Physical Property Testing Instruments
Filter
Showing 361–390 of 12188 results
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Litesizer DIA Series |
| Pricing | Upon Request |
| Dispersion Methods | Wet, Dry, and Free-Fall Dispersion |
| Instrument Type | Laboratory-Based Dynamic Image Analyzer |
| Measurement Range | 0.5 µm to 16,000 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–15 seconds per analysis |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Litesizer DIA Series |
| Measurement Principle | Dynamic Image Analysis (DIA) |
| Measurement Range | 0.5 µm to 16,000 µm (dependent on dispersion mode and magnification) |
| Camera Resolution | 5 MPix (2448 × 2048 pixels) with pixel sizes of 0.5 µm / 0.8 µm / 10 µm (model-dependent) |
| Dispersion Modes | Wet dispersion (liquid carrier + optional ultrasonication), dry dispersion (compressed air jet), free-fall dispersion (gravity-driven) |
| Shape & Size Parameters | Feret min/max, projected area-equivalent diameter, length, geodesic length (for fibers), Legendre ellipse major/minor axes, aspect ratio, ellipticity, irregularity, elongation, circularity, shape factor, compactness, convexity, solidity — all compliant with ISO 9276-6:2023 |
| Data Acquisition Rate | Up to 220 fps (Litesizer DIA 700, 5 MPix) |
| Optical Magnification | 0.3×, 1×, and 6× (DIA 700) |
| Interface | 1 × 10 GbE, 1 × USB-A 3.0 |
| Dimensions (H×W×D) | 400 mm × 790 mm × 290 mm |
| Weight | 41 kg |
| Power Supply | 100–240 V ±10%, 50/60 Hz |
| Compressed Air | 5–10 bar (72–145 psi) |
| Liquid Supply Pressure | ≤8 bar (116 psi) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 0.01–3500 µm (DIF 500) / 0.1–2500 µm (DIF 300) / 0.1–1000 µm (DIF 100) |
| Repeatability | Better than ±0.5% RSD |
| Measurement Time | <10 s |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Litesizer DIF |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | < ±0.5% |
| Measurement Time | < 10 s |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DIF500 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | < ±0.5% |
| Measurement Time | < 10 s |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | Litesizer DLS 101 |
| Particle Size Range | 0.3 nm – 12 µm |
| Size Measurement Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz (658 nm diode laser) |
| Measurement Principle | Dynamic Light Scattering (DLS) |
| Sample Concentration Range | up to 50% w/v |
| Minimum Sample Volume | 1.5 µL |
| Zeta Potential Range | –500 mV to +500 mV |
| Typical Measurement Time | <1 min |
| Molecular Weight Range | 1 kDa – 20 MDa |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | Litesizer DLS 501 |
| Zeta Potential Range | ±1000 mV |
| pH Range | 2–12 |
| Temperature Range | 0–120 °C |
| pH Resolution | 0.01 |
| Temperature Resolution | 0.01 |
| Accuracy | ±3% (Zeta), ±2% (DLS), ±10% (Molecular Weight) |
| Repeatability | ±3% (Zeta), ±2% (DLS), ±5% (Molecular Weight) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | Litesizer DLS |
| Particle Size Range | 0.3 nm – 15 µm (diameter) / 0.3 nm – 10 µm (diameter) |
| Size Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz |
| Size Measurement Principle | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS) |
| Zeta Potential Range | ±1000 mV |
| Zeta Potential Reproducibility | ±3% |
| Molecular Weight Range | 300 Da – 20 MDa |
| Sample Volume | 1.5 µL – 1 mL |
| Concentration Range | up to 50% w/v |
| Measurement Time | <1 min |
| Transmission Monitoring | Real-time, 0–100% |
| Refractive Index Measurement Accuracy | ±0.5% (range: 1.28–1.50) |
| Optical Configurations | Fluorescence & polarization filters (15°, 90°, 175°) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Litesizer DLS 101 / 501 / 701 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Sizing System |
| Measurement Range | 0.3 nm – 12 μm (particle diameter) |
| Repeatability | ±2% |
| Measurement Time | < 60 s |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Litesizer DLS Series |
| Particle Size Range | 0.3 nm – 15 µm (DLS, DLS 701) |
| Size Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz (658 nm diode laser) |
| Particle Sizing Method | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS) |
| Sample Volume | 1.5 µL – 1 mL |
| Sample Concentration | up to 50% w/v |
| Zeta Potential Range | ±1000 mV |
| Measurement Time | < 60 s |
| Molecular Weight Range | 300 Da – 20 MDa |
| Zeta Potential Reproducibility | ±3% |
| Refractive Index Accuracy | ±0.5% (for DLS 701/501) |
| Transmission Monitoring | 0–100%, resolution <1% |
| Brand | Anton Paar TriTec (formerly CSM, Switzerland) |
|---|---|
| Origin | Switzerland |
| Model | Lovis 2000 M/ME |
| Viscosity Range | 0.3–10,000 mPa·s |
| Repeatability | < 0.1 % |
| Reproducibility | < 0.5 % |
