Dual-core embedded controller |
| Software | PC-based upper-computer software with audit trail capability |
| User Management | Multi-level password-protected access control |
| Safety Protection | Automatic pressure-limiting and overpressure cutoff for filter safeguard |
| Test Methods | Forward flow (diffusion), bubble point, and water intrusion (for hydrophobic membranes) |
| Compliance Support | Configurable report generation aligned with FDA 21 CFR Part 11 and EU Annex 11 requirements |
| Reporting | Optional integrated thermal printer interface |
| Membrane Compatibility | Flat-sheet membranes, cartridge filters, and disc filters |
| Origin | Beijing, China |
| Price | USD 5,600 (FOB) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | V4.0 |
| Price | USD 5,300 (FOB) |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar |
| Test Accuracy | Bubble Point ±50 mbar |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Range | 1–180 mL/min |
| Water Intrusion Range | 0.01–30 mL/min |
| Display | 5.7″ monochrome TFT LCD with backlight |
| Data Storage | 500 test records |
| Interface | RS232 serial port |
| Language Support | English & Chinese |
| Operating Modes | Online & Offline |
| Environmental Class | ISO Class B or better |
| Weight | 7.5 kg |
| Dimensions (L×W×H₁×H₂) | 400 × 240 × 270 × 220 mm |
| Relative Humidity | 10–80% RH |
| Ambient Temperature | +5 °C to +40 °C |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V6.5 Audit-Trail |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar |
| Temperature Range | +5°C to +40°C |
| Relative Humidity | 10–80% |
| Dimensions (mm) | 400(D) × 240(W) × 270(H1) × 220(H2) |
| Weight | 8 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Water Intrusion Accuracy | ±0.01 mL |
| Bubble Point Range | 100–8,000 mbar |
| Diffusion Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Pre-stored Protocols | 80 |
| Event Log Capacity | ≥16 auditable parameters with timestamp |
| User Access Levels | 4-tier role-based authentication with electronic signature support |
| Compliance | Fully aligned with FDA 21 CFR Part 11, ALCOA+ data integrity principles, and ISO 13485 / ASTM F838-22 / USP <1207> guidance for filter integrity testing |
| Brand | NeuronBC |
|---|---|
| Model | V6.5 |
| Origin | Beijing, China |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (mm) | 400 (D) × 240 (W) × 270/220 (H1/H2) |
| Weight | 8 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusive Flow Accuracy | ±4% |
| Water Intrusion Accuracy | ±0.01 mL |
| Net Volume Test Accuracy | ±4% |
| Bubble Point Range | 100–8,000 mbar |
| Diffusive Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Pre-stored Protocols | 80 |
| Event Log Capacity | ≥16 auditable events with timestamped traceability |
| User Access Levels | 4-tier role-based authentication with electronic signature support |
| Data Storage | ≥5,000 test records, USB backup of full datasets including real-time curves |
| Display | 7" high-resolution color touchscreen |
| Interface Options | RS232, USB, optional industrial fieldbus (e.g., Modbus TCP, Profibus DP) and analog I/O |
| Language Support | English / Chinese |
| Compliance | FDA 21 CFR Part 11, ALCOA+ principles, Annex 11 (EU GMP), ISO 13408-2, ASTM F838, USP <1207> |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Operating Pressure Range | 100–10,000 mbar (150 psi) |
| Pressure Units | mbar, kPa, psi, kgf/cm² |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 480 × 300 × 190 mm |
| Weight | 10 kg |
| Compliance | CE Marked, FDA 21 CFR Part 11, GMP-Aligned Audit Trail & Electronic Signature Support |
| Display | 10-inch true-color touchscreen |
| Data Export | USB (raw test data, configuration files, audit logs) |
| Connectivity | RS232, USB |
| Sensor Accuracy | High-precision pressure transducers with low drift and extended pneumatic line compensation up to 100 m |
| Integrated Thermal Printer | Non-ink, particle-free, archival-grade print retention (>10 years) |
| User Management | Four-tier role-based access control with customizable permissions, mandatory electronic signatures, and password-protected login |