| Ball Fall Time Range | 0–250 s (up to 1000 s with extended mode) |
| Time Resolution | 0.001 s |
| Temperature Control Range | +5 to +100 °C |
| Temperature Stability | ±0.005 °C |
| Temperature Accuracy | < ±0.02 °C |
| Sample Volume | 0.1–0.8 mL |
| Power Supply | 100–240 V, 50–60 Hz, 190 VA |
| Dimensions (L×W×H) | 482 × 420 × 231 mm |
| Weight | 17 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Lovis 2000 M/ME |
| Instrument Type | Falling Ball Viscometer |
| Mounting | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.3 mPa·s to 10,000 mPa·s |
| Temperature Range | +5 °C to 100 °C |
| Sample Volume | 100 µL (minimum) |
| Tilt Angle Range | 15° to 80° (1° increments) |
| Shear Rate Range | 0.5 s⁻¹ to 1,000 s⁻¹ |
| Viscosity Repeatability | ≤ 0.1 % (std. dev.) |
| Viscosity Accuracy | ≤ 0.5 % |
| Temperature Repeatability | ±0.005 °C |
| Temperature Accuracy | ±0.02 °C |
| Timing Resolution | 0.001 s |
| Timing Accuracy | ±0.05 % |
| Measurement Time | As low as 30 s (typical: 3 min) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Lovis 2001 |
| Instrument Type | Fixed-Position Falling-Ball Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.2 to 10,000 mPa·s |
| Temperature Range | 5 °C to 100 °C (41 °F to 212 °F) |
| Temperature Resolution | 0.005 °C |
| Temperature Accuracy | ±0.02 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MCR 303 / MCR 503 / MCR 503 Power |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Fluids |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Temperature Range | –160 °C to 1000 °C |
| Frequency Range | 2 × 10⁻⁸ Hz to 200 Hz |
| Minimum Rotational Speed | 0 rpm |
| Maximum Torque | 300 mNm |
| Maximum Rotational Speed | 3000 rpm |
| Torque Resolution | 0.05 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MCR 303 |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Liquids |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Temperature Range | –160 °C to +1000 °C |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 2 × 10⁻⁸ Hz to 100 Hz |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 215 mNm |
| Torque Resolution | 0.1 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MCR 703 |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Fluids |
| Sample State | Liquid |
| Bearing System | Precision Porous Carbon Air Bearings |
| Minimum Angular Velocity | 0 rad/s |
| Frequency Range | 2 × 10⁻⁸ Hz to 200 Hz (equivalent to 10⁻⁷ – 628 rad/s) |
| Maximum Angular Velocity | 628 rad/s (6000 rpm in counter-rotation mode) |
| Maximum Torque | 230 mNm |
| Torque Resolution | 0.05 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MCR 703 |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Fluids |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Frequency Range | 2 × 10⁻⁸ – 200 Hz |
| Minimum Rotational Speed | 0 rpm |
| Maximum Torque | 230 mNm |
| Maximum Rotational Speed | 6000 rpm |
| Torque Resolution | <1 nrad |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | MCR 703 MultiDrive |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −160 °C to +1000 °C |
| Frequency Range | 2 × 10⁻⁸ Hz to 200 Hz |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MCR 703 Multidrive Space + Rheo-Optics Module |
| Instrument Type | Rotational Rheometer |
| Sample Type | High-Viscosity Fluids |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Frequency Range | 2 × 10⁻⁸ – 200 Hz |
| Minimum Rotational Speed | 0 rpm |
| Maximum Torque | 230 mNm |
| Maximum Rotational Speed | 6000 rpm |
| Torque Resolution | <1 nrad |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MCR 703 Space MultiDrive |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Liquids |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Temperature Range | −160 °C to 1000 °C |
| Minimum Angular Velocity | 0 rad/s (0 rpm) |
| Maximum Angular Velocity | 628 rad/s (6000 rpm) |
| Maximum Torque | 230 mNm |
| Torque Resolution | 0.05 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | MCR 72 / MCR 92 |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Motor Bearing | Ball Bearing (MCR 72) / Air Bearing (MCR 92) |
| Minimum Rotational Speed | 0.001 rpm |
| Frequency Range | 0.0001–628 rad/s |
| Maximum Rotational Speed | 1500 rpm |
| Maximum Torque | 125 mNm |
| Torque Resolution | 100 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MCR 72 / MCR 92 |
| Instrument Type | Rotational Rheometer |
| Sample State | Solid, Semi-Solid, Paste, Gel, Molten Polymer |
| Bearing System | Ball Bearing (MCR 72) / Air Bearing (MCR 92) |
| Temperature Range | –50 °C to +400 °C |
| Minimum Angular Velocity | 10⁻⁴ rad/s (≈0.001 rpm) |
| Maximum Angular Velocity | 157 rad/s (1500 rpm) |
| Frequency Range | 10⁻⁴ to 628 rad/s (0.0001–100 Hz) |
| Maximum Torque | 125 mNm |
| Torque Resolution | 100 nNm |
| Normal Force Control | SafeGap™ integrated |
| Optical Sample Observation | TruRay™ adjustable LED illumination |
| Tool Recognition | Toolmaster™ auto-identification for transducers and temperature units |
| Drive System | EC brushless DC motor with high-resolution optical encoder |
| Control Modes | Controlled Shear Stress (CSS), Controlled Shear Rate (CSR), Controlled Strain (CSA), Controlled Stress (CSD) |
| Compliance | ASTM D3835, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11-ready software architecture |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MCR |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity |
| Sample State | Liquid |
| Motor Bearing | Air Bearing |
| Temperature Range | −160 °C to 1000 °C |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 2×10⁻⁸–200 rad/s |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 300 mNm |
| Torque Resolution | 0.05 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MCR Powder Rheometer |
| Instrument Type | Multifunctional Powder Flowability Tester |
| Minimum Sample Volume | 4.3 mL / 18.9 mL |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | MCR Series + Cora 5001 |
| Instrument Type | Rotational Rheometer with Integrated In Situ Raman Spectroscopy |
| Sample Type | High-Viscosity Liquids and Melts |
| Sample State | Liquid/Melt |
| Bearing System | Precision Porous Carbon Air Bearing |
| Temperature Range | 10 °C to 35 °C (non-condensing environment) |
| Frequency Range | 2 × 10⁻⁸ Hz to 200 Hz |
| Minimum Rotational Speed | 0 rpm |
| Maximum Torque | 300 mNm |
| Maximum Rotational Speed | 3000 rpm |
| Torque Resolution | 0.05 nNm (with TruStrain™ active) |
| Excitation Wavelengths | 532 nm, 785 nm, and 1064 nm (dual-wavelength configuration available) |
| Raman Spectral Range | 100–3500 cm⁻¹ (dependent on laser wavelength) |
| Spectral Resolution (ASTM E2529) | 6–17 cm⁻¹ |
| Laser Power | Adjustable up to 450 mW (sample-side) |
| Detector | 2048-pixel CCD (532/785 nm), 256-pixel InGaAs (1064 nm) |
| Data Acquisition | Real-time synchronized rheological and spectral streaming |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MCR Series |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing Type | Air Bearing |
| Temperature Range | −160 °C to 1000 °C |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 2×10⁻⁸ to 200 rad/s |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 300 mNm |
| Torque Resolution | 0.05 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MCR Tribological Tester |
| Instrument Type | Coefficient of Friction Analyzer |
| Maximum Friction Force | 70 N |
| Friction Force Resolution | 0.005 N |
| Maximum Temperature | 600 °C |
| Normal Force Range | 0.1–70 N |
| Normal Force Resolution | 0.005 N |
| Rotational Speed Range | 10⁻⁶–3000 rpm |
| Sliding Velocity Range | 10⁻⁸–3.3 m/s |
| Torque Range | 1 nNm–300 mNm |
| Torque Resolution | 0.1 nNm |
| Oscillation Frequency Range | 10⁻⁷–100 Hz |
| Angular Amplitude Range | 1 µrad to ∞ |
| Angular Resolution | 10 nrad |
| Minimum In-situ Wear Depth Detection | 0.65 µm |
| Electrotribology Capability | Yes (0–4 kV, up to 1 mA) |
| Temperature Control Range (T-BTP module) | −160 °C to +600 °C |
| Humidity Range | 5–95% RH |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MCR303 / MCR503 |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing System | Air Bearing |
| Temperature Range | −160 °C to 1000 °C |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 2 × 10⁻⁸ Hz |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 215 mNm / 230 mNm |
| Torque Resolution | 0.1 nNm / 0.06 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | MCT³ |
| Instrument Type | Micro/Nano Scratch and Indentation Tester |
| Maximum Indentation Depth | 1000 µm |
| Effective Load Range | 30 N |
| Load Resolution | 6 µN |
| Displacement Resolution | 0.05 nm |
| Load Noise (RMS) | 100 µN |
| Depth Noise (RMS) | 1.5 nm |
| Data Acquisition Rate | 192 kHz |
| Scratch Speed Range | 0.1–600 mm/min |
| Depth Measurement Range | 1000 µm |
| Depth Resolution | 0.03 nm |
| Optional Modules | Peltier Stage (−120 °C to +120 °C), Heated Stage (up to 200 °C), Liquid Environment Cell |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MHT³ |
| Instrument Type | (Micro/Nano) Scratch Tester |
| Load Range | 10 mN – 30 N |
| Load Resolution | 6 µN |
| Load Noise (RMS) | 100 µN |
| Depth Range | 0–1000 µm |
| Depth Resolution | 0.03 nm |
| Depth Noise (RMS) | 1.5 nm |
| Data Acquisition Rate | 192 kHz |
| Scratch Speed | 0.1–600 mm/min |
| Maximum Heating Temperature (Peltier) | 120 °C |
| Optional Heating Stage | up to 200 °C |
| Optional Cryo Cooling | down to −120 °C |
| Liquid Environment Testing | Yes |